1.
Radiother Oncol ; 190: 109953, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37839557

RESUMO

BACKGROUND AND PURPOSE: The FLASH effect has been validated in different preclinical experiments with electrons (eFLASH) and protons (pFLASH) operating at an average dose rate above 40 Gy/s. However, no systematic intercomparison of the FLASH effect produced by eFLASHvs. pFLASH has yet been performed and constitutes the aim of the present study. MATERIALS AND METHODS: The electron eRT6/Oriatron/CHUV/5.5 MeV and proton Gantry1/PSI/170 MeV were used to deliver conventional (0.1 Gy/s eCONV and pCONV) and FLASH (≥110 Gy/s eFLASH and pFLASH) dose rates. Protons were delivered in transmission. Dosimetric and biologic intercomparisons were performed using previously validated dosimetric approaches and experimental murine models. RESULTS: The difference between the average absorbed dose measured at Gantry 1 with PSI reference dosimeters and with CHUV/IRA dosimeters was -1.9 % (0.1 Gy/s) and + 2.5 % (110 Gy/s). The neurocognitive capacity of eFLASH and pFLASH irradiated mice was indistinguishable from the control, while both eCONV and pCONV irradiated cohorts showed cognitive decrements. Complete tumor response was obtained after an ablative dose of 20 Gy delivered with the two beams at CONV and FLASH dose rates. Tumor rejection upon rechallenge indicates that anti-tumor immunity was activated independently of the beam-type and the dose-rate. CONCLUSION: Despite major differences in the temporal microstructure of proton and electron beams, this study shows that dosimetric standards can be established. Normal brain protection and tumor control were produced by the two beams. More specifically, normal brain protection was achieved when a single dose of 10 Gy was delivered in 90 ms or less, suggesting that the most important physical parameter driving the FLASH sparing effect might be the mean dose rate. In addition, a systemic anti-tumor immunological memory response was observed in mice exposed to high ablative dose of electron and proton delivered at CONV and FLASH dose rate.


Assuntos
Produtos Biológicos , Neoplasias , Terapia com Prótons , Humanos , Animais , Camundongos , Prótons , Elétrons , Dosagem Radioterapêutica , Radiometria
3.
Phys Med Biol ; 68(24)2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-37820691

RESUMO

Objective.Online adaptive radiotherapy aims to fully leverage the advantages of highly conformal therapy by reducing anatomical and set-up uncertainty, thereby alleviating the need for robust treatments. This requires extensive automation, among which is the use of deformable image registration (DIR) for contour propagation and dose accumulation. However, inconsistencies in DIR solutions between different algorithms have caused distrust, hampering its direct clinical use. This work aims to enable the clinical use of DIR by developing deep learning methods to predict DIR uncertainty and propagating it into clinically usable metrics.Approach.Supervised and unsupervised neural networks were trained to predict the Gaussian uncertainty of a given deformable vector field (DVF). Since both methods rely on different assumptions, their predictions differ and were further merged into a combined model. The resulting normally distributed DVFs can be directly sampled to propagate the uncertainty into contour and accumulated dose uncertainty.Main results.The unsupervised and combined models can accurately predict the uncertainty in the manually annotated landmarks on the DIRLAB dataset. Furthermore, for 5 patients with lung cancer, the propagation of the predicted DVF uncertainty into contour uncertainty yielded for both methods anexpected calibration errorof less than 3%. Additionally, theprobabilisticly accumulated dose volume histograms(DVH) encompass well the accumulated proton therapy doses using 5 different DIR algorithms. It was additionally shown that the unsupervised model can be used for different DIR algorithms without the need for retraining.Significance.Our work presents first-of-a-kind deep learning methods to predict the uncertainty of the DIR process. The methods are fast, yield high-quality uncertainty estimates and are useable for different algorithms and applications. This allows clinics to use DIR uncertainty in their workflows without the need to change their DIR implementation.


Assuntos
Aprendizado Profundo , Humanos , Incerteza , Redes Neurais de Computação , Algoritmos , Planejamento da Radioterapia Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos
4.
Phys Med Biol ; 68(17)2023 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-37385266

RESUMO

Objective.Anatomical and daily set-up uncertainties impede high precision delivery of proton therapy. With online adaptation, the daily plan is reoptimized on an image taken shortly before the treatment, reducing these uncertainties and, hence, allowing a more accurate delivery. This reoptimization requires target and organs-at-risk (OAR) contours on the daily image, which need to be delineated automatically since manual contouring is too slow. Whereas multiple methods for autocontouring exist, none of them are fully accurate, which affects the daily dose. This work aims to quantify the magnitude of this dosimetric effect for four contouring techniques.Approach.Plans reoptimized on automatic contours are compared with plans reoptimized on manual contours. The methods include rigid and deformable registration (DIR), deep-learning based segmentation and patient-specific segmentation.Main results.It was found that independently of the contouring method, the dosimetric influence of usingautomaticOARcontoursis small (<5% prescribed dose in most cases), with DIR yielding the best results. Contrarily, the dosimetric effect of using theautomatic target contourwas larger (>5% prescribed dose in most cases), indicating that manual verification of that contour remains necessary. However, when compared to non-adaptive therapy, the dose differences caused by automatically contouring the target were small and target coverage was improved, especially for DIR.Significance.The results show that manual adjustment of OARs is rarely necessary and that several autocontouring techniques are directly usable. Contrarily, manual adjustment of the target is important. This allows prioritizing tasks during time-critical online adaptive proton therapy and therefore supports its further clinical implementation.


Assuntos
Terapia com Prótons , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Radiometria , Órgãos em Risco
5.
Phys Med Biol ; 68(11)2023 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-37172608

RESUMO

Objective.4D dose reconstruction in proton therapy with pencil beam scanning (PBS) typically relies on a single pre-treatment 4DCT (p4DCT). However, breathing motion during the fractionated treatment can vary considerably in both amplitude and frequency. We present a novel 4D dose reconstruction method combining delivery log files with patient-specific motion models, to account for the dosimetric effect of intra- and inter-fractional breathing variability.Approach.Correlation between an external breathing surrogate and anatomical deformations of the p4DCT is established using principal component analysis. Using motion trajectories of a surface marker acquired during the dose delivery by an optical tracking system, deformable motion fields are retrospectively reconstructed and used to generate time-resolved synthetic 4DCTs ('5DCTs') by warping a reference CT. For three abdominal/thoracic patients, treated with respiratory gating and rescanning, example fraction doses were reconstructed using the resulting 5DCTs and delivery log files. The motion model was validated beforehand using leave-one-out cross-validation (LOOCV) with subsequent 4D dose evaluations. Moreover, besides fractional motion, fractional anatomical changes were incorporated as proof of concept.Main results.For motion model validation, the comparison of 4D dose distributions for the original 4DCT and predicted LOOCV resulted in 3%/3 mm gamma pass rates above 96.2%. Prospective gating simulations on the p4DCT can overestimate the target dose coverage V95%by up to 2.1% compared to 4D dose reconstruction based on observed surrogate trajectories. Nevertheless, for the studied clinical cases treated with respiratory-gating and rescanning, an acceptable target coverage was maintained with V95%remaining above 98.8% for all studied fractions. For these gated treatments, larger dosimetric differences occurred due to CT changes than due to breathing variations.Significance.To gain a better estimate of the delivered dose, a retrospective 4D dose reconstruction workflow based on motion data acquired during PBS proton treatments was implemented and validated, thus considering both intra- and inter-fractional motion and anatomy changes.


Assuntos
Neoplasias Pulmonares , Terapia com Prótons , Humanos , Terapia com Prótons/métodos , Estudos Retrospectivos , Estudos Prospectivos , Tomografia Computadorizada Quadridimensional/métodos , Movimento (Física) , Carmustina , Planejamento da Radioterapia Assistida por Computador/métodos
6.
bioRxiv ; 2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37131769

RESUMO

Background and purpose: The FLASH effect has been validated in different preclinical experiments with electrons (eFLASH) and protons (pFLASH) operating at a mean dose rate above 40 Gy/s. However, no systematic intercomparison of the FLASH effect produced by e vs. pFLASH has yet been performed and constitutes the aim of the present study. Materials and methods: The electron eRT6/Oriatron/CHUV/5.5 MeV and proton Gantry1/PSI/170 MeV were used to deliver conventional (0.1 Gy/s eCONV and pCONV) and FLASH (≥100 Gy/s eFLASH and pFLASH) irradiation. Protons were delivered in transmission. Dosimetric and biologic intercomparisons were performed with previously validated models. Results: Doses measured at Gantry1 were in agreement (± 2.5%) with reference dosimeters calibrated at CHUV/IRA. The neurocognitive capacity of e and pFLASH irradiated mice was indistinguishable from the control while both e and pCONV irradiated cohorts showed cognitive decrements. Complete tumor response was obtained with the two beams and was similar between e and pFLASH vs. e and pCONV. Tumor rejection was similar indicating that T-cell memory response is beam-type and dose-rate independent. Conclusion: Despite major differences in the temporal microstructure, this study shows that dosimetric standards can be established. The sparing of brain function and tumor control produced by the two beams were similar, suggesting that the most important physical parameter driving the FLASH effect is the overall time of exposure which should be in the range of hundreds of milliseconds for WBI in mice. In addition, we observed that immunological memory response is similar between electron and proton beams and is independent off the dose rate.

7.
Phys Med Biol ; 68(9)2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-37019120

RESUMO

Objective.fast and accurate contouring of daily 3D images is a prerequisite for online adaptive radiotherapy. Current automatic techniques rely either on contour propagation with registration or deep learning (DL) based segmentation with convolutional neural networks (CNNs). Registration lacks general knowledge about the appearance of organs and traditional methods are slow. CNNs lack patient-specific details and do not leverage the known contours on the planning computed tomography (CT). This works aims to incorporate patient-specific information into CNNs to improve their segmentation accuracy.Approach.patient-specific information is incorporated into CNNs by retraining them solely on the planning CT. The resulting patient-specific CNNs are compared to general CNNs and rigid and deformable registration for contouring of organs-at-risk and target volumes in the thorax and head-and-neck regions.Results.patient-specific fine-tuning of CNNs significantly improves contour accuracy compared to standard CNNs. The method further outperforms rigid registration and a commercial DL segmentation software and yields similar contour quality as deformable registration (DIR). It is additionally 7-10 times faster than DIR.Significance.patient-specific CNNs are a fast and accurate contouring technique, enhancing the benefits of adaptive radiotherapy.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Neoplasias de Cabeça e Pescoço , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Algoritmos , Planejamento da Radioterapia Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação
8.
Phys Med Biol ; 68(10)2023 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-37084737

RESUMO

Background.At the Center for Proton Therapy at the Paul Scherrer Institute (PSI) the delivery of proton radiation is controlled via gas-based ionization chambers: the beam is turned off when a certain amount of preset charge has been collected. At low dose rates the charge collection efficiency in these detectors is unity, at ultra-high dose rates it is less due to induced charge recombination effects. If not corrected, the latter would lead to an overdosage.Purpose.In the scope of this work, we developed a novel approach to anin situcharge recombination correction for our dose defining detectors, when irradiated with a proton beam at ultra-high dose rates. This approach is based on the Two-Voltage-Method.Methods.We have translated this method to two separate devices operated simultaneously at different conditions. By doing so, the charge collection losses can be corrected directly and without the need for empirical correction values. This approach has been tested at ultra-high dose rates; proton beam was delivered by the COMET cyclotron to Gantry 1 at PSI.Results.We were able to correct the charge losses caused by recombination effects at local beam currents of approximately 700 nA (i.e. instantaneous dose rate of 3600 Gy s-1at isocenter). The corrected collected charges in our gaseous detectors were compared against recombination-free measurements with a Faraday cup. The ratio of both quantities shows no significant dose rate dependence within their respective combined uncertainties.Conclusions. Correcting recombination effects in our gas-based detectors with the novel method greatly eases the handling of Gantry 1 as 'FLASH test bench'. Not only is the application of a preset dose more accurate compared to using an empirical correction curve, also the re-determination of empirical correction curves in the case of a beam phase space change can be omitted.


Assuntos
Terapia com Prótons , Prótons , Radiometria/métodos , Terapia com Prótons/métodos , Ciclotrons , Radiação Ionizante
9.
Phys Med Biol ; 68(1)2022 12 26.
Artigo em Inglês | MEDLINE | ID: mdl-36571234

RESUMO

Objective.4D dose calculation (4DDC) for pencil beam scanned (PBS) proton therapy is typically based on phase-sorting of individual pencil beams onto phases of a single breathing cycle 4DCT. Understanding the dosimetric limitations and uncertainties of this approach is essential, especially for the realistic treatment scenario with irregular free breathing motion.Approach.For three liver and three lung cancer patient CTs, the deformable multi-cycle motion from 4DMRIs was used to generate six synthetic 4DCT(MRI)s, providing irregular motion (11/15 cycles for liver/lung; tumor amplitudes ∼4-18 mm). 4DDCs for two-field plans were performed, with the temporal resolution of the pencil beam delivery (4-200 ms) or with 8 phases per breathing cycle (500-1000 ms). For the phase-sorting approach, the tumor center motion was used to determine the phase assignment of each spot. The dose was calculated either using the full free breathing motion or individually repeating each single cycle. Additionally, the use of an irregular surrogate signal prior to 4DDC on a repeated cycle was simulated. The CTV volume with absolute dose differences >5% (Vdosediff>5%) and differences in CTVV95%andD5%-D95%compared to the free breathing scenario were evaluated.Main results.Compared to 4DDC considering the full free breathing motion with finer spot-wise temporal resolution, 4DDC based on a repeated single 4DCT resulted inVdosediff>5%of on average 34%, which resulted in an overestimation ofV95%up to 24%. However, surrogate based phase-sorting prior to 4DDC on a single cycle 4DCT, reduced the averageVdosediff>5%to 16% (overestimationV95%up to 19%). The 4DDC results were greatly influenced by the choice of reference cycle (Vdosediff>5%up to 55%) and differences due to temporal resolution were much smaller (Vdosediff>5%up to 10%).Significance.It is important to properly consider motion irregularity in 4D dosimetric evaluations of PBS proton treatments, as 4DDC based on a single 4DCT can lead to an underestimation of motion effects.


Assuntos
Neoplasias Pulmonares , Terapia com Prótons , Humanos , Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada Quadridimensional/métodos , Movimento (Física) , Terapia com Prótons/métodos , Respiração , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia
10.
Clin Oncol (R Coll Radiol) ; 33(12): e578-e585, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34340918

RESUMO

AIMS: Sacral chordomas are locally aggressive, radio-resistant tumours. Proton therapy has the potential to deliver high radiation doses, which may improve the therapeutic ratio when compared with conventional radiotherapy. We assessed tumour control and radiation-induced toxicity in a cohort of sacral chordoma patients treated with definitive or postoperative pencil beam scanning proton therapy. METHODS AND MATERIALS: Sixty patients with histologically proven sacral chordoma treated between November 1997 and October 2018 at the Paul Scherrer Institute with postoperative (n = 50) or definitive proton therapy (n = 10) were retrospectively analysed. Only 10 (17%) patients received combined photon radiotherapy and proton therapy. Survival rates were calculated using the Kaplan-Meier actuarial method. The Log-rank test was used to compare different functions for local control, freedom from distant recurrence and overall survival. Acute and late toxicity were assessed according to the Common Terminology Criteria for Adverse Events (CTCAE) v5.0. RESULTS: The median follow-up was 48 months (range 4-186). Local recurrence occurred in 20 (33%) patients. The 4-year local control, freedom from distant recurrence and overall survival rates were 77%, 89% and 85%, respectively. On univariate analysis, subtotal resection/biopsy (P = 0.02), tumour extension restricted to bone (P = 0.01) and gross tumour volume >130 ml (P = 0.04) were significant predictors for local recurrence. On multivariate analysis, tumour extension restricted to bone (P = 0.004) and gross total resection (P = 0.02) remained independent favourable prognostic factors for local recurrence. Twenty-four (40%), 28 (47%) and eight (11%) patients experienced acute grade 1, 2 and 3 toxicities, respectively. The 4-year late toxicity-free survival was 91%. Two patients developed secondary malignancies to the bladder 3-7 years after proton therapy. CONCLUSIONS: Our data indicate that pencil beam scanning proton therapy for sacral chordomas is both safe and effective. Gross total resection, tumour volume <130 ml and tumour restricted to the bone are favourable prognostic factors for local tumour control.


Assuntos
Cordoma , Terapia com Prótons , Neoplasias da Coluna Vertebral , Cordoma/radioterapia , Humanos , Recidiva Local de Neoplasia/radioterapia , Terapia com Prótons/efeitos adversos , Estudos Retrospectivos , Neoplasias da Coluna Vertebral/radioterapia , Carga Tumoral
11.
Radiat Oncol ; 16(1): 81, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33933118

RESUMO

INTRODUCTION: The current phase III EORTC 1420 Best-of trial (NCT02984410) compares the swallowing function after transoral surgery versus intensity modulated radiotherapy (RT) in patients with early-stage carcinoma of the oropharynx, supraglottis and hypopharynx. We report the analysis of the Benchmark Case (BC) procedures before patient recruitment with special attention to dysphagia/aspiration related structures (DARS). MATERIALS AND METHODS: Submitted RT volumes and plans from participating centers were analyzed and compared against the gold-standard expert delineations and dose distributions. Descriptive analysis of protocol deviations was conducted. Mean Sorensen-Dice similarity index (mDSI) and Hausdorff distance (mHD) were applied to evaluate the inter-observer variability (IOV). RESULTS: 65% (23/35) of the institutions needed more than one submission to achieve Quality assurance (RTQA) clearance. OAR volume delineations were the cause for rejection in 53% (40/76) of cases. IOV could be improved in 5 out of 12 OARs by more than 10 mm after resubmission (mHD). Despite this, final IOV for critical OARs in delineation remained significant among DARS by choosing an aleatory threshold of 0.7 (mDSI) and 15 mm (mHD). CONCLUSIONS: This is to our knowledge the largest BC analysis among Head and neck RTQA programs performed in the framework of a prospective trial. Benchmarking identified non-common OARs and target delineations errors as the main source of deviations and IOV could be reduced in a significant number of cases after this process. Due to the substantial resources involved with benchmarking, future benchmark analyses should assess fully the impact on patients' clinical outcome.


Assuntos
Benchmarking/métodos , Neoplasias Hipofaríngeas/radioterapia , Órgãos em Risco/efeitos da radiação , Neoplasias Orofaríngeas/radioterapia , Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Supraglotite/radioterapia , Ensaios Clínicos Fase III como Assunto , Humanos , Neoplasias Hipofaríngeas/patologia , Variações Dependentes do Observador , Neoplasias Orofaríngeas/patologia , Prognóstico , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Supraglotite/patologia
12.
Phys Med Biol ; 66(12)2021 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-33906166

RESUMO

Recently, proton therapy treatments delivered with ultra-high dose rates have been of high scientific interest, and the Faraday cup (FC) is a promising dosimetry tool for such experiments. Different institutes use different FC designs, and either a high voltage guard ring, or the combination of an electric and a magnetic field is employed to minimize the effect of secondary electrons. The authors first investigate these different approaches for beam energies of 70, 150, 230 and 250 MeV, magnetic fields between 0 and 24 mT and voltages between -1000 and 1000 V. When applying a magnetic field, the measured signal is independent of the guard ring voltage, indicating that this setting minimizes the effect of secondary electrons on the reading of the FC. Without magnetic field, applying the negative voltage however decreases the signal by an energy dependent factor up to 1.3% for the lowest energy tested and 0.4% for the highest energy, showing an energy dependent response. Next, the study demonstrates the application of the FC up to ultra-high dose rates. FC measurements with cyclotron currents up to 800 nA (dose rates of up to approximately 1000 Gy s-1) show that the FC is indeed dose rate independent. Then, the FC is applied to commission the primary gantry monitor for high dose rates. Finally, short-term reproducibility of the monitor calibration is quantified within single days, showing a standard deviation of 0.1% (one sigma). In conclusion, the FC is a promising, dose rate independent tool for dosimetry up to ultra-high dose rates. Caution is however necessary when using a FC without magnetic field, as a guard ring with high voltage alone can introduce an energy dependent signal offset.


Assuntos
Terapia com Prótons , Calibragem , Prótons , Radiometria , Reprodutibilidade dos Testes
13.
Radiologe ; 60(11): 1038-1046, 2020 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-33025131

RESUMO

CLINICAL/METHODICAL ISSUE: Oral cavity malignancies are the most common tumors in the field of ear, nose and throat medicine or otorhinolaryngology worldwide. It comprises a heterogeneous group of tumors, the knowledge of which is necessary to meet the different requirements of diagnostics and therapy. STANDARD RADIOLOGICAL METHODS: Computed tomography (CT), magnetic resonance imaging (MRI), sonography (US), nuclear medical procedures (NUK). PERFORMANCE: The above-mentioned diagnostics are used in a complementary manner. ACHIEVEMENTS: Early diagnosis of the tumor improves staging and thus the patient's therapy and prognosis. PRACTICAL RECOMMENDATIONS: The radiologist plays an important role in the interdisciplinary treatment of malignant tumors of the oral cavity. Despite great progress in radiotherapy, oncology and immunotherapy, surgery still plays an important role in the treatment of malignant diseases of the oral cavity.


Assuntos
Neoplasias Bucais , Tomografia Computadorizada por Raios X , Humanos , Imageamento por Ressonância Magnética , Neoplasias Bucais/diagnóstico por imagem , Neoplasias Bucais/patologia , Neoplasias Bucais/terapia , Estadiamento de Neoplasias , Prognóstico
14.
Cancer Radiother ; 24(6-7): 687-690, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32753239

RESUMO

Proton therapy is delivered to selected cancer patients presenting with rare tumours, for which a dose escalation paradigm and/or a reduced dose-bath to the organs at risk is pursued. It is a costly treatment with an additional cost factor of 2-3 when compared to photon radiotherapy. Notwithstanding the 180'000 patients treated with protons, scars robust clinical evidence is available to justify the administration of this treatment modality. The European Particle Therapy Network (EPTN) was created in 2015 to answer the critical European needs for cooperation among protons and carbon ions centres in the framework of clinical research networks. EPTN with other European groups will launch a number of prospective clinical trials that could be practice changing if positive. Alternative way to generate clinical data could be provided by alternative methodologies, such as the Dutch model-based approach, or could be provided by European infrastructure projects.


Assuntos
Neoplasias/radioterapia , Terapia com Prótons/tendências , Pesquisa Biomédica , Europa (Continente) , Previsões , Humanos
15.
Phys Med Biol ; 65(19): 195011, 2020 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-32575083

RESUMO

In daily adaptive proton therapy (DAPT), the treatment plan is re-optimized on a daily basis. It is a straightforward idea to incorporate information from the previous deliveries during the optimization to refine this daily proton delivery. A feedback signal was used to correct for delivery errors and errors from an inaccurate dose calculation used for plan optimization. This feedback signal consisted of a dose distribution calculated with a Monte Carlo algorithm and was based on the spot delivery information from the previous deliveries in the form of log-files. We therefore called the method Update On Yesterday's Dose (UYD). The UYD method was first tested with a simulated DAPT treatment and second with dose measurements using an anthropomorphic phantom. For both, the simulations and the measurements, a better agreement between the delivered and the intended dose distribution could be observed using UYD. Gamma pass rates (1%/1 mm) increased from around 75% to above 90%, when applying the closed-loop correction for the simulations, as well as the measurements. For a DAPT treatment, positioning errors or anatomical changes are incorporated during the optimization and therefore are less dominant in the overall dose uncertainty. Hence, the relevance of algorithm or delivery machine errors even increases compared to standard therapy. The closed-loop process described here is a method to correct for these errors, and potentially further improve DAPT.


Assuntos
Algoritmos , Imagens de Fantasmas , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/métodos , Humanos , Método de Monte Carlo , Dosagem Radioterapêutica
16.
Phys Med Biol ; 65(24): 245031, 2020 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-32315991

RESUMO

High-density materials, such as titanium, used for spinal stabilization, introduces several critical issues in proton therapy (PT). Artefacts affect both contouring and dose calculation. Subsequently, artefacts need to be corrected which is a time-consuming process. Besides, titanium causes proton interactions that are unaccounted for in dose calculation. The result is a suboptimal treatment plan, and indeed decreased local controls have been reported for these patients. Carbon fiber reinforced polyetheretherketone (CFR-PEEK) implant material, which is of low density, potentially solves these issues. For this study, we designed a unique phantom to compare the effects of titanium and CFR-PEEK implants in PT. The phantom contains four interchangeable spinal inserts representing a native spine, and three different spinal stabilizations consisting of titanium only, CFR-PEEK only, and a combination of titanium and CFR-PEEK. All phantom scenarios received the standard treatment workup. Two planning approaches were investigated: a single field plan and a multi-field optimized plan with spinal cord sparing. For both plans we analyzed the following aspects: total volume of artefacts on CT images, time required for artefact correction, effect of planning CT correction on dose calculation, plan robustness to range and set up uncertainties, and finally the discrepancy between the calculated dose and the delivered dose with Gafchromic® film. The CFR-PEEK implant had a 90% reduction of artefacts on CT images and subsequently severely reduced the time for artefact correction with respect to the titanium-only implant. Furthermore, the CFR-PEEK as opposed to titanium did not influence the robustness of the plan. Finally, the titanium implants led to hardware-related discrepancies between the planned and the measured dose while the CFR-PEEK implant showed good agreement. As opposed to titanium, CFR-PEEK has none to minor effects on PT. The use of CFR-PEEK is expected to optimize treatment and possibly improve outcomes for patients that require spinal stabilization.


Assuntos
Fibra de Carbono/química , Cetonas/química , Imagens de Fantasmas , Polietilenoglicóis/química , Próteses e Implantes , Terapia com Prótons/métodos , Neoplasias da Coluna Vertebral/radioterapia , Titânio/química , Benzofenonas , Humanos , Polímeros , Planejamento da Radioterapia Assistida por Computador
17.
Clin Oncol (R Coll Radiol) ; 32(8): 537-544, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32222414

RESUMO

AIMS: The outcome of chordoma patients with local or distant failure after proton therapy is not well established. We assessed the disease-specific (DSS) and overall survival of patients recurring after proton therapy and evaluated the prognostic factors affecting DSS. MATERIALS AND METHODS: A retrospective analysis was carried out of 71 recurring skull base (n = 36) and extracranial (n = 35) chordoma patients who received adjuvant proton therapy at initial presentation (n = 42; 59%) or after post-surgical recurrence (n = 29; 41%). The median proton therapy dose delivered was 74 GyRBE (range 62-76). The mean age was 55 ± 14.2 years and the male/female ratio was about one. RESULTS: The median time to first failure after proton therapy was 30.8 months (range 3-152). Most patients (n = 59; 83%) presented with locoregional failure only. There were only 12 (17%) distant failures, either with (n = 5) or without (n = 7) synchronous local failure. Eight patients (11%) received no salvage therapy for their treatment failure after proton therapy. Salvage treatments after proton therapy failure included surgery, systemic therapy and additional radiotherapy in 45 (63%), 20 (28%) and eight (11%) patients, respectively. Fifty-three patients (75%) died, most often from disease progression (47 of 53 patients; 89%). The median DSS and overall survival after failure was 3.9 (95% confidence interval 3.1-5.1) and 3.4 (95% confidence interval 2.5-4.4) years, respectively. On multivariate analysis, extracranial location and late failure (≥31 months after proton therapy) were independent favourable prognostic factors for DSS. CONCLUSION: The survival of chordoma patients after a treatment failure following proton therapy is poor, particularly for patients who relapse early or recur in the skull base. Although salvage treatment is administered to most patients with uncontrolled disease, they will ultimately die as a result of disease progression in most cases.


Assuntos
Cordoma/mortalidade , Recidiva Local de Neoplasia/mortalidade , Terapia com Prótons/mortalidade , Terapia de Salvação , Procedimentos Cirúrgicos Operatórios/mortalidade , Cordoma/patologia , Cordoma/radioterapia , Cordoma/cirurgia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/etiologia , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/cirurgia , Prognóstico , Terapia com Prótons/efeitos adversos , Estudos Retrospectivos
18.
Clin Oncol (R Coll Radiol) ; 32(7): 467-476, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32081577

RESUMO

AIMS: More efforts are required to minimise late radiation side-effects for paediatric patients. Pencil beam scanning proton beam therapy (PBS-PT) allows increased sparing of normal tissues while maintaining conformality, but is prone to dose degradation from interplay effects due to respiratory motion. We report our clinical experience of motion mitigation with volumetric rescanning (vRSC) and outcomes of children with neuroblastoma. MATERIALS AND METHODS: Nineteen patients with high-risk (n = 16) and intermediate-risk (n = 3) neuroblastoma received PBS-PT. The median age at PBS-PT was 3.5 years (range 1.2-8.6) and the median PBS-PT dose was 21 Gy (relative biological effectiveness). Most children (89%) were treated under general anaesthesia. Seven patients (37%) underwent four-dimensional computed tomography for motion assessment and were treated with vRSC for motion mitigation. RESULTS: The mean result of maximum organ motion was 2.7 mm (cranial-caudal), 1.2 mm (left-right), 1.0 mm (anterior-posterior). Four anaesthetised children (21%) showing <5 mm motion had four-dimensional dose calculations (4DDC) to guide the number of vRSC. The mean deterioration or improvement to the planning target volume covered by 95% of the prescribed dose compared with static three-dimensional plans were: 4DDC no vRSC, -0.6%; 2 vRSC, +0.3%; 4 vRSC, +0.3%; and 8 vRSC, +0.1%. With a median follow-up of 14.9 months (range 2.7-49.0) there were no local recurrences. The 2-year overall survival was 94% and distant progression-free survival was 76%. Acute grade 2-4 toxicity was 11%. During the limited follow-up time, no late toxicities were observed. CONCLUSIONS: The early outcomes of mainly high-risk patients with neuroblastoma treated with PBS-PT were excellent. With a subset of our cohort undergoing PBS-PT with vRSC we have shown that it is logistically feasible and safe. The clinical relevance of vRSC is debatable in anaesthetised children with small pre-PBS-PT motion of <5 mm.


Assuntos
Neuroblastoma/radioterapia , Movimentos dos Órgãos , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Criança , Pré-Escolar , Feminino , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Lactente , Masculino , Neuroblastoma/diagnóstico por imagem , Neuroblastoma/patologia , Eficiência Biológica Relativa
19.
Phys Med Biol ; 64(9): 095005, 2019 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-30893664

RESUMO

The literature is controversial about the scan direction dependency of interplay effects in pencil beam scanning (PBS) treatment of moving targets. A directional effect is supported by many simulation studies, whereas the experimental data are mostly limited to simple geometries, not reflecting realistically clinical treatment plans. We have compared increasingly complex treatment fields, from a homogeneous single energy layer to a more modulated lung plan, under identical experimental settings, seeking evidence for differences in motion mitigation due to the selection of primary scanning direction. In total, 120 experimental samples were taken, combining two primary scan directions and three rescanning regimes with different motion scenarios. 4D dose distributions were measured in water with a moving ionisation chamber array and compared to those of a stationary delivery using 2D gamma analysis. Each plan has been verified twice for the same rescanning regime and motion scenario, changing the meandering direction in between to scan perpendicularly to, or along, the target motion. Additionally, machine log files of the lung plan, together with 4DCT data, were used to calculate the dose distribution that such deliveries would have produced in the patient. The primary meandering direction has a clear influence on measured dose distributions when considering a single energy layer. Introducing spot weight modulation and multiple energy layers however, makes the dynamic of interplay more complex and difficult to predict. Overall, gamma (3%/3 mm) differences between scanning along or orthogonal to the target motion follow a normal distribution [Formula: see text] when considering multiple motion scenarios and rescanning regimes. Nevertheless, data spread [Formula: see text] is significant enough such that, for individual experiments and set-ups, a dependency may be observed even if this is not a general result. Patient reconstructed doses follow the same trend, the two primary scan directions producing statistically insignificant differences in dose distributions in terms of conformity or homogeneity. Except for extremely simplified cases of mono-energetic and homogeneous treatment fields, the interplay effect has been found to be only marginally influenced by the choice of the primary scanning direction.


Assuntos
Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada Quadridimensional , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/fisiopatologia , Neoplasias Hepáticas/radioterapia , Movimento , Dosagem Radioterapêutica
20.
Phys Med Biol ; 63(20): 205014, 2018 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-30234498

RESUMO

Patient specific verification (PSV) measurements for pencil beam scanning (PBS) proton therapy are resource-consuming and necessitate substantial beam time outside of clinical hours. As such, efforts to safely reduce the PSV-bottleneck in the clinical work-flow are of great interest. Here, capabilities of current PSV methods to ensure the treatment integrity were investigated and compared to an alternative approach of reconstructing the dose distribution directly from the machine control- or delivery log files with the help of an independent dose calculation (IDC). Scenarios representing a wide range of delivery or work-flow failures were identified (e.g. error in spot position, air gap or pre-absorber setting) and machine files were altered accordingly. This yielded 21 corrupted treatment files, which were delivered and measured with our clinical PSV protocol. IDC machine- and log file checks were also conducted and their sensitivity at detecting the errors compared to the measurements. Although some of the failure scenarios induced clinically relevant dose deviations in the patient geometry, the PSV measurement protocol only detected one out of 21 error scenarios. However, 11 and all 21 error scenarios were detected using dose reconstructions based on the log and machine files respectively. Our data suggests that, although commonly used in particle therapy centers, PSV measurements do a poor job detecting data transfer failures and imperfect delivery machine performance. Machine- and log-file IDCs have been shown to successfully detect erroneous work-flows and to represent a reliable addition to the QA procedure, with the potential to replace PSV.


Assuntos
Medicina de Precisão , Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia , Humanos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada