Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Radiology ; 308(3): e230427, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37750774

RESUMO

Background Deep learning (DL) reconstructions can enhance image quality while decreasing MRI acquisition time. However, DL reconstruction methods combined with compressed sensing for prostate MRI have not been well studied. Purpose To use an industry-developed DL algorithm to reconstruct low-resolution T2-weighted turbo spin-echo (TSE) prostate MRI scans and compare these with standard sequences. Materials and Methods In this prospective study, participants with suspected prostate cancer underwent prostate MRI with a Cartesian standard-resolution T2-weighted TSE sequence (T2C) and non-Cartesian standard-resolution T2-weighted TSE sequence (T2NC) between August and November 2022. Additionally, a low-resolution Cartesian DL-reconstructed T2-weighted TSE sequence (T2DL) with compressed sensing DL denoising and resolution upscaling reconstruction was acquired. Image sharpness was assessed qualitatively by two readers using a five-point Likert scale (from 1 = nondiagnostic to 5 = excellent) and quantitatively by calculating edge rise distance. The Friedman test and one-way analysis of variance with post hoc Bonferroni and Tukey tests, respectively, were used for group comparisons. Prostate Imaging Reporting and Data System (PI-RADS) score agreement between sequences was compared by using Cohen κ. Results This study included 109 male participants (mean age, 68 years ± 8 [SD]). Acquisition time of T2DL was 36% and 29% lower compared with that of T2C and T2NC (mean duration, 164 seconds ± 20 vs 257 seconds ± 32 and 230 seconds ± 28; P < .001 for both). T2DL showed improved image sharpness compared with standard sequences using both qualitative (median score, 5 [IQR, 4-5] vs 4 [IQR, 3-4] for T2C and 4 [IQR, 3-4] for T2NC; P < .001 for both) and quantitative (mean edge rise distance, 0.75 mm ± 0.39 vs 1.15 mm ± 0.68 for T2C and 0.98 mm ± 0.65 for T2NC; P < .001 and P = .01) methods. PI-RADS score agreement between T2NC and T2DL was excellent (κ range, 0.92-0.94 [95% CI: 0.87, 0.98]). Conclusion DL reconstruction of low-resolution T2-weighted TSE sequences enabled accelerated acquisition times and improved image quality compared with standard acquisitions while showing excellent agreement with conventional sequences for PI-RADS ratings. Clinical trial registration no. NCT05820113 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Turkbey in this issue.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Humanos , Masculino , Idoso , Imageamento por Ressonância Magnética , Estudos Prospectivos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia
2.
Eur J Radiol ; 163: 110831, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37059004

RESUMO

PURPOSE: To compare standard breath-hold (BH) cine imaging to a radial pseudo-golden-angle free-breathing (FB) technique in congenital heart disease (CHD). METHODS: In this prospective study, short-axis and 4-chamber BH and FB cardiac MRI sequences of 25 participants with CHD acquired at 1.5 Tesla, were quantitatively compared regarding ventricular volumes, function, interventricular septum thickness (IVSD), apparent signal to noise ratio (aSNR), and estimated contrast to noise ratio (eCNR). For qualitative comparison, three image quality criteria (contrast, endocardial edge definition, and artefacts) were rated on a 5-point Likert scale (5: excellent, 1: non-diagnostic). Paired t-Test was used for group comparisons, Bland-Altman analysis for agreement between techniques. Inter-reader agreement was compared using intraclass correlation coefficient. RESULTS: IVSD (BH 7.4 ± 2.1 mm vs FB 7.4 ± 1.9 mm, p =.71), biventricular ejection fraction (left ventricle [LV]: 56.4 ± 10.8% vs 56.1 ± 9.3%, p =.83; right ventricle [RV]: 49.5 ± 8.6% vs 49.7 ± 10.1%, p =.83), and biventricular end diastolic volume (LV: 176.3 ± 63.9 ml vs 173.9 ± 64.9 ml, p =.90; RV: 185.4 ± 63.8 ml vs 189.6 ± 66.6 ml, p =.34) were comparable. Mean measurement time for FB short-axis sequences was 8.1 ± 1.3 compared to 4.4 ± 1.3 min for BH (p <.001). Subjective image quality between sequences was deemed comparable, (4.6 ± 0.6 vs 4.5 ± 0.6, p =.26, for 4-chamber views) with a significant difference regarding short-axis views (4.9 ± 0.3 vs 4.5 ± 0.6, p =.008). aSNR was similar (BH 25.8 ± 11.2 vs FB 22.2 ± 9.5, p =.24), while eCNR was higher for BH (89.1 ± 36.1 vs 68.5 ± 32.1, p =.03). CONCLUSION: FB sequences yielded comparable results to BH regarding image quality, biventricular volumetry, and function, though measurement times were longer. The FB sequence described might be clinically valuable when BHs are insufficiently performed.


Assuntos
Cardiopatias Congênitas , Respiração , Humanos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Suspensão da Respiração , Reprodutibilidade dos Testes
3.
Invest Radiol ; 58(3): 209-215, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36070533

RESUMO

OBJECTIVES: The aim of this study was to compare a new compressed sensing (CS) method for T2-weighted propeller acquisitions (T2 CS ) with conventional T2-weighted propeller sequences (T2 conv ) in terms of achieving a higher image quality, while reducing the acquisition time. MATERIALS AND METHODS: Male participants with a clinical suspicion of prostate cancer were prospectively enrolled and underwent prostate magnetic resonance imaging at 3 T. Axial and sagittal images of the T2 conv sequence and the T2 CS sequence were acquired. Sequences were qualitatively assessed by 2 blinded radiologists concerning artifacts, image-sharpness, lesion conspicuity, capsule delineation, and overall image quality using 5-point Likert items ranging from 1 (nondiagnostic) to 5 (excellent). The apparent signal-to-noise ratio and apparent contrast-to-noise ratio were evaluated. PI-RADS scores were assessed for both sequences. Statistical analysis was performed by using Wilcoxon signed rank test and paired samples t test. Intrarater and interrater reliability of qualitative image evaluation was assessed using intraclass correlation coefficient (ICC) estimates. RESULTS: A total of 29 male participants were included (mean age, 66 ± 8 years). The acquisition time of the T2 CS sequence was respectively 26% (axial plane) and 24% (sagittal plane) shorter compared with the T2 conv sequence (eg, axial: 171 vs 232 seconds; P < 0.001). In the axial plane, the T2 CS sequence had fewer artifacts (4 [4-4.5] vs 4 [3-4]; P < 0.001), better image-sharpness (4 [4-4.5] vs 3 [3-3.5]; P < 0.001), better capsule delineation (4 [3-4] vs 3 [3-3.5]; P < 0.001), and better overall image quality (4 [4-4] vs 4 [3-4]; P < 0.001) compared with the T2 conv sequence. The ratings of lesion conspicuity were similar (4 [4-4] vs 4 [3-4]; P = 0.166). In the sagittal plane, the T2 CS sequence outperformed the T2 conv sequence in the categories artifacts (4 [4-4] vs 3 [3-4]; P < 0.001), image sharpness (4 [4-5] vs 4 [3-4]; P < 0.001), lesion conspicuity (4 [4-4] vs 4 [3-4]; P = 0.002), and overall image quality (4 [4-4] vs 4 [3-4]; P = 0.002). Capsule delineation was similar between both sequences (3 [3-4] vs 3 [3-3]; P = 0.07). Intraobserver and interobserver reliability for qualitative scoring were good (ICC intra: 0.92; ICC inter: 0.86). Quantitative analysis revealed a higher apparent signal-to-noise ratio (eg, axial: 52.2 ± 9.7 vs 22.8 ± 3.6; P < 0.001) and a higher apparent contrast-to-noise ratio (eg, axial: 44.0 ± 9.6 vs 18.6 ± 3.7; P ≤ 0.001) of the T2 CS sequence. PI-RADS scores were the same for both sequences in all participants. CONCLUSIONS: CS-accelerated T2-weighted propeller acquisition had a superior image quality compared with conventional T2-weighted propeller sequences while significantly reducing the acquisition time.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes , Neoplasias da Próstata/diagnóstico por imagem , Razão Sinal-Ruído , Artefatos
4.
PLoS One ; 7(10): e43402, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23082108

RESUMO

INTRODUCTION: Developments in telemedicine have not produced any relevant benefits for orthopedics and trauma surgery to date. For the present project study, several parameters were examined during assessment of x-ray images, which had been photographed and transmitted via cell phone. MATERIALS AND METHODS: A total of 100 x-ray images of various body regions were photographed with a Nokia cell phone and transmitted via email or MMS. Next, the transmitted photographs were reviewed on a laptop computer by five medical specialists and assessed regarding quality and diagnosis. RESULTS: Due to their poor quality, the transmitted MMS images could not be evaluated and this path of transmission was therefore excluded. Mean size of transmitted x-ray email images was 394 kB (range: 265-590 kB, SD ± 59), average transmission time was 3.29 min ± 8 (CI 95%: 1.7-4.9). Applying a score from 1-10 (very poor - excellent), mean image quality was 5.8. In 83.2 ± 4% (mean value ± SD) of cases (median 82; 80-89%), there was agreement between final diagnosis and assessment by the five medical experts who had received the images. However, there was a markedly low concurrence ratio in the thoracic area and in pediatric injuries. DISCUSSION: While the rate of accurate diagnosis and indication for surgery was high with a concurrence ratio of 83%, considerable differences existed between the assessed regions, with lowest values for thoracic images. Teleradiology is a cost-effective, rapid method which can be applied wherever wireless cell phone reception is available. In our opinion, this method is in principle suitable for clinical use, enabling the physician on duty to agree on appropriate measures with colleagues located elsewhere via x-ray image transmission on a cell phone.


Assuntos
Telefone Celular , Fotografação/instrumentação , Fotografação/normas , Telerradiologia/métodos , Telerradiologia/normas , Criança , Humanos , Reprodutibilidade dos Testes , Raios X
5.
Int Orthop ; 36(7): 1463-9, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22358174

RESUMO

PURPOSE: Medial femoral neck fractures are common, and closed reduction and internal fixation by three cannulated screws is an accepted method for the surgical treatment. Computer navigation for screw placement may reduce fluoroscopy time, the number of guidewire passes and optimise screw placement. METHODS: In the context of a sawbone study, a computer-assisted planning and navigation system based on 3D-imaging for guidewire placement in the femoral neck was tested to improve screw placement. Three screws were inserted into 12, intact, femoral sawbones using the conventional technique and into 12, intact, femoral sawbones guided by the computer-based navigation system. Guidewire and subsequent screw placement in the femoral neck were evaluated. RESULTS: Use of the navigation system resulted in a significant reduction of the number of drilling attempts (p≤0.05) and achieved optimised accuracy of implant placement by attaining significantly better screw parallelism (p≤0.05) and significantly enlarged neck-width coverage by the three screws (p≤0.0001). Computer assistance significantly increased the number of fluoroscopic images (p≤0.001) and the operation time (p≤0.0001). CONCLUSIONS: Three-dimensional computer-assisted navigation improves accuracy of cannulated screw placement in femoral neck while increasing the number of fluoroscopic images and operation time. Additional studies including fractured sawbones and cadaver models with the goal of reducing operation time are indispensable before introduction of this navigation system into clinical practice.


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Articulação do Quadril/cirurgia , Teste de Materiais , Implantação de Prótese/métodos , Cirurgia Assistida por Computador/métodos , Fraturas do Colo Femoral/cirurgia , Fixação Interna de Fraturas/instrumentação , Modelos Biológicos , Projetos Piloto
6.
Acta Orthop ; 82(4): 489-93, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21657968

RESUMO

BACKGROUND: Despite the fact that C-reactive protein (CRP) levels and white blood cell (WBC) count are routine blood chemistry parameters for the early assessment of wound infection after surgical procedures, little is known about the natural history of their serum values after major and minimally invasive spinal procedures. METHODS: Pre- and postoperative CRP serum levels and WBC count in 347 patients were retrospectively assessed after complication-free, single-level open posterior lumbar interlaminar fusion (PLIF) (n = 150) for disc degeneration and spinal stenosis and endoscopically assisted lumbar discectomy (n = 197) for herniated lumbar disc. Confounding variables such as overweight, ASA classification, arterial hypertension, diabetes mellitus, and perioperative antibiotics were recorded to evaluate their influence on the kinetics of CRP values and WBC count postoperatively. RESULTS: In both procedures, CRP peaked 2-3 days after surgery. The maximum CRP level was significantly higher after fusion: mean 127 (SD 57) (p < 0.001). A rapid fall in CRP within 4-6 days was observed for both groups, with almost normal values being reached after 14 days. Only BMI > 25 and long duration of surgery were associated with higher peak CRP values. WBC count did not show a typical and therefore interpretable profile. CONCLUSION: CRP is a predictable and responsive serum parameter in postoperative monitoring of inflammatory responses in patients undergoing spine surgery, whereas WBC kinetics is unspecific. We suggest that CRP could be measured on the day before surgery, on day 2 or 3 after surgery, and also between days 4 and 6, to aid in early detection of infectious complications.


Assuntos
Proteína C-Reativa/análise , Discotomia Percutânea , Contagem de Leucócitos , Vértebras Lombares/cirurgia , Fusão Vertebral , Adulto , Idoso , Antibacterianos/administração & dosagem , Discotomia Percutânea/efeitos adversos , Feminino , Humanos , Degeneração do Disco Intervertebral/cirurgia , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Valor Preditivo dos Testes , Estudos Retrospectivos , Fusão Vertebral/efeitos adversos , Estenose Espinal/cirurgia , Infecção da Ferida Cirúrgica/sangue , Infecção da Ferida Cirúrgica/tratamento farmacológico , Infecção da Ferida Cirúrgica/prevenção & controle
7.
Oper Orthop Traumatol ; 21(6): 586-601, 2009 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-20087719

RESUMO

OBJECTIVE: Objective Bone-preserving hip resurfacing in young and active patients using a soft-tissue-sparing, modified transgluteal, lateral approach. INDICATIONS: Primary hip osteoarthritis in physically active, working patients aged < 65 years (males) and < 60 years (females). Good bone quality. CONTRAINDICATIONS: Male patients > or = 65 years of age, female patients > or = 60 years of age. Necrosis of the femoral head. Varus deformity of the femoral neck with a reduced horizontal femoral offset. Femoral head cysts (> 1 cm in diameter). Infection. Osteoporosis. Rheumatoid arthritis. Tumor. Reduced renal function. Leg length difference (> or = 1 cm). Metal allergy. Previous femoral neck fracture. Previous intertrochanteric femoral osteotomies. SURGICAL TECHNIQUE: Supine position of the patient. Modified transgluteal, lateral approach to the hip joint. Luxation of the femoral head. First, reaming of the femoral head to improve visualization of the acetabular cup. Central positioning of the guide wire in the femoral neck in a slight valgus position of approximately +5 degrees to the anatomic collodiaphyseal (CCD) angle using the mechanical targeting device. Overdrilling of the central guide wire to the appropriate depth for the implant. Central insertion of the guide rod. Preparation of the femoral head over the guide rod using cylinder cutters one or two sizes larger than the smallest possible femoral component. Cement-free implantation of the acetabular component according to the predetermined definitive size of the femoral component. Final preparation of the femoral head using profile, surface and forming cutter. Following cemented implantation of the femoral component, repositioning of the hip joint and conclusion of the surgical procedure. POSTOPERATIVE MANAGEMENT: Mobilization of the patient using two forearm crutches as of the 1st day after surgery. Removal of the Redon drains after 24 h. Partial weight bearing of 20 kg for 3 weeks under continuation of thrombosis prophylaxis. Limitation of hip flexion to 90 degrees during the first 6 postoperative weeks, and no adduction and forced external rotation allowed in order to avoid luxation. Avoidance of sports involving the loads of jumping and axial impact loading for 12 postoperative months. RESULTS: Analysis involved the pre- and postoperative functions of 72 patients with a total of 82 prostheses and a mean durability time of 29.2 +/- 11 months based on the Harris Hip Score (HHS), the modified UCLA (University of California, Los Angeles) activity index, and the Merle d'Aubigné Score. Postoperatively, prosthetic angle and femoral offset as well as periprosthetic signs of loosening/lytic areas were assessed by means of radiology and compared with the preoperative CCD angle and femoral offset. Compared to the preoperative evaluation, follow-up yielded a significant increase in the average HHS values (94 +/- 4.6 vs. 40.1 +/- 7 points), the modified UCLA activity index (8.9 +/- 2.6 vs. 4.6 +/- 2.2), and the Merle d'Aubigné Score (17.9 +/- 1.9 vs. 7.3 +/- 2.4; p < or = 0.05). In 98.8%, a solid osteointegration of the cup and femoral components was observed. The average deviation of the physiological CCD angle (136.6 degrees +/- 3.6 degrees ) from the postoperative angle of the prosthesis (142.6 degrees +/- 4.9 degrees ) was 6 degrees +/- 2.8 degrees . The postoperative femoral offset was reduced by an average of 2.3 mm compared to the preoperative offset. During clinical follow-up n = 2 prostheses (2.5%) required revision (one femoral neck fracture; one periarticular ossification [Brooker III]).


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Cabeça do Fêmur/cirurgia , Prótese de Quadril , Instabilidade Articular/cirurgia , Osteoartrite do Quadril/cirurgia , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Instabilidade Articular/diagnóstico , Instabilidade Articular/etiologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/complicações , Osteoartrite do Quadril/diagnóstico , Amplitude de Movimento Articular , Reoperação , Resultado do Tratamento
8.
J Shoulder Elbow Surg ; 18(1): 75-82, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19095179

RESUMO

The goal of this study was to determine functional results of hemiarthroplasty for 3- and 4-part proximal humeral fractures in elderly patients and to analyze factors affecting the outcome. Thirty-eight consecutive shoulders were treated with hemiarthroplasty after proximal humeral fracture. Two groups of patients with different health status were classified. Group I consisted of patients with 2 or less comorbidities and a maximum of 2 medications at the time of injury. Patients in group II had 3 or more comorbidities with a minimum of 3 medications at the time of injury. The mean of the absolute Constant score in group I was 41, compared to 27 in group II (P < .05). Furthermore, compliance of the patient and regular physiotherapy proved to be important prognostic factors. If primary hemiarthroplasty is not likely to be successful with a low functional score, this surgical procedure should be reconsidered especially in patients with more than three comorbidities.


Assuntos
Artroplastia de Substituição/métodos , Nível de Saúde , Fraturas do Úmero/cirurgia , Articulação do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Lesões do Ombro , Resultado do Tratamento
9.
Acta Derm Venereol ; 88(6): 555-60, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19002338

RESUMO

Polymorphic light eruption (PLE), with an overall prevalence of 10-20%, is mainly provoked by ultraviolet A (UVA) (320-400 nm) and to a lesser degree by UVB (280-320 nm). The most effective prophylaxis of PLE, application of UV protection clothing, is not feasible for all sun-exposed areas of the skin and UV-hardening is time-consuming and may be associated with side-effects. Most sunscreens protect predominantly against UVB and therefore fail to prevent PLE. The protection level of potent UVA-protective filters remains unresolved. This single-centre, open, placebo-controlled, intra-individual, comparative study, analysed the efficacy of a sunscreen of very high protection level against UVB and UVA, containing methylene bis-benzotriazolyl tetramethylbutylphenol (Tinosorb M), bis-ethylhexyloxyphenol methoxyphenyl triazine (Tinosorb S) and butyl methoxydibenzoylmethane as UVA absorbing filters, in the prevention of PLE under standardized photodiagnostic conditions. After determination of the minimal erythema dose at day 0, photoprovocation was performed in 12 patients with a clinical history of PLE, on days 1, 2 and 3 with 100 J/cm2 UVA and variable doses of UVB, starting with the 1.5-fold minimal erythema dose of UVB. Prior to irradiation, placebo was applied to the right and sunscreen to the left dorsal forearm under COLIPA (European Cosmetic, Toiletry and Perfumery Association) conditions. In 10 patients PLE could be provoked at the placebo site, with positive reactions in 90% of the UVA, 40% of the UVB and 90% of the UVA/UVB irradiated fields. At the site with the active treatment none of these patients developed PLE. These data demonstrate that a sunscreen with effective filters against UVA and UVB can successfully prevent the development of PLE. Further studies are needed to examine whether regular application of sunscreen under everyday conditions, especially in doses less than the tested COLIPA-norm, could be an equivalent alternative to UV-hardening therapy.


Assuntos
Transtornos de Fotossensibilidade/prevenção & controle , Protetores Solares/uso terapêutico , Raios Ultravioleta/efeitos adversos , Alcanos/análise , Alcanos/uso terapêutico , Chalconas/análise , Chalconas/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fenóis/análise , Fenóis/uso terapêutico , Propiofenonas , Protetores Solares/química , Triazinas/análise , Triazinas/uso terapêutico
10.
Eur J Trauma Emerg Surg ; 34(5): 443, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26815988

RESUMO

OBJECTIVE: Paramedics and physicians are important components of our emergency medical system. To date, no survey has been carried out assessing physicians and paramedics regarding their preparedness for a mass casualty incident (MCI) resulting from a terrorist attack in Germany. The aim of this study was to assess the current state of preparedness of emergency physicians and paramedics for an MCI. MATERIALS AND METHODS: Using an online questionnaire, we interviewed 1,707 emergency physicians and paramedics in Germany. The replies were analyzed statistically with the one-way analysis of variance (ANOVA) test and the Tukey-Kramer multiple comparisons test. RESULTS: In all, 95% of the emergency physicians and paramedics knew their area of responsibility in the case of an MCI. However, 45% of them were unaware of injury patterns and treatment strategies in patients following nuclear, chemical or biological contamination. Of the interviewed emergency physicians and paramedics, 97% asked for further specific training for MCI/terrorism attacks. CONCLUSIONS: Emergency physicians and paramedics are still insufficiently prepared for nuclear, chemical, and biological as well as conventional terrorism attacks. The emergency training of emergency physicians and paramedics must be modified to accommodate the increased risk of catastrophes and terrorist attacks.

11.
Radiology ; 243(2): 451-60, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17384240

RESUMO

PURPOSE: To prospectively determine in swine the effects of cardiac-specific and hypoxia-inducible vascular endothelial growth factor (VEGF) expression gene on angiogenesis and arteriogenesis by using cardiovascular magnetic resonance (MR) imaging for evaluation of infarct resorption and left ventricular (LV) function. MATERIALS AND METHODS: The investigation conformed to U.S. National Institutes of Health guidelines. Twelve pigs with reperfused infarcts were studied with cardiovascular MR 3 days and 8 weeks after surgery. In six pigs, adeno-associated viral (AAV) vector-encoding VEGF (AAV-VEGF) gene was injected at eight sites 1 hour after reperfusion. Six pigs served as controls. Cardiovascular MR measurements of perfusion, area at risk, infarct size, and LV function were used in evaluation of the therapy. Hematoxylin-eosin, Masson trichrome, and biotinylated isolectin B4 stains were used to assess regional vascular density. Two-way Student t test was used to determine significant differences between means. RESULTS: AAV-VEGF had no effect on cardiovascular MR perfusion or infarct size measurements 3 days after infarction. At 8 weeks, the therapy increased infarct resorption, perfusion, and vascular density and prevented deterioration of ejection fraction in treated animals. These changes were associated with a significantly greater reduction in extent of enhanced region in treated (18.6% of LV surface area +/- 1.5 [standard error of mean] to 9.8% +/- 1.1) than in control animals (17.7% +/- 1.8 to 14.5% +/- 1.5, P = .028). Histopathologic findings in treated animals showed increased capillary and arterial density in infarct and periinfarct regions. These new vessels were active and thin-walled compared with thick-walled vessels of control animals. CONCLUSION: AAV-VEGF improves cardiovascular MR measurement of regional myocardial perfusion and LV function.


Assuntos
Adenoviridae/genética , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Fator A de Crescimento do Endotélio Vascular/uso terapêutico , Fatores de Crescimento do Endotélio Vascular/uso terapêutico , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/terapia , Animais , Vetores Genéticos , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/genética , Suínos , Transfecção/métodos , Resultado do Tratamento , Fator A de Crescimento do Endotélio Vascular/genética , Fatores de Crescimento do Endotélio Vascular/genética , Disfunção Ventricular Esquerda/genética
12.
Magn Reson Med ; 54(5): 1107-14, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16206144

RESUMO

A methodology is presented for placing deep brain stimulator electrodes under direct MR image guidance. The technique utilized a small, skull-mounted trajectory guide that is optimized for accurate alignment under MR fluoroscopy. Iterative confirmation scans are used to monitor device alignment and brain penetration. The methodology was initially tested in a human skull phantom and proved capable of achieving submillimeter accuracy over a set of 16 separate targets that were accessed. The maximum error that was obtained in this preliminary test was 2 mm, motivating use of the technique in a clinical study. Subsequently, a total of eight deep brain stimulation electrodes were placed in five patients. Satisfactory placement was achieved on the first pass in seven of eight electrodes, while two passes were required with one electrode. Mean error from the intended target on the first pass was 1.0 +/- 0.8 mm (range = 0.1-1.9 mm). All procedures were considered technical successes and there were no intraoperative complications; however, one patient did develop a postoperative infection.


Assuntos
Encéfalo/patologia , Estimulação Encefálica Profunda/métodos , Eletrodos Implantados , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Implantação de Prótese/métodos , Cirurgia Assistida por Computador/métodos , Encéfalo/cirurgia , Sistemas Computacionais , Estimulação Encefálica Profunda/instrumentação , Campos Eletromagnéticos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Acad Radiol ; 9(10): 1179-84, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12385512

RESUMO

RATIONALE AND OBJECTIVES: The authors performed this study to evaluate the feasibility of using the steady-state free precession (SSFP) sequence to perform magnetic resonance (MR) venography of the portal venous system without the use of contrast material or breath holding. MATERIALS AND METHODS: Eleven patients underwent MR venography with the SSFP technique. Coronal three-dimensional images were obtained with respiratory triggering. Contrast material and respiratory suspension were not used. All patients had recently undergone at least one other imaging study (conventional angiography, transhepatic portal venography, ultrasound, or contrast-enhanced computed tomography), and these findings were correlated with those from MR venography. The structures evaluated were the main portal vein, right portal vein, left portal vein, superior mesenteric vein, and splenic vein. RESULTS: MR venography with SSFP accurately depicted the status of these veins in all cases except one. In this patient, MR venography depicted portal vein thrombus but could not indicate that it was tumor thrombus. CONCLUSION: MR venography with SSFP accurately depicted the portal venous system in 10 of 11 patients without the use of respiratory suspension or contrast material.


Assuntos
Imageamento por Ressonância Magnética , Flebografia/métodos , Adulto , Idoso , Inteligência Artificial , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema Porta/patologia , Portografia , Respiração , Estatística como Assunto , Trombose Venosa/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA