Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Regen Biomater ; 11: rbae001, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38343880

RESUMO

Biliary stenting is an important interventional method for the prevention and treatment of biliary tract diseases. However, complications, such as postoperative biliary infection and restenosis, frequently occur due to the extensive scope of the biliary system and the complex composition of bile. The combination of coating technology and biliary stents is expected to bring new approaches to the solution of these problems. The cutting-edge advance on functional coatings on biliary stents is reviewed from seven perspectives: anticorrosion, -bacterial, -tumor, stone-dissolving, X-ray visibility, antistent migration and functional composite coatings. The development trend is also discussed. Overall, the performance of the numerous functional coatings for various purposes is generally up to expectations, but the balance between the medications' effectiveness and their safety needs to be further adjusted. Many contemporary investigations have advanced to the level of animal experiments, offering crucial fundamental assurance for broader human studies. The combination of biliary stents and functional coatings is an innovative idea with great potential for future development.

2.
Adv Healthc Mater ; 13(12): e2303975, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38235953

RESUMO

Magnesium (Mg) alloys are widely used in bone fixation and bone repair as biodegradable bone-implant materials. However, their clinical application is limited due to their fast corrosion rate and poor mechanical stability. Here, the development of Mg-2Zn-0.5Ca-0.5Sr (MZCS) and Mg-2Zn-0.5Ca-0.5Zr (MZCZ) alloys with improved mechanical properties, corrosion resistance, cytocompatibility, osteogenesis performance, and antibacterial capability is reported. The hot-extruded (HE) MZCZ sample exhibits the highest ultimate tensile strength of 255.8 ± 2.4 MPa and the highest yield strength of 208.4 ± 2.8 MPa and an elongation of 15.7 ± 0.5%. The HE MZCS sample shows the highest corrosion resistance, with the lowest corrosion current density of 0.2 ± 0.1 µA cm-2 and the lowest corrosion rate of 4 ± 2 µm per year obtained from electrochemical testing, and a degradation rate of 368 µm per year and hydrogen evolution rate of 0.83 ± 0.03 mL cm-2 per day obtained from immersion testing. The MZCZ sample shows the highest cell viability in relation to MC3T3-E1 cells among all alloy extracts, indicating good cytocompatibility except at 25% concentration. Furthermore, the MZCZ alloy shows good antibacterial capability against Staphylococcus aureus.


Assuntos
Ligas , Antibacterianos , Magnésio , Teste de Materiais , Osteogênese , Antibacterianos/farmacologia , Antibacterianos/química , Ligas/química , Ligas/farmacologia , Corrosão , Animais , Osteogênese/efeitos dos fármacos , Camundongos , Magnésio/química , Magnésio/farmacologia , Staphylococcus aureus/efeitos dos fármacos , Implantes Absorvíveis , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Zinco/química , Zinco/farmacologia , Linhagem Celular , Estrôncio/química , Estrôncio/farmacologia , Zircônio/química , Zircônio/farmacologia
3.
Biomater Adv ; 153: 213529, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37348184

RESUMO

Bioelectricity plays an overriding role in directing cell migration, proliferation, differentiation etc. Tailoring the electro-extracellular environment through metallurgical manipulation could modulate the surrounding cell behaviors. In this study, different electric potential patterns, in terms of Volta potential distribution and gradient, were created on the metallic surface as an electric microenvironment, and their effects on adherent human mesenchymal stem cells were investigated. Periodically and randomly distributed Volta potential pattern, respectively, were generated on the surface through spark plasma sintering of two alternatively stacked dissimilar metals films and of a mixture of metallic powders. Actin cytoskeleton staining demonstrated that the Volta potential pattern strongly affected cell attachment and deformation. The cytoskeletons of cells were observed to elongate along the Volta potential gradient and across the border of adjacent regions with higher and lower potentials. Moreover, the steepest potential gradient resulting from the drastic compositional changes on the periodic borders gave rise to the strongest osteogenic tendency among all the samples. This study suggests that tailoring the Volta potential distribution and gradient of metallic biomaterials via metallurgical manipulation is a promising approach to activate surrounding cells, providing an extra degree of freedom for designing desirable bone-repairing metallic implants.


Assuntos
Células-Tronco Mesenquimais , Humanos , Células-Tronco Mesenquimais/metabolismo , Osteogênese , Osso e Ossos , Citoesqueleto/metabolismo , Citoesqueleto de Actina
4.
J Mater Chem B ; 9(48): 9806-9825, 2021 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-34842888

RESUMO

As a new generation of biomedical metallic materials, biodegradable metals have become a hot research topic in recent years because they can completely degrade in the human body, thus preventing secondary surgery, and reducing the pain and economic burden for patients. Clinical applications require biodegradable metals with adequate mechanical properties, corrosion resistance, and biocompatibility. Alloying is an important method to create biodegradable metals with required and comprehensive performances. Since nutrient elements already have important effects on various physiological functions of the human body, the alloying of nutrient elements with biodegradable metals has attracted much attention. The present review summarizes and discusses the effects of nutrient alloying elements on the mechanical properties, biodegradation behavior, and biocompatibility of biodegradable metals. Moreover, future research directions of biodegradable metals with nutrient alloying elements are suggested.


Assuntos
Ligas/metabolismo , Materiais Biocompatíveis/metabolismo , Nutrientes/metabolismo , Ligas/química , Materiais Biocompatíveis/química , Humanos , Teste de Materiais , Nutrientes/química
5.
Acta Biomater ; 130: 80-97, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34118448

RESUMO

Magnesium (Mg) is well-tolerated by the body, displaying exceedingly low toxicity, rapid excretion, and numerous bioactive effects, including improved bone formation and protection against oxidative stresses; further, Mg alloys can be degraded in vivo to allow complete removal of an implant without surgical intervention, avoiding revision surgery and thrombosis concerns seen with permanent implants. Rare earth elements (REEs) have been of particular interest in alloying Mg alloys for nearly a century due to their unique chemical and physical properties but have attracted increasing attention in recent decades. The REEs contribute greatly to the mechanical and biological properties of metal alloys, and so are common in Mg alloys in a wide variety of applications; in particular, they represent the dominant alloying additions in current, clinically applied Mg alloys. Notably, the use of these elements may assist in the development of advanced Mg alloys for use as biodegradable orthopedic implants and cardiovascular stents. To this end, current research progress in this area, highlighting the physiological impact of REEs in Mg alloys, is reviewed. Clinical work and preclinical data of REE-containing Mg alloys are analyzed. The biological roles of REEs in cellular responses in vivo require further research in the development of biofunctional Mg alloy medical devices. STATEMENT OF SIGNIFICANCE: The presented work is a review into the biological impact and current application of rare-earth elements (REEs) in biodegradable Mg-based biomaterials. Despite their efficacy in improving corrosion, mechanical, and manufacturability properties of Mg alloys, the physiological effects of REEs remain poorly understood. Therefore, the present work was undertaken to both provide guidance in the development of new biomedical alloys, and highlight areas of existing concerns and unclear knowledge. Key findings of this review include a summary of current clinical and preclinical work, and the identification of Sc as the most promising REE with regards to physiological impact. Y, Ce, Pr, Gd, Dy, Yb, Sm, and Eu should be considered carefully before their use as alloying elements, with other REEs intermediate or insufficiently studied.


Assuntos
Ligas , Metais Terras Raras , Ligas/farmacologia , Materiais Biocompatíveis/farmacologia , Corrosão , Magnésio/farmacologia
6.
Acta Biomater ; 106: 410-427, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32068137

RESUMO

Zinc (Zn) alloys are receiving increasing attention in the field of biodegradable implant materials due to their unique combination of suitable biodegradability and good biological functionalities. However, the currently existing industrial Zn alloys are not necessarily biocompatible, nor sufficiently mechanically strong and wear-resistant. In this study, a Zn-1Cu-0.1Ti alloy is developed with enhanced mechanical strength, corrosion wear property, biocompatibility, and antibacterial ability for biodegradable implant material applications. HR and HR + CR were performed on the as-cast alloy and its microstructure, mechanical properties, frictional and wear behaviors, corrosion resistance, in vitro cytocompatibility, and antibacterial ability were systematically assessed. The microstructures of the Zn-1Cu-0.1Ti alloy after different deformation conditions included a η-Zn phase, a ε-CuZn5 phase, and an intermetallic phase of TiZn16. The HR+CR sample of Zn-1Cu-0.1Ti exhibited a yield strength of 204.2 MPa, an ultimate tensile strength of 249.9 MPa, and an elongation of 75.2%; significantly higher than those of the HR alloy and the AC alloy. The degradation rate in Hanks' solution was 0.029 mm/y for the AC alloy, 0.032 mm/y for the HR+CR alloy, and 0.034 mm/y for the HR alloy. The HR Zn-1Cu-0.1Ti alloy showed the best wear resistance, followed by the AC alloy and the alloy after HR + CR. The extract of the AC Zn-1Cu-0.1Ti alloy showed over 80% cell viability with MC3T3-E1 pre-osteoblast and MG-63 osteosarcoma cells at a concentration of ≤ 25%. The as-cast Zn-1Cu-0.1Ti alloy showed good blood compatibility and antibacterial ability. STATEMENT OF SIGNIFICANCE: This work repots a Zn-1Cu-0.1Ti alloy with enhanced mechanical strength, corrosion wear property, biocompatibility, and antibacterial ability for biodegradable implant applications. Our findings showed that Zn-1Cu-0.1Ti after hot-rolling plus cold-rolling exhibited a yield strength of 204.2 MPa, an ultimate tensile strength of 249.9 MPa, an elongation of 75.2%, and a degradation rate of 0.032 mm/y in Hanks' Solution. The hot-rolled Zn-1Cu-0.1Ti showed the best wear resistance. The extract of the as-cast alloy at a concentration of ≤ 25% showed over 80% cell viability with MC3T3-E1 and MG-63 cells. The Zn-1Cu-0.1Ti alloy showed good hemocompatibility and antibacterial ability.


Assuntos
Implantes Absorvíveis , Ligas/química , Ligas/farmacologia , Antibacterianos/química , Antibacterianos/farmacologia , Ligas/toxicidade , Animais , Antibacterianos/toxicidade , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Cobre/química , Hemólise/efeitos dos fármacos , Humanos , Teste de Materiais , Camundongos , Testes de Sensibilidade Microbiana , Staphylococcus aureus/efeitos dos fármacos , Resistência à Tração , Titânio/química , Zinco/química
7.
ACS Appl Mater Interfaces ; 12(5): 6776-6787, 2020 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-31917541

RESUMO

Some important factors in the design of biomaterials are surface characteristics such as surface chemistry and topography, which significantly influence the relationship between the biomaterial and host cells. Therefore, nanotubular oxide layers have received substantial attention for biomedical applications due to their potential benefits in the improvement of the biocompatibility of the substrate. In this study, a nanotubular layer of titania-niobium pentoxide-zirconia (TiO2-Nb2O5-ZrO2) was developed via anodization on a ß-type Ti35Zr28Nb alloy surface with enhanced biocompatibility. Scanning electron microscopy (SEM) and surface profilometry analysis of the anodized nanotubes indicated that the inner diameter (Di) and wall thicknesses (Wt) increased with an increase in the water content of electrolyte and the applied voltage during anodization, while the nanotube length (Ln) increased with increasing the anodization time. TiO2-Nb2O5-ZrO2 nanotubes with different Di, Wt, and Ln showed different surface roughnesses (Ra) and surface energies (γ), which affected the biocompatibility of the base alloy. MTS assay results showed that the TiO2-Nb2O5-ZrO2 nanotubes with the largest inner diameter (Di) of 75.9 nm exhibited the highest cell viability of 108.55% due to the high γ of the surface, which led to high adsorption of proteins on the top surface of the nanotubes. The second highest cell viability was observed on the nanotubular surface with Di of 33.3 nm, which is believed to result from its high γ as well as the optimum spacing between nanotubes. Ra did not appear to be clearly linked to cellular response; however, there may exist a threshold value of surface energy of ∼70 mJ/m2, below which the cell response is less sensitive and above which the cell viability increases with increasing γ. This indicates that the TiO2-Nb2O5-ZrO2 nanotubes provided a suitable environment for enhanced attachment and growth of osteoblast-like cells as compared to the bare Ti35Zr28Nb alloy surface.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Nanotubos/química , Ligas/farmacologia , Materiais Biocompatíveis/farmacologia , Adesão Celular/efeitos dos fármacos , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Humanos , Interações Hidrofóbicas e Hidrofílicas , Nióbio/química , Óxidos/química , Propriedades de Superfície , Titânio/química , Zircônio/química
8.
Acta Biomater ; 102: 481-492, 2020 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-31740321

RESUMO

Zinc (Zn) alloys have attracted much attention for biomedical applications due to their biodegradability, biocompatibility, and biological functionalities. Zn alloy foams have high potential to be used as regenerative medical implants by virtue of their porous structure, which allows new bone tissue ingrowth, their low elastic modulus approximating that of natural bone, and their biodegradation, which eliminates the need for follow-up surgery to remove the implants after bone tissue healing. In this context, a biodegradable Zn-Cu foam was fabricated by electrochemical deposition on a foamed Cu template and given a subsequent diffusion heat treatment. The microstructure, mechanical properties, degradation behavior, toxicity, hemolysis percentages, and antibacterial effects of the Zn-Cu foams were assessed for biomedical applications. The Zn-Cu foams exhibited a yield strength of ~12.1 MPa, a plateau strength of 16.8 MPa, and a strain over 50% under compression tests. The corrosion rate of the Zn-Cu foams measured by electrochemical polarization testing was 0.18 mm/y. The Zn-Cu foams showed good blood compatibility with a hemolysis percentage of less than 5%. Cytotoxicity assessment indicated that a 100% concentration of the Zn-Cu foam extract showed clear cytotoxicity against MC3T3-E1 osteoblast cells, but a 12.5% concentration of the extract showed > 90% cell viability. Moreover, the Zn-Cu foams showed good antibacterial effects. STATEMENT OF SIGNIFICANCE: This work reportsa biodegradable Zn-Cu foam with high mechanical strength and ductility, suitable degradation rate, good antibacterial capacity, and good hemolysis property and biocompatibility. The Zn-Cu foam exhibited a yield strength of ~12.1 MPa, a plateau strength of 16.8 MPa, and a strain over 50% under compression tests. The corrosion rate of the Zn-Cu foam measured by electrochemical polarization testing was 0.18 mm/y in Hanks' Solutions. The Zn-Cu foam showed good blood compatibility with a hemolysis percentage of less than 5%. Cytotoxicity assessment indicated that a 12.5% concentration of the foam extract showed > 90% cell viability. Moreover, the Zn-Cu foam showed good antibacterial effects against S. aureus.


Assuntos
Antibacterianos/farmacologia , Materiais Biocompatíveis/farmacologia , Cobre/farmacologia , Zinco/farmacologia , Implantes Absorvíveis , Animais , Antibacterianos/química , Antibacterianos/toxicidade , Materiais Biocompatíveis/química , Materiais Biocompatíveis/toxicidade , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Cobre/química , Cobre/toxicidade , Módulo de Elasticidade , Hemólise/efeitos dos fármacos , Humanos , Teste de Materiais , Camundongos , Testes de Sensibilidade Microbiana , Staphylococcus aureus/efeitos dos fármacos , Zinco/química , Zinco/toxicidade
9.
Acta Biomater ; 102: 493-507, 2020 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-31811958

RESUMO

Magnesium (Mg) and its alloys are considered promising biodegradable implant materials because of their strength and natural degradation in the human body. However, the high corrosion rate of pure Mg in the physiological environment leads to rapid degradation before adequate bone healing. This mismatch between bone healing and the degradation of Mg implants supports the development of new Mg alloys with the addition of other suitable alloying elements in order to achieve simultaneously high corrosion resistance and desirable mechanical properties. This study systematically investigates the microstructure, mechanical properties, corrosion behavior, and biocompatibility of Mg-based alloys with the addition of different concentrations of scandium (Sc), i.e., Mg-0.6Zr-0.5Sr-xSc (x = 0.5, 1, 2, 3 wt.%). Results indicated that high concentration of Sc in strontium (Sr)-containing Mg alloys can alter their microstructures by suppressing the intermetallic phases along the grain boundaries and improve the corrosion resistance by forming chemically stable Sc oxide layers on the surfaces of the Mg alloys. Cytotoxicity assessment revealed that the Sc containing Mg alloys did not significantly alter the viability of human osteoblast-like SaOS2 cells. This study highlights the advantages of using Sc as an alloying element to simultaneously tune Mg alloys with higher strength and slower degradation. STATEMENT OF SIGNIFICANCE: Rare earth elements such as scandium (Sc) with both a high solid-solubility and strong affinity towards oxygen can improve the mechanical and corrosion properties of magnesium (Mg) alloys. However, the feasibility of Sc-containing Mg alloys as biodegradable implant materials is scarcely reported. This study investigates the effects of different Sc concentrations on the mechanical, corrosion, and biocompatibility properties of Mg-Zr-Sr-Sc alloys. Our findings indicated that the addition of Sc significantly improves the mechanical and corrosion properties of Mg-Zr-Sr alloys. Moreover, in vitro cytotoxicity assessment of the Mg-Zr-Sr-Sc alloys did not show any adverse effects on the viability of osteoblast-like cells.


Assuntos
Implantes Absorvíveis , Ligas/química , Materiais Biocompatíveis/química , Ligas/toxicidade , Materiais Biocompatíveis/toxicidade , Linhagem Celular Tumoral , Corrosão , Humanos , Teste de Materiais , Resistência à Tração
10.
Acta Biomater ; 97: 587-596, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31398474

RESUMO

The present study investigates the nanoindentation behavior, wear resistance and in vitro biocompatibility of SLM manufactured CP-Ti and EBM manufactured Ti64 gyroid scaffolds and the results were compared to those of casting CP-Ti. Both the SLM- and EBM manufactured scaffolds exhibited anisotropic properties with higher reduced modulus (up to 10%) and nanohardness (up to 30%) in the transverse direction than those in building direction. The wear resistance of scaffolds in transverse direction was higher than those of in building direction by up to ∼25% and ∼82% for SLM manufactured CP-Ti and EBM manufactured Ti64 scaffolds, respectively. The SLM manufactured CP-Ti scaffolds displayed significant enhancement in wear resistance over cast dense CP-Ti with 75% lower mean worn height during a nanowear test. The coefficient of friction was varied between 0.11 and 0.24 and exhibited a steady mean value of 0.15-0.18 for CP-Ti and Ti64 scaffolds, respectively. During in vitro cell culture study, CP-Ti scaffolds showed higher cell viability and cell adhesion density in comparison to Ti64 scaffolds for all unit cell sizes. Moreover, cell adhesion density of scaffolds with smaller unit cell sizes (G2) are lower than those of larger unit cells (G3). SEM observations confirmed that both the inner space and surfaces of gyroid scaffolds provided a suitable environment for cell migration, attachment and proliferation after cell culture for 7 d. STATEMENT OF SIGNIFICANCE: It is essential to evaluate the properties of EBM/SLM manufactured scaffolds and to determine whether they can meet the tough performance requirements of the biomedical industry. In this study, nanoindentation and nanowear properties of SLM manufactured CP-Ti and EBM manufactured Ti64 gyroid scaffolds with different unit cell sizes and sample orientations were evaluated and compared to cast dense CP-Ti samples. Moreover, the in vitro biocompatibility of the scaffolds was assessed and compared to each other. To our best of knowledge, this type of study on EBM/SLM manufactured CP-Ti and Ti64 scaffolds have not been reported, to date.


Assuntos
Teste de Materiais , Alicerces Teciduais/química , Titânio , Linhagem Celular Tumoral , Humanos , Propriedades de Superfície , Titânio/química , Titânio/farmacologia
11.
Bioact Mater ; 4(1): 22-36, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30533554

RESUMO

The application of various materials in biomedical procedures has recently experienced rapid growth. One area that is currently receiving significant attention from the scientific community is the treatment of a number of different types of bone-related diseases and disorders by using biodegradable polymer-ceramic composites. Biomaterials, the most common materials used to repair or replace damaged parts of the human body, can be categorized into three major groups: metals, ceramics, and polymers. Composites can be manufactured by combining two or more materials to achieve enhanced biocompatibility and biomechanical properties for specific applications. Biomaterials must display suitable properties for their applications, about strength, durability, and biological influence. Metals and their alloys such as titanium, stainless steel, and cobalt-based alloys have been widely investigated for implant-device applications because of their excellent mechanical properties. However, these materials may also manifest biological issues such as toxicity, poor tissue adhesion and stress shielding effect due to their high elastic modulus. To mitigate these issues, hydroxyapatite (HA) coatings have been used on metals because their chemical composition is similar to that of bone and teeth. Recently, a wide range of synthetic polymers such as poly (l-lactic acid) and poly (l-lactide-co-glycolide) have been studied for different biomedical applications, owing to their promising biocompatibility and biodegradability. This article gives an overview of synthetic polymer-ceramic composites with a particular emphasis on calcium phosphate group and their potential applications in tissue engineering. It is hoped that synthetic polymer-ceramic composites such as PLLA/HA and PCL/HA will provide advantages such as eliminating the stress shielding effect and the consequent need for revision surgery.

12.
ACS Biomater Sci Eng ; 5(4): 1686-1702, 2019 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-33405546

RESUMO

In this work, the role that manganese plays in determining the structure and performance of sintered biodegradable porous Fe-Mn alloys is described. Powder metallurgy processing was employed to produce a series of biodegradable porous Fe-xMn (x = 20, 30, and 35 wt %) alloys suitable for bone scaffold applications. Increasing manganese content increased the porosity volume in the sintered alloys and influenced the ensuing properties of the metal. The Fe-35Mn alloy possessed optimum properties for orthopedic application. X-ray diffraction analysis and magnetic characterization confirmed the predominance of the antiferromagnetic austenitic phase and ensured the magnetic resonance imaging (MRI) compatibility of this alloy. The porous Fe-35Mn alloy possessed mechanical properties (tensile strength of 144 MPa, elastic modulus of 53.3 GPa) comparable to human cortical bone. The alloy exhibited high degradation rates (0.306 mm year-1) in simulated physiological fluid, likely due to its considerable Mn content and the high surface area inherent to its porous structures, while cytotoxicity and morphometry tests using mammalian preosteoblast cells (MC3T3-E1) indicated good cell viability in the Fe-35Mn alloy.

13.
Acta Biomater ; 48: 461-467, 2017 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-27746362

RESUMO

In this paper, we present further work on the influence of minor additions of Ru to the Ti-20Nb alloy system, with a primary focus on mechanical properties of the as-cast material, along with microstructural response to elevated temperatures. Findings include high as-cast strengths and admissible strain values, up to 920MPa and 1.5% respectively, along with moduli down to approximately 65GPa in the as-cast state. Together with a significant increase in cell proliferation under MTS assay relative to controls, this indicates the chosen alloy system has significant promise for application in porous orthopaedic biomaterials, in particular those alloys with 0.5-1.0% Ru are deemed most suitable. Given their promise, preliminary investigation of the alloy system's response to thermal treatment was also undertaken. STATEMENT OF SIGNIFICANCE: The presented research, an investigation into the mechanical properties and response to thermal treatments of Ru-containing Ti-20Nb-base alloys, holds significance in the field of metallic biomaterials due to the heretofore limited investigation into the impact of Ru on the properties of biomedical, ß-phase, Ti-based alloys. Given Ru's known beneficial impact on corrosion resistance, experimental confirmation of the impact of addition on mechanical properties was needed; that suitable mechanical properties, including yield strengths up to ∼930MPa along with elastic admissible strains approaching 1.5%, were achieved is both promising in and of itself, and of significant note for further research into the field. Preliminary thermal and cell-proliferation studies are additionally provided to inform further studies.


Assuntos
Ligas/química , Ligas/farmacologia , Fenômenos Mecânicos , Nióbio/farmacologia , Rutênio/farmacologia , Temperatura , Titânio/farmacologia , Varredura Diferencial de Calorimetria , Linhagem Celular Tumoral , Força Compressiva , Humanos , Nióbio/química , Rutênio/química , Resistência à Tração , Titânio/química , Difração de Raios X
14.
J Biomed Mater Res A ; 105(1): 148-158, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27601355

RESUMO

Elemental metals have been widely used to alloy metallic orthopedic implants. However, there is still insufficient research data elucidating the cell responses of osteoblastic cells to alloying elemental metals, which impedes the development of new metallic implant materials. In this study, the cellular responses of osteoblast-like cells (SaOS2) to 17 pure alloying elemental metals, that is, titanium (Ti), zirconium (Zr), hafnium (Hf), vanadium (V), niobium (Nb), tantalum (Ta), chromium (Cr), molybdenum (Mo), manganese (Mn), iron (Fe), ruthenium (Ru), cobalt (Co), nickel (Ni), copper (Cu), zinc (Zn), silicon (Si), and tin (Sn) were comparatively investigated in vitro. Cellular responses including intracellular total protein synthesis and collagen content, cell adhesion, cell proliferation, and alkaline phosphatase (ALP) activity on these elemental metals were systematically assessed and compared. It was found that these elemental metals could be categorized into three groups based on the cellular functions on them. Group 1, including Ti, Zr, Hf, Nb, Ta, Cr, Ru, and Si, showed excellent cell proliferation and varied ALP activity for SaOS2 cells. Cells exposed to Group 2, including Mo and Sn, although initially attached and grew, did not proliferate over time. In contrast, Group 3, including V, Mn, Fe, Co, Ni, Cu, and Zn, showed severe cytotoxicity toward SaOS2 cells. It is vital to consider the cell responses to the elemental metals when designing a new metallic implant material and the findings of this study provide insights into the biological performance of the elemental metals. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 148-158, 2017.


Assuntos
Ligas , Antígenos de Diferenciação/biossíntese , Proliferação de Células/efeitos dos fármacos , Teste de Materiais , Osteoblastos/metabolismo , Biossíntese de Proteínas/efeitos dos fármacos , Ligas/química , Ligas/farmacologia , Adesão Celular/efeitos dos fármacos , Linhagem Celular , Humanos , Osteoblastos/citologia
15.
Sci Rep ; 6: 27207, 2016 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-27272562

RESUMO

Removal of oils and organic solvents from water is an important global challenge for energy conservation and environmental protection. Advanced sorbent materials with excellent sorption capacity need to be developed. Here we report on a superhydrophobic and superoleophilic MoS2 nanosheet sponge (SMS) for highly efficient separation and absorption of oils or organic solvents from water. This novel sponge exhibits excellent absorption performance through a combination of superhydrophobicity, high porosity, robust stability in harsh conditions (including flame retardance and inertness to corrosive and different temperature environments) and excellent mechanical properties. The dip-coating strategy proposed for the fabrication of the SMS, which does not require a complicated process or sophisticated equipment, is very straightforward and easy to scale up. This finding shows promise for water remediation and oil recovery.

16.
Acta Biomater ; 20: 176-187, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25818950

RESUMO

A new series of beta Ti-Nb-Zr (TNZ) alloys with considerable plastic deformation ability during compression test, high elastic admissible strain, and excellent cytocompatibility have been developed for removable bone tissue implant applications. TNZ alloys with nominal compositions of Ti-34Nb-25Zr, Ti-30Nb-32Zr, Ti-28Nb-35.4Zr and Ti-24.8Nb-40.7Zr (wt.% hereafter) were fabricated using the cold-crucible levitation technique, and the effects of alloying element content on their microstructures, mechanical properties (tensile strength, yield strength, compressive yield strength, Young's modulus, elastic energy, toughness, and micro-hardness), and cytocompatibilities were investigated and compared. Microstructural examinations revealed that the TNZ alloys consisted of ß phase. The alloy samples displayed excellent ductility with no cracking, or fracturing during compression tests. Their tensile strength, Young's modulus, elongation at rupture, and elastic admissible strain were measured in the ranges of 704-839 MPa, 62-65 GPa, 9.9-14.8% and 1.08-1.31%, respectively. The tensile strength, Young's modulus and elongation at rupture of the Ti-34Nb-25Zr alloy were measured as 839 ± 31.8 MPa, 62 ± 3.6 GPa, and 14.8 ± 1.6%, respectively; this alloy exhibited the elastic admissible strain of approximately 1.31%. Cytocompatibility tests indicated that the cell viability ratios (CVR) of the alloys are greater than those of the control group; thus the TNZ alloys possess excellent cytocompatibility.


Assuntos
Ligas/farmacologia , Módulo de Elasticidade/efeitos dos fármacos , Teste de Materiais/métodos , Equipamentos Ortopédicos , Adesão Celular/efeitos dos fármacos , Contagem de Células , Morte Celular/efeitos dos fármacos , Linhagem Celular Tumoral , Forma Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Força Compressiva/efeitos dos fármacos , Dureza , Humanos , Resistência à Tração/efeitos dos fármacos , Difração de Raios X
17.
Acta Biomater ; 8(5): 1661-9, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22326786

RESUMO

Shape memory alloys (SMAs) are materials that exhibit a distinct thermomechanical coupling, one that gives rise to a wide variety of applications across a broad range of fields. One of the most successful roles is in the construction of novel medical implants. Unfortunately, concerns have been raised about the biocompatibility of the most popular SMA, nitinol (NiTi), due to the known toxic, allergenic and carcinogenic properties of nickel. Given the unique capabilities of SMAs, it is apparent that there is a need for a new class of alloys - alloys that exhibit the full range of shape memory abilities yet are also free of any undesirable side effects. This article reviews the literature surrounding SMAs and identifies the metals Ti, Au, Sn, Ta, Nb, Ru and Zr as candidates for the production of thoroughly biocompatible SMAs. Hf and Re are also promising, though more research is necessary before a definitive statement can be made. Further, the Ti-(Ta,Nb)-(Zr,Hf) alloy system is particularly suited for orthopaedic implants due to a reduced Young's modulus. However, concerns over this system's shape memory properties exist, and should be taken into consideration. Alternate alloy systems that demonstrate higher bulk moduli may still be considered, however, if they are formed into a porous structure. Due to the nature of the alloying components, blended elemental powder metallurgy is recommended for the manufacture of these alloys, particularly due to the ease with which it may be adapted to the formation of porous alloys.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Próteses e Implantes/tendências , Titânio/química , Módulo de Elasticidade , Desenho de Prótese
18.
Tissue Eng Part A ; 16(1): 309-16, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19705960

RESUMO

Porous titanium (Ti) and Ti alloys are important scaffold materials for bone tissue engineering. In the present study, a new type of porous Ti alloy scaffold with biocompatible alloying elements, that is, niobium (Nb) and zirconium (Zr), was prepared by a space-holder sintering method. This porous TiNbZr scaffold with a porosity of 69% exhibits a mechanical strength of 67 MPa and an elastic modulus of 3.9 GPa, resembling the mechanical properties of cortical bone. To improve the osteoconductivity, a calcium phosphate (Ca/P) coating was applied to the surface of the scaffold using a biomimetic method. The biocompatibility of the porous TiNbZr alloy scaffold before and after the biomimetic modification was assessed using the SaOS2 osteoblast-like cells. Cell culture results indicated that the porous TiNbZr scaffold is more favorable for cell adhesion and proliferation than its solid counterpart. By applying a Ca/P coating, the cell proliferation rate on the Ca/P-coated scaffold was significantly improved. The results suggest that high-strength porous TiNbZr scaffolds with an appropriate osteoconductive coating could be potentially used for bone tissue engineering application.


Assuntos
Ligas , Materiais Biomiméticos , Substitutos Ósseos , Nióbio , Engenharia Tecidual/métodos , Zircônio , Linhagem Celular Tumoral , Humanos , Porosidade
19.
Clin Implant Dent Relat Res ; 12(1): 72-9, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19076179

RESUMO

BACKGROUND: Titanium (Ti) is widely proven to enhance bone contact and growth on its surface. It is expected that bone defects could benefit from Ti to promote healing and to increase strength of the implanted area. PURPOSE: The present study aimed at comparing the potential of porous Ti sponge rods with synthetic hydroxyapatite (HA) for the healing of bone defects in a canine model. MATERIAL AND METHODS: Six mongrel dogs were submitted to three trephined osteotomies of 6.0 x 4.0 mm in one humerus and after 2 months another three osteotomies were performed in the contralateral humerus. A total of 36 defects were randomly filled either with Ti foam, particulate HA, or coagulum (control). The six animals were killed 4 months after the first surgery for histological and histometrical analysis. RESULTS: The Ti-foam surface was frequently found in intimate contact with new bone especially at the defect walls. Control sites showed higher amounts of newly formed bone at 2 months - Ti (p = 0.000) and HA (p = 0.009) - and 4 months when compared with Ti (p = 0.001). Differently from HA, the Ti foam was densely distributed across the defect area which rendered less space for bone growth in the latter's sites. The use of Ti foams or HA resulted in similar amounts of bone formation in both time intervals. Nevertheless, the presence of a Ti-foam rod preserved defect's marginal bone height as compared with control groups. Also, the Ti-foam group showed a more mature bone pattern at 4 months than HA sites. CONCLUSION: The Ti foam exhibited good biocompatibility, and its application resulted in improved maintenance of bone height compared with control sites. The Ti foam in a rod design exhibited bone ingrowth properties suitable for further exploration in other experimental situations.


Assuntos
Materiais Biocompatíveis/química , Substitutos Ósseos/uso terapêutico , Durapatita/uso terapêutico , Úmero/cirurgia , Osteogênese/fisiologia , Osteotomia/métodos , Titânio/química , Animais , Doenças Ósseas/patologia , Doenças Ósseas/cirurgia , Medula Óssea/patologia , Corantes , Modelos Animais de Doenças , Cães , Úmero/patologia , Masculino , Pironina , Distribuição Aleatória , Fatores de Tempo , Alicerces Teciduais , Cloreto de Tolônio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA