Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38738862

RESUMO

PURPOSE: The purpose of this study was to examine the effects of intraoperative technology use on the rate of using polyethylene liners 15 mm or greater during primary total knee arthroplasty (TKA). METHODS: There were 103,295 implants from 16,386 primary unilateral TKAs performed on 14,253 patients at a single institution between 1 January 2018, and 30 June 2022, included in the current study. Robotic assistance and navigation guidance were used in 1274 (8%) and 8345 (51%) procedures, respectively. The remaining 6767 TKAs (41%) were performed manually. Polyethylene liners were manually identified and further subcategorised by implant thickness. Patients who underwent robotic-assisted TKA were younger (p < 0.001) and more likely to be male (p < 0.001) compared to patients who underwent navigation-guided or manual TKAs. RESULTS: Average polyethylene liner thickness was similar between groups (10.5 ± 1.5 mm for robotic-assisted TKAs, 10.9 ± 1.8 mm for navigation-guided TKAs and 10.8 ± 1.8 mm for manual TKAs). The proportions of polyethylene liners 15 mm or greater used were 4.9%, 3.8% and 1.9% for navigation-guided, manual and robotic-assisted procedures, respectively (p < 0.001). Multivariate regression analyses demonstrated that navigation-guided (odds ratio [OR]: 2.6, 95% confidence Interval [CI]: [1.75-4.07], p < 0.001) and manual (OR: 2.0, 95% CI: [1.34-3.20], p = 0.001) procedures were associated with an increased use of polyethylene liners 15 mm or greater. CONCLUSION: Robotic-assisted TKA was associated with a lower proportion of polyethylene liners 15 mm or greater used compared to navigation-guided and manual TKA. These findings suggest that robotic assistance can reduce human error via a more precise cutting system, limit over-resection of the tibia and flexion-extension gap mismatch and ultimately allow for more appropriately sized implants. LEVEL OF EVIDENCE: Level III, retrospective cohort study.

2.
J Arthroplasty ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38642850

RESUMO

BACKGROUND: Identification of femoral component debonding in the work-up of painful total knee arthroplasty (TKA) often poses a diagnostic challenge. The purpose of this study was to compare the sensitivity and specificity of radiographs, computed tomography (CT), and magnetic resonance imaging (MRI) for identifying femoral component loosening with debonding at the time of revision of a primary TKA with a recalled polyethylene insert. METHODS: Using an institutional database, we identified all cases of revision TKA performed for this specific implant recall following a primary TKA between 2014 and 2022. Patients who had a preoperative radiograph, CT, and MRI were included (n = 77). Sensitivity, specificity, and positive and negative likelihood ratio (LR) for predicting loosening were compared among the imaging modalities, using the intraoperative evidence of implant loosening as the gold standard. RESULTS: At the time of revision surgery, the femoral component was noted to have aseptic loosening with debonding in 46 of the 77 (60%) of the TKAs. There were no significant differences in demographics in the cohort with femoral debonding compared to those with well-fixed implants. The CT demonstrated a sensitivity of 28% and a specificity of 97%, while the MRI demonstrated a sensitivity of 37% and a specificity of 94% for detecting femoral loosening due to debonding. Both CT and MRI demonstrated poor negative LRs for femoral loosening (LR 0.7). CONCLUSIONS: In this series of revision TKAs for a specific recalled component, neither CT nor MRI accurately diagnosed femoral component debonding. For patients who have this implant, it is imperative to interrogate the implant-cement interface intraoperatively and prepare for full revision surgery as well as marked bone loss secondary to osteolysis.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38662001

RESUMO

INTRODUCTION: Options for soft tissue coverage in revision total knee arthroplasty (rTKA) range from primary wound closure to complex muscle flap reconstructions. The purpose of this study was to investigate the institutional experience of wound coverage options for complex soft tissue defects in rTKA. MATERIALS AND METHODS: 77 patients undergoing rTKA with complex wound closure by a single plastic surgeon were retrospectively reviewed. The average follow-up was 30.1 months. In 18 (23.4%) patients, an intraoperative decision for primary closure was made. Fifty-nine patients (76.6%) received either a local fasciocutaneous (N = 18), a medial gastrocnemius (N = 37), a free latissimus dorsi (N = 3) or a lateral gastrocnemius flap (N = 1). Revision-free survival and complication rates were assessed and risk factors were analyzed with Cox-regression analysis. RESULTS: Medial gastrocnemius flaps had significant lower cumulative revision-free survival rates than local fasciocutaneous flaps (P = 0.021) and primary closures (P < 0.001) (42.5% vs. 71.5% vs. 100%,respectively). Comparing the most common complex closure procedures medial gastrocnemius flaps had the highest rate of prolonged wound healing (29.7%) and infection/reinfection (40.5%). Infection-associated flap procedures had significant lower cumulative revision-free survival rates (30.5%) than non-infection associated flap procedures (62.8%,P = 0.047). A history of more than two prior surgeries (HR = 6.11,P < 0.001) and an age ≥ 65 years (HR = 0.30,P = 0.018) significantly increased the risk of revision. CONCLUSIONS: The results of this study indicate that primary closure -if possible- should be preferred to early proactive muscle flap coverage. Even in the hands of an experienced plastic surgeon muscle flaps have high revision and complication rates. The study highlights the need to clarify flap indications and to investigate alternative approaches.

4.
Hip Int ; 34(1): 15-20, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36891584

RESUMO

INTRODUCTION: The relationship between implant type, dual mobility (DM) or fixed bearing (FB), and postoperative groin pain remains unexplored. We examined the incidence of groin pain in DM implants and compare this to a cohort of FB THA patients. METHODS: From 2006 to 2018, a single surgeon performed 875 DM THA and 856 FB THA procedures with 2.8-year and 3.1-year follow-up, respectively. Each patient received a questionnaire postoperatively and was asked if they had any groin pain (yes/no). Secondary measurements were implant characteristics such as head size, head offset, cup size, and cup-to-head ratio. Additional PROMs that were collected included: Veterans RAND 12 (VR-12), University of California Los Angeles (UCLA) activity score, Pain visual analogue scale (Pain VAS), and range of motion (ROM). RESULTS: The incidence of groin pain was 2.3% in the DM THA cohort and 6.3% in the FB THA group (p < 0.001). Also, low head offset (⩽0 mm) had a significant odds ratio (1.61) for groin pain in both cohorts. There was no significant difference in terms of revision rate between the cohorts (2.5% vs. 3.3%, p = 0.39) at the latest follow up. CONCLUSIONS: This study demonstrated a lower incidence of groin pain (2.3%) in patients with a DM bearing compared to a FB (6.3%) and a greater risk of groin pain with low head offset (<0 mm). As such, surgeons should try to recreate offset of the hip compared to the contralateral side to avoid groin pain.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Virilha/cirurgia , Reoperação/efeitos adversos , Desenho de Prótese , Dor Pós-Operatória/epidemiologia , Dor Pós-Operatória/etiologia , Falha de Prótese , Luxação do Quadril/cirurgia , Estudos Retrospectivos
5.
Arch Orthop Trauma Surg ; 143(11): 6927-6933, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37395854

RESUMO

INTRODUCTION: Due to the increasing number of total hip arthroplasties (THA), the number and complexity of revision procedures are also on the rise. For complex cases such as periprosthetic joint infections with soft tissue compromise or for abductor muscle deficiencies, one of the treatment options is a gluteus maximus flap (GMF) that covers dead space and can help restore the failed abductor mechanism. The purpose of this study is to investigate the outcomes of a single-plastic surgeon's series of GMF procedures. MATERIALS AND METHODS: This retrospective review reports on 57 patients (mean follow-up 39.2 months) undergoing GMF transfers for abductor insufficiency on native hip (N = 16), for abductor insufficiency in aseptic revision THA (rTHA) (N = 16), for soft tissue defects in aseptic rTHA (N = 8) and for soft tissue defects in septic rTHA (N = 17) by a single plastic surgeon over a 10-year period. Revision-free survival and complication rates were assessed and risk factors were analyzed with Cox-regression analysis. RESULTS: The reoperation-free survival rate of GMF for abductor insufficiency in native hips was 100%. GMF procedures for soft tissue defects in septic rTHA had the lowest cumulative revision-free survival (34.3%) and highest reinfection rates (53.9%). More than three prior surgeries (HR = 2.9, p = 0.020), presence of infection (HR = 3.2, p = 0.010) and resistant organisms (HR = 3.1, p = 0.022) significantly increased the risk of revision. CONCLUSIONS: GMF is a viable option for addressing abductor insufficiency in native hip joints. However, high revision and complication rates are reported for GMF in septic rTHA. This study highlights the need to clarify the circumstances for which the flap reconstruction will be indicated.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Cirurgiões , Humanos , Fator de Maturação da Glia , Retalhos Cirúrgicos/cirurgia , Articulação do Quadril/cirurgia , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Estudos Retrospectivos
6.
J Arthroplasty ; 38(6S): S290-S296.e1, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36907386

RESUMO

BACKGROUND: A specific total knee arthroplasty (TKA) implant system was recently recalled for high incidence of early polymeric wear and osteolysis. We analyzed the early outcomes of aseptic revision with these implants. METHODS: We identified 202 aseptic revision TKAs of this implant system performed at a single institution between 2010 and 2020. Revision indications included aseptic loosening (n = 120), instability (n = 55), and polymeric wear/osteolysis (n = 27). Components were revised in 145 cases (72%) and isolated polyethylene insert exchange occurred in 57 cases (28%). Kaplan-Meier and Cox proportional hazards analyses were used to determine survivorship free from all-cause rerevision and rerevision risk factors. RESULTS: At 2 and 5 years, survivorship free from all-cause rerevision was 89 and 76% in the polyethylene exchange cohort versus 92 and 84% in the component revision cohort (P = .5). At 2 and 5 years, survivorship in revision with components from the same manufacturer was 89 and 80% compared to 95 and 86% in revision with components from a different manufacturer (P = .2). Among re-revisions (n = 30), cones (37%), sleeves (7%), hinge/distal femoral replacement implants were frequently used (13%). Men had increased risk for rerevision (hazard ratio = 2.3, P = .04). CONCLUSION: In this series of aseptic revision TKAs performed on a now-recalled implant system, survivorship free from rerevision was lower than expected when components from the same manufacturer were utilized, but comparable to contemporary reports when both the components were revised with an alternative implant system. Metaphyseal fixation with cones and sleeves as well as highly constrained implants was frequently utilized at time of rerevision TKA. LEVEL OF EVIDENCE: Level IV.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteólise , Masculino , Humanos , Artroplastia do Joelho/efeitos adversos , Osteólise/epidemiologia , Osteólise/etiologia , Osteólise/cirurgia , Falha de Prótese , Desenho de Prótese , Prótese do Joelho/efeitos adversos , Reoperação , Polietileno , Estudos Retrospectivos , Resultado do Tratamento , Articulação do Joelho/cirurgia
7.
J Arthroplasty ; 38(6S): S363-S367, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36813214

RESUMO

BACKGROUND: Fractures of the polyethylene post are a rare but known complication after posterior-stabilized (PS) total knee arthroplasty (TKA). We evaluated the polyethylene and patient characteristics for 33 primary PS polyethylene components that were revised with fractured posts. METHODS: We identified 33 PS inserts revised between 2015 and 2022. Patient characteristics collected included age at index TKA, sex, body mass index, length of implantation (LOI), and patient-reported details on events surrounding the post fracture. Implant characteristics recorded were manufacturer, cross-linking properties (highly cross-linked polyethylene [XLPE] versus ultra-high molecular weight polyethylene [UHMWPE]), wear characteristics based on subjective scoring of the articular surfaces and scanning electron microscopy (SEM) of fracture surfaces. Mean age at index surgery was 55 years (range, 35 to 69), mean body mass index was 29.5 (range, 18.5 to 37.2), and mean LOI was 10.0 (range, 4 to 26). RESULTS: Total surface damage scores were significantly higher in the UHMWPE group versus the XLPE group (57.3 versus 44.2, P = .003). SEM demonstrated fracture initiation at the posterior edge of the post in 10 of 13 cases. UHMWPE fracture surfaces posts had more tufted, irregularly clamshell features, while XLPE posts had more precise clamshell marking and a diamond pattern in the region of acute, final fracture. CONCLUSION: Characteristics of PS post fracture differed between XLPE and UHMWPE implants, with fractures occurring in the XLPE with less generalized surface damage, after a shorter LOI, and with SEM evaluation indicative of a more brittle fracture pattern.


Assuntos
Artroplastia do Joelho , Fraturas Ósseas , Prótese do Joelho , Polietileno , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Artroplastia do Joelho/efeitos adversos , Fraturas Ósseas/cirurgia , Articulação do Joelho/cirurgia , Desenho de Prótese , Falha de Prótese
8.
J Knee Surg ; 36(1): 6-17, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33932947

RESUMO

Lymphocyte transformation testing (LTT) is often used in the workup for possible metal allergy after total knee arthroplasty (TKA) but the correlation of this test with other diagnostic metal-allergy findings in patients undergoing revision TKA for suspected metal allergy has not been established. A single-center, single-surgeon cohort of 19 TKAs in which both components were revised for presumed implant-related metal allergy based on history, physical, and LTT testing, to nonnickel-containing implants were retrospectively identified. Histopathologic samples obtained intraoperatively were semiquantitatively analyzed using both the Hospital for Special Surgery (HSS) synovial pathology score and the Campbell aseptic lymphocyte-dominant vasculitis-associated lesion (ALVAL) score. As histopathology control group, we included in the study an additional cohort of 17 patients who received aseptic revision TKA and had no history of reported or tested metal sensitivity. All preoperative LTT results were highly reactive to nickel. However, this did not correlate with local periarticular tissue response in 18 of 19 cases which demonstrated a low HSS synovial score (mean: 3.8 ± 2.8, of a maximum score of 28) and the low Campbell ALVAL scores (mean: 2.5/10 ± 1.3, of a maximum score of 10). There were not any significant differences between the study group (suspected implant-related metal allergy) and the control group (nonsuspected implant-related metal allergy) in regard to (1) the Campbell score and (2) the HSS synovial inflammatory score. Knee Society Clinical Rating System (KSCRS) function score improved significantly after revision (mean postoperative increase: 34.0 ± 17. 2; p < 0.001), as well as mean visual analog scale (VAS) pain (mean postoperative decrease: 33.3 ± 26.4; p < 0.01) score. The short-term survival rate (at mean follow-up of 26.1 months) of this patient cohort was 100%. In this cohort of revised TKA patients with suspected nickel allergy based on clinical presentation and LTT positive results, intraoperative histopathology was essentially normal. However, all patients with suspected nickel allergy showed a significant clinical and functional improvement with excellent short-term survival rates. The clinical significance of a positive LTT needs further study.


Assuntos
Artroplastia do Joelho , Hipersensibilidade , Prótese do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Níquel/efeitos adversos , Estudos Retrospectivos , Reoperação , Hipersensibilidade/etiologia , Hipersensibilidade/cirurgia , Prótese do Joelho/efeitos adversos
9.
Arch Orthop Trauma Surg ; 143(2): 785-789, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34546422

RESUMO

INTRODUCTION: In the acute phase of COVID-19, elevated D-dimer levels indicate a hypercoagulable state putting the patients at increased risk for venous thromboembolic disease (VTE). It is unclear, if prior COVID-19 disease increases the risk for VTE after total joint arthroplasty (TJA) and if D-dimer levels can be used to identify patients at risk. MATERIALS AND METHODS: D-Dimer levels of 313 consecutive SARS-CoV-2 IgG-positive and 2,053 -negative patients undergoing TJA between 05/20 and 12/20 were evaluated. D-Dimer levels were divided into three groups: < 200 ng/ml, 200-400 ng/ml, and > 400 ng/ml D-dimer units (DDU). 277 SARS-CoV-2 IgG-positive patients underwent a Doppler ultrasound to rule out deep-vein thrombosis (DVT) 4-6 weeks after TJA. RESULTS: D-Dimer levels did not differ significantly between SARS-CoV-2 IgG-positive and -negative patients (p value 0.53). Among SARS-CoV-2 IgG-negative patients, 1687 (82.17%) had D-dimer levels < 200 ng/ml, 256 (12.47%) between 200 and 400 ng/ml, and 110 (5.36%) > 400 ng/ml. Of the SARS-CoV-2 IgG-positive patients, 257 (83.71%) had D-dimer levels < 200 ng/ml, 34 (11.07%) between 200 and 400 ng/ml, and 16 (5.21%) > 400 ng/ml. A postoperative DVT was detected in nine patients (2.9%) in the SARS-CoV-2 IgG-positive group and a PE in one patient (0.3%). 7/229 patients with < 200 ng/ml (3.1%), 1/28 patients (3.6%) with 200-400 ng/ml and 1/9 patients (11.1%) with D-dimer levels > 400 ng/ml had a DVT or PE (p = 0.43). CONCLUSIONS: The findings of this investigation suggest there is no difference in D-dimer levels between SARS-CoV-2 IgG-positive and -negative patients undergoing TJA. Although there is a trend for increased VTE rates with increased D-dimer levels, routine D-dimer testing is not recommended based on the current data. SARS-CoV-2 IgG-positive patients have a low risk of VTE in the current study.


Assuntos
COVID-19 , Tromboembolia Venosa , Trombose Venosa , Humanos , COVID-19/complicações , Tromboembolia Venosa/etiologia , SARS-CoV-2 , Trombose Venosa/etiologia , Artroplastia/efeitos adversos
10.
Arch Orthop Trauma Surg ; 143(1): 311-315, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34302523

RESUMO

INTRODUCTION: A history of COVID-19 (Coronavirus Disease 2019), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) may have an impact on hemoglobin and ferritin levels predisposing patients to increased blood transfusion requirements following total joint arthroplasty (TJA). The current study compares ferritin levels, hemoglobin levels, and transfusion rates between SARS-CoV-2 IgG positive and SARS-CoV-2 IgG negative TJA patients. MATERIALS AND METHODS: Preoperative ferritin levels, pre- and postoperative hemoglobin levels, postoperative change in hemoglobin, and transfusion rates of 385 consecutive SARS-CoV-2 IgG positive patients undergoing TJA were compared to those of 5156 consecutive SARS-CoV-2 IgG negative patients undergoing TJA. RESULTS: Preoperative hemoglobin levels were significantly lower in SARS-CoV-2 IgG positive patients [13.3 g/dL (range 8.9-17.7 g/dL)] compared to 13.5 g/dl (7.3-18.3 g/dL; p value 0.03). Ferritin levels were significantly lower in SARS-CoV-2 IgG positive patients (mean of 106.1 ng/ml (2.1-871.3.3 ng/ml) vs. 123.7 ng/ml (1.4-1985 ng/ml) (p value 0.02)). Hemoglobin on postoperative day (POD) one, after four-six weeks, and transfusion rates did not differ between the two groups. CONCLUSION: Although preoperative hemoglobin and ferritin levels are lower in SARS-CoV2 IgG positive patients, there was no difference in hemoglobin on POD one, recovery of hemoglobin levels at four-six weeks postoperatively, and transfusion rates after surgery. Routine ferritin testing prior to TJA is not recommended in SARS-CoV-2 IgG positive patients.


Assuntos
COVID-19 , Ferritinas , Hemoglobinas , Humanos , Transfusão de Sangue , Ferritinas/sangue , Hemoglobinas/análise , Hemorragia , Imunoglobulina G , SARS-CoV-2 , Período Pré-Operatório
11.
Arch Orthop Trauma Surg ; 143(3): 1579-1591, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35378597

RESUMO

INTRODUCTION: Elective orthopedic care, including in-person office visits and physical therapy (PT), was halted on March 16, 2020, at a large, urban hospital at the onset of the local COVID-19 surge. Post-discharge care was provided predominantly through a virtual format. The purpose of this study was to assess the impact of postoperative care disruptions on early total knee arthroplasty (TKA) outcomes, specifically 90-day complications, 120-day rate of manipulation under anesthesia (MUA) and 1-year patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Institutional records were queried to identify 624 patients who underwent primary, unilateral TKA for osteoarthritis and who were discharged home between 1/1/20 and 3/15/20. These patients were compared to 558 controls discharged between 1/1/19 and 3/15/2019. Cohort demographics and in-hospital characteristics were equivalent apart from inpatient morphine milligram equivalent (MME) consumption. Patient-reported access to PT (p < 0.001) and post-discharge care (p < 0.001) were worse among study patients. Study patients were prescribed fewer post-discharge PT sessions (19.8 vs. 23.5; p < 0.001) and utilized telehealth more frequently (p < 0.001). Mann-Whitney U, T, Fisher's Exact, and chi-squared tests were used to compare outcomes. RESULTS: Ninety-day CMS complications were lower among study patients (3.5% vs. 5.9%; p = 0.05). Rates of MUA were similar between groups. Study patients reported similar PROMs and marginally inferior VR-12 mental and LEAS functional outcomes at 1 year. CONCLUSION: Disruptions to elective orthopedic care in March 2020 seemed to have had no major consequences on clinical outcomes for TKA patients. Our findings question the usefulness of pre-pandemic post-discharge protocols, which may over-emphasize in-person visits and PT.


Assuntos
Artroplastia do Joelho , COVID-19 , Humanos , Artroplastia do Joelho/efeitos adversos , Cuidados Pós-Operatórios , Assistência ao Convalescente , Alta do Paciente , Medidas de Resultados Relatados pelo Paciente , Estudos Retrospectivos
12.
Arthroplast Today ; 15: 19-23, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35368851

RESUMO

We present a 67-year-old male patient who presented with insidious worsening of right hip pain over a 6-month period with clinical and radiographic evidence of severe osteoarthritis. The patient underwent a primary total hip arthroplasty where the femoral head specimen was sent to pathology as a routine specimen. Pathology results demonstrated metastatic adenocarcinoma of prostate origin. The present case emphasizes the importance of routine pathologic examination of femoral head specimens retrieved during total hip arthroplasty, particularly since this was a clinically unsuspected finding. Although cases like these are rare and the process of routine pathologic examination raises a concern for economic implications, a timely diagnosis of adenocarcinoma provides benefits for the patient, for which cost-benefit ratios are difficult to quantify.

13.
Clin Orthop Relat Res ; 480(8): 1604-1615, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35323146

RESUMO

BACKGROUND: In TKA, soft tissue balancing is assessed through manual intraoperative trialing. This assessment is a physical examination via manually applied forces at the ankle, generating varus and valgus moments at the knee while the surgeon visualizes the lateral and medial gaps at the joint line. Based on this examination, important surgical decisions are made that influence knee stability, such as choosing the polyethylene insert thickness. Yet, the applied forces and the assessed gaps in this examination represent a qualitative art that relies on each surgeon's intuition, experience, and training. Therefore, the extent of variation among surgeons in conducting this exam, in terms of applied loads and assessed gaps, is unknown. Moreover, whether variability in the applied loads yields different surgical decisions, such as choice of insert thickness, is also unclear. Thus, surgeons and developers have no basis for deciding to what extent the applied loads need to be standardized and controlled during a knee balance exam in TKA. QUESTIONS/PURPOSES: (1) Do the applied moments in soft tissue assessment differ among surgeons? (2) Do the assessed gaps in soft tissue assessment differ among surgeons? (3) Is the choice of insert thickness associated with the applied moments? METHODS: Seven independent human cadaveric nonarthritic lower extremities from pelvis to toe were acquired (including five females and two males with a mean age of 73 ± 7 years and a mean BMI of 25.8 ± 3.8 kg/m 2 ). Posterior cruciate ligament substituting (posterior stabilized) TKA was performed only on the right knees. Five fellowship-trained knee surgeons (with 24, 15, 15, 7, and 6 years of clinical experience) and one chief orthopaedic resident independently examined soft tissue balance in each knee in extension (0° of flexion), midflexion (30° of flexion), and flexion (90° of flexion) and selected a polyethylene insert based on their assessment. Pliable force sensors were wrapped around the leg to measure the loads applied by each surgeon. A three-dimensional (3D) motion capture system was used to measure knee kinematics and a dynamic analysis software was used to estimate the medial and lateral gaps. We assessed (1) whether surgeons applied different moments by comparing the mean applied moment by surgeons in extension, midflexion, and flexion using repeated measures (RM)-ANOVA (p < 0.05 was assumed significantly different); (2) whether surgeons assessed different gaps by comparing the mean medial and lateral gaps in extension, midflexion, and flexion using RM-ANOVA (p < 0.05 was assumed significantly different); and (3) whether the applied moments in extension, midflexion, and flexion were associated with the insert thickness choice using a generalized estimating equation (p < 0.05 was assumed a significant association). RESULTS: The applied moments differed among surgeons, with the largest mean differences occurring in varus in midflexion (16.5 Nm; p = 0.02) and flexion (7.9 Nm; p < 0.001). The measured gaps differed among surgeons at all flexion angles, with the largest mean difference occurring in flexion (1.1 ± 0.4 mm; p < 0.001). In all knees except one, the choice of insert thickness varied by l mm among surgeons. The choice of insert thickness was weakly associated with the applied moments in varus (ß = -0.06 ± 0.02 [95% confidence interval -0.11 to -0.01]; p = 0.03) and valgus (ß = -0.09 ± 0.03 [95% CI -0.18 to -0.01]; p= 0.03) in extension and in varus in flexion (ß = -0.11 ± 0.04 [95% CI -0.22 to 0.00]; p = 0.04). To put our findings in context, the greatest regression coefficient (ß = -0.11) indicates that for every 9-Nm increase in the applied varus moment (that is, 22 N of force applied to the foot assuming a shank length of 0.4 m), the choice of insert thickness decreased by 1 mm. CONCLUSION: In TKA soft tissue assessment in a human cadaver model, five surgeons and one chief resident applied different moments in midflexion and flexion and targeted different gaps in extension, midflexion, and flexion. A weak association between the applied moments in extension and flexion and the insert choice was observed. Our results indicate that in the manual assessment of soft tissue, changes in the applied moments of 9 and 11 Nm (22 to 27 N on the surgeons' hands) in flexion and extension, respectively, yielded at least a 1-mm change in choice of insert thickness. The choice of insert thickness may be more sensitive to the applied moments in in vivo surgery because the surgeon is allowed a greater array of choices beyond insert thickness. CLINICAL RELEVANCE: Among five arthroplasty surgeons with different levels of experience and a chief resident, subjective soft tissue assessment yielded 1 to 2 mm of variation in their choice of insert thickness. Therefore, developers of tools to standardize soft tissue assessment in TKA should consider controlling the force applied by the surgeon to better control for variations in insert selection.


Assuntos
Artroplastia do Joelho , Instabilidade Articular , Osteoartrite do Joelho , Cirurgiões , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Instabilidade Articular/etiologia , Articulação do Joelho/cirurgia , Masculino , Osteoartrite do Joelho/cirurgia , Polietilenos , Amplitude de Movimento Articular
14.
Radiology ; 304(1): 128-136, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35315718

RESUMO

Background Because loosening of total knee arthroplasty (TKA) occurs due to poor osseous integration at component-bone interfaces, interface assessment may be helpful in diagnosing loosening at MRI. Purpose To determine interreader reproducibility for characterizing component interfaces and diagnosing loosening and to evaluate the diagnostic performance of MRI for diagnosing loosening after TKA compared with radiography. Materials and Methods Consecutive knees with TKA that underwent revision between July 2018 and June 2019 and were imaged at MRI and radiography were included in this retrospective study. Interface type (normal, fibrous membrane, fluid, or osteolysis), percent integration (<33%, 33%-66%, or >66%), and presence of bone marrow edema pattern were assessed. Loosening was diagnosed at MRI if no or almost no normal interface was present. Sensitivity and specificity were compared with radiographs by using surgical findings as reference. Gwet agreement coefficient evaluated interreader reproducibility between two readers and multivariable logistic regression assessed risk factors for loosening. Results Among 116 knees in 114 patients (mean age, 63 years ± 10 [SD]; 59 women), 61 of 116 knees (52.6%) had at least one loose component. Interreader reproducibility of MRI was substantial to excellent (Gwet agreement coefficient, 0.67-0.96). Loosening was associated with fluid interface (odds ratio [OR], 20.1; 95% CI: 5.7, 70.9) or osteolysis (OR, 3.1; 95% CI: 1.8, 5.3), absence of any normal interface (OR, 11.8; 95% CI: 6.3, 22.2), poor (<33%) osseous integration (OR, 20.4; 95% CI: 9.7, 42.6), and bone marrow edema pattern (OR, 4.7; 95% CI: 2.8, 7.8). Sensitivity and specificity of MRI for loosening were 84% (27 of 32; 95% CI: 72, 97) and 85% (71 of 84; 95% CI: 77, 92) for the patellar, 31% (eight of 26; 95% CI: 13, 49) and 100% (90 of 90; 95% CI: 100, 100) for the femoral, and 81% (22 of 27; 95% CI: 66, 96) and 98% (87 of 89; 95% CI: 95, 100) for the tibial component, respectively. MRI had higher sensitivity (84% vs 31%; P < .001) but lower specificity (85% vs 96%; P = .003) for patellar component loosening than did radiography, respectively, whereas no evidence of a difference was found for femoral (sensitivity and specificity, MRI vs radiography: 31% vs 46% [P = .20] and 100% vs 99% [P > .99], respectively) or tibial (sensitivity and specificity, MRI vs radiography: 81% vs 70% [P = .16] and 98% vs 97% [P = .32], respectively) component loosening. Conclusion MRI demonstrated substantial to excellent interreader reproducibility and higher sensitivity than did radiography for diagnosing patellar component loosening after total knee arthroplasty. © RSNA, 2022 Online supplemental material is available for this article.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteólise , Artroplastia do Joelho/efeitos adversos , Feminino , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Imageamento por Ressonância Magnética/efeitos adversos , Pessoa de Meia-Idade , Osteólise/diagnóstico por imagem , Falha de Prótese , Radiografia , Reoperação/efeitos adversos , Reprodutibilidade dos Testes , Estudos Retrospectivos
15.
J Arthroplasty ; 37(7): 1278-1282, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35218911

RESUMO

BACKGROUND: Computer-assisted surgery that does not utilize femoral canal instrumentation is theorized to have less blood loss. However, there is a paucity of data on this, particularly in the era of tranexamic acid use. We sought to analyze the association of computer navigation with total calculated blood loss and transfusion rate in patients undergoing primary total knee arthroplasty (TKA). METHODS: We identified 14,890 patients who underwent unilateral primary TKA at a single institution from 2016 to 2020. Computer-assisted surgery in the form of an accelerometer or robotics was utilized in 4,165 TKAs (28%). Drains were utilized in 4,860 TKAs (32%). We used multivariate logistic regression analysis to determine if computer navigation reduced the rate of blood transfusion and linear regression analysis to determine the impact of computer navigation on blood loss. RESULTS: In total, 542 patients (3.6%) underwent a transfusion. The average change in hemoglobin (Hgb) was 2.1 g/dL (standard deviation [SD] 0.91) and average total calculated blood loss was 310 mL (SD = 154). In a multivariate regression model, computer navigation was not protective of transfusion (odds ratio [OR] 1.04, P = .73). Preoperative Hgb <10 (OR 10.5, P < .0001) and drain use (OR 2.25, P < .0001) were the most significant risk factors for transfusion. In a linear regression model, computer navigation reduced blood loss by 19 mL (SD 2.94, P < .0001) per case. CONCLUSION: In this large retrospective cohort analysis of contemporary TKA patients, computer-assisted surgery that eliminates intramedullary femoral canal instrumentation during primary TKA was not associated with reduced transfusion rates and had minimal differences in overall blood loss.


Assuntos
Artroplastia do Joelho , Cirurgia Assistida por Computador , Ácido Tranexâmico , Artroplastia do Joelho/métodos , Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue , Hemoglobinas/análise , Humanos , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Ácido Tranexâmico/uso terapêutico
16.
J Knee Surg ; 35(2): 198-203, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32906160

RESUMO

Implant malalignment during total knee arthroplasty (TKA) may lead to suboptimal postoperative outcomes. Accuracy studies are typically performed with experienced surgeons; however, it is important to study less experienced surgeons when considering teaching hospitals where younger surgeons operate. Therefore, this study assessed whether robotic-arm assisted TKA (RATKA) allowed for more accurate and precise implant position to plan when compared with manual techniques when the surgery is performed by in-training orthopaedic surgical fellows. Two surgeons, currently in their fellowship training and having minimal RATKA experience, performed a total of six manual TKA (MTKA) and six RATKAs on paired cadaver knees. Computed tomography scans were obtained for each knee pre- and postoperatively. These scans were analyzed using a custom autosegmentation and autoregistration process to compare postoperative implant position with the preoperative planned position. Mean system errors and standard deviations were compared between RATKA and MTKA for the femoral component for sagittal, coronal, and axial planes and for the tibial component in the sagittal and coronal planes. A 2-Variance testing was performed using an α = 0.05. Although not statistically significant, RATKA was found to have greater accuracy and precision to plan than MTKA for: femoral axial plane (1.1° ± 1.1° vs. 1.6° ± 1.3°), coronal plane (0.9° ± 0.7° vs. 2.2° ± 1.0°), femoral sagittal plane (1.5° ± 1.3° vs. 3.1° ± 2.1°), tibial coronal plane (0.9° ± 0.5° vs. 1.9° ± 1.3°), and tibial sagittal plane (1.7° ± 2.6° vs. 4.7° ± 4.1°). There were no statistical differences between surgical groups or between the two surgeons performing the cases. With limited RATKA experience, fellows showed increased accuracy and precision to plan for femoral and tibial implant positions. Furthermore, these results were comparable to what has been reported for an experienced surgeon performing RATKA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Procedimentos Cirúrgicos Robóticos , Cirurgiões , Cirurgia Assistida por Computador , Bolsas de Estudo , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia
17.
J Knee Surg ; 35(13): 1401-1408, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33618396

RESUMO

The articular design of a polyethylene insert influences the kinematics and overall function of a total knee arthroplasty (TKA). Standard symmetric posterior-stabilized and cruciate-retaining polyethylene designs have a long track record of high patient satisfaction and longevity in TKA. However, the number and variety of polyethylene inserts and articulations have continued to evolve in an attempt to better replicate native knee kinematics or provide additional constraint. Ultracongruent polyethylene designs have been touted as increasing stability while maintaining the benefits of cruciate-retaining knees. Medial pivot and lateral/dual pivot polyethylene designs were introduced to mimic more normal knee kinematics with regard to femoral rollback. Further, with increasing recognition of knee instability as a cause for persistent symptoms and revision TKA, the utilization of midlevel constraint polyethylene inserts has been increasing, with multiple implant companies offering an insert design with increased constraint for use with a primary femoral component. In this rapidly evolving arena in with a myriad of options available, surgeons should be knowledgeable about the design concepts and their applicable uses for specific patient scenarios. Future research is needed to better understand whether a particular type or design of polyethylene insert and articulation leads to improved patient reported outcomes, improved replication of knee kinematics, and long-term durable implant survivorship.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Polietileno , Desenho de Prótese , Amplitude de Movimento Articular , Articulação do Joelho/cirurgia , Fenômenos Biomecânicos
18.
J Arthroplasty ; 37(3): 544-548, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34883254

RESUMO

BACKGROUND: There is a paucity of data on blood loss and the risk of allogeneic blood transfusion after simultaneous bilateral total hip arthroplasty (SBTHA) with contemporary blood management including neuraxial anesthesia, routine tranexamic acid use, and a restrictive transfusion protocol. As such, we sought to determine the in-hospital outcomes of SBTHA, specifically analyzing blood loss and the rate and risk factors for transfusion. METHODS: We identified 191 patients who underwent SBTHA at a single institution from 2016 to 2019. No drains were utilized and no patients donated blood preoperatively. Mean age was 59 years with 96 females (50.3%). The surgical approach was posterior in 138 (72.3%) and direct anterior in 53 (27.7%) patients. We analyzed blood loss, the rate of allogeneic blood transfusions, and in-hospital thromboembolic complications. We analyzed risk factors for transfusion with a logistic regression analysis. RESULTS: Twenty-two patients (11.5%) underwent allogeneic blood transfusion. All transfused patients were female. Univariate analysis revealed female gender as a transfusion risk factor since it had statistically significant higher proportion in the transfusion group than the nontransfusion group (100% vs 43.5%, respectively, P < .001). We did not identify any other singular significant risk factors for transfusion in a multivariable regression analysis. However, females with a preoperative Hb <12 had an elevated risk of transfusion at 37.5% (15/40 patients). CONCLUSION: With contemporary perioperative blood management protocols, there is a relatively low (11.5%) risk of a blood transfusion after SBTHA. Females with a lower preoperative Hb (<12 g/dL) had the highest risk of transfusion at 37.5%.


Assuntos
Antifibrinolíticos , Artroplastia de Quadril , Transplante de Células-Tronco Hematopoéticas , Ácido Tranexâmico , Antifibrinolíticos/uso terapêutico , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Perda Sanguínea Cirúrgica , Transfusão de Sangue , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Ácido Tranexâmico/uso terapêutico
19.
J Arthroplasty ; 37(3): 444-448.e1, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34808278

RESUMO

BACKGROUND: Although total hip arthroplasty (THA) and total knee arthroplasty (TKA) are transitioning to surgery centers, there remain limited data on trends, comorbidities, and complications in patients discharged the same day of surgery. In addition, many studies are limited to the Medicare population, excluding a large proportion of outpatient surgery patients. METHODS: Primary, elective THA/TKA cases between 2010 and 2017 were retrospectively identified using the PearlDiver All-Payer Database and separated based on surgery as well as same-day discharge (SDD) or non-SDD. Data were collected on demographics, rates, comorbidities, and complications. Multivariable logistic regression determined adjusted odds ratios (ORs) for 90-day complications requiring readmission for each group. RESULTS: In total, 1,789,601 (68.8% TKA, 31.2% THA) patients were identified where 2.9% of TKAs and 2.2% of THAs were SDD. Annual SDD rates are increasing, with a 15.8% mean annual change for SDD-THA and 11.1% for SDD-TKA (P < .001). SDD patients were younger with fewer comorbidities (P < .001). Regression analysis showed an overall slightly higher OR of complications requiring readmission for SDD-TKA vs non-SDD-TKA (OR 1.14, 95% confidence interval [CI] 1.07-1.21, P < .001). There was no significant difference for SDD-THA vs non-SDD-THA (OR 1.03, 95% CI 0.94-1.13, P = .49). In univariate analysis, SDD-THA vs SDD-TKA had more mechanical complications (P < .001), but less pulmonary embolisms (P < .001). Regression analysis showed a slightly higher risk of complications for SDD-THA vs SDD-TKA (OR 1.19, 95% CI 0.99-1.44, P = .05). CONCLUSION: The prevalence of SDD is rising. SDD-THA is increasing more rapidly than SDD-TKA. SDD patients are generally younger with fewer comorbidities. SDD-TKA has slightly higher odds of complications requiring readmission than non-SDD-TKA. SDD-THA and SDD-TKA have different complication profiles.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Humanos , Tempo de Internação , Alta do Paciente , Readmissão do Paciente , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco
20.
JBJS Case Connect ; 11(3)2021 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-34449449

RESUMO

CASE: A 69-year-old woman underwent revision total knee arthroplasty for patellar component aseptic loosening. The periprosthetic tissue demonstrated histologic features of an adaptive immune response (aseptic lymphocyte-dominant vasculitis-associated lesion [ALVAL]). No particles of corrosion debris were identified. The inflammation seemed to be associated with zirconium oxide (ZrO2) particles added as a bone cement radio-opacifier. CONCLUSION: The factors responsible for the adaptive immune response cannot be determined with certainty; however, this is the first reported case of ALVAL associated with ZrO2-containing bone cement. Previous reports describing ALVAL around failed total knee prostheses have not included observations about the type of contrast material added to cement.


Assuntos
Artroplastia do Joelho , Zircônio , Imunidade Adaptativa , Idoso , Feminino , Humanos , Falha de Prótese , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA