Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Int J Radiat Oncol Biol Phys ; 106(5): 1052-1062, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32007365

RESUMO

PURPOSE: The aim of this study was to investigate the influence of brachytherapy technique and applicator type on target dose, isodose surface volumes, and organ-at-risk (OAR) dose. METHODS AND MATERIALS: Nine hundred two patients treated with tandem/ovoids (T&O) (n = 299) and tandem/ring (T&R) (n = 603) applicators from 16 EMBRACE centers were analyzed. Patients received external beam radiation therapy and magnetic resonance imaging guided brachytherapy with dose prescription according to departmental practice. Centers were divided into 4 groups, according to applicator/technique: Ovoids and ring centers treating mainly with the intracavitary (IC) technique and ovoids and ring centers treating routinely with the intracavitary/interstitial (IC/IS) technique. V85Gy EQD210, CTVHR D90% (EQD210), and bladder, rectum, sigmoid, and vaginal 5-mm lateral-point doses (EQD23) were evaluated among center groups. Differences between T&O and T&R were tested with multivariable analysis. RESULTS: For similar point A doses, mean CTVHR D90% was 3.3 Gy higher and V85Gy was 23% lower for ring-IC compared with ovoids-IC centers (at median target volumes). Mean bladder/rectum doses (D2cm3 and ICRU-point) were 3.2 to 7.7 Gy smaller and vaginal 5-mm lateral-point was 19.6 Gy higher for ring-IC centers. Routine use of IC/IS technique resulted in increased target dose, whereas V85Gy was stable (T&R) or decreased (T&O); reduced bladder and rectum D2cm3 and bladder ICRU-point by 3.5 to 5.0 Gy for ovoids centers; and similar OAR doses for ring centers. CTVHR D90% was 2.8 Gy higher, bladder D2cm3 4.3 Gy lower, rectovaginal ICRU-point 4.8 Gy lower, and vagina 5-mm lateral-point 22.4 Gy higher for ring-IC/IS versus ovoids-IC/IS centers. The P values were <.002 for all comparisons. Equivalently, significant differences were derived from the multivariable analysis. CONCLUSIONS: T&R-IC applicators have better target dose and dose conformity than T&O-IC in this representative patient cohort. IC applicators fail to cover large target volumes, whereas routine application of IC/IS improves target and OAR dose considerably. Patients treated with T&R show a more favorable therapeutic ratio when evaluating target, bladder/rectum doses, and V85Gy. A comprehensive view on technique/applicators should furthermore include practical considerations and clinical outcome.


Assuntos
Braquiterapia/instrumentação , Estudos Observacionais como Assunto , Neoplasias do Colo do Útero/radioterapia , Braquiterapia/efeitos adversos , Feminino , Humanos , Pessoa de Meia-Idade , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica
3.
Eur J Oncol Nurs ; 29: 31-38, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28720263

RESUMO

PURPOSE: To establish a comprehensive set of recommendations for the service structure and skill set of nurses and allied healthcare professionals in prostate cancer care. METHODS: Using components of formal consensus methodology, a 30-member multidisciplinary panel produced 53 items for discussion relating to the provision of care for prostate cancer patients by specialist nurses and allied healthcare professionals. Items were developed by two rounds of email correspondence in which, first, items were generated and, second, items refined to form the basis of a consensus meeting which constituted the third round of review. The fourth and final round was an email review of the consensus output. RESULTS: The panel agreed on 33 items that were appropriate for recommendations to be made. These items were grouped under categories of "Environment" and "Patient Pathway" and included comments on training, leadership, communication and quality assessment as well as specific items related to prostate diagnosis clinics, radical treatment clinics and follow-up survivor groups. CONCLUSIONS: Specialist nurses and allied healthcare professionals play a vital role alongside urologists and oncologists to provide care to men with prostate cancer and their families. We present a set of standards and consensus recommendations for the roles and skill-set required for these practitioners to provide gold-standard prostate cancer care. These recommendations could form the basis for development of comprehensive integrated prostate cancer pathways in prostate cancer centres as well as providing guidance for any units treating men with prostate cancer.


Assuntos
Competência Clínica/normas , Pessoal de Saúde/normas , Saúde Holística/normas , Enfermagem Oncológica/normas , Guias de Prática Clínica como Assunto , Neoplasias da Próstata/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade
4.
Brachytherapy ; 12(2): 107-13, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22732322

RESUMO

PURPOSE: This study directly compares four dosimetric techniques for balloon-based partial breast brachytherapy: single source, standard line source, and both forward planned and inverse planned multilumen (ML). A standard line source plan is presented to be used in a single catheter or as a starting point for forward planned ML. METHODS AND MATERIALS: The study population consists of 12 patients previously treated with a single lumen. Inverse plans were created for 7 patients and used to create a standard line source plan. ML plans were created on the same patient data sets. The dosimetric aims were as follows: PTV_EVAL (planning target volume for evaluation) D95 (dose received [%] by 95% of PTV_EVAL volume)≥95% of the prescribed dose (PD), the maximum skin and rib dose ≤125% of prescription dose, breast V150 (volume [cc] receiving 150% of the PD)≤50cc, and V200 (volume [cc] receiving 200% of the PD)≤10cc. RESULTS: The number of patients fulfilling all dosimetric constraints went from 1 patient of 12 with a single catheter to 6 patients of 12 with inverse planned ML and 7 patients of 12 with forward planned ML. PTV_EVAL D95 increased significantly with the standard line source plans and ML plans when compared with the single-source plans. Forward planning took, on average, 7min longer than inverse planning. CONCLUSION: Multiple sources in a single catheter improve coverage at catheter ends, whereas ML can further improve coverage and reduce dose to organs at risk. Using a standard line source as a starting point for forward planning ML means increase in planning time is kept to a minimum, making it a practicable option for centers without inverse planning software. Patients previously ineligible for treatment with a single catheter may be treated using ML.


Assuntos
Algoritmos , Braquiterapia/instrumentação , Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Feminino , Humanos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA