Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Arthroplasty ; 30(9): 1607-17, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25956526

RESUMO

The articular surface replacement (ASR) total hip arthroplasty (THA) showed accelerated failure rates due to adverse-reaction to metal debris (ARMD). Literature correlating preoperative with intraoperative revision findings respectively post-revision outcome results are rare. 30 of 99 available ASR THA were revised due to ARMD. Mean post-revision follow-up term was 2.3 years. In part, preoperative data did not correlate with intraoperative revision findings. ARMD was even found in asymptomatic patients with non-elevated ion levels. Postoperative pain and metal ions decreased significantly (P ≤ 0.016). Cobalt decreased faster than chrome. Patients with intraoperative pseudotumors, osteolysis or bilateral THA did not have higher pre- or postoperative ion values (P ≥ 0.053). Females showed higher postoperative chrome levels (P=0.031). One major post-revision complication (femoral nerve palsy) and one re-revision (late onset infection) occurred.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Dor Pós-Operatória/prevenção & controle , Reoperação/métodos , Adulto , Artroplastia de Quadril/instrumentação , Doenças das Cartilagens , Cromo/química , Cobalto/química , Feminino , Nervo Femoral/lesões , Nervo Femoral/patologia , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Osteólise , Período Pós-Operatório , Desenho de Prótese , Falha de Prótese , Amplitude de Movimento Articular , Reoperação/instrumentação , Resultado do Tratamento , Adulto Jovem
2.
J Arthroplasty ; 29(9): 1795-802, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24906519

RESUMO

In the literature, studies of computer-assisted total knee arthroplasty (TKA) after mid-term period are not conclusive and long-term data are rare. In a prospective, randomized, comparative study 100 conventional TKAs (group REG) were compared with 100 computer-assisted TKAs (group NAV). Minimum follow-up was 5years. No difference in implant failure was found with 1.1% in group NAV versus 4.6% in group REG (P=0.368). Group NAV showed a significantly less mean deviation of mechanical limb axis (P=0.015), more TKAs (90% versus 81% in group REG) were within 3° varus/valgus and a higher tibial slope and lateral distal femoral angle (LDFA) accuracy was found (P≤0.034). Clinical investigational parameters showed no differences (P≥0.058). Insall and HSS score total were also higher in group NAV (P≤0.016).


Assuntos
Artroplastia do Joelho/mortalidade , Artroplastia do Joelho/métodos , Cirurgia Assistida por Computador/mortalidade , Cirurgia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Cirurgia Assistida por Computador/efeitos adversos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Resultado do Tratamento
3.
Knee Surg Sports Traumatol Arthrosc ; 18(3): 359-66, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19847404

RESUMO

Several choices of instrument systems are available for minimally invasive surgical approaches. There are reports that one alternative, the quadriceps sparing, side-cutting instrumentation, results in diminished implantation accuracy. A total of 108 patients were randomized to undergo TKA either using side-cutting implant instrumentation (Group A) or anterior-posterior mini-incision instrumentation (Group B). All TKAs were operated on with a minimal invasive, mini-midvastus surgical approach. 50% of the TKAs were performed with computer-assistance in each cohort. The radiographic parameters, clinical outcomes and knee scores were evaluated preoperatively and 3 months postoperative. In Group B, we found significantly higher accuracy for the mechanical axis of the limb (range +/-3 degrees: Group A 54% versus Group B 89%, p = <0.001), medial proximal tibial angle (range +/-3 degrees: Group A 85% versus Group B 98%, p = <0.027) and tibial slope (range +/-3 degrees: Group A 59% versus Group B 85%, p = <0.007). The application of the navigation system could only significantly reduce outliers (accuracy >3 degrees) in Group B. Clinical outcomes and knee scores were similar in both groups and were not influenced by computer-assistance. Using the anterior-posterior, mini-incision instruments for minimally invasive TKA will lead to higher implantation accuracy when compared to the quadriceps sparing side-cutting instrumentation. The navigation technique could not compensate for shortcomings of the side-cutting instrumentation. The clinical relevance of this study is that the quadriceps sparing side-cutting instrumentation should not be used for TKA because of unacceptable reduced implantation accuracy.


Assuntos
Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Cirurgia Assistida por Computador
4.
Knee Surg Sports Traumatol Arthrosc ; 17(4): 374-81, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19132345

RESUMO

A new generation of implantation instruments were developed for quadriceps sparing surgical approaches during total knee arthroplasty (TKA). There is little information on the accuracy of the bone cuts performed with the side-cutting technique. A total of 100 patients were randomized to undergo computer-assisted TKA or non-navigated TKA using a mini-subvastus surgical approach and side-cutting implant instrumentation. The radiographic parameters, clinical outcomes and knee scores were evaluated 3 months postoperative. The mechanical axis of the limb was within 3 degrees varus/valgus in 76% of the patients who had navigated procedures versus 66% of patients who had conventional surgery. The tibial slope showed a rate of inaccuracy of 3 degrees or less for 78% of the patients in the navigated total knee arthroplasty group versus 66% of the patients in the conventional group. Clinical outcomes and knee scores were similar in both groups. The navigation technique could not compensate for shortcomings of the implantation instruments.


Assuntos
Artroplastia do Joelho/métodos , Implantação de Prótese/métodos , Cirurgia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS