Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Lasers Surg Med ; 56(5): 508-522, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38576388

RESUMO

OBJECTIVES: Knowledge of the physical effects of pulsed dye laser (PDL) treatment of psoriatic lesions is essential in unraveling the remedial mechanisms of this treatment and hence also in maximizing in its disease-modifying potential. Therefore, the main objective of this study was to provide estimates of these physical effects (for laser wavelengths of 585 and 595 nm), with the aim of identifying pathogenic processes that may be affected by these conditions. METHODS: We modeled the laser light propagation and subsequent photothermal heating by numerically solving the transient diffusion and heat equations simultaneously. To this end, we used the finite element method in conjunction with an image-derived psoriatic lesion morphology (which was defined by segmenting blood vessels from a confocal microscopy image of a fluorescently labeled section of a 3 mm punch biopsy of a psoriatic lesion). The resulting predictions of the generated temperature field within the lesion were then used to assess the possibility of stalling or arresting some suspected pathogenic processes. RESULTS: According to our results, it is conceivable that perivascular nerves are thermally denatured, as almost all locations that reach 60°C were found to be within 18 µm (at 585 nm) and 11 µm (at 595 nm) of a blood vessel wall. Furthermore, activation of TRPV1 and TRPV2 channels in perivascular neuronal and immune cells is highly likely, since a critical temperature of 43°C is generated at locations within up to 350 µm of a vessel wall (at both wavelengths) and sustained for up to 700 ms (at 585 nm) and 40 ms (at 595 nm), while a critical temperature of 52°C is reached by locations within 80 µm (at 585 nm) and 30 µm (at 595 nm) of a vessel wall and sustained for up to 100 ms (at 585 nm) and 30 ms (at 595 nm). Finally, we found that the blood vessel coagulation-inducing temperature of 70°C is sustained in the vascular epithelium for up to 19 and 5 ms at 585 and 595 nm, respectively, rendering partial or total loss of vascular functionality a distinct possibility. CONCLUSIONS: The presented approach constitutes a useful tool to provide realistic estimates of the photothermal effects of PDL treatment of psoriatic plaques (as well as other selective photothermolysis-based treatments), yielding information that is essential in guiding future experimental studies toward unraveling the remedial mechanisms of these treatments.


Assuntos
Lasers de Corante , Psoríase , Humanos , Lasers de Corante/uso terapêutico , Psoríase/radioterapia , Psoríase/patologia , Psoríase/diagnóstico por imagem , Microscopia Confocal , Análise de Elementos Finitos , Modelos Biológicos
2.
Life (Basel) ; 12(2)2022 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-35207536

RESUMO

This study tests fluorescence imaging-derived quantitative parameters for perfusion evaluation of the gastric tube during surgery and correlates these parameters with patient outcomes in terms of anastomotic leakage. Poor fundus perfusion is seen as a major factor for the development of anastomotic leakage and strictures. Fluorescence perfusion imaging may reduce the incidence of complications. Parameters for the quantification of the fluorescence signal are still lacking. Quantitative parameters in terms of maximal intensity, mean slope and influx timepoint were tested for significant differences between four perfusion areas of the gastric tube in 22 patients with a repeated ANOVA test. These parameters were compared with patient outcomes. Maximal intensity, mean slope and influx timepoint were significantly different between the base of the gastric tube and the fundus (p < 0.0001). Patients who developed anastomotic leakage showed a mean slope of almost 0 in Location 4. The distance of the demarcation of ICG to the fundus was significantly higher in the three patients who developed anastomotic leakage (p < 0.0001). This study presents quantitative intra-operative perfusion imaging with fluorescence. Quantification of the fluorescence signal allows for early risk stratification of necrosis.

3.
J Biophotonics ; 13(6): e201960105, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32049426

RESUMO

The increase histopathological evaluation of prostatectomy specimens rises the workload on pathologists. Automated histopathology systems, preferably directly on unstained specimens, would accelerate the pathology workflow. In this study, we investigate the potential of quantitative analysis of optical coherence tomography (OCT) to separate benign from malignant prostate tissue automatically. Twenty fixated prostates were cut, from which 54 slices were scanned by OCT. Quantitative OCT metrics (attenuation coefficient, residue, goodness-of-fit) were compared for different tissue types, annotated on the histology slides. To avoid misclassification, the poor-quality slides, and edges of annotations were excluded. Accurate registration of OCT data with histology was achieved in 31 slices. After removing outliers, 56% of the OCT data was compared with histopathology. The quantitative data could not separate malignant from benign tissue. Logistic regression resulted in malignant detection with a sensitivity of 0.80 and a specificity of 0.34. Quantitative OCT analysis should be improved before clinical use.


Assuntos
Neoplasias da Próstata , Tomografia de Coerência Óptica , Face , Humanos , Masculino , Prostatectomia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia
4.
J Biophotonics ; 12(10): e201900037, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31245913

RESUMO

This study investigates the feasibility of in vivo quantitative optical coherence tomography (OCT) of human brain tissue during glioma resection surgery in six patients. High-resolution detection of glioma tissue may allow precise and thorough tumor resection while preserving functional brain areas, and improving overall survival. In this study, in vivo 3D OCT datasets were collected during standard surgical procedure, before and after partial resection of the tumor, both from glioma tissue and normal parenchyma. Subsequently, the attenuation coefficient was extracted from the OCT datasets using an automated and validated algorithm. The cortical measurements yield a mean attenuation coefficient of 3.8 ± 1.2 mm-1 for normal brain tissue and 3.6 ± 1.1 mm-1 for glioma tissue. The subcortical measurements yield a mean attenuation coefficient of 5.7 ± 2.1 and 4.5 ± 1.6 mm-1 for, respectively, normal brain tissue and glioma. Although the results are inconclusive with respect to trends in attenuation coefficient between normal and glioma tissue due to the small sample size, the results are in the range of previously reported values. Therefore, we conclude that the proposed method for quantitative in vivo OCT of human brain tissue is feasible during glioma resection surgery.


Assuntos
Neoplasias Encefálicas/cirurgia , Encéfalo/diagnóstico por imagem , Encéfalo/cirurgia , Glioma/cirurgia , Período Intraoperatório , Tomografia de Coerência Óptica , Neoplasias Encefálicas/diagnóstico por imagem , Estudos de Viabilidade , Glioma/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Projetos Piloto , Software
5.
J Biophotonics ; 12(4): e201800274, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30565879

RESUMO

Optical coherence tomography (OCT), enables high-resolution 3D imaging of the morphology of light scattering tissues. From the OCT signal, parameters can be extracted and related to tissue structures. One of the quantitative parameters is the attenuation coefficient; the rate at which the intensity of detected light decays in depth. To couple the quantitative parameters with the histology one-to-one registration is needed. The primary aim of this study is to validate a registration method of quantitative OCT parameters to histological tissue outcome through one-to-one registration of OCT with histology. We matched OCT images of unstained fixated prostate tissue slices with corresponding histology slides, wherein different histologic types were demarcated. Attenuation coefficients were determined by a supervised automated exponential fit (corrected for point spread function and sensitivity roll-off related signal losses) over a depth of 0.32 mm starting from 0.10 mm below the automatically detected tissue edge. Finally, the attenuation coefficients corresponding to the different tissue types of the prostate were compared. From the attenuation coefficients, we produced the squared relative residue and goodness-of-fit metric R2 . This article explains the method to perform supervised automated quantitative analysis of OCT data, and the one-to-one registration of OCT extracted quantitative data with histopathological outcomes.


Assuntos
Próstata/diagnóstico por imagem , Próstata/patologia , Prostatectomia , Tomografia de Coerência Óptica , Idoso , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Próstata/cirurgia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia
6.
J Biomed Opt ; 23(8): 1-11, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30094972

RESUMO

Diagnostic accuracy of needle-based optical coherence tomography (OCT) for prostate cancer detection by visual and quantitative analysis is defined. 106 three-dimensional (3-D)-OCT data sets were acquired in 20 prostates after radical prostatectomy and precisely matched with pathology. OCT images were grouped per histological category. Two reviewers performed blind assessments of the OCT images. Sensitivity and specificity for malignancy detection were calculated. Quantitative analyses by automated optical attenuation coefficient calculation were performed. OCT can reliably differentiate between fat, cystic, and regular atrophy and benign glands. The overall sensitivity and specificity for malignancy detection was 79% and 88% for reviewer 1 and 88% and 81% for reviewer 2. Quantitative analysis for differentiation between stroma and malignancy showed a significant difference (4.6 mm - 1 versus 5.0 mm - 1 Mann-Whitney U-test p < 0.0001). A Kruskal-Wallis test showed a significant difference in median attenuation coefficient between stroma, inflammation, Gleason 3, and Gleason 4 (4.6, 4.1, 5.9, and 5.0 mm - 1, respectively). However, attenuation coefficient varied per patient and a related-samples Wilcoxon signed-rank test showed no significant difference per patient (p = 0.17). This study confirmed the one to one correlation of histopathology and OCT. Precise matching showed that most histological tissues categories in the prostate could be distinguished by their unique pattern in OCT images. In addition, the optical attenuation coefficient can play a role in the differentiation between stroma and malignancy; however, a per patient analysis of the optical attenuation coefficient did not show a significant difference.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adulto , Humanos , Masculino , Agulhas , Estudos Prospectivos , Próstata/patologia , Neoplasias da Próstata/patologia , Sensibilidade e Especificidade
7.
Sensors (Basel) ; 18(5)2018 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-29693606

RESUMO

In this study; an OCT-based intra-operative imaging method for blood flow detection during esophagectomy with gastric tube reconstruction is investigated. Change in perfusion of the gastric tube tissue can lead to ischemia; with a high morbidity and mortality as a result. Anastomotic leakage (incidence 5⁻20%) is one of the most severe complications after esophagectomy with gastric tube reconstruction. Optical imaging techniques provide for minimal-invasive and real-time visualization tools that can be used in intraoperative settings. By implementing an optical technique for blood flow detection during surgery; perfusion can be imaged and quantified and; if needed; perfusion can be improved by either a surgical intervention or the administration of medication. The feasibility of imaging gastric microcirculation in vivo using optical coherence tomography (OCT) during surgery of patients with esophageal cancer by visualizing blood flow based on the speckle contrast from M-mode OCT images is studied. The percentage of pixels exhibiting a speckle contrast value indicative of flow was quantified to serve as an objective parameter to assess blood flow at 4 locations on the reconstructed gastric tube. Here; it was shown that OCT can be used for direct blood flow imaging during surgery and may therefore aid in improving surgical outcomes for patients.


Assuntos
Tomografia de Coerência Óptica , Neoplasias Esofágicas , Esofagectomia , Humanos , Microcirculação , Estômago
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA