1.
PLoS One ; 19(4): e0301418, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38683751

RESUMO

In the event of a widespread radiological incident, thousands of individuals will require rapid assessment of exposure using validated biodosimetry assays to inform clinical triage. In this scenario, multiple biodosimetry laboratories may be necessary for large-volume sample processing. To meet this need, we have developed a high-throughput assay for the rapid measurement of intracellular protein biomarkers in human peripheral blood samples using an Imaging Flow Cytometry (IFC) platform. The objective of this work was to harmonize and validate the reproducibility of our blood biomarker assay for radiation exposure across three IFC instruments, two located at Columbia University (CU) and the third at Health Canada. The Center for Radiological Research (CRR) at CU served as the central laboratory and reference instrument, where samples were prepared in triplicate, labeled with two radiation responsive leukocyte biomarkers (BAX and phosphor-p53 (Ser37)), and distributed for simultaneous interrogation by each IFC. Initial tests showed that significantly different baseline biomarker measurements were generated on each instrument when using the same acquisition settings, suggesting that harmonization of signal intensities is necessary. Subsequent tests harmonized biomarker measurements after irradiation by modulating laser intensity using two reference materials: unstained samples and standardized rainbow beads. Both methods generated measurements on each instrument without significant differences between the new and references instruments, allowing for the use of one master template to quantify biomarker expression across multiple instruments. Deming regression analyses of 0-5 Gy dose-response curves showed overall good correlation of BAX and p53 values across new and reference instruments. While Bland-Altman analyses indicated low to moderate instrument biases, ROC Curve analyses ultimately show successful discrimination between exposed and unexposed samples on each instrument (AUC values > 0.85).


Assuntos
Biomarcadores , Exposição à Radiação , Humanos , Exposição à Radiação/análise , Citometria de Fluxo/métodos , Reprodutibilidade dos Testes , Ensaios de Triagem em Larga Escala/métodos , Proteína Supressora de Tumor p53
3.
Cytogenet Genome Res ; 163(3-4): 110-120, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37573770

RESUMO

Following a mass-casualty nuclear/radiological event, there will be an important need for rapid and accurate estimation of absorbed dose for biological triage. The cytokinesis-block micronucleus (CBMN) assay is an established and validated cytogenetic biomarker used to assess DNA damage in irradiated peripheral blood lymphocytes. Here, we describe an intercomparison experiment between two biodosimetry laboratories, located at Columbia University (CU) and Health Canada (HC) that performed different variants of the human blood CBMN assay to reconstruct dose in human blood, with CU performing the assay on isolated lymphocytes and using semi-automated scoring whereas HC used the more conventional whole blood assay. Although the micronucleus yields varied significantly between the two assays, the predicted doses closely matched up to 4 Gy - the range from which the HC calibration curve was previously established. These results highlight the importance of a robust calibration curve(s) across a wide age range of donors that match the exposure scenario as closely as possible and that will account for differences in methodology between laboratories. We have seen that at low doses, variability in the results may be attributed to variation in the processing while at higher doses the variation is dominated by inter-individual variation in cell proliferation. This interlaboratory collaboration further highlights the usefulness of the CBMN endpoint to accurately reconstruct absorbed dose in human blood after ionizing radiation exposure.


Assuntos
Citocinese , Radiometria , Humanos , Radiometria/métodos , Triagem/métodos , Linfócitos , Testes para Micronúcleos/métodos
4.
Radiat Environ Biophys ; 62(3): 349-356, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37195317

RESUMO

Radiation dose estimations performed by automated counting of micronuclei (MN) have been studied for their utility for triage following large-scale radiological incidents; although speed is essential, it also is essential to estimate radiation doses as accurately as possible for long-term epidemiological follow-up. Our goal in this study was to evaluate and improve the performance of automated MN counting for biodosimetry using the cytokinesis-block micronucleus (CBMN) assay. We measured false detection rates and used them to improve the accuracy of dosimetry. The average false-positive rate for binucleated cells was 1.14%; average false-positive and -negative MN rates were 1.03% and 3.50%, respectively. Detection errors seemed to be correlated with radiation dose. Correction of errors by visual inspection of images used for automated counting, called the semi-automated and manual scoring method, increased accuracy of dose estimation. Our findings suggest that dose assessment of the automated MN scoring system can be improved by subsequent error correction, which could be useful for performing biodosimetry on large numbers of people rapidly, accurately, and efficiently.


Assuntos
Núcleo Celular , Radiometria , Humanos , Relação Dose-Resposta à Radiação , Radiometria/métodos , Testes para Micronúcleos/métodos , Citocinese , Linfócitos
5.
Int J Radiat Biol ; 99(9): 1320-1331, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36881459

RESUMO

BACKGROUND: Exposure to different forms of ionizing radiation occurs in diverse occupational, medical, and environmental settings. Improving the accuracy of the estimated health risks associated with exposure is therefore, essential for protecting the public, particularly as it relates to chronic low dose exposures. A key aspect to understanding health risks is precise and accurate modeling of the dose-response relationship. Toward this vision, benchmark dose (BMD) modeling may be a suitable approach for consideration in the radiation field. BMD modeling is already extensively used for chemical hazard assessments and is considered statistically preferable to identifying low and no observed adverse effects levels. BMD modeling involves fitting mathematical models to dose-response data for a relevant biological endpoint and identifying a point of departure (the BMD, or its lower bound). Recent examples in chemical toxicology show that when applied to molecular endpoints (e.g. genotoxic and transcriptional endpoints), BMDs correlate to points of departure for more apical endpoints such as phenotypic changes (e.g. adverse effects) of interest to regulatory decisions. This use of BMD modeling may be valuable to explore in the radiation field, specifically in combination with adverse outcome pathways, and may facilitate better interpretation of relevant in vivo and in vitro dose-response data. To advance this application, a workshop was organized on June 3rd, 2022, in Ottawa, Ontario that brought together BMD experts in chemical toxicology and the radiation scientific community of researchers, regulators, and policy-makers. The workshop's objective was to introduce radiation scientists to BMD modeling and its practical application using case examples from the chemical toxicity field and demonstrate the BMDExpress software using a radiation dataset. Discussions focused on the BMD approach, the importance of experimental design, regulatory applications, its use in supporting the development of adverse outcome pathways, and specific radiation-relevant examples. CONCLUSIONS: Although further deliberations are needed to advance the use of BMD modeling in the radiation field, these initial discussions and partnerships highlight some key steps to guide future undertakings related to new experimental work.


Assuntos
Benchmarking , Modelos Teóricos , Benchmarking/métodos , Dano ao DNA , Medição de Risco/métodos , Relação Dose-Resposta a Droga
6.
Front Public Health ; 10: 1002501, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36339161

RESUMO

The dicentric chromosome assay (DCA) is considered the gold standard for radiation biodosimetry, but it is limited by its long dicentric scoring time and need for skilled scorers. The automation of scoring dicentrics has been considered a strategy to overcome the constraints of DCA. However, the studies on automated scoring methods are limited compared to those on conventional manual DCA. Our study aims to assess the performance of a semi-automated scoring method for DCA using ex vivo and in vivo irradiated samples. Dose estimations of 39 blind samples irradiated ex vivo and 35 industrial radiographers occupationally exposed in vivo were estimated using the manual and semi-automated scoring methods and subsequently compared. The semi-automated scoring method, which removed the false positives of automated scoring using the dicentric chromosome (DC) scoring algorithm, had an accuracy of 94.9% in the ex vivo irradiated samples. It also had more than 90% accuracy, sensitivity, and specificity to distinguish binary dose categories reflecting clinical, diagnostic, and epidemiological significance. These data were comparable to those of manual DCA. Moreover, Cohen's kappa statistic and McNemar's test showed a substantial agreement between the two methods for categorizing in vivo samples into never and ever radiation exposure. There was also a significant correlation between the two methods. Despite of comparable results with two methods, lower sensitivity of semi-automated scoring method could be limited to assess various radiation exposures. Taken together, our findings show the semi-automated scoring method can provide accurate dose estimation rapidly, and can be useful as an alternative to manual DCA for biodosimetry in large-scale accidents or cases to monitor radiation exposure of radiation workers.


Assuntos
Exposição à Radiação , Triagem , Humanos , Relação Dose-Resposta à Radiação , Doses de Radiação , Cromossomos Humanos , Aberrações Cromossômicas
7.
Int J Radiat Biol ; 98(12): 1832-1844, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35939275

RESUMO

PURPOSE: Benchmark dose (BMD) modeling is a method commonly used in chemical toxicology to identify the point of departure (POD) from a dose-response curve linked to a health-related outcome. Recently, its application in the analysis of transcriptional data for quantitative adverse outcome pathway (AOP) development is being explored. As AOPs are informed by diverse data types, it is important to understand the impact of study parameters such as dose selection, the number of replicates and dose range on BMD outputs for radiation-induced genes and pathways. MATERIALS AND METHODS: Data were selected from the Gene Expression Omnibus (GSE52403) that featured gene expression profiles of peripheral blood samples from C57BL/6 mice 6 hours post-exposure to 137Cs gamma-radiation at 0, 1, 2, 3, 4.5, 6, 8 and 10.5 Gy. The dataset comprised a broad dose range over multiple dose points with consistent dose spacing and multiple biological replicates. This dataset was ideal for systematically transforming across three categories: (1) dose range, (2) dose-spacing and (3) number of controls/replicates. Across these categories, 29 transformed datasets were compared to the original dataset to determine the impact of each transformation on the BMD outputs. RESULTS: Most of the experimental changes did not impact the BMD outputs. The transformed datasets were largely consistent with the original dataset in terms of the number of reproduced genes modeled and absolute BMD values for genes and pathways. Variations in dose selection identified the importance of the absolute value of the lowest and second dose. It was determined that dose selection should include at least two doses <1 Gy and two >5 Gy to achieve meaningful BMD outputs. Changes to the number of biological replicates in the control and non-zero dose groups impacted the overall accuracy and precision of the BMD outputs as well as the ability to fit dose-response models consistent with the original dataset. CONCLUSION: Successful application of transcriptomic BMD modeling for radiation datasets requires considerations of the exposure dose and the number of biological replicates. Most important is the selection of the lowest doses and dose spacing. Reflections on these parameters in experimental design will provide meaningful BMD outputs that could correlate well to apical endpoints of relevance to radiation exposure assessment.


Assuntos
Benchmarking , Projetos de Pesquisa , Camundongos , Animais , Relação Dose-Resposta a Droga , Medição de Risco/métodos , Camundongos Endogâmicos C57BL
9.
Int J Radiat Biol ; 97(11): 1516-1525, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34402738

RESUMO

BACKGROUND: The circulatory system distributes nutrients, signaling molecules, and immune cells to vital organs and soft tissues. Epidemiological, animal, and in vitro cellular mechanistic studies have highlighted that exposure to ionizing radiation (IR) can induce molecular changes in cellular and subcellular milieus leading to long-term health impacts, particularly on the circulatory system. Although the mechanisms for the pathologies are not fully elucidated, endothelial dysfunction is proven to be a critical event via radiation-induced oxidative stress mediators. To delineate connectivities of events specifically to cardiovascular disease (CVD) initiation and progression, the adverse outcome pathway (AOP) approach was used with consultation from field experts. AOPs are a means to organize information around a disease of interest to a regulatory question. An AOP begins with a molecular initiating event and ends in an adverse outcome via sequential linkages of key event relationships that are supported by evidence in the form of the modified Bradford-Hill criteria. Detailed guidelines on building AOPs are provided by the Organisation for Economic Cooperation and Development (OECD) AOP program. Here, we report on the questions and discussions needed to develop an AOP for CVD resulting from IR exposure. A recent workshop jointly organized by the MELODI (Multidisciplinary European Low Dose Initiative) and the ALLIANCE (European Radioecology Alliance) associations brought together experts from the OECD to present the AOP approach and tools with examples from the toxicology field. As part of this workshop, four working groups were formed to discuss the identification of adverse outcomes relevant to radiation exposures and development of potential AOPs, one of which was focused on IR-induced cardiovascular effects. Each working group comprised subject matter experts and radiation researchers interested in the specific disease area and included an AOP coach. CONCLUSION: The CVD working group identified the critical questions of interest for AOP development, including the exposure scenario that would inform the evidence, the mechanisms of toxicity, the initiating event, intermediate key events/relationships, and the type of data currently available. This commentary describes the four-day discussion of the CVD working group, its outcomes, and demonstrates how collaboration and expert consultation is vital to informing AOP construction.


Assuntos
Rotas de Resultados Adversos , Doenças Cardiovasculares , Sistema Cardiovascular , Animais , Doenças Cardiovasculares/etiologia , Radiação Ionizante , Encaminhamento e Consulta , Medição de Risco
10.
Int J Radiat Biol ; 97(1): 85-101, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32909875

RESUMO

PURPOSE: Adverse outcome pathways (AOPs) provide a modular framework for describing sequences of biological key events (KEs) and key event relationships (KERs) across levels of biological organization. Empirical evidence across KERs can support construction of quantified AOPs (qAOPs). Using an example AOP of energy deposition from ionizing radiation onto DNA leading to lung cancer incidence, we investigate the feasibility of quantifying data from KERs supported by all types of stressors. The merits and challenges of this process in the context of AOP construction are discussed. MATERIALS AND METHODS: Empirical evidence across studies of dose-response from four KERs of the AOP were compiled independently for quantification. Three upstream KERs comprised of evidence from various radiation types in line with AOP guidelines. For these three KERs, a focused analysis of data from alpha-particle studies was undertaken to better characterize the process to the adverse outcome (AO) for a radon gas stressor. Numerical information was extracted from tables and graphs to plot and tabulate the response of KEs. To complement areas of the AOP quantification process, Monte Carlo (MC) simulations in TOPAS-nBio were performed to model exposure conditions relevant to the AO for an example bronchial compartment of the lung with secretory cell nuclei targets. RESULTS: Quantification of AOP KERs highlighted the relevance of radiation types under the stressor-agnostic intent of AOP design, motivating a focus on specific types. For a given type, significant differences of KE response indicate meaningful data to derive linkages from the MIE to the AO is lacking and that better response-response focused studies are required. The MC study estimates the linear energy transfer (LET) of alpha-particles emitted by radon-222 and its progeny in the secretory cell nuclei of the example lung compartment to range from 94-5+5 to 192-18+15 keV/µm. CONCLUSION: Quantifying AOP components provides a means to assemble empirical evidence across different studies. This highlights challenges in the context of studies examining similar endpoints using different radiation types. Data linking KERs to a MIE of 'deposition of energy' is shown to be non-compatible with the stressor-agnostic principles of AOP design. Limiting data to that describing response-response relationships between adjacent KERs may better delineate studies relevant to the damage that drives a pathway to the next KE and still support an 'all hazards' approach. Such data remains limited and future investigations in the radiation field may consider this approach when designing experiments and reporting their results and outcomes.


Assuntos
Rotas de Resultados Adversos , Neoplasias Pulmonares/etiologia , Neoplasias Induzidas por Radiação/etiologia , Partículas alfa , Humanos , Transferência Linear de Energia , Método de Monte Carlo
11.
Int J Radiat Biol ; 96(11): 1492-1503, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32910711

RESUMO

PURPOSE: Inhomogeneous exposures to ionizing radiation can be detected and quantified with the dicentric chromosome assay (DCA) of metaphase cells. Complete automation of interpretation of the DCA for whole-body irradiation has significantly improved throughput without compromising accuracy, however, low levels of residual false positive dicentric chromosomes (DCs) have confounded its application for partial-body exposure determination. MATERIALS AND METHODS: We describe a method of estimating and correcting for false positive DCs in digitally processed images of metaphase cells. Nearly all DCs detected in unirradiated calibration samples are introduced by digital image processing. DC frequencies of irradiated calibration samples and those exposed to unknown radiation levels are corrected subtracting this false positive fraction from each. In partial-body exposures, the fraction of cells exposed, and radiation dose can be quantified after applying this modification of the contaminated Poisson method. RESULTS: Dose estimates of three partially irradiated samples diverged 0.2-2.5 Gy from physical doses and irradiated cell fractions deviated by 2.3%-15.8% from the known levels. Synthetic partial-body samples comprised of unirradiated and 3 Gy samples from 4 laboratories were correctly discriminated as inhomogeneous by multiple criteria. Root mean squared errors of these dose estimates ranged from 0.52 to 1.14 Gy2 and from 8.1 to 33.3%2 for the fraction of cells irradiated. CONCLUSIONS: Automated DCA can differentiate whole- from partial-body radiation exposures and provides timely quantification of estimated whole-body equivalent dose.


Assuntos
Análise Citogenética , Exposição à Radiação/análise , Radiometria/métodos , Automação , Humanos , Distribuição de Poisson
12.
J Radiat Res ; 60(5): 555-563, 2019 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-31165147

RESUMO

The dicentric chromosome assay (DCA) is a well-established biodosimetry test to estimate exposure to ionizing radiation. The Korea Institute of Radiological and Medical Sciences (KIRAMS) established a DCA protocol as a medical response to radiation emergencies in South Korea. To maintain its accuracy and performance, intercomparison exercises with Health Canada (HC) have been conducted; herein, we aimed to validate our capacity of DCA analysis based on those results. Blood samples irradiated at HC were shipped to KIRAMS to assess the irradiation dose to blinded samples using conventional DCA full scoring and triage-based techniques (conventional DCA scoring in triage mode and DCA QuickScan method). Actual doses fell within the 95% confidence intervals of dose estimates for 70-100% of the blinded samples in 2015-2018. All methods discriminated binary dose categories, reflecting clinical significance. This DCA can be used as a reliable radiation biodosimetry tool in preparation for radiation accidents in South Korea.


Assuntos
Bioensaio/métodos , Cromossomos Humanos/efeitos da radiação , Doses de Radiação , Relação Dose-Resposta à Radiação , Humanos , República da Coreia , Sensibilidade e Especificidade
13.
Radiat Res ; 191(4): 342-351, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30779694

RESUMO

The cytokinesis-block micronucleus (CBMN) assay has become a fully-validated and standardized method for radiation biodosimetry. The assay is typically performed using microscopy, which is labor intensive, time consuming and impractical after a large-scale radiological/nuclear event. Imaging flow cytometry (IFC), which combines the statistical power of traditional flow cytometry with the sensitivity and specificity of microscopy, has been recently used to perform the CBMN assay. Since this technology is capable of automated sample acquisition and multi-file analysis, we have integrated IFC into our Rapid Automated Biodosimetry Technology (RABiT-II). Assay development and optimization studies were designed to increase the yield of binucleated cells (BNCs), and improve data acquisition and analysis templates to increase the speed and accuracy of image analysis. Human peripheral blood samples were exposed ex vivo with up to 4 Gy of c rays at a dose rate of 0.73 Gy/min. After irradiation, samples were transferred to microtubes (total volume of 1 ml including blood and media) and organized into a standard 8 × 12 plate format. Sample processing methods were modified by increasing the blood-to-media ratio, adding hypotonic solution prior to cell fixation and optimizing nuclear DRAQ5 staining, leading to an increase of 81% in BNC yield. Modification of the imaging processing algorithms within IFC software also improved BNC and MN identification, and reduced the average time of image analysis by 78%. Finally, 50 ll of irradiated whole blood was cultured with 200 ll of media in 96-well plates. All sample processing steps were performed automatically using the RABiT-II cell: :explorer robotic system adopting the optimized IFC-CBMN assay protocol. The results presented here detail a novel, high-throughput RABiT-IFC CBMN assay that possesses the potential to increase capacity for triage biodosimetry during a large-scale radiological/nuclear event.


Assuntos
Citocinese/efeitos da radiação , Citometria de Fluxo , Testes para Micronúcleos , Radiometria/métodos , Robótica , Triagem , Adulto , Automação , Calibragem , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
14.
Radiat Prot Dosimetry ; 186(1): 42-47, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-30624749

RESUMO

Accuracy of the automated dicentric chromosome (DC) assay relies on metaphase image selection. This study validates a software framework to find the best image selection models that mitigate inter-sample variability. Evaluation methods to determine model quality include the Poisson goodness-of-fit of DC distributions for each sample, residuals after calibration curve fitting and leave-one-out dose estimation errors. The process iteratively searches a pool of selection model candidates by modifying statistical and filter cut-offs to rank the best candidates according to their respective evaluation scores. Evaluation scores minimize the sum of squared errors relative to the actual radiation dose of the calibration samples. For one laboratory, the minimum score for the curve fit residual method was 0.0475 Gy2, compared to 1.1975 Gy2 without image selection. Application of optimal selection models using samples of unknown exposure produced estimated doses within 0.5 Gy of physical dose. Model optimization standardizes image selection among samples and provides relief from manual DC scoring, improving accuracy and consistency of dose estimation.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas , Cromossomos Humanos/efeitos da radiação , Análise Citogenética/métodos , Laboratórios/normas , Metáfase/genética , Radiometria/normas , Automação , Humanos , Metáfase/efeitos da radiação , Microscopia/métodos , Doses de Radiação
15.
Int J Radiat Biol ; 95(2): 107-119, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30496029

RESUMO

PURPOSE: Routine dental X-rays are among the most common sources of ionizing radiation exposure for healthy individuals globally, with 300 examinations/1000 individuals/year as documented by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) global survey of medical radiation usage and exposure. Furthermore, in the United States of America, an increased use of dental radiography is evident. However, with the shift from using film to digital image receptors, the dose of radiation per routine examination has decreased. Despite this, there remains public concern of dental X-rays. This continuing concern highlights the need to review the literature on biological and health effects related to exposure, from dental X-rays. MATERIAL AND METHODS: This report presents studies investigating biological and health effects related to exposures using dental X-rays in patients and provides a critical evaluation. Relevant studies specific to dental X-rays are reviewed from 1970 and onward with the bulk data in this field resulting from epidemiological and biomonitoring studies. RESULTS: While, most epidemiological studies suggest a possible correlation between head/neck related tumors and exposure to dental X-rays, evidence for causation is lacking. Biomonitoring studies suggest that exposure to low-level radiation such as that of dental radiography may not be a factor in inducing long-term chromosomal damage, but may result in localized cytotoxicity in the irradiated region of the mouth, with no long-term harm. CONCLUSIONS: In general, the total number of studies is low and the majority of the data has been generated from poorly designed experiments. This review will highlight shortcomings that could influence outcomes and provide a more balanced interpretation that could impact the public perception and the level of public concern on the health effects resulting from dental X-rays.


Assuntos
Radiografia Dentária/efeitos adversos , Tomografia Computadorizada de Feixe Cônico , Humanos , Testes para Micronúcleos , Doses de Radiação , Raios X
16.
Radiat Res ; 188(1): 1-20, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28489488

RESUMO

A workshop entitled "Radiation-Induced Fibrosis: Mechanisms and Opportunities to Mitigate" (held in Rockville, MD, September 19, 2016) was organized by the Radiation Research Program and Radiation Oncology Branch of the Center for Cancer Research (CCR) of the National Cancer Institute (NCI), to identify critical research areas and directions that will advance the understanding of radiation-induced fibrosis (RIF) and accelerate the development of strategies to mitigate or treat it. Experts in radiation biology, radiation oncology and related fields met to identify and prioritize the key areas for future research and clinical translation. The consensus was that several known and newly identified targets can prevent or mitigate RIF in pre-clinical models. Further, basic and translational research and focused clinical trials are needed to identify optimal agents and strategies for therapeutic use. It was felt that optimally designed preclinical models are needed to better study biomarkers that predict for development of RIF, as well as to understand when effective therapies need to be initiated in relationship to manifestation of injury. Integrating appropriate endpoints and defining efficacy in clinical trials testing treatment of RIF were felt to be critical to demonstrating efficacy. The objective of this meeting report is to (a) highlight the significance of RIF in a global context, (b) summarize recent advances in our understanding of mechanisms of RIF,


Assuntos
Fibrose Pulmonar/diagnóstico , Fibrose Pulmonar/terapia , Pneumonite por Radiação/diagnóstico , Pneumonite por Radiação/terapia , Radioterapia/efeitos adversos , Medicina Baseada em Evidências , Humanos , National Cancer Institute (U.S.) , Fibrose Pulmonar/etiologia , Pneumonite por Radiação/etiologia , Resultado do Tratamento , Estados Unidos
17.
Methods ; 112: 18-24, 2017 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-27524557

RESUMO

Biodosimetry is an important tool for triage in the case of large-scale radiological or nuclear emergencies, but traditional microscope-based methods can be tedious and prone to scorer fatigue. While the dicentric chromosome assay (DCA) has been adapted for use in triage situations, it is still time-consuming to create and score slides. Recent adaptations of traditional biodosimetry assays to imaging flow cytometry (IFC) methods have dramatically increased throughput. Additionally, recent improvements in image analysis algorithms in the IFC software have resulted in improved specificity for spot counting of small events. In the IFC method for the dicentric chromosome analysis (FDCA), lymphocytes isolated from whole blood samples are cultured with PHA and Colcemid. After incubation, lymphocytes are treated with a hypotonic solution and chromosomes are isolated in suspension, labelled with a centromere marker and stained for DNA content with DRAQ5. Stained individual chromosomes are analyzed on the ImageStream®X (EMD-Millipore, Billerica, MA) and mono- and dicentric chromosome populations are identified and enumerated using advanced image processing techniques. Both the preparation of the isolated chromosome suspensions as well as the image analysis methods were fine-tuned in order to optimize the FDCA. In this paper we describe the method to identify and score centromeres in individual chromosomes by IFC and show that the FDCA method may further improve throughput for triage biodosimetry in the case of large-scale radiological or nuclear emergencies.


Assuntos
Aberrações Cromossômicas/efeitos da radiação , Cromossomos Humanos/efeitos da radiação , Citometria por Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Exposição à Radiação/análise , Radiometria/métodos , Antraquinonas/química , Centrômero/efeitos dos fármacos , Centrômero/efeitos da radiação , Centrômero/ultraestrutura , Aberrações Cromossômicas/efeitos dos fármacos , Cromossomos Humanos/efeitos dos fármacos , Cromossomos Humanos/ultraestrutura , Demecolcina/farmacologia , Relação Dose-Resposta à Radiação , Humanos , Citometria por Imagem/instrumentação , Linfócitos/efeitos dos fármacos , Linfócitos/efeitos da radiação , Fito-Hemaglutininas/farmacologia , Coloração e Rotulagem/métodos
18.
Environ Mol Mutagen ; 57(8): 589-604, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27601323

RESUMO

Recent advances in "-omics" technologies have simplified capacity to concurrently assess expression profiles of thousands of targets in a cellular system. However, compilation and analysis of "omics" data in support of human health protection remains a challenge. Benchmark dose (BMD) modeling is currently being employed in chemical risk assessment to estimate acceptable levels of exposure. Although typically applied to conventional endpoints, newer software has enabled this application to be extended to transcriptomic datasets. BMD analytical tools now have the capacity to model transcriptional dose-response data to derive meaningful BMD values for genes, pathways and gene ontologies. In this report, radiation data obtained from the Gene Expression Omnibus (GEO) were analyzed to generate BMD values for transcriptional responses. The datasets comprised microarray analyses of human blood gamma-irradiated ex vivo (0-20 Gy) and human-derived cell lines exposed to alpha particle radiation (0.5-1.5 Gy). The distributions of BMDs for statistically significant genes and pathways in response to radiation exposure were examined and compared across studies. BMD modeling could identify pathway/gene sensitivities across wide radiation dose ranges, experimental conditions (time-points, cell types) and radiation qualities. BMD analysis offered a new approach to examine transcriptional data. The results were shown to provide information on transcriptional thresholds of effects to support refined risk assessments for low dose ionizing radiation exposures, derive gene-based values for relative biological effectiveness and identify pathways involved in radiation sensitivities across cell types which may extend to applications a clinical setting. Environ. Mol. Mutagen. 57:589-604, 2016. © 2016 Wiley Periodicals, Inc.


Assuntos
Partículas alfa , Modelos Biológicos , Medição de Risco/métodos , Transcrição Gênica/efeitos da radiação , Benchmarking , Linhagem Celular , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino
19.
Radiat Prot Dosimetry ; 172(1-3): 207-217, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27412514

RESUMO

The dose from ionizing radiation exposure can be interpolated from a calibration curve fit to the frequency of dicentric chromosomes (DCs) at multiple doses. As DC counts are manually determined, there is an acute need for accurate, fully automated biodosimetry calibration curve generation and analysis of exposed samples. Software, the Automated Dicentric Chromosome Identifier (ADCI), is presented which detects and discriminates DCs from monocentric chromosomes, computes biodosimetry calibration curves and estimates radiation dose. Images of metaphase cells from samples, exposed at 1.4-3.4 Gy, that had been manually scored by two reference laboratories were reanalyzed with ADCI. This resulted in estimated exposures within 0.4-1.1 Gy of the physical dose. Therefore, ADCI can determine radiation dose with accuracies comparable to standard triage biodosimetry. Calibration curves were generated from metaphase images in ~10 h, and dose estimations required ~0.8 h per 500 image sample. Running multiple instances of ADCI may be an effective response to a mass casualty radiation event.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Interpretação de Imagem Assistida por Computador/métodos , Radiometria/métodos , Robótica/métodos , Software , Interface Usuário-Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Humanos , Reconhecimento Automatizado de Padrão/métodos , Doses de Radiação , Manejo de Espécimes/métodos
20.
Health Phys ; 110(1): 29-36, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26606062

RESUMO

The cytokinesis-block micronucleus assay can be employed in triage radiation biodosimetry to determine the dose of radiation to an exposed individual by quantifying the frequency of micronuclei in binucleated lymphocyte cells. Partially automated analysis of the assay has been applied to traditional microscope-based methods, and most recently, the assay has been adapted to an automated imaging flow cytometry method. This method is able to automatically score a larger number of binucleated cells than are typically scored by microscopy. Whole blood samples were irradiated, divided into 2 mL and 200 µL aliquots, cultured for 48 h and 72 h, and processed to generate calibration curves from 0-4 Gy. To validate the method for use in radiation biodosimetry, nine separate whole blood samples were then irradiated to known doses, blinded, and processed. Results indicate that dose estimations can be determined to within ±0.5 Gy of the delivered dose after only 48 h of culture time with an initial blood volume of 200 µL. By performing the cytokinesis-block micronucleus assay using imaging flow cytometry, a significant reduction in the culture time and volume requirements is possible, which greatly increases the applicability of the assay in high throughput triage radiation biodosimetry.


Assuntos
Citocinese/efeitos da radiação , Citometria por Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Leucócitos Mononucleares/efeitos da radiação , Testes para Micronúcleos/métodos , Radiometria/métodos , Adulto , Citocinese/fisiologia , Relação Dose-Resposta à Radiação , Feminino , Humanos , Leucócitos Mononucleares/citologia , Leucócitos Mononucleares/metabolismo , Masculino , Pessoa de Meia-Idade