Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Front Neurol ; 13: 894119, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35775045

RESUMO

Introduction: Neurofilament light (NfL) can be detected in blood of healthy individuals and at elevated levels in those with different neurological diseases. We investigated if the choice of biological matrix can affect results when using NfL as biomarker in epidemiological studies. Method: We obtained paired serum and EDTA-plasma samples of 299 individuals aged 37-67 years (BiDirect study) and serum samples of 373 individuals aged 65-83 years (MEMO study). In BiDirect, Passing-Bablok analyses were performed to assess proportional and systematic differences between biological matrices. Associations between serum or EDTA-plasma NfL and renal function (serum creatinine, serum cystatin C, glomerular filtration rate, and kidney disease) were investigated using linear or logistic regression, respectively. All regression coefficients were estimated (1) per one ng/L increase and (2) per one standard deviation increase (standardization using z-scores). In MEMO, regression coefficients were estimated (1) per one ng/L increase of serum or calculated EDTA-plasma NfL and (2) per one standard deviation increase providing a comparison to the results from BiDirect. Results: We found proportional and systematic differences between paired NfL measurements in BiDirect, i.e., serum NfL [ng/L] = -0.33 [ng/L] + 1.11 × EDTA-plasma NfL [ng/L]. Linear regression coefficients for the associations between NfL and renal function did not vary between the different NfL measurements. In MEMO, one standard deviation increase in serum NfL was associated with greater changes in the outcomes than in BiDirect. Conclusion: Although there are differences between serum and EDTA-plasma NfL, results can be used interchangeably if standardized values are used.

2.
J Alzheimers Dis ; 83(3): 1367-1377, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34420976

RESUMO

BACKGROUND: An N-terminal octapeptide cleavage of the cystatin C protein was discovered by mass spectrometry when cerebrospinal fluid (CSF) was stored at -20°C for 3 months, which did not occur when CSF was stored at -80°C. OBJECTIVE: The aim was to develop an immunoassay as quality assessment tool to detect this -20°C cleavage of cystatin C in CSF and support Alzheimer's disease research. METHODS: A specific monoclonal antibody and a double indirect sandwich ELISA were developed: one assay quantifies the octapeptide uncleaved protein specifically and the other quantifies the total cystatin C present in the biological fluid (both cleaved and uncleaved forms). The ratio of these concentrations was calculated to assess the extent of cleavage of cystatin C. The novel ELISA was validated and applied in a short-term (up to 4 weeks) and mid-term (up to one year) stability study of CSF stored at 4°C, -20°C, -80°C, and liquid nitrogen. Impact of freeze-thaw cycles, adsorption, and protease inhibitors were tested. RESULTS: The ratio of truncated protein was modified following -20°C storage and seemed to reach a plateau after 6 months. The ratio was impacted neither by freeze-thaw cycles nor adsorption. The -20°C specific cleavage was found to be protease related. CONCLUSION: Using this novel double indirect sandwich ELISA, absolute levels of the total and uncleaved cystatin C and the ratio of truncated cystatin C can be measured. This assay is an easily applicable tool which can be used to confirm that CSF biospecimen are fit-for-purpose for Alzheimer's disease research.


Assuntos
Doença de Alzheimer/líquido cefalorraquidiano , Biomarcadores/líquido cefalorraquidiano , Cistatina C/efeitos adversos , Ensaio de Imunoadsorção Enzimática/normas , Projetos de Pesquisa/normas , Manejo de Espécimes/normas , Humanos , Espectrometria de Massas , Inibidores de Proteases , Estabilidade Proteica
3.
Front Aging Neurosci ; 13: 638718, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33762924

RESUMO

Background: The role of cerebrospinal fluid (CSF) alpha-synuclein as a potential biomarker has been challenged mainly due to variable preanalytical measures between laboratories. To evaluate the impact of the preanalytical factors contributing to such variability, the different subforms of alpha-synuclein need to be studied individually. Method: We investigated the effect of exposing CSF samples to several preanalytical sources of variability: (1) different polypropylene (PP) storage tubes; (2) use of non-ionic detergents; (3) multiple tube transfers; (4) multiple freeze-thaw cycles; and (5) delayed storage. CSF oligomeric- and total-alpha-synuclein levels were estimated using our in-house sandwich-based enzyme-linked immunosorbent assays. Results: Siliconized tubes provided the optimal preservation of CSF alpha-synuclein proteins among other tested polypropylene tubes. The use of tween-20 detergent significantly improved the recovery of oligomeric-alpha-synuclein, while multiple freeze-thaw cycles significantly lowered oligomeric-alpha-synuclein in CSF. Interestingly, oligomeric-alpha-synuclein levels remained relatively stable over multiple tube transfers and upon delayed storage. Conclusion: Our study showed for the first-time distinct impact of preanalytical factors on the different forms of CSF alpha-synuclein. These findings highlight the need for special considerations for the different forms of alpha-synuclein during CSF samples' collection and processing.

4.
Clin Chim Acta ; 497: 204-211, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31348908

RESUMO

Stability of the cerebrospinal fluid (CSF) composition under different pre-analytical conditions is relevant for the diagnostic potential of biomarkers. Our aim was to examine the pre-analytical stability of promising CSF biomarkers that are currently evaluated for their discriminative use in various neurological diseases. Pooled CSF was aliquoted and experimentally exposed to delayed storage: 0, 1, 2, 4, 24, 72, or 168 h at 4 °C or room temperature (RT), or 1-4 months at -20 °C; or up to 7 freeze/thaw (f/t) cycles, before final storage at -80 °C. Eleven CSF biomarkers were screened using immunoassays, liquid chromatography, or enzymatic methods. Levels of neurogranin (truncP75), chitinase-3-like protein (YKL-40), beta-site amyloid precursor protein cleaving enzyme 1 (BACE1), acetylcholinesterase (AChE) enzymatic activity, theobromine, secreted protein acidic and rich in cysteine-like 1 (SPARCL-1) and homovanillic acid (HVA) levels were not affected by the applied storage conditions. 3-Methoxy-4-hydroxyphenylglycol (MHPG) levels linearly and strongly decreased after 4 h at RT (-10%) or 24 h at 4 °C (-27%), and with 6% after every f/t cycle. 5-Methyltetrahydrofolate (5-MTHF) (-29% after 1 week at RT) and 5-hydroxyindoleacetic acid levels (5-HIAA) (-16% after 1 week at RT) were reduced and 3,4-dihydroxyphenylacetic acid (DOPAC) levels (+22% after 1 week at RT) increased, but only after >24 h at RT. Ten out of eleven potential CSF novel biomarkers showed very limited change under common storage and f/t conditions, suggesting that these CSF biomarkers can be trustfully tested under the pre-analytical conditions present across different cohorts.


Assuntos
Biomarcadores/líquido cefalorraquidiano , Biomarcadores/metabolismo , Doenças do Sistema Nervoso/diagnóstico , Biomarcadores/química , Ensaio de Imunoadsorção Enzimática , Humanos , Doenças do Sistema Nervoso/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA