Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eye (Lond) ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38745084

RESUMO

BACKGROUND: Silicone oil (SO) is a long-term tamponade for repair of complex retinal pathology but has limitations including late redetachment. This study describes our experience with SO tamponade for repair of retinal detachment with proliferative vitreoretinopathy (PVR), with attention to anatomic and functional outcomes. METHODS: Retrospective consecutive case series of eyes with retinal detachment (RD) complicated by proliferative vitreoretinopathy (PVR) receiving SO tamponade at the University of Wisconsin between 2013 and 2019. Group 1 defined as primary SO placement; Group 2 had SO placed after failing prior retinal detachment repair. RESULTS: Inclusion criteria of SO placement for repair of RD with PVR was met for 117 eyes. The final reattachment rate was 84% for all eyes, with no difference between Groups 1 and 2. Vision improvement was 2.1 lines for Group 1 (p = 0.06 from baseline) and 4.6 lines for Group 2 (p < 0.0001). The mean number of silicone oil placements was 1.4. Less improvement in vision was noted with repeat SO placement, though overall functional vision of 5/200 or better was achieved in 63.2% of patients. CONCLUSIONS: SO tamponade allows long-term anatomical stabilisation and substantial vision recovery in eyes with retinal detachment complicated by PVR. Rates of anatomic and functional success have improved significantly when compared to prior studies using oil tamponade for repair of PVR.

2.
J Vitreoretin Dis ; 7(5): 371-375, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37706091

RESUMO

Purpose: To determine the safety and efficacy of fellow-eye laser prophylaxis (FELP) in reducing the rate of retinal detachment (RD) in patients undergoing repair of a primary RD. Methods: Retrospective data were collected on the fellow eyes of consecutive patients undergoing primary RD repair. Patients lacking peripheral retinal pathology in the fellow eye or with less than 3 years of follow-up were excluded. Ninety-eight consecutive patients were identified who underwent FELP as compared with 28 who did not. No patient had symptoms in their fellow eye upon presentation. Rates of RD and epiretinal membrane (ERM) formation in the treatment group were compared with the control group. Results: Three of 98 (3.1%) patients developed RD despite having FELP compared with 5 of 28 (17.9%) in the control group (P = .005). In the FELP group, 16 (16.3%) patients developed ERM vs 7 of 28 (25.0%) in the group that did not receive prophylactic laser (P = .29). No patients in either the FELP or control group required surgery for ERM. Conclusions: Prophylactic laser to the fellow eye of patients undergoing primary RD repair reduced the risk of RD without significant risk of ERM formation.

3.
Telemed J E Health ; 29(8): 1171-1178, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36576981

RESUMO

Abstract Background: Follow-up adherence with in-person care is critical for achieving improved clinical outcomes in telemedicine screening programs. We sought to quantify the impact of the COVID-19 pandemic upon follow-up adherence and factors associated with follow-up adherence after teleophthalmology for diabetic eye screening. Methods: We retrospectively reviewed medical records of adults screened in a clinical teleophthalmology program at urban and rural primary care clinics between May 2015 and December 2020. We defined follow-up adherence as medical record documentation of an in-person eye exam within 1 year among patients referred for further care. Regression models were used to identify factors associated with follow-up adherence. Results: Among 948 patients, 925 (97.6%) had health insurance and 170 (17.9%) were referred for follow-up. Follow-up adherence declined from 62.7% (n = 52) prepandemic to 46.0% (n = 40) during the pandemic (p = 0.04). There was a significant decline in follow-up adherence among patients from rural (p < 0.001), but not urban (p = 0.72) primary care clinics. Higher median household income (odds ratio [OR] 1.68, 95% confidence interval [CI]: 1.19-2.36) and obtaining care from an urban clinic (OR 5.29, 95% CI: 2.09-13.43) were associated with greater likelihood of follow-up during the pandemic. Discussion: Follow-up adherence remains limited after teleophthalmology screening even in a highly insured patient population, with a further decline observed during the COVID-19 pandemic. Our results suggest that rural patients and those with lower socioeconomic status experienced greater barriers to follow-up eye care during the COVID-19 pandemic. Conclusions: Addressing barriers to in-person follow-up care is needed to effectively improve clinical outcomes after teleophthalmology screening.


Assuntos
COVID-19 , Diabetes Mellitus , Retinopatia Diabética , Oftalmologia , Telemedicina , Adulto , Humanos , Telemedicina/métodos , Pandemias , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/epidemiologia , Oftalmologia/métodos , Estudos Retrospectivos , Seguimentos , Programas de Rastreamento/métodos , COVID-19/epidemiologia , Diabetes Mellitus/epidemiologia
4.
Ophthalmic Plast Reconstr Surg ; 38(6): 551-557, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35551414

RESUMO

PURPOSE: To identify risk factors for the development of new-onset, postoperative diplopia following orbital decompression surgery based on patient demographics, clinical exam characteristics, radiographic parameters, and surgical techniques. METHODS: We conducted a multi-center retrospective chart review of patients who underwent orbital decompression for thyroid eye disease (TED). Patient demographics, including age, gender, smoking history, preoperative exophthalmometry, clinical activity score (CAS), use of peribulbar and/or systemic steroids, and type of orbital decompression were reviewed. Postoperative diplopia was determined at a minimum of 3 months postoperatively and before any further surgeries. Cross-sectional area ratios of each extraocular muscle to orbit and total fat to orbit were calculated from coronal imaging in a standard fashion. All measurements were carried out using PACS imaging software. Multivariable logistic regression modeling was performed using Stata 14.2 (StataCorp, College Station, TX). RESULTS: A total of 331 patients without preoperative diplopia were identified. At 3 months postoperatively, 249 patients had no diplopia whereas 82 patients developed diplopia. The average postoperative follow-up was 22 months (range 3-156) months. Significant preoperative clinical risk factors for postoperative diplopia included older age at surgery, proptosis, use of peribulbar or systemic steroids, elevated clinical activity score, and presence of preoperative compressive optic neuropathy. Imaging findings of enlarged cross-sectional areas of each rectus muscle to the overall orbital area also conferred a significant risk of postoperative diplopia. Regarding surgical factors, postoperative diplopia was more common among those undergoing medial wall decompression, bilateral orbital surgery, and balanced decompression, whereas endoscopic medial wall decompression was found to be relatively protective. CONCLUSIONS: This study identifies risk factors associated with the development of diplopia following orbital decompression using multivariable data. This study demonstrates that several characteristics including age, clinical activity score, the cross-sectional muscle to orbit ratios, in addition to the type of orbital decompression surgery, are predictive factors for the development of new-onset postoperative diplopia.


Assuntos
Oftalmopatia de Graves , Humanos , Oftalmopatia de Graves/diagnóstico , Oftalmopatia de Graves/cirurgia , Oftalmopatia de Graves/complicações , Estudos Retrospectivos , Descompressão Cirúrgica/efeitos adversos , Descompressão Cirúrgica/métodos , Diplopia/diagnóstico , Diplopia/etiologia , Diplopia/cirurgia , Órbita/diagnóstico por imagem , Órbita/cirurgia , Resultado do Tratamento
5.
Urology ; 141: e41-e42, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32305545

RESUMO

Pentosan Polysulfate Sodium (PPS) is commonly used in the treatment of interstitial cystitis/bladder pain syndrome. Recently there have been reported cases of retinal toxicity associated with long-term PPS use. We present a case of a 42-year-old female taking PPS for the last 10 years who was found to have signs of retinal toxicity, but was completely asymptomatic. PPS was discontinued after these retinal findings were discovered.


Assuntos
Poliéster Sulfúrico de Pentosana/efeitos adversos , Doenças Retinianas/induzido quimicamente , Adulto , Cistite Intersticial/tratamento farmacológico , Feminino , Humanos , Poliéster Sulfúrico de Pentosana/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA