Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Sci Rep ; 14(1): 5638, 2024 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454051

RESUMO

Transperineal fusion prostate biopsy has a considerable learning curve (LC). Robotic-assisted transperineal MRI/Ultrasound fusion-guided biopsy (RA-TP-FBx) may have an easier LC due to automatization. We aimed to assess the LC of RA-TP-FBx and analyze its most difficult steps. We prospectively analyzed cases randomized to a biopsy-naïve urology resident, the chief resident, and an expert urologist in RA-TP-FBx (controls). We also analyzed consecutive cases in the LC of the expert. The LC was defined by procedure time, PCa detection rate (including stratification by PI-RADS), entrustable professional activities (EPA) assessment scores, and the NASA task load index. We collectively performed 246 RA-TP-FBx with the Mona Lisa device. Procedure time for residents decreased steeply from maximum 53 min to minimum 10 min, while the mean procedure time for the expert was 9 min (range 17-5 min). PCa detection for PI-RADS-4 lesions was 57% for the naïve resident, 61% for the chief resident and 62% for the expert. There was also no difference in Pca detection for PI-RADS-4 lesions when comparing the first and second half of the experts' biopsies (p = 0.8). Maximum EPA score was registered after 22 cases. Workload steeply declined. Proficient RA-TP-FBx performance appears feasible after 22 cases regardless of previous experience.


Assuntos
Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos , Curva de Aprendizado , Biópsia Guiada por Imagem/métodos
2.
Quant Imaging Med Surg ; 13(7): 4284-4294, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37456296

RESUMO

Background: Diffuse parenchymal liver diseases are contributing substantially to global morbidity and represent major causes of deaths worldwide. The aim of our study is to assess whether established hepatic fat and iron quantitation and relaxometry-based quantification of hepatocyte-specific contrast material as surrogate for liver function estimation allows to evaluate liver fibrosis. Methods: Retrospective consecutive study. Seventy-two healthy patients (mean age: 53 years) without known liver disease, 21 patients with temporary elevated liver enzymes (mean: 65 years) and 109 patients with biopsy proven liver fibrosis or cirrhosis (mean: 61 years), who underwent liver magnetic resonance imaging (MRI) with a hepatocyte-specific contrast agent [gadoxetate disodium, gadolinium ethoxybenzyl-diethylenetriaminepentaacetic acid (Gd-EOB-DTPA), 0.25 mmol/mL Primovist, Bayer AG, Leverkusen, Germany] at 1.5 T (n=133) and at 3 T (n=69), were included. Fibrosis was classified using the histopathological meta-analysis of histological data in viral hepatitis (METAVIR) and the clinical Child-Pugh scores. Gd-concentration were quantified using T1 map-based calculations. Gd-concentration mapping was performed by using a Look-Locker approach prior to and 912±159 s after intravenous administration of hepatocyte specific contrast agent. Additionally, parenchymal fat fraction, R2*, bilirubin, gender and age were defined as predicting factors. Diagnostic accuracy was calculated in a monoparametric (linear regression, predictor: Gd-concentration) and multiparametric model (predictors: age, bilirubin level, iron overload, liver fat fraction, Gd concentration in the left and right liver lobe). Results: Mean Gd-concentration in the liver parenchyma was significantly higher for healthy patients ([Gd] =0.51 µmol/L) than for those with liver fibrosis or cirrhosis ([Gd] =0.31 µmol/L; P<0.0001) and with acute liver disease ([Gd] =0.28 µmol/L), though there were no significant differences for the latter two groups. There was a significant moderate negative correlation for the mean Gd-concentration and the METAVIR score (ρ=-0.44, P<0.0001) as well as for the Child-Pugh stage (ρ=-0.35, P<0.0001). There was a significant strong correlation between the bilirubin concentration and the Gd-concentration (ρ=-0.61, P<0.0001). The diagnostic accuracy for the discrimination of healthy patients and patients with known fibrosis or cirrhosis was 0.74 (0.71/0.60 sensitivity/specificity) in a monoparametric and 0.76 (0.85/0.61 sensitivity/specificity) in a machine learning based multiparametric model. Conclusions: T1 mapping-based quantification of hepatic Gd-EOB-DTPA concentrations performed in a multiparametric model shows promising diagnostic accuracy for the detection of fibrotic changes. Liver biopsy might be replaced by imaging examinations.

3.
Andrology ; 11(6): 1009-1015, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36427333

RESUMO

BACKGROUND: Prostate biopsy represents one of the most frequently performed urologic procedures worldwide and therefore presupposes knowledge on potential effects like on the erectile function, especially in extensive or repeated biopsies. The robotic-assisted biopsy system (Mona Lisa) offers a minimal invasive approach via only two incision points ensuring maximal accuracy combined with protection of the neurovascular bundle of the prostate. OBJECTIVE: Our purpose was to analyse the impact of robotic-assisted transperineal biopsy of the prostate on the erectile function. METHODS: Our prospective study analyses the outcomes of 210 patients, who had undergone minimal-invasive, transperineal robotic-assisted biopsy of the prostate at the University Hospital Basel from January 2020 to March 2022 and provided sufficient data. Of these, 157 (74.8%) were included in final analysis. RESULTS: Mean (range) age, prostate volume, PSA and IIEF-5 score at baseline were 63.8 years (46.1-83.6), 46.4 ml (9-310), 13.2 ng/ml (0.2-561), and 18.8 points (6-25), respectively. EF before and 1 month after intervention was assessed with the IIEF-5 questionnaire for the whole cohort. No significant change of IIEF-5 was observed for the whole cohort with a mean (± SD) decrease of 0.4 (± 3.1) points. Except for patients > 69 years, subgroup analysis revealed no change of IIEF-5 in statistically significant manner for all subgroups. Number of biopsy cores (< 20 and ≥ 20), previous biopsies and active surveillance showed no significant influence. CONCLUSION: Our results suggest that the minimally invasive and highly precise robotic technique can spare the erectile function without limiting the extent of biopsy and without compromising diagnostic accuracy.


Assuntos
Disfunção Erétil , Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Masculino , Humanos , Pessoa de Meia-Idade , Próstata/patologia , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Estudos Prospectivos , Biópsia/métodos
4.
Front Oncol ; 12: 1025355, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36531069

RESUMO

Introduction: Robotic-assisted transperineal MRI-US-fusion guided biopsy of the prostate is a novel and highly accurate procedure. The aim of this study was to evaluate the MonaLisa prostate biopsy system in terms of safety, tolerability, and patient-related outcomes. Methods: This prospective study included 228 patients, who had undergone Robotic-assisted transperineal MRI-US-fusion guided biopsy of the prostate at the University Hospital Basel between January 2020 and June 2022. Peri-operative side effects, functional outcomes and patient satisfaction were assessed. Results: Mean pain score on the day of biopsy was 1.3 points on VAS, which remained constant on the day after biopsy. Overall, 32 of 228 patients (14%) developed grade I complications according to Clavien-Dindo classification. No higher-grade complications occurred. Gross haematuria, hematospermia and acute urinary retention occurred in 145/228 (63.6%), 98/228 (43%) and 32/228 (14%) patients, respectively. One patient (0.4%) developed urinary tract infection. Conclusions: Robotic-assisted transperineal MRI-US-fusion guided biopsy of the prostate performed under general anesthesia is a safe and well tolerated procedure. This technique allows to omit perioperative prophylaxis and at the same time minimizes the risk of infectious complications. We attribute the favorable risk profile and tolerability to the minimal invasive approach via two entry points.

5.
Radiol Case Rep ; 17(3): 521-524, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34976257

RESUMO

In nature, basically 2 types of myocardial vascular patterns exist: the sinusoidal and the coronary type. In the sinusoidal type, the sinusoid is completely fed by blood coming directly from the ventricle through a spongy sinusoidal network. This pattern is found in cold-blooded animals and in the early embryologic development of human (warm-blooded) hearts. A 61-year-old man with atrial fibrillation developed severe tachymyopathy with a severely reduced left-ventricular ejection fraction (LVEF) of 20%. The patient had no history of prior heart surgery or other cardiac interventions. He was referred for a computed tomography (CT) scan for assessment of pulmonary vein anatomy prior to their isolation. Incidentally, a focal myocardial defect of the midventricular infero-septal wall with tail-like extension into the right ventricular cavity was detected. In a cardiac magnetic resonance (CMR) scan there was no evidence of a myocardial infarction or fibrosis. In the absence of a ventricular septal defect by CT, CMR and echocardiography the diagnosis of a persistent myocardial sinusoid was evident. In this case, we used state-of-the art methods for pathology visualization, illustrating the effectiveness of CT and CMR in the precise detection and differential diagnosis of myocardial anomalies including a multi-coloured 3D-printed model that may further enhance visuospatial appreciation of those anomalies.

6.
Sci Rep ; 11(1): 20250, 2021 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-34642448

RESUMO

MRI-targeted prostate biopsy improves detection of clinically significant prostate cancer (PCa). However, up to 70% of PCa lesions display intralesional tumor heterogeneity. Current target sampling strategies do not yet adequately account for this finding. This prospective study included 118 patients who underwent transperineal robotic assisted biopsy of the prostate. We identified a total of 58 PCa-positive PI-RADS lesions. We compared diagnostic accuracy of a target-saturation biopsy strategy to accuracy of single, two, or three randomly selected targeted biopsy cores and analysed potential clinical implications. Intralesional detection of clinically significant cancer (ISUP ≥ 2) was 78.3% for target-saturation biopsy and 39.1%, 52.2%, and 67.4% for one, two, and three targeted cores, respectively. Target-saturation biopsies led to a more accurate characterization of PCa in terms of Gleason score and reduced rates of significant cancer missed. Compared to one, two, and three targeted biopsy cores, target-saturation biopsies led to intensified staging procedures in 21.7%, 10.9, and 8.7% of patients, and ultimately to a potential change in therapy in 39.1%, 26.1%, and 10.9% of patients. This work presents the concept of robotic-assisted target saturation biopsy. This technique has the potential to improve diagnostic accuracy and thus individual staging procedures and treatment decisions.


Assuntos
Biópsia com Agulha de Grande Calibre/métodos , Biópsia Guiada por Imagem/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Neoplasias da Próstata/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estudos Prospectivos , Neoplasias da Próstata/patologia , Procedimentos Cirúrgicos Robóticos , Sensibilidade e Especificidade
7.
Eur J Radiol ; 142: 109894, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34388625

RESUMO

PURPOSE: To compare the performance of lesion detection and Prostate Imaging-Reporting and Data System (PI-RADS) classification between a deep learning-based algorithm (DLA), clinical reports and radiologists with different levels of experience in prostate MRI. METHODS: This retrospective study included 121 patients who underwent prebiopsy MRI and prostate biopsy. More than five radiologists (Reader groups 1, 2: residents; Readers 3, 4: less-experienced radiologists; Reader 5: expert) independently reviewed biparametric MRI (bpMRI). The DLA results were obtained using bpMRI. The reference standard was based on pathologic reports. The diagnostic performance of the PI-RADS classification of DLA, clinical reports, and radiologists was analyzed using AUROC. Dichotomous analysis (PI-RADS cutoff value ≥ 3 or 4) was performed, and the sensitivities and specificities were compared using McNemar's test. RESULTS: Clinically significant cancer [CSC, Gleason score ≥ 7] was confirmed in 43 patients (35.5%). The AUROC of the DLA (0.828) for diagnosing CSC was significantly higher than that of Reader 1 (AUROC, 0.706; p = 0.011), significantly lower than that of Reader 5 (AUROC, 0.914; p = 0.013), and similar to clinical reports and other readers (p = 0.060-0.661). The sensitivity of DLA (76.7%) was comparable to those of all readers and the clinical reports at a PI-RADS cutoff value ≥ 4. The specificity of the DLA (85.9%) was significantly higher than those of clinical reports and Readers 2-3 and comparable to all others at a PI-RADS cutoff value ≥ 4. CONCLUSIONS: The DLA showed moderate diagnostic performance at a level between those of residents and an expert in detecting and classifying according to PI-RADS. The performance of DLA was similar to that of clinical reports from various radiologists in clinical practice.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Humanos , Imageamento por Ressonância Magnética , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Radiologistas , Estudos Retrospectivos
8.
Quant Imaging Med Surg ; 10(4): 808-823, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32355645

RESUMO

BACKGROUND: To investigate if supervised machine learning (ML) classifiers would be able to predict clinically significant cancer (sPC) from a set of quantitative image-features and to compare these results with established PI-RADS v2 assessment scores. METHODS: We retrospectively included 201, histopathologically-proven, peripheral zone (PZ) prostate cancer lesions. Gleason scores ≤3+3 were considered as clinically insignificant (inPC) and Gleason scores ≥3+4 as sPC and were encoded in a binary fashion, serving as ground-truth. MRI was performed at 3T with high spatiotemporal resolution DCE using Golden-angle RAdial SParse (GRASP) MRI. Perfusion maps (Ktrans, Kep, Ve), apparent diffusion coefficient (ADC), and absolute T2-signal intensities (SI) were determined in all lesions and served as input parameters for four supervised ML models: Gradient Boosting Machines (GBM), Neural Networks (NNet), Random Forest (RF) and Support Vector Machines (SVM). ML results and PI-RADS scores were compared with the ground-truth. Next ROC-curves and AUC values were calculated. RESULTS: All ML models outperformed PI-RADS v2 assessment scores in the prediction of sPC (RF, GBM, NNet and SVM vs. PI-RADS: AUC 0.899, 0.864, 0.884 and 0.874 vs. 0.595, all P<0.001). CONCLUSIONS: Using quantitative imaging parameters as input, supervised ML models outperformed PI-RADS v2 assessment scores in the prediction of sPC. These results indicate that quantitative imagining parameters contain relevant information for the prediction of sPC from image features.

9.
World J Urol ; 38(7): 1729-1734, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31522235

RESUMO

PURPOSE: The aim of this study was to investigate whether structured reports (SRs) of prostate MRI results are more suitable than non-structured reports (NSRs) for promoting the more accurate assessment of the location of a single prostate cancer lesion by novices in MRI-targeted biopsy. METHODS: 50 NSRs and 50 SRs describing a single prostatic lesion were presented to 5 novices in MRI-targeted biopsy. The participants were asked to plot the tumor location in a two-dimensional prostate diagram and to answer a questionnaire on the quality of the reports. The accuracy of the plotted tumor position was evaluated with a validated 30-point scoring system that distinguished between "major" and "minor" mistakes. RESULTS: The overall mean score for the accuracy of the tumor plotting was significantly higher for SRs than for NSRs (26.4 vs. 20.7, p < 0.01). The mean numbers of major (1.4 vs. 0.48, p < 0.01) and minor (3.05 vs. 1.15, p < 0.01) mistakes were significantly higher for NSRs than for SRs. Compared with NSRs, SRs received significantly higher ratings for the perceived quality of the summary (4.0 vs. 2.4, p < 0.01) as well as for the overall satisfaction with the report (4.1 vs. 2.1, p < 0.01). CONCLUSION: Novices in MRI-targeted biopsy prefer structured reporting of prostate MRI as an information tool. SRs allow for a more accurate assessment of the location of single prostate cancer lesions. Therefore, structured reporting of prostate MRI may help to foster the learning process of novices in MRI-targeted biopsy.


Assuntos
Imageamento por Ressonância Magnética , Próstata/patologia , Neoplasias da Próstata/patologia , Relatório de Pesquisa/normas , Confiabilidade dos Dados , Humanos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA