Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Arthroplasty ; 39(7): 1714-1718, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38244639

RESUMO

BACKGROUND: Aseptic loosening is the most common mode of failure after total knee arthroplasty. Despite this, the diagnosis often remains challenging and mainly relies on imaging modalities. Until today, no biomarker exists to aid in diagnosing loosening of the implants. As zirconium (Zr) is often found in bone cement, where it serves as radiopacifier, this study aimed to establish Zr as a synovial biomarker for loosened cemented knee prostheses. METHODS: A total of 31 patients scheduled for revision of a cemented knee prostheses were included. In all patients, the initial used cement contained Zr. After arthrotomy, specimens of synovial fluid were taken and levels of Zr were measured by inductively coupled plasma mass spectrometry. Depending on the necessary amount of force for explantation, the implants were graded "loose" or "well-fixed". Preoperative radiographs were evaluated by 2 independent physicians. RESULTS: The concentration of Zr in the synovial fluid differed significantly (P < .001) between the "loose" (mean 170.9 µg/L, range 0 to 1941 µg/L) and the "well-fixed" (mean 0.6 µg/L, range 0 to 6 µg/L) implants. The receiver operating characteristic analysis revealed 0.25 µg/l as an optimal cutoff value leading to a sensitivity of 0.84, a specificity of 0.92, a positive predictive value of 0.94, and a negative predictive value of 0.79. There was no significant difference in the diagnostic performance compared to radiographs (P = .66). CONCLUSIONS: Zirconium proved to be a reliable novel synovial biomarker for diagnosing aseptic loosening of knee prothesis fixed with cement containing Zr. This biomarker should not be interpreted in isolation, but in combination with existing diagnostic tools.


Assuntos
Artroplastia do Joelho , Biomarcadores , Cimentos Ósseos , Prótese do Joelho , Falha de Prótese , Líquido Sinovial , Zircônio , Humanos , Zircônio/química , Idoso , Masculino , Feminino , Biomarcadores/análise , Líquido Sinovial/química , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Reoperação , Articulação do Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem
2.
Front Surg ; 10: 1223905, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38046102

RESUMO

Background: Scientific progress in the field of knee and hip arthroplasty has enabled the preservation of mobility and quality of life in the case of patients with many primary degenerative and (post-) traumatic joint diseases. This comparative study aims to investigate differences in scientific performance between the leading continents in the field of hip and knee arthroplasty. Methods: Using specific search terms all studies published by the scientific leading continents Europe, North America, Asia and Oceania listed in the Web of Science databases were included. All identified publications were analysed and comparative conclusions were drawn regarding the qualitative and quantitative scientific merit of each continent. Results: Europe, followed by North America, Asia, and Oceania, had the highest overall number of publications in the field of arthroplasty. Since 2000, there has been a strong increase in knee arthroplasty publication rate, particular pronounced in Asia. Studies performed and published in North America and those on knee arthroplasty received the highest number of fundings. Publications regarding hip arthroplasty achieved the highest average citation rate. In contradistinction to the others, in North America most funding was provided by private agencies. Conclusion: Although Europe showed the highest total number of publications, authors and institutions, arthroplasty research from North America received greater scientific attention and financial support. Measured by citations, publications on hip arthroplasty attained higher scientific interest and studies on knee arthroplasty received higher economic affection.

3.
Medicina (Kaunas) ; 59(9)2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37763727

RESUMO

Background: Revision hip arthroplasty presents a surgical challenge, necessitating meticulous preoperative planning to avert complications like periprosthetic fractures and aseptic loosening. Historically, assessment of the accuracy of three-dimensional (3D) versus two-dimensional (2D) templating has focused exclusively on primary hip arthroplasty. Materials and Methods: In this retrospective study, we examined the accuracy of 3D templating for acetabular revision cups in 30 patients who underwent revision hip arthroplasty. Utilizing computed tomography scans of the patients' pelvis and 3D templates of the implants (Aesculap Plasmafit, B. Braun; Aesculap Plasmafit Revision, B. Braun; Avantage Acetabular System, Zimmerbiomet, EcoFit 2M, Implantcast; Tritanium Revision, Stryker), we performed 3D templating and positioned the acetabular cup implants accordingly. To evaluate accuracy, we compared the planned sizes of the acetabular cups in 2D and 3D with the sizes implanted during surgery. Results: An analysis was performed to examine potential influences on templating accuracy, specifically considering factors such as gender and body mass index (BMI). Significant statistical differences (p < 0.001) in the accuracy of size prediction were observed between 3D and 2D templating. Personalized 3D templating exhibited an accuracy rate of 66.7% for the correct prediction of the size of the acetabular cup, while 2D templating achieved an exact size prediction in only 26.7% of cases. There were no statistically significant differences between the 2D and 3D templating methods regarding gender or BMI. Conclusion: This study demonstrates that 3D templating improves the accuracy of predicting acetabular cup sizes in revision arthroplasty when compared to 2D templating. However, it should be noted that the predicted implant size generated through 3D templating tended to overestimate the implanted implant size by an average of 1.3 sizes.


Assuntos
Artroplastia de Quadril , Humanos , Estudos Retrospectivos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Índice de Massa Corporal , Pelve
4.
Front Surg ; 10: 1187223, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37377669

RESUMO

Introduction: Arthroplasty is the final treatment option for maintaining mobility and quality of life in many primary degenerative and (post-) traumatic joint diseases. Identification of research output and potential deficits for specific subspecialties may be an important measure to achieve long-term improvement of patient care in this field. Methods: Using specific search terms and Boolean operators, all studies published since 1945 to the subgroups of arthroplasty listed in the Web of Science Core Collection were included. All identified publications were analysed according to bibliometric standards, and comparative conclusions were drawn regarding the scientific merit of each subgroup. Results: Most publications investigated the subgroups of septic surgery and materials followed by approach, navigation, aseptic loosening, robotic and enhanced recovery after surgery (ERAS). In the last 5 years, research in the fields of robotic and ERAS achieved the highest relative increase in publications In contrast, research on aseptic loosening has continued to lose interest over the last 5 years. Publications on robotics and materials received the most funding on average while those on aseptic loosening received the least. Most publications originated from USA, Germany, and England, except for research on ERAS in which Denmark stood out. Relatively, publications on aseptic loosening received the most citations, whereas the absolute scientific interest was highest for the topic infection. Discussion: In this bibliometric subgroup analysis, the primary scientific outputs focused on septic complications and materials research in the field of arthroplasty. With decreasing publication output and the least financial support, intensification of research on aseptic loosening is urgently recommended.

5.
Orthopadie (Heidelb) ; 52(7): 532-538, 2023 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-37286621

RESUMO

BACKGROUND: For the preparation of surgical procedures in orthopedics and trauma surgery, precise knowledge of imaging and the three-dimensional imagination of the surgeon are of outstanding importance. Image-based, preoperative two-dimensional planning is the gold standard in arthroplasty today. In complex cases, further imaging such as computed tomography (CT) or magnetic resonance imaging is also performed, generating a three-dimensional model of the body region and helping the surgeon in the planning of the surgical treatment. Four-dimensional, dynamic CT studies have also been reported and are available as a complementary tool. DIGITAL AIDS: Furthermore, digital aids should generate an improved representation of the pathology to be treated and optimize the surgeon's imagination. The finite element method allows patient-specific and implant-specific parameters to be taken into account in preoperative surgical planning. Intraoperatively, relevant information can be provided by augmented reality without significantly influencing the surgical workflow.


Assuntos
Síndrome da Imunodeficiência Adquirida , Realidade Aumentada , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Tomografia Computadorizada Quadridimensional
6.
Ann Anat ; 248: 152081, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36871868

RESUMO

BACKGROUND: Advanced core decompression (ACD) is a relative new technique for treatment of early stages of avascular femoral head necrosis. Although it is a promising treatment option, there is a need to modify this technique for achieving higher hip survival rates. An idea was to combine this technique with the lightbulb procedure in order to get a complete removal of the necrosis. This study aimed at evaluating the fracture risk of the femora treated by the combined Lightbulb-ACD technique as the basis for clinical application. METHODS: Subject-specific models were generated from CT scan data of five intact femora. Several treated models were then created from each intact bone and simulated during normal walking activity. Biomechanical testing was additionally performed on 12 pairs of cadaver femora to confirm the simulation results. FINDINGS: The finite element results revealed that the risk factor of the treated models with a 8 mm-drill increased, but was not significantly greater than that of their corresponding intact models. However, for the femur treated with a 10 mm-drill, the risk factor increased significantly. Fracture always initiated on the femoral neck, i.e. it was either subcapital or transcervical fracture. Our biomechanical testing results correlated well with the simulation data which confirmed the usefulness and effectiveness of the bone models. INTERPRETATION: The combined Lightbulb-ACD technique using a 10 mm drill increased the fracture risk of femur postoperatively. A drill of up to 8 mm at the anterior head-neck junction did not however lead to the weakening of the femur so that full load bearing may be possible.


Assuntos
Necrose da Cabeça do Fêmur , Procedimentos Ortopédicos , Humanos , Colo do Fêmur/cirurgia , Cabeça do Fêmur/cirurgia , Necrose da Cabeça do Fêmur/cirurgia , Fêmur , Fenômenos Biomecânicos , Análise de Elementos Finitos
7.
Orthopadie (Heidelb) ; 51(10): 800-807, 2022 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-36136134

RESUMO

Atraumatic femoral head necrosis (aFHN) in adults is estimated to be the leading cause of approximately 10% of all hip prosthesis implantations. Due to the relatively frequent occurrence of aFHN at a young age, the possibility of a joint-preserving intervention should be examined. This includes the classic "core decompression" and modifications based on it. There are different data on the success rates of this method. Reasons for treatment failure could include a lack of clearance of the necrosis zone. The clearance of the necrosis zone is taken into account by alternative surgical procedures for the treatment of aFHN. These are the "trap-door procedure", the "light-bulb procedure" and "advanced core decompression". The current state of knowledge on these procedures is reviewed in this keynote article. It is shown that the extensive excision of femoral head necrosis is of particular importance. None of the procedures mentioned can currently be recommended in preference over the others.


Assuntos
Artroplastia de Quadril , Necrose da Cabeça do Fêmur , Procedimentos Ortopédicos , Adulto , Descompressão Cirúrgica/métodos , Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/cirurgia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA