Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
AJNR Am J Neuroradiol ; 45(2): 139-148, 2024 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-38164572

RESUMO

Resting-state (rs) fMRI has been shown to be useful for preoperative mapping of functional areas in patients with brain tumors and epilepsy. However, its lack of standardization limits its widespread use and hinders multicenter collaboration. The American Society of Functional Neuroradiology, American Society of Pediatric Neuroradiology, and the American Society of Neuroradiology Functional and Diffusion MR Imaging Study Group recommend specific rs-fMRI acquisition approaches and preprocessing steps that will further support rs-fMRI for future clinical use. A task force with expertise in fMRI from multiple institutions provided recommendations on the rs-fMRI steps needed for mapping of language, motor, and visual areas in adult and pediatric patients with brain tumor and epilepsy. These were based on an extensive literature review and expert consensus.Following rs-fMRI acquisition parameters are recommended: minimum 6-minute acquisition time; scan with eyes open with fixation; obtain rs-fMRI before both task-based fMRI and contrast administration; temporal resolution of ≤2 seconds; scanner field strength of 3T or higher. The following rs-fMRI preprocessing steps and parameters are recommended: motion correction (seed-based correlation analysis [SBC], independent component analysis [ICA]); despiking (SBC); volume censoring (SBC, ICA); nuisance regression of CSF and white matter signals (SBC); head motion regression (SBC, ICA); bandpass filtering (SBC, ICA); and spatial smoothing with a kernel size that is twice the effective voxel size (SBC, ICA).The consensus recommendations put forth for rs-fMRI acquisition and preprocessing steps will aid in standardization of practice and guide rs-fMRI program development across institutions. Standardized rs-fMRI protocols and processing pipelines are essential for multicenter trials and to implement rs-fMRI as part of standard clinical practice.


Assuntos
Neoplasias Encefálicas , Epilepsia , Humanos , Criança , Adulto , Mapeamento Encefálico/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Idioma , Encéfalo/diagnóstico por imagem
2.
Eur J Neurol ; 27(5): 864-870, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32068938

RESUMO

BACKGROUND AND PURPOSE: Among patients with an acute ischaemic stroke secondary to large-vessel occlusion, the hypoperfusion intensity ratio (HIR) [time to maximum (TMax) > 10 volume/TMax > 6 volume] is a strong predictor of infarct growth. We studied the correlation between HIR and collaterals assessed with digital subtraction angiography (DSA) before thrombectomy. METHODS: Between January 2014 and March 2018, consecutive patients with an acute ischaemic stroke and an M1 middle cerebral artery (MCA) occlusion who underwent perfusion imaging and endovascular treatment at our center were screened. Ischaemic core (mL), HIR and perfusion mismatch (TMax > 6 s minus core volume) were assessed through magnetic resonance imaging or computed tomography perfusion. Collaterals were assessed on pre-intervention DSA using the American Society of Interventional and Therapeutic Neuroradiology/Society of Interventional Radiology (ASITN/SIR) scale. Baseline clinical and perfusion characteristics were compared between patients with good (ASITN/SIR score 3-4) and those with poor (ASITN/SIR score 0-2) DSA collaterals. Correlation between HIR and ASITN/SIR scores was evaluated using Pearson's correlation. Receiver operating characteristic analysis was performed to determine the optimal HIR threshold for the prediction of good DSA collaterals. RESULTS: A total of 98 patients were included; 49% (48/98) had good DSA collaterals and these patients had significantly smaller hypoperfusion volumes (TMax > 6 s, 89 vs. 125 mL; P = 0.007) and perfusion mismatch volumes (72 vs. 89 mL; P = 0.016). HIR was significantly correlated with DSA collaterals (-0.327; 95% confidence interval, -0.494 to -0.138; P = 0.01). An HIR cut-off of <0.4 best predicted good DSA collaterals with an odds ratio of 4.3 (95% confidence interval, 1.8-10.1) (sensitivity, 0.792; specificity, 0.560; area under curve, 0.708). CONCLUSION: The HIR is a robust indicator of angiographic collaterals and might be used as a surrogate of collateral assessment in patients undergoing magnetic resonance imaging. HIR <0.4 best predicted good DSA collaterals.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Isquemia Encefálica/diagnóstico por imagem , Circulação Colateral , Humanos , Trombectomia
3.
AJNR Am J Neuroradiol ; 40(2): 206-212, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30655254

RESUMO

Magnetic particle imaging is an emerging tomographic technique with the potential for simultaneous high-resolution, high-sensitivity, and real-time imaging. Magnetic particle imaging is based on the unique behavior of superparamagnetic iron oxide nanoparticles modeled by the Langevin theory, with the ability to track and quantify nanoparticle concentrations without tissue background noise. It is a promising new imaging technique for multiple applications, including vascular and perfusion imaging, oncology imaging, cell tracking, inflammation imaging, and trauma imaging. In particular, many neuroimaging applications may be enabled and enhanced with magnetic particle imaging. In this review, we will provide an overview of magnetic particle imaging principles and implementation, current applications, promising neuroimaging applications, and practical considerations.


Assuntos
Fenômenos Magnéticos , Neuroimagem/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Nanopartículas
4.
AJNR Am J Neuroradiol ; 39(9): 1635-1642, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30093483

RESUMO

BACKGROUND AND PURPOSE: Early and accurate identification of cerebral metastases is important for prognostication and treatment planning although this process is often time consuming and labor intensive, especially with the hundreds of images associated with 3D volumetric imaging. This study aimed to evaluate the benefits of thick-slab overlapping MIPs constructed from contrast-enhanced T1-weighted CUBE (overlapping CUBE MIP) for the detection of brain metastases in comparison with traditional CUBE and inversion-recovery prepared fast-spoiled gradient recalled brain volume (IR-FSPGR-BRAVO) and nonoverlapping CUBE MIP. MATERIALS AND METHODS: A retrospective review of 48 patients with cerebral metastases was performed at our institution from June 2016 to October 2017. Brain MRIs, which were acquired on multiple 3T scanners, included gadolinium-enhanced T1-weighted IR-FSPGR-BRAVO and CUBE, with subsequent generation of nonoverlapping CUBE MIP and overlapping CUBE MIP. Two blinded radiologists identified the total number and location of metastases on each image type. The Cohen κ was used to determine interrater agreement. Sensitivity, interpretation time, and lesion contrast-to-noise ratio were assessed. RESULTS: Interrater agreement for identification of metastases was fair-to-moderate for all image types (κ = 0.222-0.598). The total number of metastases identified was not significantly different across the image types. Interpretation time for CUBE MIPs was significantly shorter than for CUBE and IR-FSPGR-BRAVO, saving at least 50 seconds per case on average (P < .001). The mean lesion contrast-to-noise ratio for both CUBE MIPs was higher than for IR-FSPGR-BRAVO. The mean contrast-to-noise ratio for small lesions (<4 mm) was lower for nonoverlapping CUBE MIP (1.55) than for overlapping CUBE MIP (2.35). For both readers, the sensitivity for lesion detection was high for all image types but highest for overlapping CUBE MIP and CUBE (0.93-0.97). CONCLUSIONS: This study suggests that the use of overlapping CUBE MIP or nonoverlapping CUBE MIP for the detection of brain metastases can reduce interpretation time without sacrificing sensitivity, though the contrast-to-noise ratio of lesions is highest for overlapping CUBE MIP.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Metástase Neoplásica/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/secundário , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Masculino , Pessoa de Meia-Idade , Neuroimagem/métodos , Projetos Piloto , Estudos Retrospectivos , Sensibilidade e Especificidade , Fatores de Tempo
5.
AJNR Am J Neuroradiol ; 37(12): 2251-2257, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27561834

RESUMO

BACKGROUND AND PURPOSE: Despite a recent resurgence, intravoxel incoherent motion MRI faces practical challenges, including limited SNR and demanding acquisition and postprocessing requirements. A simplified approach using linear fitting of a subset of higher b-values has seen success in other organ systems. We sought to validate this method for evaluation of brain pathology by comparing perfusion measurements using simplified linear fitting to conventional biexponential fitting. MATERIALS AND METHODS: Forty-nine patients with gliomas and 17 with acute strokes underwent 3T MRI, including DWI with 16 b-values (range, 0-900 s/mm2). Conventional intravoxel incoherent motion was performed using nonlinear fitting of the standard biexponential equation. Simplified intravoxel incoherent motion was performed using linear fitting of the log-normalized signal curves for subsets of b-values >200 s/mm2. Comparisons between ROIs (tumors, strokes, contralateral brain) and between models (biexponential and simplified linear) were performed by using 2-way ANOVA. The root mean square error and coefficient of determination (R2) were computed for the simplified model, with biexponential fitting as the reference standard. RESULTS: Perfusion maps using simplified linear fitting were qualitatively similar to conventional biexponential fitting. The perfusion fraction was elevated in high-grade (n = 33) compared to low-grade (n = 16) gliomas and was reduced in strokes compared to the contralateral brain (P < .001 for both main effects). Decreasing the number of b-values used for linear fitting resulted in reduced accuracy (higher root mean square error and lower R2) compared with full biexponential fitting. CONCLUSIONS: Intravoxel incoherent motion perfusion imaging of common brain pathology can be performed by using simplified linear fitting, with preservation of clinically relevant perfusion information.


Assuntos
Encéfalo/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Modelos Teóricos , Encéfalo/patologia , Neoplasias Encefálicas/irrigação sanguínea , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Glioma/irrigação sanguínea , Glioma/diagnóstico por imagem , Glioma/patologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Imagem de Perfusão/métodos , Reprodutibilidade dos Testes , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/patologia
6.
AJNR Am J Neuroradiol ; 37(7): 1206-8, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26939630

RESUMO

BACKGROUND AND PURPOSE: A neuroradiologist's activity includes many tasks beyond interpreting relative value unit-generating imaging studies. Our aim was to test a simple method to record and quantify the non-relative value unit-generating clinical activity represented by consults and clinical conferences, including tumor boards. MATERIALS AND METHODS: Four full-time neuroradiologists, working an average of 50% clinical and 50% academic activity, systematically recorded all the non-relative value unit-generating consults and conferences in which they were involved during 3 months by using a simple, Web-based, computer-based application accessible from smartphones, tablets, or computers. The number and type of imaging studies they interpreted during the same period and the associated relative value units were extracted from our billing system. RESULTS: During 3 months, the 4 neuroradiologists working an average of 50% clinical activity interpreted 4241 relative value unit-generating imaging studies, representing 8152 work relative value units. During the same period, they recorded 792 non-relative value unit-generating study reviews as part of consults and conferences (not including reading room consults), representing 19% of the interpreted relative value unit-generating imaging studies. CONCLUSIONS: We propose a simple Web-based smartphone app to record and quantify non-relative value unit-generating activities including consults, clinical conferences, and tumor boards. The quantification of non-relative value unit-generating activities is paramount in this time of a paradigm shift from volume to value. It also represents an important tool for determining staffing levels, which cannot be performed on the basis of relative value unit only, considering the importance of time spent by radiologists on non-relative value unit-generating activities. It may also influence payment models from medical centers to radiology departments or practices.


Assuntos
Centros Médicos Acadêmicos/estatística & dados numéricos , Eficiência Organizacional , Eficiência , Neurologistas/economia , Radiologistas/economia , Centros Médicos Acadêmicos/economia , Humanos , Aplicativos Móveis , Admissão e Escalonamento de Pessoal , Encaminhamento e Consulta , Smartphone , Recursos Humanos
7.
AJNR Am J Neuroradiol ; 36(6): E41-51, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25907520

RESUMO

MR perfusion imaging is becoming an increasingly common means of evaluating a variety of cerebral pathologies, including tumors and ischemia. In particular, there has been great interest in the use of MR perfusion imaging for both assessing brain tumor grade and for monitoring for tumor recurrence in previously treated patients. Of the various techniques devised for evaluating cerebral perfusion imaging, the dynamic susceptibility contrast method has been employed most widely among clinical MR imaging practitioners. However, when implementing DSC MR perfusion imaging in a contemporary radiology practice, a neuroradiologist is confronted with a large number of decisions. These include choices surrounding appropriate patient selection, scan-acquisition parameters, data-postprocessing methods, image interpretation, and reporting. Throughout the imaging literature, there is conflicting advice on these issues. In an effort to provide guidance to neuroradiologists struggling to implement DSC perfusion imaging in their MR imaging practice, the Clinical Practice Committee of the American Society of Functional Neuroradiology has provided the following recommendations. This guidance is based on review of the literature coupled with the practice experience of the authors. While the ASFNR acknowledges that alternate means of carrying out DSC perfusion imaging may yield clinically acceptable results, the following recommendations should provide a framework for achieving routine success in this complicated-but-rewarding aspect of neuroradiology MR imaging practice.


Assuntos
Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Neurologia/normas , Imagem de Perfusão/métodos , Radiologia/normas , Humanos , Neurologia/métodos , Radiologia/métodos
8.
AJNR Am J Neuroradiol ; 35(10): 1959-64, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24904051

RESUMO

BACKGROUND AND PURPOSE: A 4D CT protocol for detection of parathyroid lesions involves obtaining unenhanced, arterial, early, and delayed venous phase images. The aim of the study was to determine the ideal combination of phases that would minimize radiation dose without sacrificing diagnostic accuracy. MATERIALS AND METHODS: With institutional review board approval, the records of 29 patients with primary hyperparathyroidism who had undergone surgical exploration were reviewed. Four neuroradiologists who were blinded to the surgical outcome reviewed the imaging studies in 5 combinations (unenhanced and arterial phase; unenhanced, arterial, and early venous; all 4 phases; arterial alone; arterial and early venous phases) with an interval of at least 7 days between each review. The accuracy of interpretation in lateralizing an abnormality to the side of the neck (right, left, ectopic) and localizing it to a quadrant in the neck (right or left upper, right or left lower) was evaluated. RESULTS: The lateralization and localization accuracy (90.5% and 91.5%, respectively) of the arterial phase alone was comparable with the other combinations of phases. There was no statistically significant difference among the different combinations of phases in their ability to lateralize or localize adenomas to a quadrant (P = .976 and .996, respectively). CONCLUSIONS: Assessment of a small group of patients shows that adequate diagnostic accuracy for parathyroid adenoma localization may be achievable by obtaining arterial phase images alone. If this outcome can be validated prospectively in a larger group of patients, then the radiation dose can potentially be reduced to one-fourth of what would otherwise be administered.


Assuntos
Adenoma/diagnóstico por imagem , Tomografia Computadorizada Quadridimensional/métodos , Hiperparatireoidismo Primário/diagnóstico por imagem , Neoplasias das Paratireoides/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
AJNR Am J Neuroradiol ; 35(11): 2052-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24970545

RESUMO

BACKGROUND AND PURPOSE: CT is the imaging modality of choice to study the paranasal sinuses; unfortunately, it involves significant radiation dose. Our aim was to assess the diagnostic validity, image quality, and radiation-dose savings of dental conebeam CT in the evaluation of patients with suspected inflammatory disorders of the paranasal sinuses. MATERIAL AND METHODS: We prospectively studied 40 patients with suspected inflammatory disorders of the sinuses with dental conebeam CT and standard CT. Two radiologists analyzed the images independently, blinded to clinical information. The image quality of both techniques and the diagnostic validity of dental conebeam CT compared with the reference standard CT were assessed by using 3 different scoring systems. Image noise, signal-to-noise ratio, and contrast-to-noise ratio were calculated for both techniques. The absorbed radiation dose to the lenses and thyroid and parotid glands was measured by using a phantom and dosimeter chips. The effective radiation dose for CT was calculated. RESULTS: All dental conebeam CT scans were judged of diagnostic quality. Compared with CT, the conebeam CT image noise was 37.3% higher (P < .001) and the SNR of the bone was 75% lower (P < .001). The effective dose of our conebeam CT protocol was 23 µSv. Compared with CT, the absorbed radiation dose to the lenses and parotid and thyroid glands with conebeam CT was 4%, 7.8%, and 7.3% of the dose delivered to the same organs by conventional CT (P < .001). CONCLUSIONS: Dental conebeam CT is a valid imaging procedure for the evaluation of patients with inflammatory sinonasal disorders.


Assuntos
Seios Paranasais/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Sinusite/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Prospectivos
10.
AJNR Am J Neuroradiol ; 35(5): 891-6, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24371027

RESUMO

BACKGROUND AND PURPOSE: MR imaging-guided focused sonography surgery is a new stereotactic technique that uses high-intensity focused sonography to heat and ablate tissue. The goal of this study was to describe MR imaging findings pre- and post-ventralis intermedius nucleus lesioning by MR imaging-guided focused sonography as a treatment for essential tremor and to determine whether there was an association between these imaging features and the clinical response to MR imaging-guided focused sonography. MATERIALS AND METHODS: Fifteen patients with medication-refractory essential tremor prospectively gave consent; were enrolled in a single-site, FDA-approved pilot clinical trial; and were treated with transcranial MR imaging-guided focused sonography. MR imaging studies were obtained on a 3T scanner before the procedure and 24 hours, 1 week, 1 month, and 3 months following the procedure. RESULTS: On T2-weighted imaging, 3 time-dependent concentric zones were seen at the site of the focal spot. The inner 2 zones showed reduced ADC values at 24 hours in all patients except one. Diffusion had pseudonormalized by 1 month in all patients, when the cavity collapsed. Very mild postcontrast enhancement was seen at 24 hours and again at 1 month after MR imaging-guided focused sonography. The total lesion size and clinical response evolved inversely compared with each other (coefficient of correlation = 0.29, P value = .02). CONCLUSIONS: MR imaging-guided focused sonography can accurately ablate a precisely delineated target, with typical imaging findings seen in the days, weeks, and months following the treatment. Tremor control was optimal early when the lesion size and perilesional edema were maximal and was less later when the perilesional edema had resolved.


Assuntos
Tremor Essencial/patologia , Tremor Essencial/cirurgia , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imageamento por Ressonância Magnética/métodos , Cirurgia Assistida por Computador/métodos , Idoso , Tremor Essencial/diagnóstico por imagem , Feminino , Humanos , Estudos Longitudinais , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Ultrassonografia
11.
AJNR Am J Neuroradiol ; 34(11): E117-27, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23907247

RESUMO

SUMMARY: Stroke is a leading cause of death and disability worldwide. Imaging plays a critical role in evaluating patients suspected of acute stroke and transient ischemic attack, especially before initiating treatment. Over the past few decades, major advances have occurred in stroke imaging and treatment, including Food and Drug Administration approval of recanalization therapies for the treatment of acute ischemic stroke. A wide variety of imaging techniques has become available to assess vascular lesions and brain tissue status in acute stroke patients. However, the practical challenge for physicians is to understand the multiple facets of these imaging techniques, including which imaging techniques to implement and how to optimally use them, given available resources at their local institution. Important considerations include constraints of time, cost, access to imaging modalities, preferences of treating physicians, availability of expertise, and availability of endovascular therapy. The choice of which imaging techniques to employ is impacted by both the time urgency for evaluation of patients and the complexity of the literature on acute stroke imaging. Ideally, imaging algorithms should incorporate techniques that provide optimal benefit for improved patient outcomes without delaying treatment.


Assuntos
Angiografia Cerebral/normas , Ataque Isquêmico Transitório/diagnóstico , Neurorradiografia/normas , Guias de Prática Clínica como Assunto , Radiologia Intervencionista/normas , Acidente Vascular Cerebral/diagnóstico , Humanos , Ataque Isquêmico Transitório/terapia , Acidente Vascular Cerebral/terapia , Estados Unidos
12.
AJNR Am J Neuroradiol ; 34(5): 1104-10, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23348759

RESUMO

Arachnoid webs are intradural extramedullary bands of arachnoid tissue that can extend to the pial surface of the spinal cord, causing a focal dorsal indentation of the cord. These webs tend to occur in the upper thoracic spine and may produce a characteristic deformity of the cord that we term the "scalpel sign." We describe 14 patients whose imaging studies demonstrated the scalpel sign. Ten of 13 patients who underwent MR imaging demonstrated T2WI cord signal-intensity changes, and 7 of these patients also demonstrated syringomyelia adjacent to the level of indentation. Seven patients underwent surgery, with 5 demonstrating an arachnoid web as the cause of the dorsal indentation demonstrated on preoperative imaging. Although the webs themselves are rarely demonstrated on imaging, we propose that the scalpel sign is a reliable indicator of their presence and should prompt consideration of surgical lysis, which is potentially curative.


Assuntos
Aracnoide-Máter/anormalidades , Aracnoide-Máter/patologia , Imageamento por Ressonância Magnética/métodos , Siringomielia/patologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
J Cardiovasc Surg (Torino) ; 54(3): 373-81, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22820738

RESUMO

AIM: The goal of this study was to identify physical characteristics of primary intimal tears in patients arriving to the hospital alive with acute type A aortic dissection using 64-multislice computerized tomography (MSCT) in order to determine anatomic feasibility of endovascular stent-grafting (ESG) for future treatment. METHODS: Radiology database was screened for acute type A aortic dissection since the time of acquisition of the 64-slice CT scanner and cross-referenced with surgical database. Seventeen patients met inclusion criteria. Images were reviewed for number, location, and size of intimal tears and aortic dimensions. Potential obstacles for ESG were determined. RESULTS: Ascending aorta (29%) and sinotubular junction (29%) were the most frequent regions where intimal tears originated. Location of intimal tears in nearly 75% of patients was inappropriate for ESG, and 94% of patients did not have sufficient proximal or distal landing zone required for secure fixation. Only 71% of patients underwent surgical aortic dissection repair after imaging and 86% of entry tears detected on MSCT were confirmed on intraoperative documentation. Only one patient would have met all technical criteria for ESG using currently available devices. CONCLUSION: Location of intimal tear, aortic valve insufficiency, aortic diameter>38 mm are major factors limiting use of ESG for acute type A dissection. Available stents used to treat type B aortic dissection do not address anatomic constraints present in type A aortic dissection in the majority of cases, such that development of new devices would be required.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Prótese Vascular , Procedimentos Endovasculares , Seleção de Pacientes , Stents , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento , Túnica Íntima/diagnóstico por imagem
14.
AJNR Am J Neuroradiol ; 32(1): 41-8, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20947643

RESUMO

BACKGROUND AND PURPOSE: SHT and ME are feared complications in patients with acute ischemic stroke. They occur >10 times more frequently in tPA-treated versus placebo-treated patients. Our goal was to evaluate the sensitivity and specificity of admission BBBP measurements derived from PCT in predicting the development of SHT and ME in patients with acute ischemic stroke. MATERIALS AND METHODS: We retrospectively analyzed a dataset consisting of 32 consecutive patients with acute ischemic stroke with appropriate admission and follow-up imaging. We calculated admission BBBP by using delayed-acquisition PCT data and the Patlak model. Collateral flow was assessed on the admission CTA, while recanalization and reperfusion were assessed on the follow-up CTA and PCT, respectively. SHT and ME were defined according to ECASS III criteria. Clinical data were obtained from chart review. In our univariate and forward selection-based multivariate analysis for predictors of SHT and ME, we incorporated both clinical and imaging variables, including age, admission NIHSS score, admission blood glucose level, admission blood pressure, time from symptom onset to scanning, treatment type, admission PCT-defined infarct volume, admission BBBP, collateral flow, recanalization, and reperfusion. Optimal sensitivity and specificity for SHT and ME prediction were calculated by using ROC analysis. RESULTS: In our sample of 32 patients, 3 developed SHT and 3 developed ME. Of the 3 patients with SHT, 2 received IV tPA, while 1 received IA tPA and treatment with the Merci device; of the 3 patients with ME, 2 received IV tPA, while 1 received IA tPA and treatment with the Merci device. Admission BBBP measurements above the threshold were 100% sensitive and 79% specific in predicting SHT and ME. Furthermore, all patients with SHT and ME--and only those with SHT and ME--had admission BBBP measurements above the threshold, were older than 65 years of age, and received tPA. Admission BBBP, age, and tPA were the independent predictors of SHT and ME in our forward selection-based multivariate analysis. Of these 3 variables, only BBBP measurements and age were known before making the decision of administering tPA and thus are clinically meaningful. CONCLUSIONS: Admission BBBP, a pretreatment measurement, was 100% sensitive and 79% specific in predicting SHT and ME.


Assuntos
Barreira Hematoencefálica/fisiopatologia , Edema Encefálico/diagnóstico por imagem , Edema Encefálico/fisiopatologia , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/fisiopatologia , Ataque Isquêmico Transitório/diagnóstico por imagem , Ataque Isquêmico Transitório/fisiopatologia , Imagem de Perfusão/métodos , Idoso , Idoso de 80 Anos ou mais , Volume Sanguíneo , Barreira Hematoencefálica/diagnóstico por imagem , Edema Encefálico/etiologia , Hemorragia Cerebral/etiologia , Feminino , Humanos , Ataque Isquêmico Transitório/complicações , Masculino , Pessoa de Meia-Idade , Permeabilidade , Tomografia Computadorizada por Raios X/métodos
15.
J Neuroradiol ; 37(4): 239-42, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19959233

RESUMO

This article reports perfusion-CT patterns that can be observed in patients with DVAs. In atypical DVAs, an abnormal venous congestion pattern with increased CBV, CBF and MTT can be observed in the vicinity of a DVA, and needs to be recognized and differentiated from other entities such as cerebral neoplasms or stroke. This pattern might help to stratify risks of associated complications such as hemorrhage.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Veias Cerebrais/anormalidades , Veias Cerebrais/diagnóstico por imagem , Imagem de Perfusão/métodos , Adulto , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Radiografia
16.
J Neurol Neurosurg Psychiatry ; 81(3): 282-5, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19850577

RESUMO

BACKGROUND: Intravenous recombinant tissular plasminogen activator (rt-PA) is the only approved pharmacological treatment for acute ischaemic stroke. The authors aimed to analyse potential causes of the variable effect on early course and late outcome. METHODS AND RESULTS: 136 patients (42% women, 58% men) treated with intravenous rt-PA within 3 h of stroke onset in an acute stroke unit over a 3-year period, were included. Early clinical profiles of evolution at 48 h were divided into clinical improvement (CI) (decrease >4 points in the National Institute of Health Stroke Scale (NIHSS)); clinical worsening (CW) (increase >4 points NIHSS); clinical worsening after initial improvement (CWFI) (variations of >4 points in the NIHSS). Patients with clinical stability (no NIHSS modification or <4 points) were excluded. The patients showed in 66.9% CI, 13.2% CW 8.1 % CWFI and 11.8% remained stable. Female sex, no hyperlipaemia and peripheral arterial disease were associated with CW. Male sex and smoking were associated with CI. Absence of arterial occlusion on admission (28.4%) and arterial recanalisation at 24 h were associated with CI. Main causes of clinical deterioration included symptomatic intracranial haemorrhage (sICH), persistent occlusion and cerebral oedema. 23.5% developed ICH, 6.6% of which had sICH. At 3 months, 15.5% had died. Mortality was increased in CW, mainly related to sICH and cerebral oedema. The outcome of CWFI was intermediate between CW and CI. CONCLUSIONS: Early clinical profiles of evolution in thrombolysed patients vary considerably. Even with CI, it is critical to maintain vessel permeability to avoid subsequent CW.


Assuntos
Infarto Cerebral/tratamento farmacológico , Fibrinolíticos/administração & dosagem , Terapia Trombolítica , Ativador de Plasminogênio Tecidual/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Edema Encefálico/diagnóstico , Edema Encefálico/diagnóstico por imagem , Edema Encefálico/mortalidade , Angiografia Cerebral , Infarto Cerebral/diagnóstico , Infarto Cerebral/diagnóstico por imagem , Infarto Cerebral/mortalidade , Progressão da Doença , Feminino , Fibrinolíticos/efeitos adversos , Humanos , Hemorragias Intracranianas/induzido quimicamente , Hemorragias Intracranianas/diagnóstico , Hemorragias Intracranianas/diagnóstico por imagem , Hemorragias Intracranianas/mortalidade , Hipertensão Intracraniana/diagnóstico , Hipertensão Intracraniana/diagnóstico por imagem , Hipertensão Intracraniana/mortalidade , Masculino , Pessoa de Meia-Idade , Exame Neurológico/efeitos dos fármacos , Prognóstico , Recidiva , Fatores Sexuais , Taxa de Sobrevida , Ativador de Plasminogênio Tecidual/efeitos adversos , Tomografia Computadorizada Espiral , Resultado do Tratamento , Adulto Jovem
17.
J Neuroradiol ; 35(5): 297-300, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18692898

RESUMO

Lhermitte-Duclos disease (LDD) is a rare benign lesion of uncertain pathogenesis characterised by distortion of the normal cerebellar laminar cytoarchitecture. We report a case of LDD thoroughly characterized by advanced magnetic resonance imaging techniques, with diffusion-weighted, perfusion-weighted and post-gadolinium sequences. Imaging showed restricted diffusion consistent with high cellularity, high degree of vascularity and preserved blood-brain barrier permeability, correlating with pathology.


Assuntos
Neoplasias Encefálicas/diagnóstico , Síndrome do Hamartoma Múltiplo/diagnóstico , Imageamento por Ressonância Magnética/métodos , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/cirurgia , Meios de Contraste , Diagnóstico Diferencial , Feminino , Síndrome do Hamartoma Múltiplo/patologia , Síndrome do Hamartoma Múltiplo/cirurgia , Humanos , Pessoa de Meia-Idade
18.
J Neuroradiol ; 35(5): 253-60, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18466974

RESUMO

Perfusion computed tomography (PCT) is an imaging technique that allows rapid, noninvasive, quantitative evaluation of cerebral perfusion by generating maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT). The concepts behind this imaging technique were developed in the 1980s', but its widespread clinical use was allowed by the recent introduction of rapid, large-coverage multidetector-row CT scanners. Key clinical applications for PCT include the diagnosis of cerebral ischemia and infarction, and evaluation of vasospasm after subarachnoid hemorrhage. PCT measurements of cerebrovascular reserve after acetazolamide challenges in patients with vascular stenoses permit evaluation of candidacy for bypass surgery and endovascular treatment. PCT has also been used to assess cerebral perfusion after head trauma and microvascular permeability in the setting of intracranial neoplasm. Some controversy exists regarding this technique, including questions regarding correct selection of an arterial input vessel, the accuracy of quantitative results, and the reproducibility of results. This article provides an overview of PCT, including details of technique, major clinical applications, and limitations.


Assuntos
Encefalopatias/diagnóstico por imagem , Circulação Cerebrovascular , Tomografia Computadorizada por Raios X/métodos , Velocidade do Fluxo Sanguíneo , Neoplasias Encefálicas/diagnóstico por imagem , Traumatismos Craniocerebrais/diagnóstico por imagem , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador , Acidente Vascular Cerebral/diagnóstico por imagem , Vasoespasmo Intracraniano/diagnóstico por imagem
19.
Radiol Med ; 112(8): 1225-43, 2007 Dec.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-18074193

RESUMO

The imaging of brain haemodynamics and its applications are generating growing interest. By providing quantitative measurements of cerebral blood flow (CBF) and cerebral blood volume (CBV), dynamic perfusion computed tomography (p-CT) allows visualisation of cerebral autoregulation mechanisms and represents a fast, available and reliable imaging option for assessing cerebral perfusion. Thanks to its feasibility in emergency settings, p-CT is considered most useful, in combination with CT angiography, in acute ischaemic patients, as it is able to provide a fast and noninvasive assessment of cerebral perfusion impairment. In addition, p-CT can play a diagnostic role in other types of cerebrovascular disease to assess functional reserve, and in intracranial neoplasms, where it has a role in diagnosis, grading, biopsy guidance, and follow-up during treatment. This article illustrates the principles, technique and clinical applications of p-CT cerebral perfusion studies.


Assuntos
Encefalopatias/diagnóstico por imagem , Circulação Cerebrovascular , Tomografia Computadorizada por Raios X/métodos , Artefatos , Volume Sanguíneo , Meios de Contraste , Hemodinâmica , Humanos
20.
AJNR Am J Neuroradiol ; 28(9): 1628-32, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17893208

RESUMO

Within the past 2 decades, the number of CT examinations performed has increased almost 10-fold. This is in large part due to advances in multidetector-row CT technology, which now allows faster image acquisition and improved isotropic imaging. The increased use, along with multidetector technique, has led to a significantly increased radiation dose to the patient from CT studies. This places increased responsibility on the radiologist to ensure that CT examinations are indicated and that the "as low as reasonably achievable" concept is adhered to. Neuroradiologists are familiar with factors that affect patient dose such as pitch, milliamperes, kilovolt peak (kVp), collimation, but with increasing attention being given to dose reduction, they are looking for additional ways to further reduce the radiation associated with their CT protocols. In response to increasing concern, CT manufacturers have developed dose-reduction tools, such as dose modulation, in which the tube current is adjusted along with the CT acquisition, according to patient's attenuation. This review will describe the available techniques for reducing dose associated with neuroradiologic CT imaging protocols.


Assuntos
Neurorradiografia/métodos , Guias de Prática Clínica como Assunto , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Humanos , Neurorradiografia/tendências , Padrões de Prática Médica/tendências , Doses de Radiação , Lesões por Radiação/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA