Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Transpl Int ; 34(12): 2755-2768, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34561920

RESUMO

The aim of this study was to analyze first year renal outcomes in a nationwide prospective multicenter cohort comprising 2215 renal transplants, with a special emphasis on the presence of pre-transplant donor-specific HLA antibodies (DSA). All transplants had a complete virtual crossmatch and DSA were detected in 19% (411/2215). The investigated composite endpoint was a poor first-year outcome defined as (i) allograft failure or (ii) death or (iii) poor allograft function (eGFR ≤25 ml/min/1.73 m2 ) at one year. Two hundred and twenty-one (221/2215; 10%) transplants showed a poor first-year outcome. Rejection (24/70; 34%) was the most common reason for graft failure. First-year patient's death was rare (48/2215; 2%). There were no statistically significant differences between DSA-positive and DSA-negative transplants regarding composite and each individual endpoint, as well as reasons for graft failure and death. DSA-positive transplants experienced more frequently rejection episodes, mainly antibody-mediated rejection (both P < 0.0001). The combination of DSA and any first year rejection was associated with the overall poorest death-censored allograft survival (P < 0.0001). In conclusion, presence of pre-transplant DSA per se does not affect first year outcomes. However, DSA-positive transplants experiencing first year rejection are a high-risk population for poor allograft survival and may benefit from intense clinical surveillance.


Assuntos
Transplante de Rim , Estudos de Coortes , Rejeição de Enxerto , Sobrevivência de Enxerto , Antígenos HLA , Humanos , Isoanticorpos , Estudos Prospectivos , Estudos Retrospectivos , Suíça , Doadores de Tecidos
2.
Proc Biol Sci ; 285(1886)2018 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-30209229

RESUMO

Individuals are thought to have their own distinctive body odour which reportedly plays an important role in mate choice. In the present study we investigated individual differences in body odours of women and examined whether some women generally smell more attractive than others or whether odour preferences are a matter of individual taste. We then explored whether levels of reproductive hormones explain women's body odour attractiveness, to test the idea that body odour attractiveness may act as a chemosensory marker of reproductive fitness. Fifty-seven men rated body odours of 28 healthy, naturally cycling women of reproductive age. We collected all odours at peak fertility to control for menstrual cycle effects on body odour attractiveness. Women's salivary oestradiol, progesterone, testosterone and cortisol levels were assessed at the time of odour collection to test whether hormone levels explain body odour attractiveness. We found that the men highly agreed on how attractive they found women's body odours. Interestingly, women's body odour attractiveness was predicted by their oestradiol and progesterone levels: the higher a woman's levels of oestradiol and the lower her levels of progesterone, the more attractive her body odour was rated. In showing that women's body odour attractiveness is explained by levels of female reproductive hormones, but not by levels of cortisol or testosterone, we provide evidence that body odour acts as a valid cue to potential fertility.


Assuntos
Estradiol/metabolismo , Estrogênios/metabolismo , Individualidade , Odorantes/análise , Progesterona/metabolismo , Progestinas/metabolismo , Adolescente , Adulto , Sinais (Psicologia) , Feminino , Fertilidade/fisiologia , Humanos , Masculino , Ciclo Menstrual , Comportamento Sexual/fisiologia , Adulto Jovem
3.
Transfusion ; 42(5): 527-36, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12084160

RESUMO

BACKGROUND: The FDA requirement for sensitivity of viral NAT methods used in blood screening is a 95-percent detection limit of 100 copies per mL, whereas the NAT screening system should have a sensitivity of at least 5000 copies per mL per individual donation. According to the Common Technical Specifications of the European Directive 98/79/EC for in vitro diagnostics, viral standard dilutions (calibrated against the WHO standard) should be tested at least 24 times for a statistically valid assessment of the 95-percent detection limit. STUDY DESIGN AND METHODS: Viral standard dilution panels (PeliCheck, VQC-CLB) were prepared for HCV RNA genotypes 1 and 3 and for HIV RNA genotypes B and E. In a multicenter study, 23 laboratories tested the panels all together in 8 to 91 test runs per NAT method. RESULTS: The following 95-percent detection limits (and 95% CIs) were found on the HCV RNA genotype 1 reference panels (shown as geq/mL): Gen-Probe TMA, 85 (64-118); AmpliScreen, 126 (83-225); AmpliScreen with NucliSens Extractor, 21 (13-44); Amplicor with NucliSens Extractor, 69 (50-102), and Amplicor with Qiagen extraction technology, 144 (74-102). On HIV RNA genotype B dilution panels, the following 95-percent detection limits were found (shown as geq/mL): Gen-Probe TMA, 31 (20-52); AmpliScreen, 126 (67-311); AmpliScreen with NucliSens Extractor, 37 (23-69), and NucliSens QL assay, 123 (51-566). HIV RNA genotype E panels were detected with equal sensitivity as HIV RNA genotype B panels. In the Gen-Probe TMA assay, the 50-percent detection limits on HIV RNA type B and type E were 3.6 (2.6-5.0) and 3.9 (2.4-5.8) geq per mL, respectively. The HCV RNA genotype 1 and 3 standards were detected with equal sensitivity. CONCLUSION: The differences in sensitivity between NAT assays can be explained by the input of isolated viral nucleic acid in the amplification reactions. The FDA requirements for sensitivity of NAT blood screening assays can be met by the Gen-probe TMA, as well as by the AmpliScreen assays, particularly when combined with the NucliSens Extractor.


Assuntos
Transfusão de Sangue/normas , HIV/isolamento & purificação , Hepacivirus/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico , RNA Viral/sangue , Kit de Reagentes para Diagnóstico/normas , Viremia/diagnóstico , Adsorção , Austrália , Automação , Europa (Continente) , Genótipo , HIV/genética , Hepacivirus/genética , Humanos , Magnetismo , RNA Viral/isolamento & purificação , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dióxido de Silício , Transcrição Gênica , Ultracentrifugação , Estados Unidos , United States Food and Drug Administration , Viremia/virologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA