Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Ann Thorac Cardiovasc Surg ; 29(5): 241-248, 2023 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-36990786

RESUMO

PURPOSE: To analyse the outcome of coronary artery bypass grafting (CABG) in octogenarians with coronary multivessel disease and the impact of different graft strategies and other factors. METHODS: Out of 1654 patients with multivessel disease who underwent CABG at our institution between January 2014 and March 2020, we investigated 225 consecutive patients with a median age of 82.1 years for survival prediction and need for coronary reintervention; a detailed outcome analysis was performed. RESULTS: At mean follow-up of 3.3 years, the overall survival was 76.4%. An indication for emergency operation (p = 0.002), age (p <0.001), chronic pulmonary disease (p = 0.024), and reduced renal or ventricular function (p <0.001) had the highest impact on limited survival. The combination outcome of survival and coronary reintervention was 1.7-fold improved (p = 0.024) after use of the bilateral internal thoracic artery (BITA) (66.2%). Off-pump CABG (12%) revealed no impact on survival. Smokers showed a poorer outcome (p = 0.004). The logistic European System for Cardiac Operative Risk Evaluation was highly effective for evaluating long-term outcomes (p <0.001). CONCLUSIONS: BITA grafting normalizes survival and reveals a better outcome in octogenarians with multivessel disease. However, patients at risk of poorer survival were operated under emergency conditions and those with pulmonary disease and reduced ventricular or renal function.

2.
Oncol Res Treat ; 46(5): 201-210, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36822167

RESUMO

INTRODUCTION: SARS-CoV-2 infected patients with cancer have a worse outcome including a significant higher mortality, compared to non-cancer patients. However, limited data are available regarding in-hospital mortality during the Omicron phase of the pandemic. Therefore, the aim of the study was the comparison of mortality in patients with history of cancer and patients with active cancer disease during the different phases of the COVID-19 pandemic, focusing on the current Omicron variant of concern. METHODS: We conducted a multicenter, observational, epidemiological cohort study at 45 hospitals in Germany. Until July 20, 2022, all adult hospitalized SARS-CoV-2 positive patients were included. The primary endpoint was in-hospital mortality regarding cancer status (history of cancer and active cancer disease) and SARS-CoV-2 virus type. RESULTS: From March 11, 2020, to July 20, 2022, a total of 27,490 adult SARS-CoV-2 positive patients were included in the study. 2,578 patients (9.4%) had diagnosis of cancer, of whom 1,065 (41.3%) had history of cancer, whereas 1,513 (58.7%) had active cancer disease. Overall 3,749 out of the total of 27,490 patients (13.6%) died during the hospital stay. Patients with active cancer disease had a significantly higher mortality compared to patients without cancer diagnosis, in both phases of the pandemic (wild-type to Delta: OR 1.940 [1.646-2.285]); Omicron: 2.864 [2.354-3.486]). After adjustment to co-variables, SARS-CoV-2 infected patients with active cancer disease had the highest risk for in-hospital mortality compared to the other groups, in both phases of the pandemic. CONCLUSION: The CORONA Germany study indicates that hospitalized patients with active cancer disease are at high risk of death during a SARS-CoV-2 infection. Mortality of patients with history of cancer improved to nearly the level of non-cancer patients during Omicron phase.


Assuntos
COVID-19 , Neoplasias , Adulto , Humanos , SARS-CoV-2 , Mortalidade Hospitalar , Pandemias , Estudos de Coortes , Alemanha/epidemiologia
3.
EPMA J ; 13(3): 451-460, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36061830

RESUMO

Background: Surgical replacement of the aortic root is the only intervention that can prevent aortic dissection and cardiovascular death in Marfan syndrome (MFS). However, in some individuals, MFS also causes sleep apnea. If sleep apnea predicts cardiovascular death, a new target for predictive, preventive, and personalized medicine (PPPM) may emerge for those individuals with MFS who have sleep apnea. Methods: This is an investigator-initiated study with long-term follow-up data of 105 individuals with MFS. All individuals were screened for sleep apnea regardless of symptoms. Cardiovascular death served as a primary endpoint, and aortic events as a secondary outcome. Results: Sleep apnea with an apnea-hypopnea index (AHI) > 5/h was observed in 21.0% (22/105) with mild sleep apnea in 13% (14/105) and moderate to severe sleep apnea in 7.6% (8/105). After a median follow-up of 7.76 years (interquartile range: 6.84, 8.41), 10% (10/105) had died, with cardiovascular cause of death in 80% (8/10). After adjusting for age and body mass index (BMI), the AHI score emerged as an independent risk factor for cardiovascular death (hazard ratio 1.712, 95% confidence interval [1.061-2.761], p = 0.0276). The secondary outcome of aortic events occurred in 33% (35/105). There was no effect of the AHI score on aortic events after adjusting for age and BMI (hazard ratio 0.965, 95% confidence interval [0.617-1.509]), possibly due to a high number of patients with prior aortic surgery. Interpretation: Sleep apnea is emerging as an independent predictor of cardiovascular death in MFS. It seems mandatory to screen all individuals with MFS for sleep apnea and to include these individuals, with both MFS and sleep apnea, in further studies to evaluate the impact of preventive measures with regard to cardiovascular death. Supplementary Information: The online version contains supplementary material available at 10.1007/s13167-022-00291-4.

4.
Pacing Clin Electrophysiol ; 45(9): 1024-1031, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35822917

RESUMO

BACKGROUND: Perimitral flutter and atrial fibrillation may occur in patients with prior surgical mitral valve (MV) repair or replacement and can be challenging for percutaneous catheter ablation. This study sought to determine the feasibility, acute success and durability of catheter ablation of atrial fibrillation or atrial tachycardia by way of a mitral isthmus line (MIL) or an anterior line (AL). METHODS: A total of 81 patients (49 males, mean age 62±11 years) with prior MV replacement (n = 30) or reconstruction (n = 51) underwent creation of a MIL (34) and/or an AL (72). RESULTS: Acute bidirectional block of the MIL was successfully achieved in 24/34 cases and of the AL in 64/72 patients. Patients of the control group without prior MV surgery were matched 1:1 with the valve group. In the AL control subgroup, acute bidirectional block was achieved in 65/72 patients. Acute blockage in the MIL control subgroup could be achieved in 31/34 patients. The MIL valve subgroup showed the worst results in terms of durability, whereas a similar trend emerged in the control group and the AL valve subgroup (probability of failure in MIL valve subgroup 2.224 vs. MIL control subgroup 0.605 [Hazard Ratio (HR) = 0.27, 95% confidence interval (CI), 0.11-0.65), P = .004]; probability of failure in AL valve subgroup 0.844 vs. AL control subgroup 1.03 [HR = 1.22 (95% CI, 0.66-2.26), P = .523]). CONCLUSIONS: Percutaneous creation of MIL and AL is feasible and safe in patients with prior MV replacement/repair and associated with moderate acute and long-term success rates to achieve bidirectional block.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Idoso , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 33(6): 1096-1103, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35304790

RESUMO

BACKGROUND: Cryoballoon (CB)-based pulmonary vein isolation (PVI) has proven to be as effective as radiofrequency-based ablation. Different ablation protocols took the individual time-to-isolation (TTI) into account aiming at shorter but equally or even more effective freeze cycles. The current study sought to assess the impact of the TTI on PVI durability in patients undergoing a repeat procedure for recurrence of atrial tachyarrhythmia (ATA). METHODS AND RESULTS: In 205 patients with ATA recurrence after previous CB-based PVI, a total of 806 pulmonary veins (PVs) were identified. A total of 126 out of 806 PVs (16%) were previously treated with a TTI-guided ablation (Protocol #1; TTI + 120 s), in 92/806 (11%) PVs TTI was only monitored (m) but fixed freeze cycles were applied (Protocol #2; mTTI) and in 588/806 (73%) a fixed freeze cycle was applied without mTTI. There was no difference in the PV-reconduction rate between the groups (p = .23). The right inferior pulmonary vein (RIPV) showed overall significantly higher reconduction rates compared to the other PVs (RIPV-left inferior PV p < .003, -left superior PV p < .001, -right superior PV p < .013). Twenty-one patients (10%) were demonstrated to have only electrical reconduction of the RIPV, while all other PVs were still electrically isolated. CONCLUSIONS: The TTI-based CB ablation protocol did not show significant differences regarding PV-reconduction rates compared to the other ablation protocols.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
6.
Ann Thorac Cardiovasc Surg ; 28(3): 186-192, 2022 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-35046210

RESUMO

OBJECTIVE: To analyze the results of hemoadsorption in patients with cardiac surgery to thoracic aortic surgery, who had been loaded beforehand with either Factor Xa inhibitor rivaroxaban or P2Y12 receptor antagonist ticagrelor. METHODS: We investigated 21 of 171 consecutive patients (median age 71 [interquartile range 62, 76] years) who underwent emergency cardiac operations for acute type A aortic dissection between 2014 and 2020. These patients were pretreated with rivaroxaban (n = 9) or ticagrelor (n = 12). In ten of 21 cases (since 2017), we installed a hemoadsorber into the heart-lung machine and compared the results to eleven patients done without hemoadsorber before that time. RESULTS: The operation time was significantly shorter in the adsorber group (286 ± 40 min vs. 348 ± 79 min; p = 0.045). The postoperative 24-hour drainage volume was significantly lower after adsorption (p <0.001; 482 ± 122 ml vs. 907 ± 427 ml) and no rethoracotomy had to be performed (compared to two rethoracotomies [18.9%] among patients without adsorber use). Also, patients without hemoadsorption required significantly more platelet transfusions (p = 0.049). CONCLUSIONS: In patients with acute type A aortic dissection who were pretreated with rivaroxaban and ticagrelor, the intraoperative use of CytoSorb hemoadsorption during cardiopulmonary bypass is reported for the first time. The method was found to be effective to prevent from bleeding and to improve the outcome in aortic dissection.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Procedimentos Cirúrgicos Cardíacos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Humanos , Rivaroxabana/efeitos adversos , Ticagrelor/efeitos adversos , Resultado do Tratamento
7.
Clin Res Cardiol ; 111(5): 530-540, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34318341

RESUMO

AIMS: Catheter ablation of ventricular arrhythmias (VA) has proven to be an effective therapeutic option for secondary arrhythmia prophylaxis. We sought to assess the procedural efficacy, safety and in-hospital mortality of a large patient cohort with and without structural heart disease undergoing VA ablation. METHODS: A total of 1417 patients (804 patients with structural heart disease) undergoing 1792 endo- and epicardial procedures were analyzed. Multivariable risk factor analysis for occurrence of major complications and intrahospital mortality was obtained and a score to allow preprocedural risk assessment for patients undergoing VA ablation procedures was established. RESULTS: Major complication occurred in 4.4% of all procedures and significantly more often in patients with structural heart disease than in structurally normal hearts (6.0 vs. 1.8%). The frequency of these periprocedural complications was significantly different between procedures with sole right ventricular and a combination of RV and LV access (0.5 vs. 3.1%). The most common complication was cardiac tamponade in 46 cases (3.0%). Intrahospital death was observed in 32 patients (1.8%). Logistic regression model revealed presence of ischemic heart disease, epicardial ablation, presence of oral anticoagulation or dual antiplatelet therapy as independent risk factors for the occurrence of complications or intrahospital death, while a history of previous heart surgery was an independent predictor with a decreased risk. Based on this analysis a risk score incorporating 5 standard variables was established to predict the occurrence of complications and intrahospital mortality. CONCLUSIONS: Safety of VA catheter ablation mainly relies on patient baseline characteristics and the type of access into the ventricles or epicardial space.


Assuntos
Tamponamento Cardíaco , Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas/etiologia , Tamponamento Cardíaco/etiologia , Ablação por Cateter/métodos , Humanos , Fatores de Risco , Resultado do Tratamento
8.
Cardiol J ; 29(5): 807-814, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33140384

RESUMO

BACKGROUND: The current study sought to assess the impact of the intraprocedural heart rhythm (sinus rhythm [SR] vs. atrial fibrillation [AF]) on acute procedural characteristics, durability of pulmonary vein isolation (PVI) and long-term clinical outcomes of cryoballoon (CB) ablation. METHODS: A total of 195 patients with symptomatic paroxysmal (n = 136) or persistent AF (n = 59) underwent CB-based PVI. Ablation procedures were either performed in SR (SR group; n = 147) or during AF (AF group; n = 48). Persistent AF was more frequent in the AF group than in the SR group (62% vs. 20%). All other patient baseline characteristics did not differ between the two groups. RESULTS: The nadir temperature during the CB applications was significantly lower in the AF group than in patients in the SR group (-49 [interquartile range, -44; -54]°C vs. -47 [-42; -52]°C, p = 0.002). Median procedure and fluoroscopy times as well as the rate of real-time recordings were not different between the two groups. Repeat ablation for the treatment of atrial arrhythmia recurrence was performed in 60 patients (SR: 44 [30%] patients; AF: 16 [33%] patients), with a trend towards a lower rate of pulmonary vein reconnections in the AF group (p = 0.07). There was no difference in 3-year arrhythmia-free survival (p = 0.8). CONCLUSIONS: Cryoballoon-based PVI during AF results in lower nadir balloon temperatures and a trend towards a higher durability of PVI as compared to procedures performed in SR. The rate of real-time PVI recordings was not affected by the intraprocedural heart rhythm.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
9.
Int Heart J ; 62(1): 65-71, 2021 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-33455982

RESUMO

Left atrial (LA) fibrosis is associated with a poor outcome after atrial fibrillation (AF) ablation. This study examined the extent of low-voltage areas in patients with recurrence of atrial tachyarrhythmia (ATA) after CB-based pulmonary vein isolation (PVI).Sixty patients (mean age 67 ± 10 years, n = 32 female; n = 34 paroxysmal AF) who received radiofrequency redo-procedure due to recurrence of ATA within 6 months after CB-based PVI were included. A point-by point 3D-map was performed, and low-voltage sites were delineated based on bipolar voltage < 0.5 mV. The extent of fibrosis was categorized as stage A (0-10% of the LA wall), stage B (10-30%), stage C (30-50%), and stage D (> 50%).The median area of LA low-voltage sites was 28.9 (9; 50.3) cm2, corresponding to 17.4 (6; 30.6) % of the LA wall surface. 17/60 (28.3%) patients were categorized as fibrosis stage A, 21/60 (35%) as stage B, 18/60 (30%) as stage C, and 4/60 (6.7%) as stage D. Patient age and LA diameter were associated with more pronounced LA fibrosis; the extent of LA fibrosis was significantly higher in patients with LA tachycardia (LAT) during redo-procedures (P < 0.01), and ablation of linear lesions was more often performed (P < 0.01).In patients after CB2-based PVI, expanded LA tissue fibrosis was associated with the occurrence of LAT and more extensive LA ablation during redo-procedures.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Fibrose/complicações , Átrios do Coração/patologia , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Feminino , Fibrose/classificação , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Taquicardia Supraventricular/epidemiologia , Taquicardia Supraventricular/etiologia , Resultado do Tratamento
10.
Clin Res Cardiol ; 110(6): 810-821, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32719917

RESUMO

INTRODUCTION: Pericardial access for ablation of ventricular arrhythmias (VA) can be gained either by an anterior-oriented or inferior-oriented epicardial puncture under fluoroscopical guidance. We retrospectively sought to assess the safety of these two puncture techniques and the incidence of epicardial adhesions and introduce our algorithm for management of pericardial tamponade. METHODS AND RESULTS: In 211 patients (61.4 ± 15.6 years, 179 males; 84.8%) 271 epicardial ablation procedures of VA were performed using either an anterior- or inferior-oriented approach for epicardial access. Puncture-related complications were systematically analyzed. Furthermore, the incidence of adhesions was evaluated during first and repeated procedures. A total of 34/271 (12.5%) major complications occurred and 23/271 (8.5%) were directly related to epicardial puncture. The incidence of puncture-related major complications in the anterior and inferior group was 4/82 (4.9%) and 19/189 (10.1%), respectively. Pericardial tamponade was the most common major complication (15/271; 5.5%). Collateral damages of adjacent structures such as liver, colon, gastric vessels and coronary arteries occurred in 6/189 (3.2%) patients and only within the inferior epicardial access group. Adhesions were documented in 19/211 (9%) patients during the first procedure and in 47.1% if patients had 2 or more procedures involving epicardial access. CONCLUSION: Anterior-oriented epicardial puncture shows an observed association to a reduced incidence of pericardial tamponades and overall puncture-related complications in epicardial ablation of VA. In cases of repeated epicardial access adhesions increase significantly and may lead to ablation failure.


Assuntos
Ablação por Cateter/métodos , Gerenciamento Clínico , Pericárdio/cirurgia , Complicações Pós-Operatórias/epidemiologia , Punções/efeitos adversos , Taquicardia Ventricular/cirurgia , Aderências Teciduais/epidemiologia , Algoritmos , Ablação por Cateter/efeitos adversos , Feminino , Fluoroscopia/métodos , Seguimentos , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Pericárdio/diagnóstico por imagem , Complicações Pós-Operatórias/terapia , Punções/métodos , Estudos Retrospectivos , Cirurgia Assistida por Computador , Taquicardia Ventricular/diagnóstico , Aderências Teciduais/etiologia , Resultado do Tratamento
11.
Cancers (Basel) ; 14(1)2021 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-35008282

RESUMO

Percutaneous hepatic perfusion (PHP) delivers high-dose melphalan to the liver while minimizing systemic toxicity via filtration of the venous hepatic blood. This two-center study aimed to examine the safety, response to therapy, and survival of patients with hepatic-dominant metastatic uveal melanoma (UM) treated with PHP. A total of 66 patients with liver-dominant metastasized uveal melanoma, treated with 145 PHP between April 2014 and May 2020, were retrospectively analyzed with regard to adverse events (AEs; CTCAE v5.0), response (overall response rate (ORR)), and disease control rate (DCR) according to RECIST1.1, as well as progression-free and overall survival (PFS and OS). With an ORR of 59% and a DCR of 93.4%, the response was encouraging. After initial PHP, median hepatic PFS was 12.4 (confidence interval (CI) 4-18.4) months and median OS was 18.4 (CI 7-24.6) months. Hematologic toxicity was the most frequent AE (grade 3 or 4 thrombocytopenia after 24.8% of the procedures); less frequent was grade 3 or 4 hepatic toxicity (increased aspartate transaminase (AST) and alanine transaminase (ALT) after 7.6% and 6.9% of the interventions, respectively). Cardiovascular events included four cases of ischemic stroke (2.8%) and one patient with central pulmonary embolism (0.7%). In conclusion, PHP is a safe and effective salvage treatment for liver-dominant metastatic uveal melanoma. Serious AEs-though rare-demand careful patient selection.

12.
EuroIntervention ; 16(17): 1447-1454, 2021 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-33074154

RESUMO

AIMS: Failure of transcatheter mitral valve repair (fTMVR) therapy has a decisive prognostic influence, and complex retreatment is of higher risk. The aim of this analysis was to evaluate the survival outcome following percutaneous procedures and surgery after unsuccessful TMVR interventions for different aetiologies. METHODS AND RESULTS: Of 824 consecutive patients who had been treated with the MitraClip device at our institution, between September 2009 and May 2019, 63 (7.6%) symptomatic patients with therapy failure and persistent or recurrent mitral regurgitation (MR) underwent reinterventions. An outcome analysis for primary (PMR) and secondary mitral regurgitation (SMR) and subsequent percutaneous versus surgical treatment was carried out. MitraClip reinterventions were performed in 36 patients (57.1%; n=26 SMR, n=10 PMR), while 27 (42.9%; n=13 SMR, n=14 PMR) underwent open heart surgery. Surgical patients with PMR showed lower mortality than patients with SMR (p<0.0001) and ReClip patients with PMR (p=0.073). Atrial fibrillation (HR 2.915, 95% CI: [1.311, 6.480]), prior open heart surgery (2.820 [1.215, 6.544]) and chronic obstructive pulmonary disease (2.506 [1.099, 5.714]) increased the risk of death. The level of post-interventional MR had no relevant impact on survival. CONCLUSIONS: We conclude that, after SMR and failed TMVR, reclipping is an appropriate treatment option for symptomatic patients. For PMR patients, surgery must be favoured over a reclipping procedure. However, patients with atrial fibrillation, prior open heart surgery and chronic obstructive pulmonary disease are at risk of reduced survival after reinterventions.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
13.
Knee ; 27(4): 1143-1150, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32711875

RESUMO

BACKGROUND: The reoperation rate after primary meniscal repair is about 20%. Thus far, it has remained unclear whether there are distinct individual preconditions that may be associated with a better or worse outcome of this procedure. We therefore analysed typical biochemical mediators in the synovial fluid (SF) of patients with meniscus tear before arthroscopic meniscal refixation and correlated their concentrations to the occurrence of re-rupture after meniscus repair. METHODS: In this study, 48 patients with meniscus ruptures were included. SF samples were taken intraoperatively prior to arthroscopy. Multiplex enzyme-linked immunosorbent assay (ELISA)-based methods were used to measure hepatocyte growth factor (HGF), interleukin-18 (IL-18), matrix metalloproteinases (MMP) MMP-1, MMP-2, MMP-9 and MMP-13 in the SF. At follow-up, the patients were classified into two groups: surgical success and surgical failure. RESULTS: Ten out of 48 patients (20.8%) had to undergo revision surgery after meniscal repair (surgical failure). The median HGF in the surgical failure group was 2.4-times higher than in the surgical success group (P = .006), and the median MMP-2 was 1.8 times higher (P = .017). Concentration levels of the other tested proteins were not correlated with the success or failure of the meniscus surgery. There was weak evidence that both markers are indicators of an unsatisfactory healing process for meniscal refixation. CONCLUSION: These results suggest that HGF and MMP-2 could serve as molecular markers to estimate the chances of healing success of meniscus repair and possibly to individualise therapy in meniscal surgery.


Assuntos
Artroscopia , Fator de Crescimento de Hepatócito/metabolismo , Metaloproteinase 2 da Matriz/metabolismo , Líquido Sinovial/metabolismo , Lesões do Menisco Tibial/metabolismo , Lesões do Menisco Tibial/cirurgia , Adulto , Biomarcadores/metabolismo , Feminino , Humanos , Articulação do Joelho/cirurgia , Masculino , Meniscos Tibiais/cirurgia , Reoperação , Cirurgia de Second-Look , Resultado do Tratamento , Cicatrização , Adulto Jovem
14.
Europace ; 22(8): 1240-1251, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32500141

RESUMO

AIMS: The aim of this study was to analyse tamponades following electrophysiological procedures regarding frequency and mortality in a high-volume centre and to identify independent predictors for severe tamponades. METHODS AND RESULTS: We performed a retrospective study on 34 982 consecutive patients undergoing diagnostic electrophysiological studies or catheter ablation of cardiac arrhythmias. The combined endpoint was defined as severe tamponade. Criteria for severe tamponade included surgical repair, repeat pericardiocentesis, cardiopulmonary resuscitation, intrahospital death or death during follow-up, and thrombo-embolic events or complications due to therapeutic management. Multivariate analysis was performed to identify independent predictors for severe tamponade. A total of 226 tamponades were identified. Overall frequency of tamponades was 0.6%. Procedures requiring epicardial approach had the highest rate of tamponades (9.4%). Twenty-nine patients with tamponade underwent surgery (12.8% of all tamponades and 21.4% of tamponades during epicardial procedures). Overall tamponade-related mortality was 0.03% (9 deaths). Fifty-six patients (24.8%) experienced severe tamponade. Independent risk factors for severe tamponades were endocardial ablation of ventricular tachycardia, epicardial approach, balloon device ablation, high aspiration volume during pericardiocentesis and structural heart disease. CONCLUSION: The frequency of tamponades is strongly dependent on the type of procedure performed. Overall tamponade-related mortality was low but significantly higher in patients undergoing epicardial procedures. Surgical backup should be considered for patients undergoing complex ventricular tachycardia ablation and left atrial ablation procedures.


Assuntos
Tamponamento Cardíaco , Ablação por Cateter , Eletrofisiologia Cardíaca , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Pericardiocentese/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
15.
Int J Cardiol ; 312: 73-80, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32241572

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) using the second-generation cryoballoon (CB2) for atrial fibrillation (AF) treatment has demonstrated encouraging procedural success rates and mid-term results. However, long-term follow-up data on outcome is sparse. The current study is reporting on five-year clinical outcomes following CB2-based PVI in patients with paroxysmal AF (PAF) and persistent AF (PersAF). METHODS: A total of 139 patients underwent index CB2-based PVI patients (PAF: n = 105, 76% and PersAF: n = 34, 34%) in two electrophysiology centers. Freeze-cycle duration was 240 s. After successful PVI a bonus freeze-cycle of the same duration was applied in the first 71 patients while the bonus-freeze was omitted in 68 following patients. Three patients (2.2%) were lost to follow-up. RESULTS: After a median follow-up duration of 60 months (interquartile range: 46, 72 months) 74/136 (54.4%) patients remained in stable sinus rhythm (PAF: 62/104, 59.6%; PersAF: 15/32, 46.9%). Significant differences were observed concerning 5-year clinical outcome between PAF and PersAF patients (p = 0.0315). After a mean of 1.32 ± 0.6 procedures (2nd and 3rd procedure by radiofrequency ablation) and a median follow-up duration of 60 (37, 68) months 90/136 (66.2%) patients remained in stable sinus rhythm (PAF: 72/104 (69.2%), PersAF: 21/32 (65.6%), p = 0.0276). For the comparison of bonus-freeze vs no-bonus-freeze protocols no differences were observed (53.5% vs 57.4%, p = 0.650). CONCLUSIONS: The five-year single-procedure success rate for CB2-based PVI was 54.4% and increased to 66.2% following repeat RF-based procedures. No differences were detected comparing bonus-freeze and no-bonus-freeze protocols.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Seguimentos , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
16.
Circ J ; 84(6): 902-910, 2020 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-32307357

RESUMO

BACKGROUND: The second-generation cryoballoon (CB2) has demonstrated high procedural efficacy and convincing clinical success rates for pulmonary vein isolation (PVI). Nevertheless, data on the impact of different ablations protocols on durability are limited. The aim was to comparing the durability of PVI following 3 different ablation strategies in patients with recurrence of atrial fibrillation or atrial tachycardia undergoing repeat procedures.Methods and Results:In 192 patients, a total of 751 PVs were identified. All PVs were successfully isolated during index PVI. Thirty-one out of 192 (16%) patients were treated with a bonus-freeze protocol (group 1), 67/192 (35%) patients with a no bonus-freeze protocol (group 2), and 94/192 (49%) patients with a time-to-effect-guided protocol (group 3). Persistent PVI was documented in 419/751 (55.8%) PVs, and in 41/192 (21%) patients, all PVs were persistently isolated. The total rate of PV reconnection was not significantly different between the groups (P=0.134) and the comparison of individual PVs revealed no differences (P-values for RSPV: 0.424, RIPV: 0.541, LSPV: 0.788, LIPV: 0.346, LCPV: 0.865). The procedure times were significantly reduced by omitting the bonus-freeze and applying individualized application times (group 1: 123.4±31.5 min, group 2: 112.9±39.8 min, group 3: 86.67±28.4 min, P<0.001). CONCLUSIONS: Comparing 3 common ablation protocols, no differences for durable PVI were detected. Procedure times were significantly reduced by omitting the bonus-freeze cycle and by applying individualized application times.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Frequência Cardíaca , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Criocirurgia/efeitos adversos , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Fatores de Risco , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
17.
J Cardiovasc Electrophysiol ; 31(5): 1068-1074, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32128924

RESUMO

AIMS: The current study sought to assess the impact of the utilized energy source during index ablation on long-term clinical outcomes after repeat ablation of atrial fibrillation (AF). Index ablation procedures were either performed using radiofrequency current (RFC) (RFC group) or cryoballoon (CB) ablation (CB group). Repeat ablation was performed by the use of RFC. METHODS: A total of 195 patients (138 RFC group; 57 CB group) with paroxysmal AF were included. All patients had a recurrence of AF following the index ablation procedure. Freedom from AF was estimated with the Kaplan-Meier method. RESULTS: After a 3 years follow-up, the estimated arrhythmia-free survival did not differ between the two groups (RFC group 48% vs CB group 47%, P = .78). During index ablation, procedure times were significantly shorter in the CB group (95 [80, 140] vs 140 [115, 164] minutes, P ≤ .001), whereas fluoroscopy times (16 [11; 22] vs 19 [14; 25] minutes, P = .003), the dose area product (1862 [1203; 2922] vs 3148 [1756; 5888] cGycm2 , P ≤ .001) and the amount of contrast dye (92 ± 32 vs 123 ± 33 mL, P ≤ .001) were significantly lower in the RFC group. During repeat ablation, procedure times were significantly shorter in patients being initially treated with RFC (115 [85; 145] vs 125 [105; 150] minutes, P = .007). There was a trend towards a higher pulmonary vein reconnection rate in the RFC group without meeting statistical significance (P = .074). CONCLUSIONS: In patients with repeat ablation of AF, index RFC or CB ablation are equally effective in terms of freedom from AF. Although CB ablation results in shorter index procedures times, durations of repeat ablation are significantly longer.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Intervalo Livre de Doença , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
18.
Clin Cardiol ; 43(4): 394-400, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32097501

RESUMO

BACKGROUND: The second-generation cryoballoon (CB2) is widely used for pulmonary vein (PV) isolation (PVI) in patients with paroxysmal atrial fibrillation (AF). Recently, the novel fourth-generation CB (CB-Advance PRO) was introduced, incorporating a shortened catheter tip. HYPOTHESIS: The aim of this study was to evaluate the feasibility and acute efficacy of PVI using the CB-Advance PRO. METHODS: A total of 200 consecutive patients were analyzed. Hundred patients who underwent PVI due to symptomatic, drug-refractory AF were treated with the CB-Advance PRO (group I) and were included into this multicenter analysis. A group of 100 patients were treated with the CB2 and acted as controls (group II). RESULTS: In total, 739 of 739 PVs (100%) were successfully isolated. There was a nonsignificant trend in the incidence of online registration of PV signals between both groups (group I: 77.9% vs group II: 71.4%, P = .09). Median time to PVI (time to isolation [TTI]) and mean total freezing time were significantly shorter when using the CB-Advance PRO (group I: 33 [23, 50] vs group II: 40 [26, 60] seconds and group I: 166 ± 29 vs group II: 183 ± 38 seconds, P < .01). In three of 100 (3%) patients of group I and one of 100 (1%) patients of group II, a transient phrenic nerve palsy occurred (P = .62). CONCLUSION: The use of the novel CB-Advance PRO is feasible and associated with a significant reduction in mean TTI and mean total freezing time as compared to the CB2.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Alemanha , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Veias Pulmonares/fisiopatologia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
19.
Circ J ; 83(8): 1653-1659, 2019 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-31257357

RESUMO

BACKGROUND: Second-generation cryoballoon (CB2)-based pulmonary vein isolation (PVI) has demonstrated encouraging results in the treatment of atrial fibrillation (AF). This study sought to assess data on the safety, efficacy and clinical success of CB2-based PVI in patients with heart failure (HF) and reduced ejection fraction (HFrEF).Methods and Results:CB2-based PVI was performed in 551 consecutive patients in 3 highly experienced EP centers. Patients with HF and LVEF ≤40% were included (HFrEF group, n=50/551, 9.1%). Data were compared with propensity score-matched patients without HF and preserved left ventricular EF (LVEF) (n=50, control group). The median LVEF was HFrEF: 37% (35, 40) and control: 55% (55, 55), P<0.0001. Major periprocedural complications were registered in 4/50 (8%, HFrEF group) and 3/50 (6%, control group), P=0.695. The 12-month freedom from AF recurrence was 73.1% (95% confidence interval (CI): 61-88, HFrEF group) and 72.6% (95% CI: 61-87, control group), P=0.25. NYHA class decreased from 2.4±0.8 (baseline) to 1.7±0.8 at 12-month follow-up (P<0.0001). LVEF improved from a median of 37% (35, 40) prior to ablation to a median of 55% (40, 55), P<0.0001. CONCLUSIONS: CB2-based PVI in patients with HFrEF appeared to be safe, was associated with comparable periprocedural complications and showed promising clinical success rates equal to those for patients with preserved LVEF. NYHA class and LVEF significantly improved at 12-month follow-up.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Criocirurgia/instrumentação , Insuficiência Cardíaca/fisiopatologia , Veias Pulmonares/cirurgia , Função Ventricular Esquerda , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Criocirurgia/efeitos adversos , Desenho de Equipamento , Feminino , Alemanha , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Veias Pulmonares/fisiopatologia , Recuperação de Função Fisiológica , Recidiva , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo
20.
J Cardiovasc Electrophysiol ; 30(9): 1436-1442, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31190440

RESUMO

AIMS: We sought to assess (1) clinical outcomes of second-generation cryoballoon (CB) ablation for persistent atrial fibrillation (AF), and (2) the association of baseline and procedural covariates with atrial arrhythmia recurrence (AAR) after ablation. METHODS: A total of 135 patients (63 ± 11 years, 96 men [71%]) with persistent AF underwent CB ablation at three experienced electrophysiology centers. Freedom from AAR was estimated with the Kaplan-Meier method. A Cox proportional-hazards model was used to estimate the effects of baseline and procedural covariates on the likelihood of AAR. RESULTS: Freedom from AAR at 6, 12, and 18 months was estimated at 91% (95% confidence interval [CI] 86%-96%), 75% (95% CI, 67%-83%), and 53% (95% CI, 43%-65%), respectively. The presence of an implantable cardiac device (Hazard ratio [HR] 3.09; 95% CI, 1.37-7.00; P = .007), a left atrial (LA) diameter > 50 mm (HR 1.69; 95% CI, 1.02-2.79; P = .043), and absence of antiarrhythmic drug (AAD) therapy before the ablation procedure (HR 3.12; 95% CI, 1.72-5.64; P < .001) were associated with AAR. A trend toward an increased risk of AAR was revealed for women (HR 1.73; 95% CI, 0.96-3.11; P = .069). CONCLUSIONS: CB ablation for persistent AF resulted in freedom from AAR about that reported for RF ablation. The presence of an implantable cardiac device, LA size, and absence of AAD therapy at baseline were associated with the risk of AAR.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Criocirurgia/efeitos adversos , Criocirurgia/instrumentação , Feminino , Alemanha , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA