Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 15(11): e0242049, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33186361

RESUMO

Islet autoantibodies are predominantly measured by radioassay to facilitate risk assessment and diagnosis of type 1 diabetes. However, the reliance on radioactive components, large sample volumes and limited throughput renders radioassay testing costly and challenging. We developed a multiplex analysis platform based on antibody detection by agglutination-PCR (ADAP) for the sample-sparing measurement of GAD, IA-2 and insulin autoantibodies/antibodies in 1 µL serum. The assay was developed and validated in 7 distinct cohorts (n = 858) with the majority of the cohorts blinded prior to analysis. Measurements from the ADAP assay were compared to radioassay to determine correlation, concordance, agreement, clinical sensitivity and specificity. The average overall agreement between ADAP and radioassay was above 91%. The average clinical sensitivity and specificity were 96% and 97%. In the IASP 2018 workshop, ADAP achieved the highest sensitivity of all assays tested at 95% specificity (AS95) rating for GAD and IA-2 autoantibodies and top-tier performance for insulin autoantibodies. Furthermore, ADAP correctly identified 95% high-risk individuals with two or more autoantibodies by radioassay amongst 39 relatives of T1D patients tested. In conclusion, the new ADAP assay can reliably detect the three cardinal islet autoantibodies/antibodies in 1µL serum with high sensitivity. This novel assay may improve pediatric testing compliance and facilitate easier community-wide screening for islet autoantibodies.


Assuntos
Aglutinação/imunologia , Autoanticorpos/imunologia , Diabetes Mellitus Tipo 1/imunologia , Ilhotas Pancreáticas/imunologia , Adolescente , Adulto , Feminino , Glutamato Descarboxilase/imunologia , Humanos , Anticorpos Anti-Insulina/imunologia , Masculino , Programas de Rastreamento , Reação em Cadeia da Polimerase/métodos , Sensibilidade e Especificidade , Adulto Jovem
2.
J Cell Biol ; 156(3): 543-53, 2002 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-11815633

RESUMO

Approaches with high spatial and temporal resolution are required to understand the regulation of nonmuscle myosin II in vivo. Using fluorescence resonance energy transfer we have produced a novel biosensor allowing simultaneous determination of myosin light chain kinase (MLCK) localization and its [Ca2+]4/calmodulin-binding state in living cells. We observe transient recruitment of diffuse MLCK to stress fibers and its in situ activation before contraction. MLCK is highly active in the lamella of migrating cells, but not at the retracting tail. This unexpected result highlights a potential role for MLCK-mediated myosin contractility in the lamella as a driving force for migration. During cytokinesis, MLCK was enriched at the spindle equator during late metaphase, and was maximally activated just before cleavage furrow constriction. As furrow contraction was completed, active MLCK was redistributed to the poles of the daughter cells. These results show MLCK is a myosin regulator in the lamella and contractile ring, and pinpoints sites where myosin function may be mediated by other kinases.


Assuntos
Técnicas Biossensoriais/métodos , Movimento Celular/fisiologia , Citoesqueleto/metabolismo , Membranas Intracelulares/metabolismo , Quinase de Cadeia Leve de Miosina/metabolismo , Miosinas/metabolismo , Pseudópodes/metabolismo , Animais , Cálcio/metabolismo , Sinalização do Cálcio/fisiologia , Calmodulina/metabolismo , Divisão Celular/fisiologia , Polaridade Celular/fisiologia , Dipodomys , Microscopia de Fluorescência/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA