Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 142
Filtrar
4.
Artigo em Inglês | MEDLINE | ID: mdl-38530098

RESUMO

Objectives: To evaluate trends in botulinum toxin (BTX) industry payments to physicians. Methods: Cross-sectional analysis of nonroyalty, BTX-specific payments made by Allergan (Botox), Ipsen (Dysport), and Merz (Xeomin) to physicians using the 2016-2020 Open Payments Database. Results: Between 2016 and 2020, >$27 million in payments was made for BTX-related activities to dermatologists, neurologists, ophthalmologists, otolaryngologists, and plastic surgeons, with payments ranging from $3.9 million in 2016 to $8.7 million in 2019. 21.7% was paid to dermatologists, 57.5% to neurologists, 5.9% to ophthalmologists, 5.7% to otolaryngologists, and 9.1% to plastic surgeons. Conclusions: Growing amounts are being paid to physicians for BTX-related activities-both medical and aesthetic. Despite the variety of indications for BTX within otolaryngology, otolaryngology payments were overshadowed by other specialties, which may reflect greater BTX utilization in those specialties.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38377584

RESUMO

Background: Many open-access artificial intelligence (AI)-based websites that rate facial attractiveness are available, but none have been compared with human focus group outcomes. Objective: To compare human and AI-based websites scoring of facial attractiveness of adult female white faces. Methods: A 40-photograph database of AI-generated adult, white, female, expressionless, and frontal-view facial images were scored by otolaryngology residents and five AI-based facial rating websites: prettyscale.com, attractivenesstest.com, face-score.com/en, hotchat3000.com, and beautyscoretest.com. Sample t-test and bivariate correlation were performed for statistical analyses. Results: The focus group of 24 otolaryngology residents consisted of 62.5% males and 58.3% white participants. There was a strong positive correlation between average human score and average AI score for each photo (Pearson's correlation 0.84, p < 0.01). The average human raters' scores were significantly lower than the average AI scores (5.0 ± 1.8 vs. 6.9 ± 0.9, p < 0.01). Thirty images (75.0%) had statistically higher scores from the AI websites versus the focus group. On correlation analysis, all AI-based websites individually had scores that positively correlate with the human scores (all p < 0.05). Conclusion: AI-based websites and human focus-group scoring of facial attractiveness of adult white female faces were significantly correlated with the AI ratings biased toward higher values, encouraging their cautious utilization in future research.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38215259

RESUMO

Background: A "boomerang" graft is an end-to-end caudal septal extension graft (SEG) that conforms to the geometry of the anterior septal angle, and avoids septal overlap, unlike a side-to-side SEG. Objective: To compare breathing improvements in rhinoplasty patients receiving boomerang SEGs and patients receiving side-to-side SEGs. Methods: Retrospective cohort analysis of patients undergoing rhinoplasty with either end-to-end boomerang SEG or a side-to-side SEG. Functional outcomes were assessed through the Nasal Obstruction Symptom Evaluation (NOSE) survey. Results: The boomerang SEG cohort had a mean age of 34 years and were 68% female compared with 38 years and 67% female in the side-to-side SEG cohort (p > 0.05). The cohorts did not differ in the proportion of the lateral crural tensioning, spreader graft placement, or history of rhinoplasty. The boomerang cohort demonstrated a 67% reduction in NOSE scores compared with a 70% reduction among the side-to-side SEG cohort (p = 0.14). Men undergoing boomerang graft placement reported significantly less postoperative functional improvement than men undergoing placement of a side-to-side SEG (62% vs. 77%, p = 0.01). Conclusion: Use of a boomerang graft is not likely to negatively affect rhinoplasty functional outcomes when compared with a side-to-side SEG.

8.
Facial Plast Surg ; 40(1): 120-126, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36509105

RESUMO

This study aims to identify the epidemiology and effects of facial fractures on return to play (RTP) in Major League Soccer (MLS) and the English Premier League (EPL). A total of 39 MLS players and 40 EPL players who sustained facial fractures from 2007 to 2019 were identified. Data on player demographics, the injury, and the impact of their injury on RTP were collected. Elbow-to-head was the most common mechanism of injury (20.3%). The most common fracture involved the nasal bone (48.3%). Most players (90%) RTP the same season. Players who sustained nasal fractures missed significantly fewer games (p < 0.001) than those who suffered other craniofacial fractures. Players treated surgically missed significantly more games (3.21 vs. 0.71, p = 0.006) and days (30.1 vs. 8.70, p = 0.002) than those managed nonoperatively. Significantly more EPL players who sustained facial fractures wore headgear upon RTP compared to MLS players (82% vs. 56%, p <0 .01). Most professional soccer players who sustain a facial fracture RTP the same season, but their recovery time can vary depending on the type of fracture, injury management, or injury severity. Our findings can help inform future craniofacial injury management as well as guidelines on player safety and fracture prevention.


Assuntos
Fraturas Cranianas , Futebol , Humanos , Futebol/lesões , Fraturas Cranianas/epidemiologia
9.
Laryngoscope ; 134(2): 651-653, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37300433

RESUMO

Handheld ultrasound devices can be used in revision rhinoplasty to evaluate the calcification of costal rib cartilage that is to be harvested for grafting. This article provides instructions on how to perform this technique. Laryngoscope, 134:651-653, 2024.


Assuntos
Cartilagem Costal , Rinoplastia , Humanos , Cartilagem Costal/transplante , Rinoplastia/métodos , Transplante Autólogo , Coleta de Tecidos e Órgãos , Reoperação/métodos , Estudos Retrospectivos
10.
Plast Reconstr Surg ; 153(2): 334e-347e, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-37163479

RESUMO

BACKGROUND: Current minimally invasive fat reduction modalities use equipment that can cost thousands of U.S. dollars. Electrochemical lipolysis (ECLL), using low-cost battery and electrodes (approximately $10), creates acid/base within fat (width, approximately 3 mm), damaging adipocytes. Longitudinal effects of ECLL have not been studied. In this pilot study, the authors hypothesize that in vivo ECLL induces fat necrosis, decreases adipocyte number/viability, and forms lipid droplets. METHODS: Two female Yorkshire pigs (50 to 60 kg) received ECLL. In pig 1, 10 sites received ECLL, and 10 sites were untreated. In pig 2, 12 sites received ECLL and 12 sites were untreated. For ECLL, two electrodes were inserted into dorsal subcutaneous fat and direct current was applied for 5 minutes. Adverse effects of excessive pain, bleeding, infection, and agitation were monitored. Histology, live-dead (calcein, Hoechst, ethidium homodimer-1), and morphology (Bodipy and Hoechst) assays were performed on day 0 and postprocedure days 1, 2, 7, 14 (pig 1 and pig 2), and 28 (pig 2). Average particle area, fluorescence signal areas, and adipocytes and lipid droplet numbers were compared. RESULTS: No adverse effects occurred. Live-dead assays showed adipocyte death on the anode on days 0 to 7 and the cathode on days 1 to 2 (not significant). Bodipy showed significant adipocyte loss at all sites ( P < 0.001) and lipid droplet formation at the cathode site on day 2 ( P = 0.0046). Histology revealed fat necrosis with significant increases in average particle area at the anode and cathode sites by day 14 (+277.3% change compared with untreated, P < 0.0001; +143.4%, P < 0.0001) and day 28 (+498.6%, P < 0.0001; +354.5%, P < 0.0001). CONCLUSIONS: In vivo ECLL induces fat necrosis in pigs. Further studies are needed to evaluate volumetric fat reduction. CLINICAL RELEVANCE STATEMENT: In vivo ECLL induces adipocyte death and fat necrosis. ECLL has the potential to be utilized in body fat contouring.


Assuntos
Compostos de Boro , Necrose Gordurosa , Lipólise , Feminino , Animais , Suínos , Projetos Piloto , Adipócitos
11.
Otolaryngol Head Neck Surg ; 170(2): 605-609, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37746939

RESUMO

With the widespread adoption of intranasal radiofrequency (RF) devices, our objective was to report national adverse events (AEs) associated with their use. The Food and Drug Administration's Manufacturer and User Facility Device Experience was queried. A total of 24 device-related AEs were reported, 11 (45.8%) for Celon® (Olympus), 3 (12.5%) for Vivaer® (Aerin), 2 (8.3%) for Neuromark® (Neurent), and 8 (33.3%) for Rhinaer® (Aerin). Seven (63.6%) of the Celon®-related complications were related to tissue necrosis (largely user error-related), but 1 (9.1%) episode of pediatric ocular palsy was also reported. Vivaer® complications included synechiae formation, a mucosal perforation, and a case of empty nose syndrome. Of the posterior nasal nerve ablating devices, 9 of 10 AEs were epistaxes, of which 7 (77.8%) required operative intervention. Surgeons should exercise vigilance and tissue-appropriate device settings when utilizing RF devices. Epistaxis and tissue necrosis may occur, as well as more rare, but devastating, complications.


Assuntos
Necrose , Criança , Humanos , Bases de Dados Factuais , Estados Unidos , United States Food and Drug Administration
12.
Laryngoscope ; 133(12): 3370-3377, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37306215

RESUMO

OBJECTIVE: There is little knowledge about the histological organization of facial and costal cartilages in terms of matrix structure and cell morphology. Second harmonic generation (SHG) imaging is a nonlinear imaging technique that capitalizes on signal generation from highly ordered macromolecules such as collagen fibers. The purpose of this study was to use SHG microscopy to image collagen extracellular matrix (ECM) structure, chondrocyte size, and density of these cartilages. STUDY DESIGN: Experimental. METHODS: Surgical remnants of septal, lower lateral, rib, and auricular cartilages were collected following surgery, sectioned into 0.5-1 mm thick samples and fixed to facilitate batch process imaging. A Leica TCS SP8 MP Microscope and multiphoton laser were used to image the specimens. Images were analyzed for cell size, cell density, and collagen fiber directionality patterns using ImageJ. RESULTS: SHG images of septal specimens show mesh-like structure of the ECM. There appears to be a superficial layer, characterized by flattened lacunae and middle zone, marked by circular lacunae clusters, similar to what is observed in articular cartilage. The structure of the ECM depicts a visible orientation perpendicular to the surface of the perichondrium. Cell size and density analysis through ImageJ suggests variety across cartilage types. Directionality analysis indicates that the collagen in the ECM displays preferred direction. CONCLUSION: This study establishes clear extracellular models of facial and costal cartilages. Limitations include heterogeneous cartilage thickness due to processing difficulties. Further studies include automating the cutting process to increase uniformity of tissue thickness and increasing sample size to further validate results. LEVEL OF EVIDENCE: 2 Laryngoscope, 133:3370-3377, 2023.


Assuntos
Cartilagem Articular , Cartilagem Costal , Microscopia de Geração do Segundo Harmônico , Humanos , Cartilagem Articular/anatomia & histologia , Cartilagem Articular/metabolismo , Matriz Extracelular/metabolismo , Colágeno/metabolismo
13.
Quant Imaging Med Surg ; 13(4): 2364-2375, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37064357

RESUMO

Background: The coordination and the directional order of ciliary metachronal waves are the major factors that determine the effectiveness of mucociliary clearance (MCC). Even though metachronal waves play an essential part in immune response, clinical diagnostic tools and imaging techniques that can reliably and efficiently capture their spatial distribution and function are currently limited. Methods: We present label-free high-speed visualization of ciliary metachronal wave propagations in freshly-excised tracheal explants using a spectrally-encoded interferometric microscope over a two-dimensional (2D) plane of 0.5 mm × 0.5 mm at an acquisition rate of 50 frame-per-second. Furthermore, phase-resolved enhanced dynamic (PHRED) analysis of time-series doppler images was performed, where spatial-temporal characteristics of cilia metachronal wave motions are revealed through frequency component analysis and spatial filtering. Results: The PHRED analysis of phase-resolved Doppler (PRD) images offers a capability to distinguish the propagation direction of metachronal waves, and quantitatively assess amplitude and dominant frequency of cilia beating at each spatial location. Compared to the raw PRD images, the phase-resolved dynamic wavefront imaging (PRDWI) method showed the direction and coordination of collective cilia movement more distinctively. Conclusions: The PRDWI technique can have broad application prospects for the diagnosis of human respiratory diseases and evaluation of the curative effect of treatments and open new perspectives in biomedical sciences.

14.
Facial Plast Surg Aesthet Med ; 25(1): 40-41, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35138940

RESUMO

The coronavirus disease 2019 pandemic has led to innovation in the way scientific advancements are disseminated and the structure of physician continuing medical education. With in-person medical conferences and meetings throughout the world impacted by travel restrictions and many geographically confined, virtual teleconferences with exceptional attendance have become an integral part of medical education. Our group has successfully produced >50 virtual educational seminars, including multiple global webinar conferences ranging between 24 and 55 h of continuous lectures each. In this special communication, we discuss some of the challenges we overcame in learning "on the job" and share key elements to successful implementation of long-format virtual teleconference events. We hope our experience will guide future online continuing medical education efforts and assist others in planning their own online initiatives.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Pandemias
15.
Lasers Surg Med ; 55(1): 135-145, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36511512

RESUMO

OBJECTIVES: Traditional fat contouring is now regularly performed using numerous office- based less invasive techniques. However, some limitations of these minimally invasive techniques include high cost or limited selectivity with performing localized contouring and reduction of fat. These shortcomings may potentially be addressed by electrochemical lipolysis (ECLL), a novel approach that involves the insertion of electrodes into tissue followed by application of a direct current (DC) electrical potential. This results in the hydrolysis of tissue water creating active species that lead to fat necrosis and apoptosis. ECLL can be accomplished using a simple voltage-driven system (V-ECLL) or a potential-driven feedback cell (P-ECLL) both leading to water electrolysis and the creation of acid and base in situ. The aim of this study is to determine the long-lasting effects of targeted ECLL in a Yucatan pig model. METHODS: A 5-year-old Yucatan pig was treated with both V-ECLL and P-ECLL in the subcutaneous fat layer using 80:20 platinum:iridium needle electrodes along an 8 cm length. Dosimetry parameters included 5 V V-ECLL for 5, 10, and 20 minutes, and -1.5 V P-ECLL, -2.5 V P-ECLL, -3.5 V P-ECLL for 5 minutes. The pig was assessed for changes in fat reduction over 3 months with digital photography and ultrasound. After euthanasia, tissue sections were harvested and gross pathology and histology were examined. RESULTS: V-ECLL and P-ECLL treatments led to visible fat reduction (12.1%-27.7% and 9.4%-40.8%, respectively) and contour changes across several parameters. An increased reduction of the superficial fat layer occurred with increased dosimetry parameters with an average charge transfer of 12.5, 24.3, and 47.5 C transferred for 5 V V-ECLL for 5, 10, and 20 minutes, respectively, and 2.0, 11.5, and 24.0 C for -1.5 V P-ECLL, -2.5 V P-ECLL, -3.5 V P-ECLL for 5 minutes, respectively. These dose-dependent changes were also evidenced by digital photography, gross pathology, ultrasound imaging, and histology. CONCLUSIONS: ECLL results in selective damage and long-lasting changes to the adipose layer in vivo. These changes are dose-dependent, thus allowing for more precise contouring of target areas. P-ECLL has greater efficiency and control of total charge transfer compared to V-ECLL, suggesting that a low-voltage potentiostat treatment can result in fat apoptosis equivalent to a high-voltage DC system.


Assuntos
Lipectomia , Lipólise , Animais , Suínos , Estudo de Prova de Conceito , Gordura Subcutânea/diagnóstico por imagem , Lipectomia/métodos , Ultrassonografia
17.
Facial Plast Surg Aesthet Med ; 25(4): 318-324, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36201234

RESUMO

Background: Rhinoplasty osteotomes can be sharpened in various ways: professional sharpening or hand sharpening using whetstones or rotary powered devices. Objective: To compare the effectiveness of sharpening osteotomes using various sharpening methods with that of professional sharpening as measured by a custom edge tester. Materials and Methods: We performed repeated serial osteotome impacts on bovine femoral cortical bone. These dull osteotomes were sharpened using preidentified sharpening techniques. Edge morphology was evaluated. Sharpness was tested using a custom mechanical testing platform. Optimized sharpness was achieved with a whetstone sharpening method wherein the osteotome is flipped after every stroke. Results: Seven distinct sharpening methods were tested for sharpness five times each to determine the optimal sharpening method versus professional sharpening (control). The two sharpening methods, 5 (5.51 ± 0.32) and 6 (5.55 ± 0.32), that used this flipping technique were significantly sharper than other methods. Methods 5 (p = 1.0) and 6 (p = 1.0) were the only methods that were not significantly different from control. Conclusion: Single stroke with successively alternating surfaces created the sharpest blades that achieved results similar to professional sharpening.


Assuntos
Rinoplastia , Acidente Vascular Cerebral , Humanos , Animais , Bovinos , Osteotomia , Rinoplastia/métodos
18.
Curr Opin Otolaryngol Head Neck Surg ; 30(4): 226-229, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35774022

RESUMO

PURPOSE OF REVIEW: The COVID-19 pandemic catalyzed the rapid adoption of digital tools and virtual learning platforms by rhinoplasty educators and trainees alike. This review provides an overview of the variety of digital software and web-based tools rhinoplasty educators have adopted and highlights the advantages and potential drawbacks of virtual learning via e-content. RECENT FINDINGS: Medical education including subspecialty surgical training has recently undergone a dramatic digital transformation. Rhinoplasty surgeon-educators have been forced to embrace new digital tools, including videoconferencing, podcasts, virtual simulation and social media to reach and teach trainees. Recognizing the advantages of this new, limitless digital space, rhinoplasty surgeons are also engaging in virtual transcontinental collaboration and distance mentorship. SUMMARY: The dramatic evolution in how clinical educational materials are now digitally created, curated, disseminated and consumed is likely to far outlast the COVID-19 pandemic itself. Rapid, exponential growth of this digital library, however, places increased responsibility on educators to guide trainees towards evidence-based and state-of-the-art content.


Assuntos
COVID-19 , Educação a Distância , Educação Médica , Rinoplastia , COVID-19/epidemiologia , Humanos , Pandemias
20.
Lasers Surg Med ; 54(1): 157-169, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34412154

RESUMO

OBJECTIVES: Minimally invasive fat sculpting techniques are becoming more widespread with the development of office-based devices and therapies. Electrochemical lipolysis (ECLL) is a needle-based technology that uses direct current (DC) to electrolyze tissue water creating acid and base in situ. In turn, fat is saponified and adipocyte cell membrane lysis occurs. The electrolysis of water can be accomplished using a simple open-loop circuit (V-ECLL) or by incorporating a feedback control circuit using a potentiostat (P-ECLL). A potentiostat utilizes an operational amplifier with negative feedback to allow users to precisely control voltage at specific electrodes. To date, the variation between the two approaches has not been studied. The aim of this study was to assess current and charge transfer variation and lipolytic effect created by the two approaches in an in vivo porcine model. METHODS: Charge transfer measurements from ex vivo V-ECLL and P-ECLL treated porcine skin and fat were recorded at -1 V P-ECLL, -2 V P-ECLL, -3 V P-ECLL, and -5 V V-ECLL each for 5 min to guide dosimetry parameters for in vivo studies. In follow-up in vivo studies, a sedated female Yorkshire pig was treated with both V-ECLL and P-ECLL across the dorsal surface over a range of dosimetry parameters, including -1.5 V P-ECLL, -2.5 V P-ECLL, -3.5 V P-ECLL, and 5 V V-ECLL each treated for 5 min. Serial biopsies were performed at baseline before treatment, 1, 2, 7, 14, and 28 days after treatment. Tissue was examined using fluorescence microscopy and histology to compare the effects of the two ECLL approaches. RESULTS: Both V-ECLL and P-ECLL treatments induced in-vivo fat necrosis evident by adipocyte membrane lysis, adipocyte denuclearization, and an acute inflammatory response across a 28-day longitudinal study. However, -1.5 V P-ECLL produced a smaller spatial necrotic effect compared to 5 V V-ECLL. In addition, 5 V V-ECLL produced a comparable necrotic effect to that of -2.5 V and -3.5 V P-ECLL. CONCLUSIONS: V-ECLL and P-ECLL at the aforementioned dosimetry parameters both achieved fat necrosis by adipocyte membrane lysis and denuclearization. The -2.5 V and -3.5 V P-ECLL treatments created spatially similar fat necrotic effects when compared to the 5 V V-ECLL treatment. Quantitatively, total charge transfer between dosimetry parameters suggests that -2.5 V P-ECLL and 5 V V-ECLL produce comparable electrochemical reactions. Such findings suggest that a low-voltage closed-loop potentiostat-based system is capable of inducing fat necrosis to a similar extent compared to that of a higher voltage direct current system.


Assuntos
Adipócitos , Lipólise , Animais , Estudos de Viabilidade , Retroalimentação , Feminino , Estudos Longitudinais , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA