Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Br J Ophthalmol ; 105(4): 514-520, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32606078

RESUMO

AIMS: To compare the intraocular pressure (IOP) lowering effect and safety profile between pattern scanning laser trabeculoplasty (PSLT) and selective laser trabeculoplasty (SLT) in patients with primary open-angle glaucoma (POAG) or ocular hypertension (OHT) over a 12-month follow-up. METHODS: 132 patients with POAG or OHT were consecutively enrolled and randomised (1:1) to receive PSLT (n=65) or SLT (n=67) in a single centre. IOP was measured before and then on 1 day, 1 week, 1, 3, 6, 9 and 12 months after PSLT/SLT. The primary outcome measure was the proportion of patients with ≥20% IOP reduction at 12 months without IOP-lowering medications (complete success). RESULTS: The mean baseline IOP was 21.2±4.1 mm Hg for eyes randomised to PSLT and 21.3±4.7 mm Hg for eyes randomised to SLT (p=0.898). At 12 months, the IOP was 18.3±3.1 and 17.8±3.4 mm Hg, respectively (p=0.402). IOP measurements were comparable between the groups over 12 months (overall mean difference 0.4 mm Hg, 95% CI: -0.5 to 1.3 mm Hg). 15.4% of PSLT-treated and 25.4% of SLT-treated patients achieved treatment success (difference: 10.0%, 95% CI: -3.6 to 23.6) (p=0.155), respectively. A higher baseline IOP and a greater percentage of IOP reduction at day 1 were associated with a greater percentage of IOP reduction at 12 months (p<0.001). There were no significant differences in visual field mean deviation, average retinal nerve fibre layer thickness, corneal endothelial cell count and visual acuity between the treatment groups at the baseline and 12-month follow-up (p≥0.062). CONCLUSIONS: PSLT was not superior to SLT in terms of safety and IOP-lowering efficacy in patients with POAG or OHT. TRIAL REGISTRATION NUMBER: The clinical trial was registered in the Centre for Research and Biostatistics Clinical Trials Registry, the Chinese University of Hong Kong (Identifier CUHK_CCT00407). The full trial protocol can be accessed from the authors on request.


Assuntos
Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular/fisiologia , Terapia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Hipertensão Ocular/cirurgia , Trabeculectomia/métodos , Acuidade Visual , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Campos Visuais/fisiologia
2.
J Glaucoma ; 27(8): 703-710, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29870431

RESUMO

PURPOSE: To determine the demographic, ocular, and systemic factors associated with long-term intraocular pressure (IOP) fluctuation in primary angle closure disease (PACD). METHODS: This prospective cohort study included 422 PACD eyes from 269 Chinese patients, including 274 primary angle closure glaucoma (PACG) eyes and 152 primary angle closure/primary angle closure suspect (PAC/PACS) eyes. Long-term IOP fluctuation defined as the SD of all IOP measurements over 2 years (at least 5 measurements in total). Chinese patients with PACD were recruited and followed up 3 monthly. Eyes with IOP-lowering surgery or lens extraction performed within the 2-year study period were excluded. Patient demographics, received treatments, ocular biometry, retinal nerve fiber layer thickness, and systemic factors (eg, hypertension, smoking) were evaluated. Generalized estimating equations adjusting for inter-eye correlation were used to determine the associations. RESULTS: Eyes with PACG had significantly higher IOP fluctuation than PAC/PACS (2.4±1.2 versus 2.1±0.9 mm Hg; P=0.04). In the multivariate analysis with PACG eyes, higher baseline IOP (P<0.001), greater number of IOP-lowering medications (P<0.001), previous trabeculectomy (P=0.002), and current smoking (P=0.03) were significantly associated with larger IOP fluctuation, whereas diabetes mellitus was associated with lower IOP fluctuation (P=0.03). Among PAC/PACS eyes, younger age group (P<0.001), male sex (P=0.002), and higher baseline IOP (P<0.001) were significantly associated with larger IOP fluctuation. CONCLUSIONS: PACG eyes have greater IOP fluctuation than PAC/PACS eyes. Certain demographic, ocular, and systemic factors are associated with IOP fluctuation in PACD eyes.


Assuntos
Glaucoma de Ângulo Fechado/fisiopatologia , Pressão Intraocular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/uso terapêutico , Biometria , Feminino , Seguimentos , Glaucoma de Ângulo Fechado/tratamento farmacológico , Glaucoma de Ângulo Fechado/cirurgia , Humanos , Iridectomia/métodos , Iris/cirurgia , Terapia a Laser/métodos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tonometria Ocular , Trabeculectomia
3.
Surv Ophthalmol ; 60(1): 36-50, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25113610

RESUMO

Selective laser trabeculoplasty (SLT) is a relatively new type of laser used in treating open-angle glaucoma (OAG) and is reported to be equally efficacious to a first-line medication and argon laser trabeculoplasty (ALT). We summarize available evidence for considering SLT as an alternative treatment in OAG through systematic review and meta-analysis. Among OAG patients who range from newly diagnosed to those on maximally tolerated medical therapy, SLT results in a 6.9-35.9% intraocular pressure (IOP) reduction. Complications are rare and include an IOP spike requiring surgery, persistent macular edema, and corneal haze and thinning. Meta-analysis of randomized, controlled trials shows that SLT is non-inferior to ALT and medication in IOP reduction and also in achieving treatment success. Number of medications reduction is similar between SLT and ALT. More robust evidence is needed to determine its efficacy as a repeated procedure.


Assuntos
Glaucoma de Ângulo Aberto/cirurgia , Terapia a Laser/métodos , Malha Trabecular/cirurgia , Trabeculectomia/métodos , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Malha Trabecular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA