Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Vasc Surg ; 76(6): 1520-1526, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35714893

RESUMO

OBJECTIVE: Volume and quality benchmarks for open abdominal aortic surgery and particularly open aortic aneurysm repair (OAR) in the endovascular era are guided by the Society for Vascular Surgery guidelines, but the Vascular Quality Initiative (VQI) OAR module fails to capture the full spectrum of complex OAR. We hypothesized that VQI-ineligible complex OAR would be the dominant form of open repairs performed at a VQI-participating tertiary center. METHODS: All OAR cases performed at a single tertiary care center from 2007 to 2020 were reviewed. The VQI OAR criteria were applied with exclusions (non-VQI) defined as concomitant renal bypass, clamping above the superior mesenteric artery or celiac artery, repairs performed for trauma, anastomotic aneurysm, isolated iliac aneurysm, or infected aneurysms. Linear regression was used to assess temporal trends. RESULTS: Among a total of 481 open abdominal aortic operations, 355 (74%) were OAR. The average annual OAR volume remained stable over 14 years (25 ± 6; P = .46). Non-VQI OAR comprised 54% of all cases and persisted over time (R2 = 0.047, P = .46). Supraceliac clamping (35%) was often necessary. The proportion of endograft explantation cases significantly increased over time from 4% in 2007 to 20% in 2019 (P = .01). Infectious indications represented 20% (n = 70) of cases. Visceral branch grafts were performed in 16% of all cases. OAR for ruptured aneurysm constituted 10% of cases. Thirty-day mortality was significantly higher in non-VQI vs VQI-eligible OAR cases (10% vs 4%; P = .04). CONCLUSIONS: Complex OAR comprises a majority of OAR cases in a contemporary tertiary referral hospital, yet these cases are not accounted for in the VQI. Creation of a "complex OAR" VQI module would capture these cases in a quality-driven national registry and help to better inform benchmarks for volume and outcomes in aortic surgery.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Fatores de Risco , Resultado do Tratamento , Fatores de Tempo , Estudos Retrospectivos , Implante de Prótese Vascular/efeitos adversos , Complicações Pós-Operatórias/cirurgia
2.
Vasc Endovascular Surg ; 54(1): 75-79, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31506016

RESUMO

Brachial artery aneurysms and arteriovenous malformations (AVM) are limb-threatening vascular anomalies. This patient presented with a bilobed brachial artery aneurysm in the antecubital fossa proximally to an AVM arising from the dorsal interosseous and ulnar arteries that had been treated with endovascular embolization, leaving the hand solely supplied by the radial artery. The aneurysm continued to increase in size and imaging revealed concomitant thrombus. A femoral vein interposition graft was used to repair the aneurysm, and postoperatively, the patient retained full left arm function.


Assuntos
Aneurisma/cirurgia , Malformações Arteriovenosas/complicações , Artéria Braquial/cirurgia , Veia Femoral/transplante , Artéria Ulnar/anormalidades , Adolescente , Aneurisma/complicações , Aneurisma/diagnóstico por imagem , Aneurisma/fisiopatologia , Malformações Arteriovenosas/diagnóstico por imagem , Malformações Arteriovenosas/terapia , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/fisiopatologia , Embolização Terapêutica , Feminino , Humanos , Resultado do Tratamento , Artéria Ulnar/diagnóstico por imagem , Grau de Desobstrução Vascular
3.
Curr Opin Biotechnol ; 23(5): 810-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22444525

RESUMO

Human pluripotent stem cell (hPSC) differentiation aims to mimic development using growth factors or small molecules in a time-dependent and dose-dependent manner. However, the cell types produced using this approach are predominantly fetal-like in phenotype and function, limiting their use in regenerative medicine. This is particularly true in current efforts to produce pancreatic beta cells, wherein robust pancreatic progenitor maturation can only be accomplished upon transplantation into mice. Recent studies have suggested that hPSC-derived cells are capable of self-organizing in vitro, revealing a new paradigm for creating mature cells and tissues. Tissue engineering strategies that provide subtle and dynamic signals to developmentally naïve cells may be applied to mimic in vitro the self-organization aspects of pancreatic development.


Assuntos
Diferenciação Celular , Células-Tronco Pluripotentes/citologia , Engenharia Tecidual/métodos , Animais , Movimento Celular , Endotélio/citologia , Endotélio/metabolismo , Células Epiteliais/citologia , Células Epiteliais/metabolismo , Gastrulação , Humanos , Células Secretoras de Insulina/citologia , Mesoderma/citologia , Mesoderma/metabolismo , Pâncreas/citologia , Pâncreas/metabolismo , Medicina Regenerativa
4.
Phys Med Biol ; 53(18): 5093-106, 2008 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-18723925

RESUMO

This study aims to quantify the effects of target motion and resultant motion artifacts in planning and megavoltage CT (MVCT) studies on the automatic registration processes of helical tomotherapy. Clinical and experimental data were used to derive an action level for patient repositioning on helical tomotherapy. Planning CT studies of a respiratory motion phantom were acquired using conventional and four-dimensional CT (4D CT) techniques. MVCT studies were acquired on helical tomotherapy in the presence and absence of target motion and were registered with different planning CT studies. The residual errors of the registration process were calculated from the registration values to quantify the ability of the process to detect 5 or 10 mm translations of the phantom in two directions. Twenty-seven registration combinations of MVCT inter-slice spacing, technique and resolution were investigated. The residual errors were used as an estimate of the localization error of the registration process, and the accuracy of couch repositioning was determined from couch position measurements during 866 treatment fractions. These two parameters were used to calculate the action level for patient repositioning on helical tomotherapy. Automatic registration of an MVCT study with 0% breathing phase, average intensity and maximum intensity 4D CT projections did not differ from that of an MVCT study with a conventional planning CT. Motion artifacts in the MVCT or planning CT studies changed the accuracy of the automatic registration process by less than 2.0%. The action level for patient repositioning using MVCT studies of 6 mm inter-slice spacing was determined to be 0.7, 1.1 and 0.6 mm in the x-, y- and z-directions, respectively. These action levels have the greatest effect on treatments for disease sites in the brain.


Assuntos
Algoritmos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Movimento (Física) , Imagens de Fantasmas , Radioterapia Assistida por Computador/instrumentação
5.
Med Dosim ; 33(1): 78-80, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18262127

RESUMO

Physiologic variations in ventricular volumes could have important implications for treating patients with peri-ventricular brain tumors, yet no data exist in the literature addressing this issue. Daily megavoltage computed tomography (CT) scans in a patient with neurocytoma receiving fractionated radiation revealed minimal changes, suggesting that margins accounting for ventricular deformation are not necessary.


Assuntos
Neoplasias do Ventrículo Cerebral/radioterapia , Neurocitoma/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Adulto , Elasticidade , Humanos , Masculino , Neurocitoma/fisiopatologia , Tamanho do Órgão , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Int J Radiat Oncol Biol Phys ; 69(4): 1316-22, 2007 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-17967322

RESUMO

PURPOSE: To evaluate gross tumor volume (GTV) changes for patients with non-small-cell lung cancer by using daily megavoltage (MV) computed tomography (CT) studies acquired before each treatment fraction on helical tomotherapy and to relate the potential benefit of adaptive image-guided radiotherapy to changes in GTV. METHODS AND MATERIALS: Seventeen patients were prescribed 30 fractions of radiotherapy on helical tomotherapy for non-small-cell lung cancer at London Regional Cancer Program from Dec 2005 to March 2007. The GTV was contoured on the daily MVCT studies of each patient. Adapted plans were created using merged MVCT-kilovoltage CT image sets to investigate the advantages of replanning for patients with differing GTV regression characteristics. RESULTS: Average GTV change observed over 30 fractions was -38%, ranging from -12 to -87%. No significant correlation was observed between GTV change and patient's physical or tumor features. Patterns of GTV changes in the 17 patients could be divided broadly into three groups with distinctive potential for benefit from adaptive planning. CONCLUSIONS: Changes in GTV are difficult to predict quantitatively based on patient or tumor characteristics. If changes occur, there are points in time during the treatment course when it may be appropriate to adapt the plan to improve sparing of normal tissues. If GTV decreases by greater than 30% at any point in the first 20 fractions of treatment, adaptive planning is appropriate to further improve the therapeutic ratio.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada Espiral , Carga Tumoral , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Fracionamento da Dose de Radiação , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Masculino , Pessoa de Meia-Idade
7.
Phys Med Biol ; 52(15): N345-54, 2007 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-17634636

RESUMO

This study aims to investigate the settings that provide optimum registration accuracy when registering megavoltage CT (MVCT) studies acquired on tomotherapy with planning kilovoltage CT (kVCT) studies of patients with lung cancer. For each experiment, the systematic difference between the actual and planned positions of the thorax phantom was determined by setting the phantom up at the planning isocenter, generating and registering an MVCT study. The phantom was translated by 5 or 10 mm, MVCT scanned, and registration was performed again. A root-mean-square equation that calculated the residual error of the registration based on the known shift and systematic difference was used to assess the accuracy of the registration process. The phantom study results for 18 combinations of different MVCT/kVCT registration options are presented and compared to clinical registration data from 17 lung cancer patients. MVCT studies acquired with coarse (6 mm), normal (4 mm) and fine (2 mm) slice spacings could all be registered with similar residual errors. No specific combination of resolution and fusion selection technique resulted in a lower residual error. A scan length of 6 cm with any slice spacing registered with the full image fusion selection technique and fine resolution will result in a low residual error most of the time. On average, large corrections made manually by clinicians to the automatic registration values are infrequent. Small manual corrections within the residual error averages of the registration process occur, but their impact on the average patient position is small. Registrations using the full image fusion selection technique and fine resolution of 6 cm MVCT scans with coarse slices have a low residual error, and this strategy can be clinically used for lung cancer patients treated on tomotherapy. Automatic registration values are accurate on average, and a quick verification on a sagittal MVCT slice should be enough to detect registration outliers.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Radiografia Torácica/métodos , Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Phys Med Biol ; 52(8): N185-93, 2007 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-17404453

RESUMO

This study aims to determine the settings that provide the optimal clinical accuracy and consistency for the registration of megavoltage CT (MVCT) with planning kilovoltage CT image sets on the Hi-ART tomotherapy system. The systematic offset between the MVCT and the planning kVCT was determined by registration of multiple MVCT scans of a head phantom aligned with the planning isocentre. Residual error vector lengths and components were used to quantify the alignment quality for the phantom shifted by 5 mm in different directions obtained by all 27 possible combinations of MVCT inter-slice spacing, registration techniques and resolution. MVCT scans with normal slices are superior to coarse slices for registration of shifts in the superior-inferior, lateral and anterior-posterior directions. Decreasing the scan length has no detrimental effect on registration accuracy as long as the scan lengths are larger than 24 mm. In the case of bone technique and fine resolution, normal and fine MVCT scan slice spacing options give similar accuracy, so normal mode is preferable due to shorter procedure and less delivered dose required for patient set-up. A superior-inferior field length of 24-30 mm, normal slice spacing, bone technique, and fine resolution is the optimum set of registration settings for MVCT scans of a Rando head phantom acquired with the Hi-ART tomotherapy system, provided the registration shifts are less than 5 mm.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Intensificação de Imagem Radiográfica/métodos , Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Técnica de Subtração , Tomografia Computadorizada Espiral/métodos , Humanos , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/métodos
SELEÇÃO DE REFERÊNCIAS