Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cancer Control ; 30: 10732748231153775, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36705261

RESUMO

BACKGROUND: Technetium-99m-labeled Tilmanocept, a multivalent mannose, is readily internalized by the CD206 surface receptor on macrophages and dendritic cells which are abundantly present in lymph nodes. We want to examine the drainage patterns of Technetium-99m-labeled Tilmanocept to sentinel lymph nodes (SLNs) in melanoma patients following the 10% rule. METHODS: Multi-center retrospective review of patients with cutaneous melanoma undergoing SLN biopsy using Technetium-99m-labeled Tilmanocept between 2008 and 2014 was conducted. Statistical methods were used for data analyses. RESULTS: Of the 564 patients (mean age of 60.3 and 62% male) with preoperative lymphoscintigraphy showing at least one SLN, several primary tumor sites were included: 27% head/neck, 33% trunk, 21% upper extremity and 19% lower extremity. For the head/neck primary site, 36.5% of patients had multiple draining basins; for the trunk site, 36.4% of patients; for the upper extremity site, 13% of patients; and for the lower extremity, 27.4% of patients. A median of 3 (range 1-18) SLNs were identified and resected. Overall, 78% of patients had >1 SLN identified by Technetium-99m-labeled Tilmanocept. In a multivariate model, patients with >1 SLN were significantly associated with age, Breslow depth, tumor location and higher AJCC tumor stage. A total of 17.7% of patients (100/564) had a positive SLN identified. A total of 145 positive SLNs were identified out of 1,812 SLNs with a positive SLN rate of 8%. Positive SLN status was significantly associated with younger age, greater Breslow depth, mitosis rate, higher AJCC tumor stage, presence of ulceration and angiolymphatic invasion. CONCLUSIONS: Using the 10% rule, Technetium-99m-labeled Tilmanocept detects multiple SLNs in most melanoma patients.


Assuntos
Melanoma , Linfonodo Sentinela , Neoplasias Cutâneas , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/cirurgia , Linfonodo Sentinela/patologia , Linfocintigrafia/métodos , Melanoma/diagnóstico por imagem , Melanoma/cirurgia , Melanoma/patologia , Biópsia de Linfonodo Sentinela/métodos , Compostos Radiofarmacêuticos , Pentetato de Tecnécio Tc 99m , Tecnécio , Metástase Linfática/patologia , Neoplasias Cutâneas/diagnóstico por imagem , Neoplasias Cutâneas/cirurgia , Neoplasias Cutâneas/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/cirurgia , Linfonodos/patologia
2.
Cancer Biother Radiopharm ; 37(1): 11-16, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35021863

RESUMO

Background: Liver metastases from uveal melanoma carry a very poor prognosis. Hepatic artery infusions with Yttrium-90 (90Y) resin microspheres have some activity in this disease, and radiation and immunotherapy may be synergistic. The primary objective of this study was to determine the safety and tolerability of sequential 90Y resin microspheres and immunotherapy with ipilimumab and nivolumab in metastatic uveal melanoma. Materials and Methods: Twenty-six patients with uveal melanoma with hepatic metastases were entered into a pilot study. Treatment consisted of two infusions of 90Y resin microspheres, one to each lobe of the liver, followed in 2-4 weeks by immunotherapy with ipilimumab and nivolumab every 3 weeks for four doses, then maintenance immunotherapy with nivolumab alone. Results: Initial dosing of both 90Y and immunotherapy resulted in excessive toxicity. With decreasing the dosage of 90Y to limit the normal liver dose to 35Gy and lowering the ipilimumab dose to 1 mg/kg, the toxicity was tolerable, with no apparent change in efficacy. There was one complete and four confirmed partial responses, for an objective response rate of 20% and a disease control rate of 68%. The median progression-free survival was 5.5 months (95% confidence interval [CI]: 1.3-9.7 months), with a median overall survival of 15 months (95% CI: 9.7-20.1 months). Conclusions: With dose reductions, sequential therapy with 90Y and immunotherapy with ipilimumab and nivolumab is safe and tolerable, and has activity in metastatic uveal melanoma. These results justify a controlled trial to demonstrate whether 90Y resin microspheres add to the utility of combination immunotherapy in this disease. Clinical Trial Registration number: NCT02913417.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica , Nivolumabe , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Humanos , Imunoterapia , Ipilimumab/efeitos adversos , Fígado , Melanoma , Microesferas , Nivolumabe/efeitos adversos , Projetos Piloto , Neoplasias Uveais , Radioisótopos de Ítrio
3.
Acad Radiol ; 9(11): 1305-21, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12449363

RESUMO

Dual-modality imaging is a technique in which computed tomography (CT) or magnetic resonance imaging is combined with positron emission tomography or single-photon emission CT to acquire structural and functional images with an integated system. The data are acquired in a single procedure; the patient remains on the scanner table while undergoing both x-ray and radionuclide studies to facilitate correlation between the structural and functional images. The resulting data can aid in localization, enabling more specific diagnosis than can be obtained with a conventional imaging study. In addition, the anatomic information can be used to compensate the correlated radionuclide data for physical perturbations such as photon attenuation, scatter radiation, and partial volume errors. Thus, dual-modality imaging provides a priori information that can improve both the visual quality and the quantitative accuracy of the radionuclide images. Dual-modality imaging systems are also being developed for biologic research involving small animals. Small-animal dual-modality systems offer advantages for measurements that currently are performed invasively with autoradiography and tissue sampling. By acquiring data noninvasively, dual-modality imaging permits serial studies in a single animal, enables measurements to be performed with fewer animals, and improves the statistical quality of the data.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Cintilografia/instrumentação , Integração de Sistemas , Tomografia Computadorizada por Raios X/instrumentação , Animais , Desenho de Equipamento , Cardiopatias/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem , Fisiologia , Cintilografia/métodos , Tomografia Computadorizada de Emissão/instrumentação , Tomografia Computadorizada de Emissão/métodos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA