Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Assunto principal
Intervalo de ano de publicação
1.
EJNMMI Phys ; 11(1): 23, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38441830

RESUMO

PURPOSE: This study aimed to evaluate the clinical feasibility of early 30-minute dynamic 2-deoxy-2-[18F]fluoro-D-glucose (18F-FDG) positron emission tomography (PET) scanning protocol for patients with lung lesions in comparison to the standard 65-minute dynamic FDG-PET scanning as a reference. METHODS: Dynamic 18F-FDG PET images of 146 patients with 181 lung lesions (including 146 lesions confirmed by histology) were analyzed in this prospective study. Dynamic images were reconstructed into 28 frames with a specific temporal division protocol for the scan data acquired 65 min post-injection. Ki images and quantitative parameters Ki based on two different acquisition durations [the first 30 min (Ki-30 min) and 65 min (Ki-65 min)] were obtained by applying the irreversible two-tissue compartment model using in-house Matlab software. The two acquisition durations were compared for Ki image quality (including visual score analysis and number of lesions detected) and Ki value (including accuracy of Ki, the value of differential diagnosis of lung lesions and prediction of PD-L1 status) by Wilcoxon's rank sum test, Spearman's rank correlation analysis, receiver operating characteristic (ROC) curve, and the DeLong test. The significant testing level (alpha) was set to 0.05. RESULTS: The quality of the Ki-30 min images was not significantly different from the Ki-65 min images based on visual score analysis (P > 0.05). In terms of Ki value, among 181 lesions, Ki-65 min was statistically higher than Ki-30 min (0.027 ± 0.017 ml/g/min vs. 0.026 ± 0.018 ml/g/min, P < 0.05), while a very high correlation was obtained between Ki-65 min and Ki-30 min (r = 0.977, P < 0.05). In the differential diagnosis of lung lesions, ROC analysis was performed on 146 histologically confirmed lesions, the area under the curve (AUC) of Ki-65 min, Ki-30 min, and SUVmax was 0.816, 0.816, and 0.709, respectively. According to the Delong test, no significant differences in the diagnostic accuracies were found between Ki-65 min and Ki-30 min (P > 0.05), while the diagnostic accuracies of Ki-65 min and Ki-30 min were both significantly higher than that of SUVmax (P < 0.05). In 73 (NSCLC) lesions with definite PD-L1 expression results, the Ki-65 min, Ki-30 min, and SUVmax in PD-L1 positivity were significantly higher than that in PD-L1 negativity (P < 0.05). And no significant differences in predicting PD-L1 positivity were found among Ki-65 min, Ki-30 min, and SUVmax (AUC = 0.704, 0.695, and 0.737, respectively, P > 0.05), according to the results of ROC analysis and Delong test. CONCLUSIONS: This study indicates that an early 30-minute dynamic FDG-PET acquisition appears to be sufficient to provide quantitative images with good-quality and accurate Ki values for the assessment of lung lesions and prediction of PD-L1 expression. Protocols with a shortened early 30-minute acquisition time may be considered for patients who have difficulty with prolonged acquisitions to improve the efficiency of clinical acquisitions.

2.
Front Oncol ; 13: 1205379, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38023132

RESUMO

Objective: To investigate the diagnostic value of the maximum standard uptake value (SUVmax) of quantitative single-photon emission computed tomography/computed tomography (SPECT/CT) in solitary undetermined bone lesions. Methods: In Part I, retrospective study, 167 untreated patients with extra-skeletal malignant tumors by pathology were consecutively enrolled for staging with Tc-99m methyl-diphosphonate (99mTc-MDP) whole-body bone scan (WBS) and quantitative SPECT/CT, and a total of 396 bone lesions with abnormal radioactivity concentration in 167 patients were included from April 2019 to September 2020. The differences in SUVmax among the benign bone lesions, malignant bone lesions, and normal vertebrae were analyzed. The receiver operating characteristic (ROC) curve and cutoff value of SUVmax were obtained. Part II, prospective study, 49 solitary undetermined bone lesions in SPECT/CT in 49 untreated patients with extra-skeletal malignant tumors were enrolled from October 2020 to August 2022. The diagnostic efficacy of SUVmax in solitary undetermined bone lesions was assessed. The final diagnosis was based on follow-up imaging (CT, MRI, or 2-deoxy-2-[18F]fluoro-D-glucose-positron emission tomography/computed tomography) for at least 12 months. Results: In Part I, a total of 156 malignant and 240 benign bone lesions was determined; the SUVmax of malignant lesions (26.49 ± 12.63) was significantly higher than those of benign lesions (13.92 ± 7.16) and normal vertebrae (6.97 ± 1.52) (P = 0.00). The diagnostic efficiency of the SUVmax of quantitative SPECT/CT revealed a sensitivity of 75.00% and a specificity of 81.70% at a cutoff value of 18.07. In Part II, 17 malignant and 32 benign lesions were determined. Using SUVmax ≥18.07 as a diagnostic criterion of malignancy, it has a sensitivity of 82.35%, a specificity of 93.75%, and an accuracy of 89.80%. Conclusion: The SUVmax of quantitative SPECT/CT is valuable in evaluating solitary undetermined bone lesions. Using a cutoff SUVmax value of 18.07, quantitative SPECT/CT demonstrated high sensitivity, specificity, and accuracy in differentiating malignant from benign bone lesions.

3.
ACS Appl Mater Interfaces ; 10(29): 24349-24360, 2018 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-29979028

RESUMO

A series of surfactant-like peptides have been designed for inducing DNA condensation, which are all comprised of the same set of amino acids in different sequences. Results from experiments and molecular dynamics simulations show that the peptide's self-assembly and DNA-interaction behaviors can be well manipulated through sequence variation. With optimized pairing modes between the ß-sheets, the peptide of I3V3A3G3K3 can induce efficient DNA condensation into virus-mimicking structures. The condensation involves two steps; the peptide molecules first bind onto the DNA chain through electrostatic interactions and then self-associate into ß-sheets under hydrophobic interactions and hydrogen bonding. In such condensates, the peptide ß-sheets act as scaffolds to assist the ordered arrangement of DNA, mimicking the very nature of the virus capsid in helping DNA packaging. Such a hierarchy affords an extremely stable structure to attain the highly condensed state and protect DNA against enzymatic degradation. Moreover, the condensate size can be well tuned by the DNA length. The condensates with smaller sizes and narrow size distribution can deliver DNA efficiently into cells. The study helps not only for probing into the DNA packaging mechanism in virus but also delineating the role of peptide self-assembly in DNA condensation, which may lead to development of peptide-based gene vectors for therapeutic applications.


Assuntos
Nanoestruturas , DNA , Ligação de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas , Peptídeos , Estrutura Secundária de Proteína
4.
J Phys Chem B ; 114(15): 4955-63, 2010 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-20349930

RESUMO

Molecular dynamics simulation has been adopted in investigation of different glass transition behaviors of the bulk and the freestanding thin films (about 8 nm) of atactic polypropylene (a-PP). For characterization of glass transition temperature (T(g)) of above systems, both the specific volume and the local conformational transition rate of the systems were examined. The T(g) characterization from the local conformational transition rate of polymer chains was recently developed. Our simulation results show that the films have lower T(g) than the bulk, and the descent of T(g) is in a range of 30 approximately 10 K. These are consistent with experiments. a-PP chain consists of meso-dyad and racemic-dyad, the above results are obtained from both dyads. Individual contribution of the stereoregular dyads to the conformational transition rate was further studied. It was revealed that T(g) obtained singly from the meso-dyads was almost the same with T(g) individually from the racemic-dyads, although the racemic-dyads have much lower transition rate and higher transition barrier than the meso-dyads. In the present study, the reason for the thin films having lower T(g) than the bulk is attributed to the novel behavior that the films have lower transition rate and higher barrier than the bulk when it is below T(g). Such behavior was discussed according to the "coupling rotation" of the dihedrals, which depends on the increase of free volume and the inhibition of kinetic energy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA