Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Lasers Med Sci ; 38(1): 14, 2022 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-36547739

RESUMO

The objective of the study is to observe the changes in the effective optical zone (EOZ) after small incision lenticule extraction (SMILE) and explore possible correlations with some influencing factors. In total, 133 eyes after SMILE were divided into the mild to moderate myopia group (- 1.75 D to - 5.75 D, 70 eyes) and the high myopia group (- 6.00 D to - 9.50 D, 63 eyes). The postoperative EOZ was calculated by utilizing the corneal tangential curvature map. Changes in EOZ (△-OZ) were monitored and compared between the two groups. Pearson correlation analysis was conducted to determine the correlation between △-OZ and corneal high-order wavefront aberrations. Multicollinearity analysis and ridge regression analysis were performed to assess the correlation between △-OZ and some corneal parameters. After SMILE, the horizontal EOZ (H-EOZ), vertical EOZ (V-EOZ), and average EOZ (A-EOZ) were significantly smaller than the programmed optical zone (POZ) in both groups (p < 0.05). The difference between V-EOZ and POZ (△V-OZ) and the difference between A-EOZ and POZ (△A-OZ) showed more significant changes in the high myopia group than in the mild to moderate myopia group, and △V-OZ was significantly larger than the difference between H-EOZ and POZ (△H-OZ) in the high myopia group. In both groups, the total high-order aberration (T-HOA) and spherical aberration (SA) both increased after SMILE, and they had a similar significant negative correlation with A-EOZ. Moreover, there was a significant negative correlation between △-OZ and Km (X1), Q-value (X2), spherical equivalent (SE, X3), ablating depth (AD, X4) and △e (X6), and a significant positive correlation between △-OZ and △Q (X5). △H-OZ was expressed as Y1, △V-OZ as Y2, and △A-OZ as Y3. The multiple linear regression equations were as follows: Y1 = 3.683 - 0.065X1, Y2 = 1.549 - 0.469X2 - 0.059X3, Y3 = 4.015 - 0.07X1 - 0.03X3, Y1 = 1.337 - 0.005X4 + 0.413X5, Y2 = 1.265 + 0.469X5, and Y3 = 0.852 - 0.002X4 - 0.398X6. The correlation degree with △A-OZ was ranked as Km > △Q > Q-value > AD > e-value > △e > SE > △Km, as represented by the ridge regression analysis. The EOZ was irregularly reduced after SMILE, which should be taken into consideration in the design of POZ, especially for high myopia. Consideration of the refractive diopter and corneal topography is advised for the design of POZ, the latter of which has greater reference significance.


Assuntos
Cirurgia da Córnea a Laser , Aberrações de Frente de Onda da Córnea , Miopia , Humanos , Substância Própria/cirurgia , Acuidade Visual , Córnea/cirurgia , Refração Ocular , Topografia da Córnea , Miopia/cirurgia , Lasers de Excimer
2.
Eur J Ophthalmol ; 32(3): 1375-1385, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34821524

RESUMO

PURPOSE: To report two cases of polymicrobial keratitis following corneal collagen cross-linking for keratoconus and to review the literature. METHODS: Retrospective case note and literature review. RESULTS: The first case involved a 27-year-old male who presented with amebic corneal ulcers 3 days after the collagen cross-linking procedure. Some gram-negative (gram-ve) cocci were found upon staining, and cysts were observed by confocal microscopy at 7 days after surgery. Acanthamoeba infection mixed with gram-ve organisms was diagnosed. In the second case, a 14-year male developed Staphylococcus aureus corneal infection with anterior chamber empyema 3 days after the collagen cross-linking procedure for keratoconus. Occasional gram-positive (gram + ve) cocci and gram-ve bacilli were observed under a microscope. The mixed keratitis in the two patients resolved after systemic and topical antibiotic therapy, but the infection ultimately resulted in corneal scarring. Follow-up keratoplasty was needed to improve vision acuity in both patients. CONCLUSION: Although ultraviolet irradiation and the reactive oxygen released by riboflavin during collagen cross-linking have bactericidal effects, a lack of a corneal epithelial barrier, bandage contact lens usage, perioperative hygiene, and an abnormal immune state are risk factors for infectious keratitis after collagen cross-linking. Perioperative management of collagen cross-linking is important to prevent infection.


Assuntos
Ceratite , Ceratocone , Fotoquimioterapia , Infecções Estafilocócicas , Adulto , Antibacterianos/uso terapêutico , Colágeno/uso terapêutico , Substância Própria , Reagentes de Ligações Cruzadas/uso terapêutico , Humanos , Ceratite/diagnóstico , Ceratite/tratamento farmacológico , Ceratite/etiologia , Ceratocone/complicações , Ceratocone/tratamento farmacológico , Masculino , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Retrospectivos , Riboflavina/uso terapêutico , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/tratamento farmacológico , Raios Ultravioleta
3.
BMC Ophthalmol ; 21(1): 292, 2021 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-34340669

RESUMO

BACKGROUND: To compare the correction effect and optical quality after small-incision lenticule extraction (SMILE) and femtosecond laser assisted laser in situ keratomileusis (FS-LASIK) for high myopia. METHODS: 51 high myopia eyes after SMILE and 49 high myopia eyes after FS-LASIK were enrolled and divided into two groups retrospectively. The OQAS and iTrace analyzer were used for optical quality inspection. Between the two groups the spherical equivalent (SE), astigmatism, uncorrected distant visual acuity (UDVA), strehl ratio (SR), modulation transfer function cutoff frequency (MTF cutoff), objective scatter index (OSI) and wavefront aberrations were analyzed and compared before surgery and at 1, 6 and 12 months after surgery. RESULTS: After the operation: (1) SE and astigmatism declined and UDVA increased significantly in both groups, and UDVA was better after SMILE than FS-LASIK. (2) SR and MTF cutoff reduced and OSI increased significantly after SMILE and FS-LASIK. SR and MTF cutoff were significantly higher after SMILE than FS-LASIK. OSI was significantly lower after SMILE than FS-LASIK. (3) The total wavefront aberration, total low-order wavefront aberration, defocus and astigmatism aberration as well as trefoil aberration reduced significantly in both groups. The total high-order wavefront aberration increased significantly after FS-LASIK. The spherical and coma aberration increased significantly in both groups. The total high-order wavefront aberration and coma aberration at 1 month were higher after FS-LASIK than SMILE. CONCLUSION: The optical quality descended after SMILE and FS-LASIK. SMILE was superior to FS-LASIK at the correction effect and optical quality for high myopia. The combination of OQAS and iTrace analyzer is a valuable complementary measurement in evaluating the optical quality after the refractive surgery. TRIAL REGISTRATION: This is a retrospective study. This research was approved by the ethics committee of Xiangya Hospital and the IRB approval number is 201612074.


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Astigmatismo/cirurgia , Substância Própria , Humanos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Estudos Prospectivos , Estudos Retrospectivos
4.
J Ophthalmol ; 2021: 6667263, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34221494

RESUMO

PURPOSE: The purpose of this study is to test binocular visual function after femtosecond laser small incision lenticule extraction (SMILE) for high myopia. The traditional Titmus stereotest and dynamic stereotest based on the visual perception biological model were used for comparative analysis. METHODS: A total of 43 patients were enrolled in this prospective study. At Week 1, Month 1, and Month 3 after surgery, the Titmus stereotest and dynamic stereotest generated by MATLAB were conducted. Dynamic stereopsis consists of randomly flickering Gabor spots and is divided into two models of high energy and low energy according to flicker frequency. RESULTS: The preoperative manifest refraction spherical equivalent was -7.21 ± 0.70 D. The preoperative anisometropia was 0.52 ± 0.54D. The quartiles of static stereoacuity in preoperation and 3 follow-ups were as follows: 50.00 (25.00, 100.00) in preoperation, 63.00 (40.00, 63.00) at Week 1, 40.00 (32.00, 63.00) at Month 1, and 40.00 (25.00, 50.00) at Month 3. Static stereopsis improved at Month 1 and Month 3 compared with preoperation and Week 1 (P < 0.05). There were statistically significant differences in high energy dynamic stereopsis at Week 1 and Month 1 compared to preoperation (P < 0.05). In addition, significant differences in low energy dynamic stereopsis were detected between Month 1 and preoperation and also at Month 3 compared to Month 1 (P < 0.05). CONCLUSION: Most high myopia patients have a dynamic stereopsis deficiency before refractive correction. SMILE surgery can improve both static and dynamic stereopsis early in the postoperation period. However, in the long term, there is no significant difference or even a decrease in dynamic stereopsis.

5.
Exp Ther Med ; 22(1): 681, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33986846

RESUMO

The aim of the present study was to investigate the histological and morphological characteristics of corneal stromal lenticules extracted during femtosecond laser-assisted small incision lenticule extraction (SMILE) surgery by light and electron microscopy. A total of 20 human corneal stromal lenticules extracted during SMILE surgery were sent for microscopic examination immediately after surgery. Of these, six were observed under a light microscope and 14 were observed under an electron microscope. The smoothness of the front and rear surface of the lenticules observed under an electron microscope was rated on a scale of 0 to 4 according to unified evaluation criteria and the scores were statistically compared. Under the light microscope, the edge of the cross section of the corneal stromal lenticules was deeply stained and certain burrs and broken collagen fibers were observed. The swollen corneal stromal fibers were distributed irregularly, with a few bubbles of different sizes. Under the electron microscope, the surface of the lenticules ablated using a femtosecond laser was not perfectly smooth and the front surface was smoother than the rear surface. The side edge of the lenticules ablated using a femtosecond laser was not as regular as the edge cut using microscissors. Necrosis and dissolution of collagen fibers were observed near the surface of the lenticules. In conclusion, the surface quality of corneal stromal lenticules ablated using a femtosecond laser was not optimal when observed under a microscope. Increased attention should be paid to the histology and morphology of the corneal surface following laser ablation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA