Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
BMC Cardiovasc Disord ; 24(1): 149, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38475690

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is a prevalent disease that triggers systemic pathological changes including cardiac, respiratory, hepatic and digestive, hematopoietic, renal and skin issues. The burden of extra-cardiac manifestations has not been well described in TR patients and the clinical impact is unknown. METHODS: Patients with severe or more-than-severe TR during hospitalization, who did not have any previous cardiac procedures, hemodynamically significant congenital heart disease or concomitant severe aortic or mitral valve disease, were retrospectively analyzed. Pre-specified criteria and diagnosis of baseline characteristics were used to evaluate the presence of extra-cardiac manifestations secondary to TR after excluding comorbidities that may also lead to corresponding abnormalities. Extra-cardiac involvements encompass respiratory, hepatic and, digestive, renal, hematopoietic and dermatic system. Staging criteria are defined as no extra-cardiac system involvement in Stage 1, one in Stage 2, at least two extra-cardiac involvements in Stage 3 and any end-stage organ failure in Stage 4. A telephone follow-up was conducted to record the composite endpoint namely all-cause death or cardiac rehospitalization after the index hospitalization. RESULTS: A total of 258 patients were identified with a median age of 73 (interquartile range [IQR]: 62-83) years and 52.3% were female. Severe TR and more-than-severe TR patients accounted for 92.6% and 7.4% of the cohort. There were 20.5%, 27.5%, 37.6% and 14.3% of patients from Stage 1 to 4 respectively. The follow-up time was at a median of 251 (IQR: 183-324) days. TR Patients in Stage 3&4 were at an increased risk with borderline statistical significance to experience the composite endpoint compared to patients in Stage 1&2 (odds ratio [OR] 1.9, 95% confidence interval [CI] 1.0 to 3.7, P = 0.049). CONCLUSIONS: Approximately half of patients with at least severe TR presented with two or more extra-cardiac systemic manifestations, which may incur a 1.9-fold higher risk of all-cause death or cardiac rehospitalization than TR patients with one or less extra-cardiac involvement.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Insuficiência da Valva Tricúspide/etiologia , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Medição de Risco , Hemodinâmica
2.
Catheter Cardiovasc Interv ; 95 Suppl 1: 616-623, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31943783

RESUMO

OBJECTIVES: We evaluated the safety and usefulness of preparatory anatomical reshaping with a geometric hourglass-shaped balloon to optimize transcatheter aortic valve replacement (TAVR) outcomes in bicuspid aortic valve (BAV) stenosis. BACKGROUND: TAVR has been increasingly performed for BAV stenosis; however, technical challenges remain. Procedural results are suboptimal given unfavorable valvular anatomies. METHODS: Eligible patients with BAV stenosis were enrolled to undergo aortic valve predilatation with the hourglass-shaped TAV8 balloon before TAVR using the self-expandable Venus A-Valve. Procedural details and outcomes were compared to a sequential group of patients with BAV who underwent TAVR with the same device following preparatory dilatation using a cylindrical balloon. RESULTS: A total of 22 patients were enrolled in the TAV8 group and 53 were included in the control group. Valve downsizing was less common in the TAV8 group (36.4 vs. 67.9%; p = .012). Stable valve release and optimal implant depth were consistently achieved in the TAV8 group with no requirement for a second valve (0 vs. 17.0%; p = .039) and with higher device success rates (100.0 vs 77.4%; p = .014). Residual aortic regurgitation graded as ≥mild was less common in the TAV8 group (13.6 vs 45.3%; p = .009). Mortality was similar (0 vs. 3.8%; p = 1); no major/disabling stroke or conversion to open-heart surgery was seen in either group within 30 days. CONCLUSIONS: Compared with standard cylindrical balloon valvuloplasty, preparatory reshaping with the hourglass-shaped balloon before self-expandable TAVR in BAV was associated with significantly better procedural results and may encourage more promising outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/instrumentação , Doença da Válvula Aórtica Bicúspide/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Feminino , Humanos , Masculino , Projetos Piloto , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
4.
Am J Cardiol ; 117(10): 1629-1635, 2016 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-27026641

RESUMO

Evidence regarding the safety and feasibility of transcatheter aortic valve implantation without balloon predilation (BP) is scarce. A literature search of PubMed, EMBASE, CENTRAL, and major conference proceedings was performed from January 2002 to July 2015. There were 18 studies incorporating 2,443 patients included in the present study. No differences were observed in the baseline characteristics between patients without BP (no-BP) and with BP. Compared with BP, no-BP had a shorter procedure time (no-BP vs BP, 124.2 vs 138.8 minutes, p = 0.008), used less-contrast medium (no-BP vs BP, 126.3 vs 156.3 ml, p = 0.0005) and had a higher success rate (odds ratio [OR] 2.24, 95% CI 1.40 to -3.58). In addition, no-BP was associated with lower incidences of permanent pacemaker implantation (OR 0.45, 95% CI 0.3 to 0.67), grade 2 or greater paravalvular leakage (OR 0.55, 95% CI 0.37 to 0.83), and stroke (OR 0.57, 95% CI 0.32 to 1.0). Furthermore, no-BP was associated with a 0.6-fold decreased risk for 30-day all-cause mortality (OR 0.60, 95% CI 0.39 to 0.92). However, the difference in the risk for permanent pacemaker implantation, grade 2, or higher aortic regurgitation, stroke was noted to be significant only in the subgroup of the CoreValve-dominating studies. In conclusion, no-BP before transcatheter aortic valve implantation was not only safe and feasible but was also associated with fewer complications and short-term mortality in selected patients especially using self-expandable valve.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Valvuloplastia com Balão , Humanos , Desenho de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA