Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
BMC Surg ; 23(1): 336, 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37940918

RESUMO

BACKGROUND: With the development of minimally invasive technology, the trauma caused by surgery get smaller, At the same time, the specimen extraction surgery through the natural orifice is more favored by experts domestically and abroad, robotic surgery has further promoted the development of specimen extraction surgery through the natural orifice. The aim of current study is to compare the short-term outcomes of robotic-assisted natural orifice specimen extraction (NOSES ) and transabdominal specimen extraction(TRSE ) in median rectal cancer surgery. METHODS: From January 2020 to January 2023, 87 patients who underwent the NOSES or TRSE at the First Affiliated Hospital of Nanchang University were included in the study, 4 patients were excluded due to liver metastasis. Of these, 50 patients were in the TRSE and 33 patients in the NOSES. Short-term efficacy was compared in the two groups. RESULTS: The NOSES group had less operation time (P < 0.001), faster recovery of gastrointestinal function (P < 0.001), shorter abdominal incisions (P < 0.001), lower pain scores(P < 0.001). lower Inflammatory indicators of the white blood cell count and C-reactive protein content at 1, 3, and 5 days after surgery (P < 0.001, P = 0.037). There were 9 complications in the NOSES group and 11 complications in the TRSE group(P = 0.583). However, there were no wound complications in the NOSES group. The number of postoperative hospital stays seems to be same in the two groups. And there was no significant difference in postoperative anus function (P = 0.591). CONCLUSIONS: This study shows that NOSES and TRSE can achieve similar radical treatment effects, NOSES is a feasible and safe way to take specimens for rectal cancer surgery in accordance with the indication for NOSES.


Assuntos
Laparoscopia , Neoplasias Retais , Procedimentos Cirúrgicos Robóticos , Humanos , Estudos Retrospectivos , Neoplasias Retais/cirurgia , Reto , Resultado do Tratamento
2.
World J Surg Oncol ; 21(1): 196, 2023 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-37403084

RESUMO

BACKGROUND: Surgery is becoming less invasive as technology advances. Natural orifice specimen extraction surgery (NOSES) ushered in a new era of minimally invasive techniques. At the same time, NOSES is gaining popularity in the world. With their distinct advantages, surgical robots have advanced the development of NOSES. The aim of current study was to compare the short-term outcomes between robotic-assisted NOSES and laparoscopic-assisted NOSES for the treatment of middle rectal cancer. METHODS: Patients with middle rectal cancer who underwent robotic-assisted or laparoscopic-assisted NOSES at the First Affiliated Hospital of Nanchang University between January 2020 and June 2022 had their clinicopathological data collected retrospectively. 46 patients were enrolled in the study: 23 in the robotic group and 23 in the laparoscopic group. Short-term outcomes and postoperative anal function in the two groups were compared. RESULTS: There was no significant difference in the clinicopathological data between the two groups. The robotic group had less intraoperative blood loss (p = 0.04), less postoperative abdominal drainage (p = 0.02), lower postoperative white blood cell counts (p = 0.024) and C-reactive protein levels (p = 0.017), and shorter catheter removal time when compared to the laparoscopic group (p = 0.003). Furthermore, there were no significant difference in mean operative time (159 ± 31 min vs 172 ± 41 min) between the robotic and laparoscopic groups (p = 0.235), but time to naked the rectum (86.4 ± 20.9 min vs. 103.8 ± 31.5 min p = 0.033) and time of digestive tract reconstruction (15.6 ± 3.88 min vs. 22.1 ± 2.81 min p < 0.01) in the robotic group were significantly shorter than laparoscopic group. The robotic group had lower postoperative Wexner scores than the laparoscopic group. CONCLUSIONS: This research reveals that combining a robotic surgical system and NOSES results in superior outcomes, with short-term outcomes preferable to laparoscopic-assisted NOSES.


Assuntos
Laparoscopia , Neoplasias Retais , Procedimentos Cirúrgicos Robóticos , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Laparoscopia/métodos , Neoplasias Retais/cirurgia
3.
Curr Med Res Opin ; 33(5): 803-811, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28097889

RESUMO

OBJECTIVE: A systematic review and partial meta-analysis is conducted to compare the efficacy and safety of anterior cervical decompression and fusion procedures employing either rectangular titanium cages or iliac crest autografts in patients suffering from cervical degenerative disc diseases. METHODS: Medline, PubMed, CENTRAL, and Google Scholar databases were searched up to June 2015, using the key words cervical discectomy; bone transplantation; titanium cages; and iliac crest autografts. Outcomes of interbody fusion rates were compared using odds ratios (ORs) with 95% confidence intervals (CIs). Values of the Japanese Orthopaedic Association score, and visual analog scale before and after operation were also compared. RESULTS: The rate of interbody fusion was similar between patients in the iliac crest autograft and titanium cage groups (pooled OR = 0.33, 95% CI = 0.07 to 1.66, P = .178). The overall analysis showed that patients in the two groups did not have significantly different post-surgery Japanese Orthopaedic Association score (pooled difference in means = -0.05, 95% CI = 0.73 to 0.63, P = .876). Improvement in arm and neck pain scores were assessed with a visual analog scale and differed significantly between patients in the iliac crest autograft and titanium cage groups (pooled difference in means = 0.16, 95% CI = -0.44 to 0.76, P = .610; and pooled difference in means = -0.44, 95% CI = -2.23 to 1.36, P = .634, respectively). CONCLUSIONS: Our results suggest that the use of titanium cages constitutes a safe and efficient alternative to iliac crest bone autografts for anterior cervical discectomy with fusion.


Assuntos
Transplante Ósseo , Vértebras Cervicais , Discotomia , Ílio/transplante , Degeneração do Disco Intervertebral , Fusão Vertebral , Titânio/uso terapêutico , Transplante Ósseo/efeitos adversos , Transplante Ósseo/métodos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Pesquisa Comparativa da Efetividade , Discotomia/efeitos adversos , Discotomia/instrumentação , Discotomia/métodos , Humanos , Degeneração do Disco Intervertebral/diagnóstico , Degeneração do Disco Intervertebral/cirurgia , Avaliação de Processos e Resultados em Cuidados de Saúde , Radiografia/métodos , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Transplante Autólogo
4.
Orthop Surg ; 8(3): 367-76, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27627721

RESUMO

OBJECTIVES: To evaluate the biomechanical characteristics of endplate-conformed cervical cages by finite element method (FEM) analysis and cadaver study. METHODS: Twelve specimens (C2 -C7 ) and a finite element model (C3 -C7 ) were subjected to biomechanical evaluations. In the cadaver study, specimens were randomly assigned to intact (I), endplate-conformed (C) and non-conformed (N) groups with C4-5 discs as the treated segments. The morphologies of the endplate-conformed cages were individualized according to CT images of group C and the cages fabricated with a 3-D printer. The non-conformed cages were wedge-shaped and similar to commercially available grafts. Axial pre-compression loads of 73.6 N and moment of 1.8 Nm were used to simulate flexion (FLE), extension (EXT), lateral bending (LB) and axial rotation (AR). Range of motion (ROM) at C4-5 of each specimen was recorded and film sensors fixed between the cages and C5 superior endplates were used to detect interface stress. A finite element model was built based on the CT data of a healthy male volunteer. The morphologies of the endplate-conformed and wedge-shaped, non-conformed cervical cages were both simulated by a reverse engineering technique and implanted at the segment of C4-5 in the finite element model for biomechanical evaluation. Force loading and grouping were similar to those applied in the cadaver study. ROM of C4-5 in group I were recorded to validate the finite element model. Additionally, maximum cage-endplate interface stresses, stress distribution contours on adjoining endplates, intra-disc stresses and facet loadings at adjacent segments were measured and compared between groups. RESULTS: In the cadaver study, Group C showed a much lower interface stress in all directions of motion (all P < 0.05) and the ROM of C4-5 was smaller in FLE-EXT (P = 0.001) but larger in AR (P = 0.017). FEM analysis produced similar results: the model implanted with an endplate-conformed cage presented a lower interface stress with a more uniform stress distribution than that implanted with a non-conformed cage. Additionally, intra-disc stress and facet loading at the adjacent segments were obviously increased in both groups C and N, especially those at the supra-jacent segments. However, stress increase was milder in group C than in group N for all directions of motion. CONCLUSIONS: Endplate-conformed cages can decrease cage-endplate interface stress in all directions of motion and increase cervical stability in FLE-EXT. Additionally, adjacent segments are possibly protected because intra-disc stress and facet loading are smaller after endplate-conformed cage implantation. However, axial stability was reduced in group C, indicating that endplate-conformed cage should not be used alone and an anterior plate system is still important in anterior cervical discectomy and fusion.


Assuntos
Vértebras Cervicais/cirurgia , Fixadores Internos , Fusão Vertebral/instrumentação , Adulto , Fenômenos Biomecânicos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/fisiologia , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Pessoa de Meia-Idade , Distribuição Aleatória , Amplitude de Movimento Articular , Estresse Mecânico , Tomografia Computadorizada por Raios X , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA