RESUMO
PURPOSE: Modified reduced FOV diffusion-weighted imaging (DWI) using spatially-tailored 2D RF pulses with tilted excitation plane (tilted r-DWI) has been developed. The purpose of this study was to evaluate the impact on image quality and quantitative apparent diffusion coefficient (ADC) values of tilted r-DWI for pancreatic ductal adenocarcinomas (PDAC) in comparison to conventional full-FOV DWI (f-DWI). METHODS: This retrospective study included 21 patients (mean 70.7, range 50-85 years old) with pathologically confirmed PDAC. All MR images were obtained using 3 T systems. Two radiologists evaluated presence of blurring or ghost artifacts, susceptibility artifacts, and aliasing artifacts; anatomic visualization of the pancreas; interslice signal homogeneity; overall image quality; and conspicuity of the PDAC. For quantitative analysis, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), signal-intensity ratio (SIR) and ADC values were measured using regions of interest. RESULTS: All image quality scores except aliasing artifacts in tilted r-DWI were significantly higher than those in f-DWI (p < 0.01). The CNR and SIR of PDAC were significantly higher in tilted r-DWI than in f-DWI (6.7 ± 4.4 vs. 4.7 ± 3.9, 2.02 ± 0.72 vs. 1.72 ± 0.60, p < 0.01). Conversely, the SNR of PDAC in tilted r-DWI was significantly lower than that in f-DWI (56.0 ± 33.1 vs. 113.6 ± 67.3, p < 0.01). No significant difference was observed between mean ADC values of the PDAC calculated from tilted r-DWI (tilted r-ADC) and those from f-DWI (f-ADC) (1225 ± 250 vs. 1294 ± 302, p = 0.11). CONCLUSION: The r-DWI using 2D RF techniques with a tilted excitation plane was shown to significantly improve the image quality and CNR and reduce image artifacts compared to f-DWI techniques in MRI evaluations of PDAC without significantly affecting ADC values.
Assuntos
Adenocarcinoma , Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Neoplasias Pancreáticas/diagnóstico por imagem , Adenocarcinoma/diagnóstico por imagem , Estudos Retrospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Carcinoma Ductal Pancreático/diagnóstico por imagem , Reprodutibilidade dos Testes , Imagem Ecoplanar/métodos , Neoplasias PancreáticasRESUMO
PURPOSE: To evaluate the image quality qualitatively and quantitatively, as well as apparent diffusion coefficient (ADC) values of modified reduced field-of-view diffusion-weighted magnetic resonance imaging (MRI) using spatially tailored two-dimensional radiofrequency pulses with tilted excitation plane (tilted r-DWI) based on single-shot echo planar imaging (SS-EPI) compared with full-size field-of-view DWI (f-DWI) using readout segmented (RS)-EPI in patients with rectal cancer. MATERIALS AND METHODS: Twenty-two patients who underwent an MRI for further evaluation of rectal cancer were included in this retrospective study. All MR images were analyzed to compare image quality, lesion conspicuity, and artifacts between f-DWI with RS-EPI and tilted r-DWI with SS-EPI. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and ADC values were also compared. The Wilcoxon signed-rank test or paired t test was performed to compare the qualitative and quantitative assessments. RESULTS: All image quality scores, except aliasing artifacts, were significantly higher (p < 0.01 for all) in tilted r-DWI than f-DWI with RS-EPI. CNR in tilted r-DWI was significantly higher than in f-DWI with RS-EPI (p < 0.01), while SNR was not significantly different. Regarding the ADC values, no significant difference was observed between tilted r-DWI and f-DWI with RS-EPI (p = 0.27). CONCLUSION: Tilted r-DWI provides a better image quality with fewer artifacts and higher rectal lesion conspicuity than f-DWI with RS-EPI, indicating the feasibility of this MR sequence in evaluating rectal cancer in clinical practice.
Assuntos
Imagem Ecoplanar , Neoplasias Retais , Humanos , Imagem Ecoplanar/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Neoplasias Retais/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Reprodutibilidade dos TestesRESUMO
Objective. This study aimed to produce a three-dimensional liver elasticity map using the finite element method (FEM) and respiration-induced motion captured by T1-weighted magnetic resonance images (FEM-E-map) and to evaluate whether FEM-E-maps can be an imaging biomarker comparable to magnetic resonance elastography (MRE) for assessing the distribution and severity of liver fibrosis.Approach. We enrolled 14 patients who underwent MRI and MRE. T1-weighted MR images were acquired during shallow inspiration and expiration breath-holding, and the displacement vector field (DVF) between two images was calculated using deformable image registration. FEM-E-maps were constructed using FEM and DVF. First, three Poisson's ratio settings (0.45, 0.49, and 0.499995) were validated and optimized to minimize the difference in liver elasticity between the FEM-E-map and MRE. Then, the whole and regional liver elasticity values estimated using FEM-E-maps were compared with those obtained from MRE using Pearson's correlation coefficients. Spearman rank correlations and chi-square histograms were used to compare the voxel-level elasticity distribution.Main results. The optimal Poisson's ratio was 0.49. Whole liver elasticity estimated using FEM-E-maps was strongly correlated with that measured using MRE (r = 0.96). For regional liver elasticity, the correlation was 0.84 for the right lobe and 0.82 for the left lobe. Spearman analysis revealed a moderate correlation for the voxel-level elasticity distribution between FEM-E-maps and MRE (0.61 ± 0.10). The small chi-square distances between the two histograms (0.11 ± 0.07) indicated good agreement.Significance. FEM-E-maps represent a potential imaging biomarker for visualizing the distribution of liver fibrosis using only T1-weighted images obtained with a common MR scanner, without any additional examination or special elastography equipment. However, additional studies including comparisons with biopsy findings are required to verify the reliability of this method for clinical application.
Assuntos
Técnicas de Imagem por Elasticidade , Biomarcadores , Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos TestesRESUMO
PURPOSE: This study aimed to quantify the respiration-induced motion in each pancreatic region during motion mitigation strategies and to characterize the correlations between this motion and that of the surrogate signals in cine-magnetic resonance imaging (MRI). We also aimed to evaluate the effects of these motion mitigation strategies in each pancreatic region. METHODS: Sagittal and coronal two-dimensional cine-MR images were obtained in 11 healthy volunteers, eight of whom also underwent imaging with abdominal compression (AC). For each pancreatic region, the magnitude of pancreatic motion with and without motion mitigation and the positional error between the actual and predicted pancreas motion based on surrogate signals were evaluated. RESULTS: The magnitude of pancreatic motion with and without AC in the left-right (LR) and superior-inferior (SI) directions varied depending on the pancreatic region. In respiratory gating (RG) assessments based on a surrogate signal, although the correlation was reasonable, the positional error was large in the pancreatic tail region. Furthermore, motion mitigation in the anterior-posterior and SI directions with RG was more effective than was that with AC in the head region. CONCLUSIONS: This study revealed pancreatic region-dependent variations in respiration-induced motion and their effects on motion mitigation outcomes during AC or RG. The magnitude of pancreatic motion with or without AC and the magnitude of the positional error with RG varied depending on the pancreatic region. Therefore, during radiation therapy for pancreatic cancer, it is important to consider that the effects of motion mitigation during AC or RG may differ depending on the pancreatic region.