Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cochrane Database Syst Rev ; 3: CD010890, 2022 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-35320584

RESUMO

BACKGROUND: Systematic screening in high-burden settings is recommended as a strategy for early detection of pulmonary tuberculosis disease, reducing mortality, morbidity and transmission, and improving equity in access to care. Questioning for symptoms and chest radiography (CXR) have historically been the most widely available tools to screen for tuberculosis disease. Their accuracy is important for the design of tuberculosis screening programmes and determines, in combination with the accuracy of confirmatory diagnostic tests, the yield of a screening programme and the burden on individuals and the health service. OBJECTIVES: To assess the sensitivity and specificity of questioning for the presence of one or more tuberculosis symptoms or symptom combinations, CXR, and combinations of these as screening tools for detecting bacteriologically confirmed pulmonary tuberculosis disease in HIV-negative adults and adults with unknown HIV status who are considered eligible for systematic screening for tuberculosis disease. Second, to investigate sources of heterogeneity, especially in relation to regional, epidemiological, and demographic characteristics of the study populations. SEARCH METHODS: We searched the MEDLINE, Embase, LILACS, and HTA (Health Technology Assessment) databases using pre-specified search terms and consulted experts for unpublished reports, for the period 1992 to 2018. The search date was 10 December 2018. This search was repeated on 2 July 2021. SELECTION CRITERIA: Studies were eligible if participants were screened for tuberculosis disease using symptom questions, or abnormalities on CXR, or both, and were offered confirmatory testing with a reference standard. We included studies if diagnostic two-by-two tables could be generated for one or more index tests, even if not all participants were subjected to a microbacteriological reference standard. We excluded studies evaluating self-reporting of symptoms. DATA COLLECTION AND ANALYSIS: We categorized symptom and CXR index tests according to commonly used definitions. We assessed the methodological quality of included studies using the QUADAS-2 instrument. We examined the forest plots and receiver operating characteristic plots visually for heterogeneity. We estimated summary sensitivities and specificities (and 95% confidence intervals (CI)) for each index test using bivariate random-effects methods. We analyzed potential sources of heterogeneity in a hierarchical mixed-model. MAIN RESULTS: The electronic database search identified 9473 titles and abstracts. Through expert consultation, we identified 31 reports on national tuberculosis prevalence surveys as eligible (of which eight were already captured in the search of the electronic databases), and we identified 957 potentially relevant articles through reference checking. After removal of duplicates, we assessed 10,415 titles and abstracts, of which we identified 430 (4%) for full text review, whereafter we excluded 364 articles. In total, 66 articles provided data on 59 studies. We assessed the 2 July 2021 search results; seven studies were potentially eligible but would make no material difference to the review findings or grading of the evidence, and were not added in this edition of the review. We judged most studies at high risk of bias in one or more domains, most commonly because of incorporation bias and verification bias. We judged applicability concerns low in more than 80% of studies in all three domains. The three most common symptom index tests, cough for two or more weeks (41 studies), any cough (21 studies), and any tuberculosis symptom (29 studies), showed a summary sensitivity of 42.1% (95% CI 36.6% to 47.7%), 51.3% (95% CI 42.8% to 59.7%), and 70.6% (95% CI 61.7% to 78.2%, all very low-certainty evidence), and a specificity of 94.4% (95% CI 92.6% to 95.8%, high-certainty evidence), 87.6% (95% CI 81.6% to 91.8%, low-certainty evidence), and 65.1% (95% CI 53.3% to 75.4%, low-certainty evidence), respectively. The data on symptom index tests were more heterogenous than those for CXR. The studies on any tuberculosis symptom were the most heterogeneous, but had the lowest number of variables explaining this variation. Symptom index tests also showed regional variation. The summary sensitivity of any CXR abnormality (23 studies) was 94.7% (95% CI 92.2% to 96.4%, very low-certainty evidence) and 84.8% (95% CI 76.7% to 90.4%, low-certainty evidence) for CXR abnormalities suggestive of tuberculosis (19 studies), and specificity was 89.1% (95% CI 85.6% to 91.8%, low-certainty evidence) and 95.6% (95% CI 92.6% to 97.4%, high-certainty evidence), respectively. Sensitivity was more heterogenous than specificity, and could be explained by regional variation. The addition of cough for two or more weeks, whether to any (pulmonary) CXR abnormality or to CXR abnormalities suggestive of tuberculosis, resulted in a summary sensitivity and specificity of 99.2% (95% CI 96.8% to 99.8%) and 84.9% (95% CI 81.2% to 88.1%) (15 studies; certainty of evidence not assessed). AUTHORS' CONCLUSIONS: The summary estimates of the symptom and CXR index tests may inform the choice of screening and diagnostic algorithms in any given setting or country where screening for tuberculosis is being implemented. The high sensitivity of CXR index tests, with or without symptom questions in parallel, suggests a high yield of persons with tuberculosis disease. However, additional considerations will determine the design of screening and diagnostic algorithms, such as the availability and accessibility of CXR facilities or the resources to fund them, and the need for more or fewer diagnostic tests to confirm the diagnosis (depending on screening test specificity), which also has resource implications. These review findings should be interpreted with caution due to methodological limitations in the included studies and regional variation in sensitivity and specificity. The sensitivity and specificity of an index test in a specific setting cannot be predicted with great precision due to heterogeneity. This should be borne in mind when planning for and implementing tuberculosis screening programmes.


Assuntos
Infecções por HIV , Tuberculose Pulmonar , Adulto , Tosse , Infecções por HIV/complicações , Humanos , Programas de Rastreamento , Radiografia , Sensibilidade e Especificidade , Tuberculose Pulmonar/diagnóstico por imagem , Tuberculose Pulmonar/epidemiologia
2.
Cochrane Database Syst Rev ; 11: CD013787, 2020 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-33211319

RESUMO

BACKGROUND: Specific diagnostic tests to detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and resulting COVID-19 disease are not always available and take time to obtain results. Routine laboratory markers such as white blood cell count, measures of anticoagulation, C-reactive protein (CRP) and procalcitonin, are used to assess the clinical status of a patient. These laboratory tests may be useful for the triage of people with potential COVID-19 to prioritize them for different levels of treatment, especially in situations where time and resources are limited. OBJECTIVES: To assess the diagnostic accuracy of routine laboratory testing as a triage test to determine if a person has COVID-19. SEARCH METHODS: On 4 May 2020 we undertook electronic searches in the Cochrane COVID-19 Study Register and the COVID-19 Living Evidence Database from the University of Bern, which is updated daily with published articles from PubMed and Embase and with preprints from medRxiv and bioRxiv. In addition, we checked repositories of COVID-19 publications. We did not apply any language restrictions. SELECTION CRITERIA: We included both case-control designs and consecutive series of patients that assessed the diagnostic accuracy of routine laboratory testing as a triage test to determine if a person has COVID-19. The reference standard could be reverse transcriptase polymerase chain reaction (RT-PCR) alone; RT-PCR plus clinical expertise or and imaging; repeated RT-PCR several days apart or from different samples; WHO and other case definitions; and any other reference standard used by the study authors. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data from each included study. They also assessed the methodological quality of the studies, using QUADAS-2. We used the 'NLMIXED' procedure in SAS 9.4 for the hierarchical summary receiver operating characteristic (HSROC) meta-analyses of tests for which we included four or more studies. To facilitate interpretation of results, for each meta-analysis we estimated summary sensitivity at the points on the SROC curve that corresponded to the median and interquartile range boundaries of specificities in the included studies. MAIN RESULTS: We included 21 studies in this review, including 14,126 COVID-19 patients and 56,585 non-COVID-19 patients in total. Studies evaluated a total of 67 different laboratory tests. Although we were interested in the diagnotic accuracy of routine tests for COVID-19, the included studies used detection of SARS-CoV-2 infection through RT-PCR as reference standard. There was considerable heterogeneity between tests, threshold values and the settings in which they were applied. For some tests a positive result was defined as a decrease compared to normal vaues, for other tests a positive result was defined as an increase, and for some tests both increase and decrease may have indicated test positivity. None of the studies had either low risk of bias on all domains or low concerns for applicability for all domains. Only three of the tests evaluated had a summary sensitivity and specificity over 50%. These were: increase in interleukin-6, increase in C-reactive protein and lymphocyte count decrease. Blood count Eleven studies evaluated a decrease in white blood cell count, with a median specificity of 93% and a summary sensitivity of 25% (95% CI 8.0% to 27%; very low-certainty evidence). The 15 studies that evaluated an increase in white blood cell count had a lower median specificity and a lower corresponding sensitivity. Four studies evaluated a decrease in neutrophil count. Their median specificity was 93%, corresponding to a summary sensitivity of 10% (95% CI 1.0% to 56%; low-certainty evidence). The 11 studies that evaluated an increase in neutrophil count had a lower median specificity and a lower corresponding sensitivity. The summary sensitivity of an increase in neutrophil percentage (4 studies) was 59% (95% CI 1.0% to 100%) at median specificity (38%; very low-certainty evidence). The summary sensitivity of an increase in monocyte count (4 studies) was 13% (95% CI 6.0% to 26%) at median specificity (73%; very low-certainty evidence). The summary sensitivity of a decrease in lymphocyte count (13 studies) was 64% (95% CI 28% to 89%) at median specificity (53%; low-certainty evidence). Four studies that evaluated a decrease in lymphocyte percentage showed a lower median specificity and lower corresponding sensitivity. The summary sensitivity of a decrease in platelets (4 studies) was 19% (95% CI 10% to 32%) at median specificity (88%; low-certainty evidence). Liver function tests The summary sensitivity of an increase in alanine aminotransferase (9 studies) was 12% (95% CI 3% to 34%) at median specificity (92%; low-certainty evidence). The summary sensitivity of an increase in aspartate aminotransferase (7 studies) was 29% (95% CI 17% to 45%) at median specificity (81%) (low-certainty evidence). The summary sensitivity of a decrease in albumin (4 studies) was 21% (95% CI 3% to 67%) at median specificity (66%; low-certainty evidence). The summary sensitivity of an increase in total bilirubin (4 studies) was 12% (95% CI 3.0% to 34%) at median specificity (92%; very low-certainty evidence). Markers of inflammation The summary sensitivity of an increase in CRP (14 studies) was 66% (95% CI 55% to 75%) at median specificity (44%; very low-certainty evidence). The summary sensitivity of an increase in procalcitonin (6 studies) was 3% (95% CI 1% to 19%) at median specificity (86%; very low-certainty evidence). The summary sensitivity of an increase in IL-6 (four studies) was 73% (95% CI 36% to 93%) at median specificity (58%) (very low-certainty evidence). Other biomarkers The summary sensitivity of an increase in creatine kinase (5 studies) was 11% (95% CI 6% to 19%) at median specificity (94%) (low-certainty evidence). The summary sensitivity of an increase in serum creatinine (four studies) was 7% (95% CI 1% to 37%) at median specificity (91%; low-certainty evidence). The summary sensitivity of an increase in lactate dehydrogenase (4 studies) was 25% (95% CI 15% to 38%) at median specificity (72%; very low-certainty evidence). AUTHORS' CONCLUSIONS: Although these tests give an indication about the general health status of patients and some tests may be specific indicators for inflammatory processes, none of the tests we investigated are useful for accurately ruling in or ruling out COVID-19 on their own. Studies were done in specific hospitalized populations, and future studies should consider non-hospital settings to evaluate how these tests would perform in people with milder symptoms.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Testes Diagnósticos de Rotina/métodos , SARS-CoV-2/isolamento & purificação , Viés , Biomarcadores/sangue , Proteína C-Reativa/análise , COVID-19/sangue , COVID-19/epidemiologia , Teste para COVID-19/normas , Creatina Quinase/sangue , Creatinina/sangue , Testes Diagnósticos de Rotina/normas , Humanos , Interleucina-6/sangue , L-Lactato Desidrogenase/sangue , Contagem de Leucócitos , Testes de Função Hepática , Contagem de Linfócitos , Pandemias , Contagem de Plaquetas , Curva ROC , Valores de Referência , Reação em Cadeia da Polimerase Via Transcriptase Reversa/normas , Sensibilidade e Especificidade , Triagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA