Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
Surgery ; 170(4): 1155-1159, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34090673

RESUMO

BACKGROUND: Although there are several publications on the new transoral robotic thyroidectomy technique, few have thoroughly reviewed its associated complications. This study analyzed the causes and prevention of transoral robotic thyroidectomy-specific complications and presented preventive measures. METHODS: The medical records of patients who underwent transoral robotic thyroidectomy performed by a single surgeon between March 1, 2009 and April 30, 2019 were retrospectively analyzed. Patient demographic, clinical, and operative data were analyzed using descriptive statistics. We describe the transoral robotic thyroidectomy-related complications experienced at our institution and how to overcome them. RESULTS: This study included a total of 423 patients who underwent transoral robotic thyroidectomy. The general surgical complications included immediate postoperative bleeding (2 cases) and delayed hematoma (3 cases). Chyle leakage and localized wound infection were found in 1 case each. Transient vocal cord palsy occurred in 4 cases, and 1 case developed transient hypoparathyroidism. The transoral robotic thyroidectomy-specific complications included zygoma bruise (2 cases), flap bruise (3 cases), chin flap perforation (2 cases), and oral commissure tearing (2 cases). The complications occurring when creating the flap included flap burns (4 cases), skin dimpling in the midline of the lower chin (2 cases), and hematomas in the intraoral trocar insertion sites (3 cases). CONCLUSION: Surgeons familiar with thyroid surgery and experienced in robotic surgery can perform transoral robotic thyroidectomy without causing more complications than those seen with traditional surgery.


Assuntos
Cirurgia Endoscópica por Orifício Natural/métodos , Complicações Pós-Operatórias/prevenção & controle , Câncer Papilífero da Tireoide/cirurgia , Neoplasias da Glândula Tireoide/cirurgia , Tireoidectomia/métodos , Adulto , Feminino , Seguimentos , Humanos , Masculino , Boca , Duração da Cirurgia , Complicações Pós-Operatórias/epidemiologia , República da Coreia/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento
3.
Surg Endosc ; 35(1): 124-129, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-31925503

RESUMO

BACKGROUND: Various approaches for thyroid surgery became possible with the use of robotic systems. Transoral robotic thyroidectomy (TORT) is one of the newest approaches and draws attention because of its cosmetic excellence. In this study, we compared the surgical outcomes of TORT and conventional open thyroidectomy (OT). METHODS: We retrospectively reviewed and compared the medical records of consecutive patients who underwent TORT or OT for thyroid carcinoma from March 2009 to January 2018. Propensity score matching using 10 clinico-pathologic factors was used to generate two matched cohorts, each composed of 186 patients. RESULTS: The study included 372 patients who underwent TORT (n = 186) or OT (n = 186). Mean age, tumor size, and gender were not different between both groups. The two groups showed similar surgical outcomes, except for a longer operative time for TORT. There was one patient with immediate postoperative bleeding in the TORT group. The patient underwent re-operation for hemostasis with endoscopic approach. In the OT group, one patient had wound seroma, which was treated by several rounds of needle aspiration without infection. Vocal cord palsy was present in one patient in the TORT group, which was recovered in 3 months. CONCLUSIONS: TORT could be performed safely and had comparable surgical outcomes with OT in the selected patients. TORT may be a suitable operative alternative for patients who do not want to leave scars on the neck.


Assuntos
Cirurgia Endoscópica por Orifício Natural/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Neoplasias da Glândula Tireoide/cirurgia , Tireoidectomia/métodos , Adulto , Cicatriz/etiologia , Cicatriz/prevenção & controle , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Duração da Cirurgia , Complicações Pós-Operatórias , Pontuação de Propensão , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Seroma/etiologia , Tireoidectomia/efeitos adversos , Resultado do Tratamento , Paralisia das Pregas Vocais/etiologia
4.
Gland Surg ; 9(5): 1363-1369, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33224811

RESUMO

BACKGROUND: Precise dissection with hemostasis while preserving important structures is critical in thyroid surgeries. In this study, we tested the safety of the Hemostatix Shaw scalpel (HSS) around the recurrent laryngeal nerve (RLN) in porcine models. METHODS: Four piglets were used to obtain continuous intraoperative neuromonitoring data. The HSS was applied at various distances from the RLN, with various temperature settings. Monopolar electrosurgical pencil and Harmonic scalpel were also tested for comparison. RESULTS: The use of HSS did not show adverse electromyographic (EMG) events when activated at 3- and 5-mm distances from the RLN. At a 1-mm distance, adverse event was observed at 300 °C after 2 seconds of activation. At 210 °C, adverse event was observed when the instrument was directly adjacent to the RLN. For comparison, an electrosurgical pencil, set at coagulation mode (25W), showed an irreversible adverse EMG event during 5 seconds of activation at 1-mm distance from the RLN. Harmonic ACE+, activation power at level 5, was also applied in one RLN and reversable adverse EMG event was observed at <0.1-mm (contact) distance after 3 seconds of activation. CONCLUSIONS: The safety distance of the HSS was 3 mm for the 300 °C setting and >1 mm for the 210 °C setting in the swine models in this study. Surgeons must understand the specific characteristics of various energy devices and apply them appropriately for safe operation.

5.
Breast Cancer Res Treat ; 172(2): 437-444, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30132220

RESUMO

PURPOSE: TP53 mutation is the most common mutation in breast cancer, and it is considered a target marker of triple-negative breast cancer (TNBC). We investigated whether expression of p53 detected by immunochemical staining predicts the chemotherapy response of TNBC. METHODS: A total of 11,393 TNBC patients who had between stage I and stage III enrolled in the Korean Breast Cancer Society Registry database from January 1, 2000 to December 31, 2015. There were 6,331 'p53-positive (+) TNBC' patients and 5062 'p53-negative (-) TNBC' patients. RESULTS: In univariate analysis, p53(+) TNBC had a worse prognosis than p53(-) TNBC in patients not receiving chemotherapy (P = 0.003). However, there was no difference in prognosis between p53(+) TNBC and p53(-) TNBC for patients receiving chemotherapy. In multivariate analysis adjusted for age and stage, the risk of p53(+) TNBC was 1.84 times higher than that of p53(-) TNBC in the non-chemotherapy group. However, there was no difference between p53(+) TNBC and p53(-) TNBC in patients receiving chemotherapy. In p53(+) TNBC, the risk was 0.6-fold lower when chemotherapy was administered than when chemotherapy was not administered. However, in p53(-) TNBC, there was no risk reduction effect by chemotherapy. CONCLUSION: The prognosis of p53(+) TNBC has worse than p53(-) TNBC, but the risk for survival was significantly reduced with chemotherapy. It suggests that p53(+) TNBC would be more sensitive to chemotherapy than p53(-) TNBC.


Assuntos
Biomarcadores Tumorais/genética , Quimioterapia Adjuvante/efeitos adversos , Neoplasias de Mama Triplo Negativas/tratamento farmacológico , Proteína Supressora de Tumor p53/genética , Adulto , Idoso , Intervalo Livre de Doença , Feminino , Humanos , Pessoa de Meia-Idade , Mutação , Prognóstico , Neoplasias de Mama Triplo Negativas/genética , Neoplasias de Mama Triplo Negativas/patologia
6.
Ann Surg Treat Res ; 93(6): 316-321, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29250511

RESUMO

PURPOSE: Partially absorbable mesh has been introduced and used for inguinal hernia repair for the purpose of minimizing pain and improving abdominal wall compliance. In this study, we evaluate the efficacy and safety of ProFlex mesh, a partially absorbed mesh with new structural architecture. METHODS: We retrospectively reviewed 64 cases of totally extraperitoneal herniorrhapy (TEP) from January 2013 to December 2014 for their clinical features, including operation time, pain, postoperative complications, and recurrence. RESULTS: There were no significant differences in operation time, hospital stay, postoperative pain, or complications between the 28 patients who received the ProFlex mesh and the 36 who received nonabsorbable lightweight mesh, although one patient who received the nonabsorbable had a recurrence during follow-up. There were differences in operation time, complications, and hospital stay according to the surgeon's previous operation volume. CONCLUSION: This study showed that there were significant differences in the fixation strength of different polypropylene meshes in combination with various fibrin glues. ProFlex, a partially absorbable mesh with new architecture, was feasible and safe in TEP.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA