Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Molecules ; 23(10)2018 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-30309038

RESUMO

A simple and sensitive cloud point extraction method for the preconcentration of ultra-trace amounts of nickel as a prior step to its determination by graphite furnace atomic absorption spectrometry was proposed. It is based on the reaction of nickel with 2-(5-bromo-2-pyridylazo)-5-dimethylaminoaniline (5-Br-PADMA) in HAc⁻NaAc buffer media and mixed micelle-mediated extraction of the complex using the anionic surfactant sodium dodecyl sulfate sodium (SDS) and non-ionic surfactant (1,1,3,3-Tetramethylbutyl)phenyl-polyethylene (Triton X-114). The optimal reaction and extraction conditions such as pH, concentration of 5-Br-PADMA, SDS and Triton X-114, equilibrium temperature, incubation, and centrifuge time were evaluated and optimized. Under the optimal conditions, the calibration graph was linear over the range 0.1⁻5.5 ng/mL of nickel with a correlation coefficient of 0.9942. The detection limit obtained was 0.031 ng/mL, and the relative standard deviation was 2.1% for nickel (c = 2 ng/mL, n = 6). The proposed method was successfully applied to the determination of nickel in water samples.


Assuntos
Grafite/química , Micelas , Níquel/análise , Espectrofotometria Atômica/métodos , Poluentes Químicos da Água/análise , Compostos de Anilina , Calibragem , Concentração de Íons de Hidrogênio , Íons , Limite de Detecção , Octoxinol , Polietilenoglicóis/química , Dodecilsulfato de Sódio/química , Temperatura , Fatores de Tempo
2.
Molecules ; 22(4)2017 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-28338642

RESUMO

A highly sensitive method based on cloud point extraction (CPE) separation/preconcentration and graphite furnace atomic absorption spectrometry (GFAAS) detection has been developed for the determination of ultra-trace amounts of rhodium in water samples. A new reagent, 2-(5-iodo-2-pyridylazo)-5-dimethylaminoaniline (5-I-PADMA), was used as the chelating agent and the nonionic surfactant TritonX-114 was chosen as extractant. In a HAc-NaAc buffer solution at pH 5.5, Rh(III) reacts with 5-I-PADMA to form a stable chelate by heating in a boiling water bath for 10 min. Subsequently, the chelate is extracted into the surfactant phase and separated from bulk water. The factors affecting CPE were investigated. Under the optimized conditions, the calibration graph was linear in the range of 0.1-6.0 ng/mL, the detection limit was 0.023 ng/mL for rhodium and relative standard deviation was 3.67% (c = 1.0 ng/mL, n = 11).The method has been applied to the determination of trace rhodium in water samples with satisfactory results.


Assuntos
Compostos de Anilina/química , Quelantes/química , Grafite/química , Ródio/análise , Espectrofotometria Atômica/métodos , Poluentes Químicos da Água/análise , Calibragem , Concentração de Íons de Hidrogênio , Limite de Detecção , Octoxinol , Polietilenoglicóis , Temperatura , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA