Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 148: 106197, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37875041

RESUMO

Mandibular reconstruction with free fibular flaps is frequently used to restore segmental defects. The osteosythesis, including locking and non-locking plate/screw systems, is essential to the mandibular reconstruction. Compared with the non-locking system that requires good adaption between plate and bone, the locking system appears to present a better performance by locking the plate to fixation screws. However, it also brings about limitations on screw options, a higher risk of screw failure, and difficulties in screw placement. Furthermore, its superiority is undermined by the advancing of patient-specific implant design and additive manufacturing. A customized plate can be designed and fabricated to accurately match the mandibular contour for patient-specific mandibular reconstruction. Consequently, the non-locking system seems more practicable with such personalized plates, and its biomechanical feasibility ought to be estimated. Finite element analyses of mandibular reconstruction assemblies were conducted for four most common segmental mandibular reconstructions regarding locking and non-locking systems under incisal biting and right molars clenching, during which the influencing factor of muscles' capacity was introduced to simulate the practical loadings after mandibular resection and reconstruction surgeries. Much higher, somewhat lower, and similar maximum von Mises stresses are separately manifested by the patient-specific mandibular reconstruction plate (PSMRP), fixation screws, and reconstructed mandible with the non-locking system than those with the locking system. Equivalent maximum displacements are identified between PSMRPs, fixation screws, and reconstructed mandibles with the non-locking and locking system in all four reconstruction types during two masticatory tasks. Parallel maximum and minimum principal strain distributions are shared by the reconstructed mandibles with the non-locking and locking system in four mandibular reconstructions during both occlusions. Conclusively, it is feasible to use the non-locking system in case of patient-specific mandibular reconstruction with fibular free flaps based on the adequate safety, comparable stability, and analogous mechanobiology it presents compared with the locking system in a more manufacturable and economical way.


Assuntos
Retalhos de Tecido Biológico , Reconstrução Mandibular , Humanos , Estudos de Viabilidade , Mandíbula/cirurgia , Placas Ósseas , Análise de Elementos Finitos , Fenômenos Biomecânicos
2.
Comput Methods Programs Biomed ; 224: 107023, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35872386

RESUMO

BACKGROUND AND OBJECTIVE: Owing to the unexpected in vivo fracture failure of the original design, structural optimized patient-specific mandibular reconstruction plates (PSMRPs) were created to boost the biomechanical performance of bridging segmental bony defect in the mandibular reconstruction after tumor resection. This work aimed to validate the biomechanical benefit of the structural optimized PSMRPs relative to the original design and compare the biomechanical performance between PSMRP1 with generic contour customization and PSMRP2 with a tangent arc upper margin in mandibular angle region. METHODS: Finite Element Analysis (FEA) was used to evaluate the biomechanical behavior of mandibular reconstruction assemblies (MRAs) concerning these two structural optimized PSMRPs by simulating momentary left group clenching and incisal clenching tasks. Bonded contact was set between mandibular bone and fixation screws and between PSMRP and fixation screws in the MRA, while the frictionless connection was allocated between mandibular bone and PSMRP. The loads were applied on four principal muscles, including masseter, temporalis, lateral and medial pterygoid, whose magnitudes along the three orthogonal directions. The mandibular condyles were retrained in all three directions, and either the left molars or incisors area were restrained from moving vertically. RESULTS: The peak von Mises stresses of structural optimized PSMRPs (264 MPa, 296 MPa) were way lower than that of the initial PSMRP design (393 MPa), with 33 and 25% reduction during left group clenching. The peak magnitude of von Mises stress, minimum principal stress, and maximum principal strain of PSMRP1 (264 MPa, 254 MPa; -297 MPa, -285 MPa; 0.0020, 0.0020) was lower than that of PSMRP2 (296 MPa, 286 MPa; -319 MPa, -306 MPa; 0.0022, 0.0020), while the peak maximum principal stress of PSMRP1 (275 MPa, 257 MPa) was higher than that of PSMRP2 (254 MPa, 235 MPa) during both left group clenching and incisal clenching tasks. CONCLUSIONS: The structural optimized PSMRPs reveal their biomechanical advantage compared with the original design. The PSMRP1 presents better biomechanical performance to the patient-specific mandibular reconstruction than PSMRP2 as a result of its superior safety, preferable flexibility, and comparable stability. The PSMRP2 provides biomechanical benefit in reducing the maximum tension than PSMRP1, indicated by lower peak maximum principal stress, through tangent arc upper margin in mandibular angle region.


Assuntos
Reconstrução Mandibular , Fenômenos Biomecânicos , Placas Ósseas , Análise de Elementos Finitos , Humanos , Mandíbula/cirurgia , Estresse Mecânico
3.
Comput Biol Med ; 139: 105008, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34741907

RESUMO

BACKGROUND: A combination of short titanium plates fabricated using additive manufacturing (AM) provides multiple advantages for complete mandible reconstruction, such as the minimisation of inherent implant deformation formed during AM and the resulting clinical impact, as well as greater flexibility for surgical operation. However, the biomechanical feasibility of this strategy is still unclear, and therefore needs to be explored. METHOD: Three different combinations of short mandible reconstruction plates (MRPs) were customised considering implant deformation during the AM process. The resulting biomechanical performance was analysed by finite element analysis (FEA) and compared to a conventional single long MRP. RESULTS: The combination of a long plate and a short plate (Design 3 [LL61 mm/RL166 mm]) shows superior biomechanical properties to the conventional single long plate (Design 1 [TL246 mm]) and reveals the most reliable fixation stability among the three designs with short plates. Compared to conventional Design 1, Design 3 provides higher plate safety (maximum tensile stress on plates reduced by 6.3%), lower system fixation instability (relative total displacement reduced by 41.4%), and good bone segment stability (bone segment dislocation below 42.1 µm) under masticatory activities. CONCLUSIONS: Preclinical evidence supports the biomechanical feasibility of using short MRPs for complete mandible reconstruction. Furthermore, the results could also provide valuable information when treating other large-sized bone defects using short customised implants, expanding the potential of AM for use in implant applications.


Assuntos
Reconstrução Mandibular , Fenômenos Biomecânicos , Placas Ósseas , Análise de Elementos Finitos , Mandíbula/cirurgia , Estresse Mecânico
4.
J Mech Behav Biomed Mater ; 124: 104849, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34563812

RESUMO

Patient-specific mandibular reconstruction plate (PSMRP), as one of the patient-specific implants (PSIs), offers a host of benefits to mandibular reconstruction. Due to the limitation of fabricating screw hole threads in the PSMRP, 3D printed PSMRP is applied to the non-locking system directly in the mandibular reconstruction with bone graft regardless of the locking system. Since the conventional manual-bending reconstruction plate (CMBRP) provides better fixation in the locking system, it needs to be validated whether the locking PSMRP performs better than the non-locking PSMRP in the patient-specific mandibular reconstruction. Thereupon, the purpose of this study was to compare the biomechanical behavior between the locking and non-locking PSMRP. Finite element analysis (FEA) was used to conduct the biomechanical comparison between the locking PSMRP and non-locking PSMRP by simulating the momentary incisal clenching through static structural analysis. Mandible was reconstructed through the virtual surgical planning, and subsequently a 3D model of mandibular reconstruction assembly, including reconstructed mandible, PSMRP, and fixation screws, was generated and meshed for the following FEA simulations. In the form of equivalent von Mises stress, equivalent elastic strain, and total deformation, the locking PSMRP demonstrated its higher strengths of preferable safety, desirable flexibility, and anticipated stability compared with the non-locking PSMRP, indicated by much lower maximum stress, lower maximum strain and equivalent displacement. Locking PSMRP/screw system provides a better fixation effect to the patient-specific mandibular reconstruction than the non-locking one as a result of its productive fixation nature. FEA plays a paramount role in pre-validating the design of PSMRP through the biomechanical behavior evaluation in static structural analysis.


Assuntos
Reconstrução Mandibular , Fenômenos Biomecânicos , Placas Ósseas , Análise de Elementos Finitos , Fixação Interna de Fraturas , Humanos , Estresse Mecânico
5.
Curr HIV Res ; 19(2): 195-198, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33153422

RESUMO

BACKGROUND: Concurrence of talaromycosis, an infection caused by the opportunistic fungal pathogen Talaromyces marneffei and Kaposi sarcoma, a common vascular tumor, is a rare but severe medical condition in patients infected with the human immunodeficiency virus (HIV). Despite poor outcomes, the clinical characteristics and management strategies for HIV-infected patients with comorbid Kaposi sarcoma and talaromycosis have not been well documented. CASE PRESENTATION: A 33-year-old HIV-positive male patient presented to the Department of Infectious Diseases at Wenzhou Central Hospital with cough, sputum expectoration, hemoptysis, rashes on the feet and violaceous plaques in the oral cavity. Chest computed tomography (CT) showed bilateral nodules, patchy shadows and lymphadenectasis. Skin biopsy and histopathological examination indicated Kaposi sarcoma. T. marneffei was isolated from blood cultures and suggested talaromycosis. The patient's overall conditions significantly improved following initiation of combination antiretroviral therapy (cART) and chemotherapy for Kaposi sarcoma and antifungal treatment for talaromycosis. CONCLUSION: Severe medical conditions such as Kaposi sarcoma and talaromycosis may coexist in HIV-infected patients and pose an increased risk of mortality. Etiological diagnosis and treatment are the keys to the successful management of HIV-infected patients with these concurrent conditions.


Assuntos
Fármacos Anti-HIV/uso terapêutico , Antifúngicos/uso terapêutico , Infecções por HIV/complicações , Micoses/tratamento farmacológico , Micoses/etiologia , Sarcoma de Kaposi/tratamento farmacológico , Sarcoma de Kaposi/etiologia , Adulto , Comorbidade , Infecções por HIV/microbiologia , Infecções por HIV/virologia , Humanos , Masculino , Infecções Oportunistas/tratamento farmacológico , Infecções Oportunistas/etiologia , Resultado do Tratamento
6.
ACS Omega ; 4(21): 19238-19245, 2019 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-31763547

RESUMO

A strategy for the preparation of bioactive poly-ether-ether-ketone/hydroxyapatite (PEEK/HA) composites was proposed in this study with the aim of controlling the biological and mechanical properties of different parts of the composites. The strategy integrated solvent-based extrusion freeforming 3D printing technology in order to print high-resolution HA scaffolds and compression molding processes for the production of bioactive PEEK/HA composites. To this end, an optimized model, established using response surface methodology, was employed to optimize the extrusion process parameters on the basis of accurate characterization of the extrusion pressure, and the effects of the filament/pore sizes on the PEEK infiltration depth into the HA scaffold were investigated. The results of scanning electron microscopy and computed tomography analyses revealed that the PEEK/HA composites exhibited a uniform microstructure and a good interface between the HA filaments and the PEEK matrix following the optimization of the process parameters. The HA scaffolds were fully infiltrated by PEEK in both vertical and lateral directions with an infiltration depth of 3 mm while maintaining the HA network structure and uniformity. The biological and mechanical performance test results validated that the PEEK/HA composites possessed excellent biocompatibility as well as yields and compressive strengths within the range of human cortical bone suitable for load-bearing applications.

7.
J Biomater Sci Polym Ed ; 30(17): 1636-1657, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31393229

RESUMO

The chitosan/gelatin hydrogel incorporated with biphasic calcium phosphate nanoparticles (BCP-NPs) as scaffold (CGB) for bone tissue engineering was reported in this article. Such nanocomposite hydrogels were fabricated by using cycled freeze-thawing method, of which physicochemical and biological properties were regulated by adjusting the weight ratio of chitosan/gelatin/BCP-NPs. The needle-like BCP-NPs were dispersed into composites uniformly, and physically cross-linked with chitosan and gelatin, which were identified via Scanning Electron Microscope (SEM) images and Fourier Transform Infrared Spectroscopy (FT-IR) analysis. The porosity, equilibrium swelling ratio, and compressive strength of CGB scaffolds were mainly influenced by the BCP-NPs concentration. In vitro degradation analysis in simulated body fluids (SBF) displayed that CGB scaffolds were degraded up to at least 30 wt% in one month. Also, CCK-8 analysis confirmed that the prepared scaffolds had a good cytocompatibility through in culturing with bone marrow mesenchymal stem cells (BMSCs). Finally, In vivo animal experiments revealed that new bone tissue was observed inside the scaffolds, and gradually increased with increasing months, when implanted CGB scaffolds into large necrotic lesions of rabbit femoral head. The above results suggested that prepared CGB nanocomposites had the potential to be applied in bone tissue engineering.


Assuntos
Substitutos Ósseos/química , Quitosana/química , Gelatina/química , Hidroxiapatitas/química , Nanopartículas/química , Alicerces Teciduais/química , Animais , Regeneração Óssea , Linhagem Celular , Fêmur/lesões , Humanos , Hidrogéis/química , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais/citologia , Coelhos , Engenharia Tecidual
8.
Biophys J ; 114(11): 2743-2755, 2018 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-29874622

RESUMO

Extracellular matrix stiffness has a profound effect on the behavior of many cell types. Adherent cells apply contractile forces to the material on which they adhere and sense the resistance of the material to deformation-its stiffness. This is dependent on both the elastic modulus and the thickness of the material, with the corollary that single cells are able to sense underlying stiff materials through soft hydrogel materials at low (<10 µm) thicknesses. Here, we hypothesized that cohesive colonies of cells exert more force and create more hydrogel deformation than single cells, therefore enabling them to mechanosense more deeply into underlying materials than single cells. To test this, we modulated the thickness of soft (1 kPa) elastic extracellular-matrix-functionalized polyacrylamide hydrogels adhered to glass substrates and allowed colonies of MG63 cells to form on their surfaces. Cell morphology and deformations of fluorescent fiducial-marker-labeled hydrogels were quantified by time-lapse fluorescence microscopy imaging. Single-cell spreading increased with respect to decreasing hydrogel thickness, with data fitting to an exponential model with half-maximal response at a thickness of 3.2 µm. By quantifying cell area within colonies of defined area, we similarly found that colony-cell spreading increased with decreasing hydrogel thickness but with a greater half-maximal response at 54 µm. Depth-sensing was dependent on Rho-associated protein kinase-mediated cellular contractility. Surface hydrogel deformations were significantly greater on thick hydrogels compared to thin hydrogels. In addition, deformations extended greater distances from the periphery of colonies on thick hydrogels compared to thin hydrogels. Our data suggest that by acting collectively, cells mechanosense rigid materials beneath elastic hydrogels at greater depths than individual cells. This raises the possibility that the collective action of cells in colonies or sheets may allow cells to sense structures of differing material properties at comparatively large distances.


Assuntos
Mecanotransdução Celular , Linhagem Celular Tumoral , Elasticidade , Matriz Extracelular/metabolismo , Humanos , Modelos Biológicos , Pseudópodes/metabolismo , Análise de Célula Única , Quinases Associadas a rho/metabolismo
9.
Regen Med ; 9(4): 535-49, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25159068

RESUMO

Additive manufacturing (AM) is a broad term encompassing 3D printing and several other varieties of material processing, which involve computer-directed layer-by-layer synthesis of materials. As the popularity of AM increases, so to do expectations of the medical therapies this process may offer. Clinical requirements and limitations of current treatment strategies in bone grafting, spinal arthrodesis, osteochondral injury and treatment of periprosthetic joint infection are discussed. The various approaches to AM are described, and the current state of clinical translation of AM across these orthopedic clinical scenarios is assessed. Finally, we attempt to distinguish between what AM may offer orthopedic surgery from the hype of what has been promised by AM.


Assuntos
Substitutos Ósseos , Impressão Tridimensional , Fusão Vertebral/métodos , Humanos
10.
Nutrition ; 30(5): 584-9, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24698350

RESUMO

OBJECTIVE: According to the "antioxidants network" theory, the present study was conducted to evaluate the regulation of an antioxidant blend on intestinal redox status and major microbiota of early-weaned piglets. METHODS: Piglets from 15 litters were randomly allocated by litter to the control group (suckling normally, fed the basal diet, n = 5), the weaning group (weaned at age 21 d, fed the basal diet, n = 5), and the repair group (weaned at age 21 d, fed the basal diet supplemented with an antioxidant blend, n = 5). The redox status and major microbiota in jejunum and colon tracts of 24-d-old piglets were detected, respectively. RESULTS: Early weaning resulted in significant decreases in jejunum and colon antioxidant capacities, Lactobacillus and Bifidobacterium counts, and significant increases in levels of jejunum malondialdehyde, colon hydroxyl radicals, jejunum and colon H2O2, and Escherichia coli counts in piglets. The observed imbalance of the intestinal redox status and microbiota was significantly restored by the antioxidant blend. Interestingly, intestinal selected antioxidative items presented a positive correlation with potential beneficial bacteria and a negative correlation with E. coli. Nevertheless, selected oxidative items and the bacteria presented an inverse relationship in piglets. CONCLUSION: Supplementation of the antioxidant blend effectively restored intestinal redox status and microbiota balance in the porcine intestine in response to early weaning stress, enhancing intestinal health and function of piglets.


Assuntos
Antioxidantes/farmacologia , Bactérias/efeitos dos fármacos , Colo/efeitos dos fármacos , Suplementos Nutricionais , Jejuno/efeitos dos fármacos , Microbiota/efeitos dos fármacos , Desmame , Animais , Ácido Ascórbico/farmacologia , Bactérias/metabolismo , Camellia sinensis/química , Colo/metabolismo , Colo/microbiologia , Contagem de Colônia Microbiana , Escherichia coli , Peróxido de Hidrogênio/metabolismo , Radical Hidroxila/metabolismo , Jejuno/metabolismo , Jejuno/microbiologia , Malondialdeído/metabolismo , Oxirredução , Polifenóis/farmacologia , Suínos , Vitamina E/farmacologia , Leveduras/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA