Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Skeletal Radiol ; 42(3): 347-52, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22829026

RESUMO

OBJECTIVE: To create 3DMR osseous models of the shoulder similar to 3DCT models using a gradient-echo-based two-point/Dixon sequence. MATERIALS AND METHODS: CT and 3TMR examinations of 7 cadaveric shoulders were obtained. Glenoid defects were created in 4 of the cadaveric shoulders. Each MR study included an axial Dixon 3D-dual-echo-time T1W-FLASH (acquisition time of 3 min/30 s). The water-only image data from the Dixon sequence and CT data were post-processed using 3D software. The following measurements were obtained on the shoulders: surface area (SA), height/width of the glenoid and humeral head, and width of the biceps groove. The glenoid defects were measured on imaging and compared with measurements made on en face digital photographs of the glenoid fossae (reference standard). Paired t tests/ANOVA were used to assess the differences between the imaging modalities. RESULTS: The differences between the glenoid and humeral measurements were not statistically significant (cm): glenoid SA 0.12 ± 0.04 (p = 0.45) and glenoid width 0.13 ± 0.06 (p = 0.06) with no difference in glenoid height measurement; humeral head SA 0.07 ± 0.12 (p = 0.42), humeral head height 0.03 ± 0.06 (p = 0.42), humeral head width 0.07 ± 0.06(p = 0.18), and biceps groove width 0.02 ± 0.01 (p = 0.07). The mean/standard deviation difference between the reference standard and 3DMR measurements was 0.25 ± 0.96 %/0.30 ± 0.14 mm; 3DCT 0.25 ± 0.96 /0.75 ± 0.39 mm. There was no statistical difference between the measurements obtained on 3DMR and 3DCT (percentage, p = 0.45; mm, p = 0.20). CONCLUSION: Accurate 3D osseous models of the shoulder can be produced using a 3D two-point/Dixon sequence and can be added to MR examinations with a minor increase in imaging time, used to quantify glenoid loss, and may eliminate the need for pre-surgical CT examinations.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Procedimentos de Cirurgia Plástica/métodos , Articulação do Ombro/patologia , Articulação do Ombro/cirurgia , Cirurgia Assistida por Computador/métodos , Algoritmos , Cadáver , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Cancer Res ; 65(22): 10149-53, 2005 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-16287997

RESUMO

Magnetic resonance spectroscopic imaging has been used to follow glutathione metabolism and evaluate glutathione heterogeneity in intact tumor tissue. Stable isotope-labeled glutathione was detected in s.c. implanted fibrosarcoma tumors in anesthetized rats following infusion of [2-13C]glycine. Using 1H-decoupled 13C magnetic resonance spectroscopy, the appearance of [2-13C]glycine at 42.4 ppm and the subsequent incorporation of this isotope label into the glycyl residue of glutathione at 44.2 ppm can be detected. The identity and relative concentrations of labeled metabolites observed in the in vivo spectrum were confirmed in studies of tissue extracts. The high level of isotopic enrichment and the concentration of glutathione in tumor tissue allow for collection of spatially localized spectra using 13C chemical shift imaging methods. These data provide the first direct images of glutathione in intact tumor tissue and show metabolic heterogeneity. This method may lead to the ability to monitor changes in tumor tissue redox state that may ultimately affect diagnosis, monitoring, and treatment.


Assuntos
Fibrossarcoma/metabolismo , Glutationa/metabolismo , Ressonância Magnética Nuclear Biomolecular/métodos , Animais , Radioisótopos de Carbono , Feminino , Glutationa/biossíntese , Glicina/metabolismo , Prótons , Ratos , Ratos Endogâmicos F344
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA