Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Clin Oral Investig ; 28(8): 417, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38972945

RESUMO

OBJECTIVES: The treatment of fractures prioritizes the restoration of functionality through the realignment of fractured segments. Conventional methods, such as titanium plates, have been employed for this purpose; however, certain limitations have been observed, leading to the development of patient-specific plates. Furthermore, recent advancements in digital technology in dentistry enable the creation of virtual models and simulations of surgical procedures. The aim was to assess the clinical effectiveness of patient-specific plates utilizing digital technology in treating mandibular fractures compared to conventional titanium plates. MATERIALS AND METHODS: Twenty patients diagnosed with mandibular fractures were included and randomly assigned to either the study or control groups. The surgical procedure comprised reduction and internal fixation utilizing patient-specific plates generated through virtual surgery planning with digital models for the study group, while the control group underwent the same procedure with conventional titanium plates. Assessment criteria included the presence of malunion, infection, sensory disturbance, subjective occlusal disturbance and occlusal force in functional maximum intercuspation (MICP). Statistical analysis involved using the Chi-square test and one-way repeated measures analysis of variance. RESULTS: All parameters showed no statistically significant differences between the study and control groups, except for the enhancement in occlusal force in functional MICP, where a statistically significant difference was observed (p = 0.000). CONCLUSION: Using patient-specific plates using digital technology has demonstrated clinical effectiveness in treating mandibular fractures, offering advantages of time efficiency and benefits for less experienced surgeons. CLINICAL RELEVANCE: Patient-specific plates combined with digital technology can be clinically effective in mandibular fracture treatment.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas Mandibulares , Titânio , Humanos , Fraturas Mandibulares/cirurgia , Titânio/química , Masculino , Feminino , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Adulto , Resultado do Tratamento , Pessoa de Meia-Idade , Desenho Assistido por Computador , Cirurgia Assistida por Computador/métodos
2.
J Dent ; 146: 105061, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38729289

RESUMO

OBJECTIVES: Orthognathic surgery (OS) has evolved with technological advancements, notably through the implementation of computer-assisted orthognathic surgery (CAOS). This article aims to elucidate various types of CAOS and their efficiency and accuracy, supplemented by a thorough literature review focusing on their clinical applications in South Korea. STUDY SELECTION, DATA, AND SOURCES: A comprehensive search strategy was employed, including systematic reviews, meta-analyses, randomized controlled trials, and observational studies published until December 2023 in the PubMed, MEDLINE, and Google Scholar databases. The literature search was limited to articles written in English. RESULTS: Static CAOS demonstrated high precision, reduced operative time, and high accuracy, suggesting its potential reliability in orthognathic procedures. Dynamic CAOS presented a promising avenue for exploration, showing an accuracy comparable to that of traditional methods. The critical considerations for CAOS include accuracy, time efficiency, and cost-effectiveness. Recent studies have indicated advancements in the time efficiency of static CAOS. Static CAOS requires less equipment and is more cost-effective than dynamic CAOS. CONCLUSIONS: CAOS offers clear advantages over conventional OS in terms of surgical convenience and accuracy in implementing the surgical plan. To achieve recognition as the gold standard method for maxillofacial deformity treatment, CAOS must overcome its limitations and undergo continuous verification via well-designed studies. CLINICAL SIGNIFICANCE: The introduction of CAOS, mainly static CAOS with high precision and reduced surgical time, signifies a notable advancement in OS. However, rigorous studies are warranted to validate CAOS as the gold standard for treating maxillofacial deformities.


Assuntos
Procedimentos Cirúrgicos Ortognáticos , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , República da Coreia , Duração da Cirurgia
3.
Bioengineering (Basel) ; 11(4)2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38671740

RESUMO

With the growing demand for orthognathic surgery and other facial treatments, the accurate identification of anatomical landmarks has become crucial. Recent advancements have shifted towards using three-dimensional radiologic analysis instead of traditional two-dimensional methods, as it allows for more precise treatment planning, primarily relying on direct identification by clinicians. However, manual tracing can be time-consuming, mainly when dealing with a large number of patients. This study compared the accuracy and reliability of identifying anatomical landmarks using artificial intelligence (AI) and manual identification. Thirty patients over 19 years old who underwent pre-orthodontic and orthognathic surgery treatment and had pre-orthodontic three-dimensional radiologic scans were selected. Thirteen anatomical indicators were identified using both AI and manual methods. The landmarks were identified by AI and four experienced clinicians, and multiple ANOVA was performed to analyze the results. The study results revealed minimal significant differences between AI and manual tracing, with a maximum deviation of less than 2.83 mm. This indicates that utilizing AI to identify anatomical landmarks can be a reliable method in planning orthognathic surgery. Our findings suggest that using AI for anatomical landmark identification can enhance treatment accuracy and reliability, ultimately benefiting clinicians and patients.

4.
Bioengineering (Basel) ; 10(9)2023 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-37760107

RESUMO

Recombinant human bone morphogenetic protein-2 (rhBMP-2) has shown potential in maxillofacial surgery owing to its osteoinductive properties. However, concerns about its safety and high cost have limited its widespread use. This review presents the status of rhBMP-2 use in maxillofacial surgery, focusing on its clinical application, efficacy, safety, and limitations. Studies have demonstrated rhBMP-2's potential to reduce donor site morbidity and increase bone height in sinus and ridge augmentation; however, it may not outperform autogenous bone grafts. In medication-related osteonecrosis of the jaw treatment, rhBMP-2 has been applied adjunctively with promising results, although its long-term safety requires further investigation. However, in maxillofacial trauma, its application is limited to the restoration of large defects. Safety concerns include postoperative edema and the theoretical risk of carcinogenesis. Although postoperative edema is manageable, the link between rhBMP-2 and cancer remains unclear. The limitations include the lack of an ideal carrier, the high cost of rhBMP-2, and the absence of an optimal dosing regimen. In conclusion, rhBMP-2 is a promising graft material for maxillofacial surgery. However, it has not yet become the gold standard owing to safety and cost concerns. Further research is required to establish long-term safety, optimize dosing, and develop better carriers.

5.
Bioengineering (Basel) ; 10(8)2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37627799

RESUMO

Maxillofacial skeletal surgery often involves the use of patient-specific implants. However, errors in obtaining patient data and designing and manufacturing patient-specific plates and guides can occur even with accurate virtual surgery. To address these errors, bespoke Snowman plates were designed to allow movement of the mandible. This study aimed to compare the stability of bespoke four-hole miniplates with that of a bespoke Snowman plate for bilateral sagittal split ramus osteotomy (SSRO), and to present a method to investigate joint cavity changes, as well as superimpose virtual and actual surgical images of the mandible. This retrospective study included 22 patients who met the inclusion criteria and underwent orthognathic surgery at a university hospital between 2015 and 2018. Two groups were formed on the basis of the plates used: a control group with four-hole bespoke plates and a study group with bespoke Snowman plates. Stability was assessed by measuring the condyle-fossa space and superimposing three-dimensional virtual surgery images on postoperative cone-beam computed tomography (CBCT) scans. No significant differences were observed in the condyle-fossa space preoperatively and 1 year postoperatively between the control and study groups. Superimposing virtual surgery and CBCT scans revealed minimal differences in the landmark points, with no variation between groups or timepoints. The use of bespoke Snowman plates for stabilizing the mandible following SSRO exhibited clinical stability and reliability similar to those with bespoke four-hole plates. Additionally, a novel method was introduced to evaluate skeletal stability by separately analyzing the condyle-fossa gap changes and assessing the mandibular position.

6.
J Clin Med ; 10(8)2021 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-33918920

RESUMO

OBJECTIVE: Orthognathic surgery (OGS) is a surgical intervention that corrects dentofacial deformities through the movement of maxillary and mandibular segments to achieve adequate masticatory function, joint health, and facial harmony. However, some patients present with occlusal discrepancies, condylar sag, and/or temporomandibular disorders after OGS. Various methods have been employed to solve these problems after surgery. This study aimed to evaluate the effectiveness of early screw removal in patients with occlusal discrepancies after OGS using three-dimensional cone-beam computed tomography (CBCT). METHODS: In 44 patients with dentofacial deformities, patient-customized OGSs with customized plates were performed to correct facial deformities using customized guides with computer-aided surgical simulation. Of the 44 patients, eight patients complained of occlusal discrepancies and temporomandibular disorders after OGS. These eight patients underwent screw removal under local anesthesia around four weeks. The temporomandibular joint spaces at three time points (pre-surgical, post-surgical, and after screw removal) in the sagittal and coronal planes were compared using CBCT. RESULTS: Eight patients showed an increase in joint space on CBCT images immediately after surgery (T1), but after early screw removal (T2), these spaces almost returned to their pre-surgical state, and the temporomandibular joint problem disappeared. CONCLUSIONS: The removal of screws located in the distal segment under local anesthesia between three and four weeks post-surgically may be a treatment option for patients with post-OGS occlusal discrepancies, condylar sag, and/or temporomandibular disorder.

7.
Ann Dermatol ; 26(2): 184-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24882972

RESUMO

BACKGROUND: Surgery for bromhidrosis has a high risk of complications such as hematoma and necrosis. New nonsurgical methods may reduce the burden on surgery and the risks for the patient. OBJECTIVE: This study was performed to evaluate the efficacy and side-effects of the 1,444 nm Nd:YAG interstitial laser for treating axillary bromhidrosis. METHODS: Eighteen bromhidrosis patients were treated with a 1,444 nm Nd:YAG laser at Korea University Ansan Hospital. The post-treatment follow-up was 6 months. After the procedure, we confirmed apocrine gland destruction through histopathological examination. At each follow-up, we measured the severity of the remaining odor, postoperative pain, degree of mobility restriction, and overall satisfaction. RESULTS: After 180 days of follow-up, malodor elimination was good in 20 axillae, fair in 12 axillae, and poor in four axillae. At the end point of the study, 14 patients were totally satisfied with the laser treatment, three patients were partially satisfied, and one patient was disatisfied. Pain and limitation of mobility were significantly reduced within 1 week post-operatively, and were almost resolved within 4 weeks post-operatively. A histopathological examination revealed decreased density and significant alterations to the apocrine glands. CONCLUSION: Subdermal coagulation treatment with a 1,444 nm Nd:YAG interstitial laser may be a less invasive and effective therapy for axillary bromhidrosis.

8.
Ann Dermatol ; 26(1): 99-102, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24648694

RESUMO

Bromhidrosis is a disease presenting as malodor caused by interaction between the discharge of apocrine glands and bacteria. The main therapeutic modalities are applying topical agents, liposuction surgery, and elective surgery. Among these, elective surgery is reported to be most effective. However, the efficiency largely depends on surgical technique. Additionally, other side effects, such as hematoma and scarring, are occasionally reported. Currently, CO2 laser and 1,064 nm Nd:YAG laser therapy are used, but as the wavelength is not specific to apocrine glands, these laser therapies have certain limitations. Recently, a 1,444 nm wavelength Accusculpt™ laser (LutronicCorp., Seoul, Korea) has been developed which is now commonly used for facial fat plasty and laser liposuction therapy. The use of this laser for bromhidrosis therapy targeting apocrine sweat glands is currently being discussed. Still, no studies on practical clinical use and side effects of this 1,444 nm wavelength laser have been published. In this report, we treated one bromhidrosis patient with 1,444 nm wavelength Accusculpt™ laser therapy on one side while conventional surgery was performed on the other side using a modified Inaba's method. We compared the efficacy of this laser therapy to the surgical modality by measuring malodor severity and overall satisfaction by questionnaire. We also checked for other complications and recurrence for 12 months after the treatment. This patient was largely satisfied as it has a much shorter down time with the same therapeutic outcome. As subdermal coagulation treatment by 1,444 nm Nd:YAG laser may be less invasive but effective therapy, we would like to recommend this modality as a possible treatment option.

14.
Ophthalmic Plast Reconstr Surg ; 27(3): e79-81, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-20924299

RESUMO

Mohs micrographic surgery of the lower eyelid poses a risk of ectropion. Even though the lower eyelid is a very frequent location for basal cell carcinoma, prevention techniques for ectropion after Mohs micrographic surgery have rarely been introduced. After Mohs micrographic surgery of the lower eyelid, the authors applied a barbed suture suspension technique for the prevention of lower eyelid ectropion. Following primary wound closure, barbed sutures were prepared by cutting one side of a 4-0 Prolene suture and applied around the lower eyelid. Sutures were maintained for 7 days and then removed. Evaluation 10 weeks after surgery found that ectropion had been minimized or prevented entirely.


Assuntos
Ectrópio/prevenção & controle , Pálpebras/cirurgia , Cirurgia de Mohs , Complicações Pós-Operatórias/prevenção & controle , Técnicas de Sutura , Blefaroplastia/métodos , Carcinoma Basocelular/patologia , Carcinoma Basocelular/cirurgia , Ectrópio/etiologia , Neoplasias Palpebrais/patologia , Neoplasias Palpebrais/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Polipropilenos , Suturas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA