Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Med Dosim ; 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37858458

RESUMO

This study aims to establish a delineation guideline for the contouring of the hypoglossal nerve by dividing the nerve into different segments, and to test the possibility of a radiation dose reduction to the hypoglossal nerve in NPC patients receiving radiotherapy. Twenty NPC patients were selected arbitrarily. The hypoglossal nerves were delineated using anatomic landmarks and divided into the cisternal, intracanalicular, carotid, and transverse segments. The tumor coverage by radiation and dose-volume parameters of the nerve with and without various dose constraints to the hypoglossal nerve were compared. The hypoglossal nerve, which is invisible on CT images, can be delineated accurately with the assistance of several anatomic landmarks. Without a dose constraint to the hypoglossal nerve, the carotid space, intracanalicular, and transverse segments had high radiation dose-volumes. The dose-volume to the nerve, however, can be reduced when the nerve was defined and a dose constraint was given. The delineation of the hypoglossal nerve with its different segments is feasible. The carotid space, intracanalicular, and transverse segments received the highest dose, where the nerve damage was most likely located. The dose to the nerve can be reduced to less than 70 Gy using the intensity-modulated radiotherapy technique.

2.
Med Dosim ; 42(4): 251-267, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28733115

RESUMO

The purpose of this study was to realize the processing of dose distribution of RGK at the treatment isocenter at any gantry rotational angle by using an analytic geometry method to avoid inadequate arc therapy angles when implementing the treatment plan. Gaf chromic film was used for dose evaluation. A calibration curve was first obtained using linear accelerator irradiation. The 50% dose relative to the central axis at fixed gantry angles at the x-, y- and z-axes was obtained using Gaf chromic film and was compared to the analytic geometry method. The full width half maximum (FWHM) on the x-, y- and z-axes was predicted for the RGK dose distribution characteristic analysis. The FWHM on the x-, y-, and z-axes varies with different gantry and rotational plate angles. The most dramatic intersection variation appeared at a static gantry angle of 25°. The ratio of the FWHM of the y- and z-axes to that of the x-axis was up to 9 and 10. The geometric analytic method can be used for an accurate analysis of dose distribution in RGK replacing the actual film exposure experiment. It is essential to select the best arc irradiation angle to prescribe the dose to avoid excess irradiation of normal tissue. The geometric method used in this study can also be applied for rotational arc therapy dose analysis such as tomotherapy, linear-based stereotactic radiotherapy, or volume matrices arc therapy.


Assuntos
Radiocirurgia , Dosagem Radioterapêutica , Calibragem , Humanos , Rotação
3.
J Appl Clin Med Phys ; 17(1): 428­439, 2016 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-26894355

RESUMO

The construction of a conventional prostate needle (seeds) implant template restricts needles tilting or incline insertion when it is necessary to approach a seminal vesicle or to avoid the obstruction of symphysis pubis. To overcome the disadvantages of conventional templates, we developed a special template for guiding needles incline insertion and fixation for prostate needle implant. Phantom needles implantation was performed. Two acrylic boards, each 7.5 cm in width by 7.5 cm in length and 0.5 cm thickness, were drilled with a set of domed holes and cones with embedded template ball inside this combination to provide firm grip and fixation in prostate needle implantation. The specially designed domed-cones combination acrylic board provides a needle of up to 60° rotation flexibility application. Some areas that could not be covered in a conventional parallel needle holes template could now be covered by using this new template. The covering index of prostate radiation dosage is up to 84.5%. The specially designed domed-cones acrylic board combination provides not only a reliable means of needle fixation and rotational function, but also a superior dose distribution in the anterior portion of the prostate and good coverage of a seminal vesicle. This special template is a feasible design for prostate needles or seeds implant brachytherapy.


Assuntos
Braquiterapia , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Próteses e Implantes , Humanos , Masculino , Agulhas , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Rotação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA