Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 19671, 2023 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-37952046

RESUMO

Impaired kidney function is often associated with acute decompensation of chronic heart failure and portends a poor prognosis. Unfortunately, current data have demonstrated worse survival in patients with acute kidney injury than in patients with chronic kidney disease during durable LVAD placement as bridge therapy. Furthermore, end-stage heart failure patients undergoing combined heart-kidney transplantation have poorer short- and long-term survival than heart transplants alone. We evaluated the kidney function recovery in our heart failure population awaiting heart transplantation at our institution, supported by temporary Mechanical Circulatory Support (tMCS) with Impella 5.5. The protocol (#22004000) was approved by the Mayo Clinic institutional review board, after which we performed a retrospective review of all patients with acute on chronic heart failure and kidney disease in patients considered for only heart and kidney combined organ transplant and supported by tMCS between January 2020 and February 2021. Hemodynamic and kidney function trends were recorded and analyzed before and after tMCS placement and transplantation. After placement of tMCS, we observed a trend towards improvement in creatinine, Fick cardiac index, mixed venous saturation, and glomerular filtration rate (GFR), which persisted through transplantation and discharge. The average duration of support with tMCS was 16.5 days before organ transplantation. The median pre-tMCS creatinine was 2.1 mg/dL (IQR 1.75-2.3). Median hematocrit at the time of tMCS placement was 32% (IQR 32-34), and the median estimated glomerular filtration rate was 34 mL/min/BSA (34-40). The median GFR improved to 44 mL/min/BSA (IQR 45-51), and serum creatinine improved to 1.5 mg/dL (1.5-1.8) after tMCS. Median discharge creatinine was 1.1 mg/dL (1.19-1.25) with a GFR of 72 (65-74). None of these six patients supported with tMCS required renal replacement therapy after heart transplantation. Early adoption of Impella 5.5 in this patient population resulted in renal recovery without needing renal replacement therapies or dual organ transplantation and should be further evaluated.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Insuficiência Renal Crônica , Humanos , Creatinina , Insuficiência Cardíaca/cirurgia , Rim/fisiologia , Insuficiência Renal Crônica/cirurgia
2.
J Card Surg ; 37(4): 732-738, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35060167

RESUMO

BACKGROUND: We aimed to investigate the short-term outcomes of heart transplant patients who underwent SherpaPak™ donor organ preservation. METHOD: We prospectively collected the data of patients who underwent heart transplantation using SherpaPak™ system for donor organ transportation from February 2020 to March 2021. Donor and recipient demographic data, preoperative and postoperative echocardiographic and hemodynamic parameters, total ischemic time and SherpaPak temperatures, vasoactive inotropic scores (VIS), primary graft dysfunction (PGD) status, intensive care unit stay, complications, and mortality during follow-up were assessed. RESULTS: A total of 39 consecutive heart transplant patients with SherpaPak system were included in the study. The mean donor age was 32.2 ± 6.7 (range: 16-46). The mean recipient age was 57.5 ± 12 (range: 19-73). The mean preoperative ejection fraction (EF) was 23.7 ± 15.4 (range: 5-75). All recipients underwent a standard bicaval technique for orthotopic heart implantation. The mean total ischemic time was 230.1 ± 41 (range: 149-342) min. The mean Sherpa temperature was 5.6 ± 0.8°C (range: 3.7-7.5). The mean VIS was 10.2 ± 6.5 (range: 2-32). The number of mild PGD was 5 (14.7%), and moderate PGD was 4 (11.8%). There was no severe PGD. The postoperative EF was 64.3 ± 5.5 (range: 50-78). Mean intubation time was 47.4 ± 64 (range: 8-312, median: 22) h. The mean time of intensive care unit stay was 6.3 ± 5 (range: 2-31, median: 5) days. Two patients required chest revision (5.8%), two patients had lung infection (5.8%). Two patients had a stroke (5.8%). There was no mortality. CONCLUSION: Using the SherpaPak system during heart transplantation is safe and not associated with significant recipient morbidity. None of the recipients experienced significant PGD and mortality.


Assuntos
Transplante de Coração , Disfunção Primária do Enxerto , Transplante de Coração/efeitos adversos , Humanos , Preservação de Órgãos , Disfunção Primária do Enxerto/etiologia , Disfunção Primária do Enxerto/prevenção & controle , Estudos Retrospectivos , Temperatura , Doadores de Tecidos
3.
J Card Surg ; 35(3): 725-728, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32017259

RESUMO

Patients undergoing heart-kidney transplants who have primary graft dysfunction (PGD) of the heart are at risk of losing both organs, which may cause reluctance on the part of the transplant team to proceed with transplanting the kidney while the transplanted heart is being supported by mechanical device. We describe a case series in which 2 patients received kidney transplants while on veno-arterial ECMO support for PGD after heart transplant. Both patients are alive more than 1 year following transplant, with good cardiac and renal function and no signs of cardiac rejection. Kidney transplant surgery is safe for patients on veno-arterial ECMO support for cardiac PGD. It allows the heart recipient to receive a kidney from the same donor with both immunologic and survival advantages.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração/métodos , Transplante de Rim/métodos , Disfunção Primária do Enxerto/terapia , Aloenxertos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA