1.
Ann Cardiothorac Surg ; 13(3): 283-290, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38841085

RESUMO

Background: The labeled sizes of surgical valve prostheses and their discordance with the physical internal valve orifice sizes has long been a controversy in the cardiac surgery community, leading many to believe it to be a contributing factor in prosthesis-patient mismatch following valvular replacement surgery. In an attempt to address this issue, the International Organization for Standardization (ISO) 5840-2:2021 standard for surgical valve prostheses recommends that a new sizing parameter, namely, the effective orifice diameter, be provided in labeling by all manufacturers as an indicator of the true flow-passing capacity of a prosthetic valve. Methods: The ISO Cardiac Valves Working Group conducted a multi-laboratory round-robin study to investigate whether the effective orifice diameter of a prosthetic surgical valve could be derived repeatably and reproducibly through steady forward-flow testing. A total of seven valve models, each with multiple sizes, were tested, including a mechanical heart valve and multiple biological heart valves. Results: The round-robin study confirmed that the steady forward-flow test had good intra-laboratory repeatability and inter-laboratory reproducibility in deriving the effective orifice diameters of surgical valve prostheses. On average, among the participating laboratories, the experimentally derived effective orifice diameter of a prosthetic heart valve was 3-12 mm smaller than its labeled size. Conclusions: The effective orifice diameter provides better characterization of the hydrodynamic characteristics of a surgical valve prosthesis and can be derived using a validated steady forward-flow test method. This new sizing parameter will soon be adopted by surgical valve manufacturers and provided in device labeling to inform valve selection by surgeons.

2.
J Thorac Cardiovasc Surg ; 166(4): e130-e141, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37086238

RESUMO

BACKGROUND: Leaflet thrombosis after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) may be caused by blood flow stagnation in the native and neosinus regions. To date, aortic leaflet laceration has been used to mitigate coronary obstruction following TAVR; however, its influence on the fluid mechanics of the native and neosinus regions is poorly understood. This in vitro study compared the flow velocities and flow patterns in the setting of SAVR vs TAVR with and without aortic leaflet lacerations. METHODS: Two valves, (23-mm Perimount and 26-mm SAPIEN 3; Edwards Lifesciences) were studied in a validated mock flow loop under physiologic conditions. Neosinus and native sinus fluid mechanics were quantified using particle image velocimetry in the left and noncoronary cusp, with an increasing number of aortic leaflets lacerated or removed. RESULTS: Across all conditions, SAVR had the highest average sinus and neosinus velocities, and this value was used as a reference to compare against the TAVR conditions. With an increasing number of leaflets lacerated or removed with TAVR, the average sinus and neosinus velocities increased from 25% to 70% of SAVR flow (100%). Diastolic velocities were substantially augmented by leaflet laceration. Also, the shorter frame of the SAVR led to higher flow velocities compared with the longer frame of the TAVR, even after complete leaflet removal. CONCLUSIONS: Leaflet laceration augmented TAVR native and neosinus flow fields, approaching that of SAVR. These findings may have potential clinical implications for the use of single or multiple leaflet lacerations to reduce leaflet thrombosis and thus potentially improve TAVR durability.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Lacerações , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Lacerações/complicações , Lacerações/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Trombose/etiologia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
3.
Artigo em Inglês | MEDLINE | ID: mdl-36153166

RESUMO

OBJECTIVE: Implantation of a transcatheter valve-in-mitral annular calcification (ViMAC) has emerged as an alternative to traditional surgical mitral valve (MV) replacement. Previous studies evaluating ViMAC aggregated transseptal, transapical, and transatrial forms of the procedure, leaving uncertainty about each technique's advantages and disadvantages. Thus, we sought to evaluate clinical outcomes specifically for transatrial ViMAC from the largest multicenter registry to-date. METHODS: Patients with symptomatic MV dysfunction and severe MAC who underwent ViMAC were enrolled from 12 centers across the United States and Europe. Clinical characteristics, procedural details, and clinical outcomes were abstracted from the electronic record. The primary end point was all-cause mortality. RESULTS: We analyzed 126 patients who underwent ViMAC (median age 76 years [interquartile range {IQR}, 70-82 years], 28.6% female, median Society of Thoracic Surgeons score 6.8% [IQR, 4.0-11.4], and median follow-up 89 days [IQR, 16-383.5]). Sixty-one (48.4%) had isolated mitral stenosis, 25 (19.8%) had isolated mitral regurgitation (MR), and 40 (31.7%) had mixed MV disease. Technical success was achieved in 119 (94.4%) patients. Thirty (23.8%) patients underwent concurrent septal myectomy, and 8 (6.3%) patients experienced left ventricular outflow tract obstruction (7/8 did not undergo myectomy). Five (4.2%) patients of 118 with postprocedure echocardiograms had greater than mild paravalvular leak. Thirty-day and 1-year all-cause mortality occurred in 16 and 33 patients, respectively. In multivariable models, moderate or greater MR at baseline was associated with increased risk of 1-year mortality (hazard ratio, 2.31; 95% confidence interval, 1.07-4.99, P = .03). CONCLUSIONS: Transatrial ViMAC is safe and feasible in this selected, male-predominant cohort. Patients with significant MR may derive less benefit from ViMAC than patients with mitral stenosis only.

4.
Ann Thorac Surg ; 114(3): 841-847, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35120878

RESUMO

BACKGROUND: Despite favorable short-term outcomes, Fontan palliation is associated with comorbidities and diminished quality of life (QOL) in the years after completion. We hypothesized that poor Fontan hemodynamics and ventricular function are associated with worse QOL. METHODS: This was a single-center study of Fontan survivors aged more than 12 years. Subjects completed a cardiac magnetic resonance scan and QOL questionnaire. Cardiac magnetic resonance-derived variables included Fontan geometry, and hemodynamics. Computational fluid dynamics simulations quantified power loss, pressure drop, and total cavopulmonary connection resistance across the Fontan. Quality of life was assessed by completion of the Pediatric Quality of Life Inventory. Longitudinal and cross-sectional comparisons were made between cardiac magnetic resonance and computational fluid dynamics parameters with patient-reported QOL. RESULTS: We studied 77 Fontan patients, median age 19.7 years (interquartile range, 17.1 to 23.6), median time from Fontan completion 16 years (interquartile range, 13 to 20). Longitudinal data were available for 48 patients; median time between cardiac magnetic resonance and QOL was 8.1 years (interquartile range, 7 to 9.4). Median patient-reported Pediatric Quality of Life Inventory total score was 80 (interquartile range, 67.4 to 88). Greater power loss and smaller left pulmonary artery diameter at baseline were associated with worse QOL at follow-up. Greater pressure drop was associated with worse QOL at the same time point. CONCLUSIONS: For Fontan survivors, measures of computational fluid dynamics hemodynamics and geometry are associated with worse QOL. Interventional strategies targeted at optimizing the Fontan may improve QOL.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Adolescente , Adulto , Criança , Estudos Transversais , Cardiopatias Congênitas/cirurgia , Hemodinâmica , Humanos , Artéria Pulmonar/cirurgia , Qualidade de Vida , Adulto Jovem
5.
Ann Thorac Surg ; 113(4): 1378-1384, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34958769

RESUMO

PURPOSE: This study examined changes in force distribution between the neochordae corresponding to different ventricular anchor locations. DESCRIPTION: Seven porcine mitral valves were mounted in a left heart simulator. Neochordae (expanded polytetrafluoroethylene) originated from either a simulated left ventricular apex, papillary muscle base, or papillary muscle tip location. The neochordae were attached at three sites along the P2 leaflet segment: P2Lateral; P2Center, and P2Medial. Mitral regurgitation was induced by cutting posterior leaflet P2 marginal chordae. The forces on each neochord required to restore normal mitral valve coaptation were quantified for different ventricular anchoring origins and leaflet insertion sites. EVALUATION: The results showed that under both normotensive and hypertensive conditions, the force exerted was much higher at P2Center than either P2Lateral or P2Medial, independent of ventricular anchor location. Also, forces on both P2Lateral and P2Medial were not statistically different. CONCLUSIONS: Artificial neochordae treatment for all anchoring locations was effective in correcting induced mitral regurgitation. The P2 central neochordae had a significantly higher force than both lateral neochords under all conditions.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Animais , Cordas Tendinosas/cirurgia , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Músculos Papilares/cirurgia , Suínos
6.
J Thorac Cardiovasc Surg ; 164(3): e105-e117, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-33342573

RESUMO

OBJECTIVE: With the recent expanded indication for transcatheter aortic valve replacement to low-risk surgical patients, thrombus formation in the neosinus is of particular interest due to concerns of reduced leaflet motion and long-term transcatheter heart valve durability. Although flow stasis likely plays a role, a direct connection between neosinus flow stasis and thrombus severity is yet to be established. METHODS: Patients (n = 23) were selected to minimize potential confounding factors related to thrombus formation. Patient-specific 3-dimensional reconstructed in vitro models were created to replicate in vivo anatomy and valve deployment using the patient-specific cardiac output and idealized coronary flows. Dye was injected into each neosinus to quantify washout time as a measure of flow stasis. RESULTS: Flow stasis (washout time) showed a significant, positive correlation with thrombus volume in the neosinus (rho = 0.621, P < .0001). Neither thrombus volume nor washout time was significantly different in the left, right, and noncoronary neosinuses (P ≥ .54). CONCLUSIONS: This is the first patient-specific study correlating flow stasis with thrombus volume in the neosinus post-transcatheter aortic valve replacement across multiple valve types and sizes. Neosinus-specific factors create hemodynamic and thrombotic variability within individual patients. Measurement of neosinus flow stasis may guide strategies to improve outcomes in transcatheter aortic valve replacement.


Assuntos
Doenças da Aorta , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Doenças da Aorta/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos
8.
Semin Thorac Cardiovasc Surg ; 33(3): 816-823, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33662555

RESUMO

This hemodynamic feasibility study examined total cavopulmonary connection (TCPC) designs connecting the extracardiac conduit to the anterior surface of pulmonary arteries (PAs) or superior vena cava (SVC) rather than to the inferior PA surface (traditional TCPC). The study involved twenty-five consecutive Fontan patients meeting inclusion criteria from a single institution. A virtual surgical platform mimicked the completed traditional TCPC and generated three anterior anastomosis designs: Anterior-PA, Middle-SVC, and SVC-Inn (Inn: innominate vein). Hemodynamic performance of anterior anastomosis designs was compared with the traditional TCPC regarding indexed power loss (iPL) and hepatic flow distribution (HFD). Compared to the traditional TCPC, the Anterior-PA design produces a similar iPL. The Middle-SVC design is also similar, though the iPL difference is positively correlated with the anastomosing height. The SVC-Inn design had significantly more iPL. The three anterior anastomosis designs did not have a significant difference in HFD (from traditional TCPC). Pulmonary flow distribution (PFD) has a stronger correlation with HFD from the anterior anastomosis designs than the traditional TCPC. This hemodynamic feasibility study examined anterior anastomosis, extracardiac TCPC designs that may offer surgeons clinical dexterity. The Anterior-PA design may be equivalent to the traditional TCPC. Fontan extracardiac conduit anastomosis just superior to the PAs (Middle-SVC) also preserves hemodynamic performance and avoids direct PA anastomosis. These designs could simplify surgical Fontan completion, and may particularly benefit patients requiring surgical dissection, having atypical PA orientation, or after PA stent angioplasty.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/cirurgia , Hemodinâmica , Humanos , Pulmão , Artéria Pulmonar/cirurgia , Veia Cava Superior/cirurgia
9.
J Thorac Cardiovasc Surg ; 161(2): 581-590.e6, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-31879167

RESUMO

BACKGROUND: This study examined whether the presence of a sinus of Valsalva equivalent in the KONECT RESILIA aortic valved conduit (Edwards Lifesciences, Irvine, Calif) improves valve hemodynamics, kinematics, and performance. METHODS: A 28-mm KONECT RESILIA aortic valved conduit was used to create an in vitro flow test model, and the same aortic valved conduit model without a sinus section was used as a control. Particle image velocimetry and hydrodynamic characterization experiments were conducted in the vicinity of the valves in a validated left-heart simulator at 3 cardiac output levels. In addition, leaflet kinematics of the valves were determined through en face high-speed imaging. RESULTS: The KONECT RESILIA aortic valved conduit model exhibited lower mean and peak transvalvular pressure gradients than the control model at all 3 cardiac outputs. In addition, its leaflets opened more fully than did those of the valved conduit without the sinuses, yielding greater effective and geometric orifice areas. It was found that the presence of the sinuses not only facilitated the development of larger and more stable vortices at the initial stages of the cardiac cycle but also helped to maintain these vortices during the late stages of the cardiac cycle, leading to smoother valve closure. CONCLUSIONS: The KONECT RESILIA aortic valved conduit reproduces the bulged section of the aortic root corresponding to the sinuses of Valsalva. With this Valsalva-type conduit, larger orifice areas were observed, improving valve hemodynamics that may enhance performance.


Assuntos
Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Aorta/anatomia & histologia , Aorta/fisiologia , Aorta/cirurgia , Valva Aórtica/anatomia & histologia , Valva Aórtica/fisiologia , Fenômenos Biomecânicos , Velocidade do Fluxo Sanguíneo , Prótese Vascular/normas , Próteses Valvulares Cardíacas/normas , Hemodinâmica , Humanos , Técnicas In Vitro , Seio Aórtico/anatomia & histologia , Seio Aórtico/fisiologia
10.
J Thorac Cardiovasc Surg ; 161(2): 545-558, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33070936

RESUMO

Comprehensive information on the characteristics of surgical heart valves (SHVs) is essential for optimal valve selection. Such information is also important in assessing SHV function after valve replacement. Despite the existing regulatory framework for SHV sizing and labelling, this information is challenging to obtain in a uniform manner for various SHVs. To ensure that clinicians are adequately informed, the European Association for Cardio-Thoracic Surgery (EACTS), The Society of Thoracic Surgeons (STS) and American Association for Thoracic Surgery (AATS) set up a Task Force comprised of cardiac surgeons, cardiologists, engineers, regulatory bodies, representatives of the International Organization for Standardization and major valve manufacturers. Previously, the EACTS-STS-AATS Valve Labelling Task Force identified the most important problems around SHV sizing and labelling. This Expert Consensus Document formulates recommendations for providing SHV physical dimensions, intended implant position and hemodynamic performance in a transparent, uniform manner. Furthermore, the Task Force advocates for the introduction and use of a standardized chart to assess the probability of prosthesis-patient mismatch and calls valve manufacturers to provide essential information required for SHV choice on standardized Valve Charts, uniformly for all SHV models.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/normas , Próteses Valvulares Cardíacas/normas , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Bioprótese/normas , Doenças das Valvas Cardíacas/patologia , Valvas Cardíacas/patologia , Valvas Cardíacas/cirurgia , Hemodinâmica/fisiologia , Humanos
11.
Ann Thorac Surg ; 111(1): 314-326, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33036738

RESUMO

Comprehensive information on the characteristics of surgical heart valves (SHVs) is essential for optimal valve selection. Such information is also important in assessing SHV function after valve replacement. Despite the existing regulatory framework for SHV sizing and labelling, this information is challenging to obtain in a uniform manner for various SHVs. To ensure that clinicians are adequately informed, the European Association for Cardio-Thoracic Surgery (EACTS), The Society of Thoracic Surgeons (STS) and American Association for Thoracic Surgery (AATS) set up a Task Force comprised of cardiac surgeons, cardiologists, engineers, regulatory bodies, representatives of the International Organization for Standardization and major valve manufacturers. Previously, the EACTS-STS-AATS Valve Labelling Task Force identified the most important problems around SHV sizing and labelling. This Expert Consensus Document formulates recommendations for providing SHV physical dimensions, intended implant position and hemodynamic performance in a transparent, uniform manner. Furthermore, the Task Force advocates for the introduction and use of a standardized chart to assess the probability of prosthesis-patient mismatch and calls valve manufacturers to provide essential information required for SHV choice on standardized Valve Charts, uniformly for all SHV models.


Assuntos
Implante de Prótese de Valva Cardíaca/normas , Próteses Valvulares Cardíacas/normas , Desenho de Prótese/normas , Árvores de Decisões , Humanos
12.
Eur J Cardiothorac Surg ; 59(1): 54-64, 2021 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-33021620

RESUMO

Comprehensive information on the characteristics of surgical heart valves (SHVs) is essential for optimal valve selection. Such information is also important in assessing SHV function after valve replacement. Despite the existing regulatory framework for SHV sizing and labelling, this information is challenging to obtain in a uniform manner for various SHVs. To ensure that clinicians are adequately informed, the European Association for Cardio-Thoracic Surgery (EACTS), The Society of Thoracic Surgeons (STS) and American Association for Thoracic Surgery (AATS) set up a Task Force comprised of cardiac surgeons, cardiologists, engineers, regulatory bodies, representatives of the International Organization for Standardization and major valve manufacturers. Previously, the EACTS-STS-AATS Valve Labelling Task Force identified the most important problems around SHV sizing and labelling. This Expert Consensus Document formulates recommendations for providing SHV physical dimensions, intended implant position and haemodynamic performance in a transparent, uniform manner. Furthermore, the Task Force advocates for the introduction and use of a standardized chart to assess the probability of prosthesis-patient mismatch and calls valve manufacturers to provide essential information required for SHV choice on standardized Valve Charts, uniformly for all SHV models.


Assuntos
Próteses Valvulares Cardíacas , Cirurgiões , Cirurgia Torácica , Consenso , Valvas Cardíacas , Humanos , Próteses e Implantes , Estados Unidos
13.
Pediatr Cardiol ; 41(5): 1021-1030, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32377893

RESUMO

Apicocaval juxtaposition (ACJ) is a rare form of viscerocardiac malpositions in association with single-ventricle congenital heart defects. The Fontan surgery is the common palliation, and possible surgical options include ipsilateral, contralateral, and intra-atrial conduits. Concerns include lower hemodynamic performances or risks of conduit compression by the cardiac mass. This study investigates the hemodynamics and clinical outcomes of ACJ patients and potential surgical improvements. Ten consecutive ACJ patients were included, along with a reference cohort of ten non-ACJ patients. Magnetic resonance images were acquired at 6 ± 0.6 year follow-up for anatomical analysis and hemodynamic assessments using computational fluid dynamics. Metrics of interest are deformation index (DI), indexed power loss (iPL), and hepatic flow distribution (HFDoff). A "virtual" surgery was performed to explore potential hemodynamic improvements using a straightened conduit. DI for ACJ patients fell within the DI range of non-ACJ patients. Contralateral conduits had insignificantly higher iPL (0.070 [0.032,0.137]) than ipsilateral conduits (0.041 [0.013,0.095]) and non-ACJ conduits (0.034 [0.011,0.061]). HFDoff was similar for the ipsilateral (21 [12,35]), contralateral (26 [7,41]), and non-ACJ Fontan conduits (17 [0,48]). Virtual surgery demonstrated that a straightened conduit reduced HFDoff and iPL for the contralateral and ipsilateral conduits, potentially leading to improved clinical outcomes. In this limited sample, the hemodynamic performance of ACJ patients was not significantly different from their non-ACJ counterparts. The use of a straightened conduit option could potentially improve patient outcomes. Additionally, the fear of significant compression of conduits for ACJ patients was unsupported.


Assuntos
Técnica de Fontan/métodos , Cardiopatias Congênitas/cirurgia , Adolescente , Estudos de Casos e Controles , Criança , Feminino , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/anormalidades , Ventrículos do Coração/cirurgia , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Masculino , Artéria Pulmonar/patologia , Artéria Pulmonar/cirurgia
14.
Ann Biomed Eng ; 48(8): 2204-2217, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32372365

RESUMO

The Fontan procedure is a common palliative surgery for congenital single ventricle patients. In silico and in vitro patient-specific modeling approaches are widely utilized to investigate potential improvements of Fontan hemodynamics that are related to long-term complications. However, there is a lack of consensus regarding the use of non-Newtonian rheology, warranting a systematic investigation. This study conducted in silico patient-specific modeling for twelve Fontan patients, using a Newtonian and a non-Newtonian model for each patient. Differences were quantified by examining clinically relevant metrics: indexed power loss (iPL), indexed viscous dissipation rate (iVDR), hepatic flow distribution (HFD), and regions of low wall shear stress (AWSS). Four sets of "non-Newtonian importance factors" were calculated to explore their effectiveness in identifying the non-Newtonian effect. No statistical differences were observed in iPL, iVDR, and HFD between the two models at the population-level, but large inter-patient variations exist. Significant differences were detected regarding AWSS, and its correlations with non-Newtonian importance factors were discussed. Additionally, simulations using the non-Newtonian model were computationally faster than those using the Newtonian model. These findings distinguish good importance factors for identifying non-Newtonian rheology and encourage the use of a non-Newtonian model to assess Fontan hemodynamics.


Assuntos
Técnica de Fontan , Hidrodinâmica , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Adolescente , Criança , Feminino , Humanos , Masculino , Estudos Retrospectivos
15.
Gen Thorac Cardiovasc Surg ; 68(1): 9-17, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31250203

RESUMO

OBJECTIVE: Rapid deployment surgical aortic valve replacement has emerged as an alternative to the contemporary sutured valve technique. A difference in transvalvular pressure has been observed clinically between RD-SAVR and contemporary SAVR. A mechanistic inquiry into the impact of the rapid deployment valve inflow frame design on the left ventricular outflow tract and valve hemodynamics is needed. METHODS: A 23 mm EDWARDS INTUITY Elite rapid deployment valve and a control contemporary, sutured valve, a 23 mm Magna Ease valve, were implanted in an explanted human heart by an experienced cardiac surgeon. Per convention, the rapid deployment valve was implanted with three non-pledgeted, simple guiding sutures, while fifteen pledgeted, mattress sutures were used to implant the contemporary surgical valve. In vitro flow models were created from micro-computed tomography scans of the implanted valves and surrounding cardiac anatomy. Particle image velocimetry and hydrodynamic characterization experiments were conducted in the vicinity of the valves in a validated pulsatile flow loop system. RESULTS: The rapid deployment and control valves were found to have mean transvalvular pressure gradients of 7.92 ± 0.37 and 10.13 ± 0.48 mmHg, respectively. The inflow frame of the rapid deployment valve formed a larger, more circular, left ventricular outflow tract compared to the control valve. Furthermore, it was found that the presence of the control valve's sub-annular pledgets compromised its velocity distribution and consequently its pressure gradient. CONCLUSIONS: The rapid deployment valve's intra-annular inflow frame provides for a larger, left ventricular outflow tract, thus reducing the transvalvular pressure gradient and improving overall hemodynamic performance.


Assuntos
Próteses Valvulares Cardíacas , Hemodinâmica/fisiologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Microtomografia por Raio-X
16.
J Thorac Cardiovasc Surg ; 159(5): 1766-1774.e2, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31272749

RESUMO

OBJECTIVE: The study objective was to develop a novel annuloplasty ring with regional flexibility and assess its suture force dynamics in healthy ovine subjects compared with fully rigid or fully flexible rings. METHODS: Materially heterogeneous rings were created with rigid anterior and posterior, and flexible commissural segments. These rings were created to match the geometry of the Profile 3D ring (Medtronic, Minneapolis, Minn). Each ring was instrumented with 10 force transducers to measure cyclic suture forces (FC) and undersized annuloplasty was performed in 6 healthy ovine subjects. Each FC was recorded and examined for cardiac cycles reaching a maximum left ventricular pressure of 100, 125, and 150 mm Hg. FC was compared with previously reported values from fully rigid Profile 3D and fully flexible prototype rings. RESULTS: Relative to the fully rigid ring, the heterogeneous ring exhibited 48% reduction in FC at its commissural (rigid vs heterogeneous: 1.80 ± 0.94 N vs 0.95 ± 0.52 N; P < .001) and 32% reduction in posterior (1.90 ± 0.92 N vs 1.29 ± 0.91 N; P < .001) regions, but not in its anterior region (2.45 ± 1.21 N vs 2.23 ± 1.22 N; P = .279). Relative to the fully flexible ring, the heterogeneous ring exhibited no significant differences in FC in any region. CONCLUSIONS: The reduced FC of the heterogeneous ring relative to the fully rigid ring suggests a promising approach to reduce suture loading while preserving the annular remodeling capability of fully rigid rings. Future studies in diseased subjects are necessary to explore repair effectiveness of this ring.


Assuntos
Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/instrumentação , Valva Mitral/cirurgia , Desenho de Prótese , Animais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Teste de Materiais , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Anuloplastia da Valva Mitral/efeitos adversos , Modelos Animais , Maleabilidade , Carneiro Doméstico , Estresse Mecânico
17.
J Thorac Cardiovasc Surg ; 159(2): 652-661, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31399233

RESUMO

OBJECTIVE: The use of Y-grafts for Fontan completion is hypothesized to offer more balanced hepatic flow distribution (HFD) and decreased energy losses. The purpose of this study was to evaluate the hemodynamic performance of Y-grafts over time using serial cardiac magnetic resonance data and to compare their performance with extracardiac Fontan connections. METHODS: Ten Fontan patients with commercially available Y-graft connections and serial postoperative cardiac magnetic resonance data were included in this study. Patient-specific computational fluid dynamics simulations were used to estimate HFD and energy losses. Y-graft performance was compared with 3 extracardiac conduit Fontan groups (n = 10 for each) whose follow-up times straddle the Y-graft time points. RESULTS: Y-graft HFD became significantly more balanced over time (deviation from 50% decreased from 18% ± 14% to 8% ± 8%; P = .015). Total cavopulmonary connection resistance did not significantly change. Y-grafts at 3-year follow-up showed more balanced HFD than the extracardiac conduit groups at both the earlier and later follow-up times. Total cavopulmonary connection resistance was not significantly different between any Y-graft or extracardiac conduit group. CONCLUSIONS: Y-grafts showed significantly more balanced HFD over a 3-year follow-up without an increase in total cavopulmonary connection resistance, and therefore may be a valuable option for Fontan completion. Additional follow-up data at longer follow-up times are still needed to thoroughly characterize the potential advantages of Y-graft use.


Assuntos
Prótese Vascular , Técnica de Fontan , Hemodinâmica/fisiologia , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Técnica de Fontan/efeitos adversos , Técnica de Fontan/instrumentação , Técnica de Fontan/métodos , Técnica de Fontan/estatística & dados numéricos , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Humanos , Masculino , Desenho de Prótese , Artéria Pulmonar/fisiologia , Artéria Pulmonar/cirurgia , Adulto Jovem
18.
Ann Thorac Surg ; 109(2): 574-582, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31518584

RESUMO

BACKGROUND: Little is known of baseline anatomic, hemodynamic, and fluid dynamic cardiac magnetic resonance data in single-ventricle patients immediately after Fontan. A comparison from that time point to the teen years can demonstrate clinical course, potentially predict future events, and may shed some light regarding how to optimize outcome. This cross-sectional study is meant to characterize these variables from just after Fontan to the teenage years. METHODS: The anatomy, flows, and computational fluid dynamic modeling of 22 patients 3 to 9 months after Fontan (age 3 ± 1.1 years) and 25 teens (age 16 ± 1.8 years) were compared. Significance was defined as P less than .05. RESULTS: The percentage of Fontan pathway stenosis was greater with cardiac index and fenestration flow while caval return was lower in teens than in younger patients (for Fontan pathway stenosis, 43% vs 21%, P = .009); however, hepatic flow distribution was more evenly distributed in older patients. Pulmonary artery size kept up with somatic growth. In the teen group, indexed power loss (R = .39), percentage of Fontan pathway stenosis (R = .62), and particle resident time (R = .42) deteriorated as time from Fontan increased (P < .04 for all). CONCLUSIONS: There are mostly aspects of deterioration with a few bright spots of stability in anatomy, blood flow, and fluid dynamic variables in Fontan patients from the postoperative period to the teenage years. Most notably, Fontan pathway stenosis increases with decreasing flows while pulmonary artery size and hepatic flow distribution remain stable or improved. These data may be aid in designing improved Fontan reconstruction to optimize clinical outcome and to understand future complications.


Assuntos
Técnica de Fontan , Imageamento por Ressonância Magnética/métodos , Modelos Teóricos , Coração Univentricular/cirurgia , Adolescente , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Lactente , Masculino , Período Pós-Operatório , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
19.
J Cardiovasc Transl Res ; 13(4): 640-647, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31732919

RESUMO

Fontan surgical planning ranks proposed surgical options according to their hemodynamics assessed by computational fluid dynamic (CFD) modeling. CFD commonly utilizes blood flow acquired under breath-holding (BH) conditions. Ignoring the free-breathing (FB) effect on blood flow waveforms may impact the ranking of surgical options. This study investigates such a potential impact by including ten Fontan patients who had blood flow acquisitions under both BH and FB conditions. A virtual surgery platform was used to generate two surgical options for each patient: (1) a traditional Fontan conduit and (2) a Y-graft. These options were ranked based on clinically relevant hemodynamic metrics: power loss (PL) and hepatic flow distribution (HFD). No difference was found in the ranking of options between using FB and BH flow acquisitions. The findings indicated that decision-making is not affected by the types of flow acquisition for Fontan surgical planning.


Assuntos
Tomada de Decisão Clínica , Diagnóstico por Computador , Técnica de Fontan , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Imageamento por Ressonância Magnética , Modelagem Computacional Específica para o Paciente , Adolescente , Feminino , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/fisiopatologia , Hemodinâmica , Humanos , Masculino , Seleção de Pacientes , Valor Preditivo dos Testes , Estudo de Prova de Conceito , Reoperação , Mecânica Respiratória , Estudos Retrospectivos , Adulto Jovem
20.
Ann Thorac Surg ; 109(6): 1904-1911, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31734244

RESUMO

BACKGROUND: Liver fibrosis is a serious complication of single ventricle Fontan survivors. Its causes are of great interest, and potential solutions to halt or delay progression are needed. The purpose of this study is to investigate if prior hemodynamics and anatomy can predict liver fibrosis severity in these patients. METHODS: Twenty-one Fontan patients with cardiac magnetic resonance (CMR) data obtained greater than 1 year before liver biopsy data were included. Computational fluid dynamic simulations were performed to quantify total cavopulmonary connection (TCPC) flow dynamics using patient-specific anatomies and blood flow waveforms reconstructed from CMR data. Collagen deposition (a measure of liver fibrosis) was quantified by digital image analysis of Sirius red-stained slides. Statistical analyses were performed to investigate potential relationships between Fontan hemodynamics and liver fibrosis. RESULTS: With an average time of 6.7 ± 2.9 years (range, 2-11 years) between CMR and biopsy, TCPC resistance and left pulmonary artery stenosis showed significant, positive correlations with magnitude of liver fibrosis (r = 0.54, P = .026; and r = 0.55, P = .028, respectively). The change in inferior vena cava flow rate over time also showed a significant positive correlation with magnitude of liver fibrosis (r = 0.91, P = .001). CONCLUSIONS: TCPC resistance, left pulmonary artery stenosis, and increased inferior vena cava flow are positively associated with liver fibrosis after Fontan operation and hold promise as important predictors of hepatic decline. These findings encourage preprocedural planning and interventional strategies to improve TCPC performance and reduce vessel stenosis. Further investigation is warranted to design the ideal Fontan circulation and optimize flow dynamics to reduce the risk of liver fibrosis.


Assuntos
Técnica de Fontan/efeitos adversos , Previsões , Cardiopatias Congênitas/diagnóstico , Cirrose Hepática/diagnóstico , Fígado/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Complicações Pós-Operatórias , Adolescente , Biópsia , Criança , Pré-Escolar , Feminino , Seguimentos , Cardiopatias Congênitas/cirurgia , Humanos , Cirrose Hepática/etiologia , Masculino , Período Pré-Operatório , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS