Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Br J Anaesth ; 132(6): 1211-1218, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38677950

RESUMO

BACKGROUND: Low-dose tranexamic acid (TXA) has been recently recommended for cardiopulmonary bypass (CPB) to reduce associated complications. Although point-of-care laboratory tests for TXA concentrations are unavailable, a novel TPA-test on the ClotPro® system can measure TXA-induced inhibition of fibrinolysis. We evaluated the performance of the TPA-test in vitro and in patients undergoing surgery requiring CPB. METHODS: Blood samples were obtained from six volunteers for in vitro evaluation of tissue plasminogen activator (tPA)-triggered fibrinolysis and the effects of TXA. This was followed by an observational study in 20 cardiac surgery patients to assess clinical effects of TXA on the TPA-test. RESULTS: Hyperfibrinolysis induced by tPA was inhibited by TXA ≥2 mg L-1 in a concentration-dependent manner, and was completely inhibited at TXA ≥10 mg L-1. In patients undergoing CPB, antifibrinolytic effect was detectable on TPA-test parameters after a 0.1 g bolus of TXA at the end of CPB, and complete inhibition of fibrinolysis was obtained with TXA ≥0.5 g. The antifibrinolytic effects of 1 g TXA on TPA-test parameters were gradually attenuated over 18 h after surgery. However, the fibrinolytic inhibition continued in four patients with estimated glomerular filtration rate (eGFR) ≤30 ml min-1 1.73 m-2. The eGFR had strong correlations with TPA-test parameters at 18 h after surgery (r=0.86-0.92; P<0.0001). CONCLUSIONS: The TPA-test is sensitive to low concentrations of TXA and serves as a practical monitoring tool for postoperative fibrinolytic activity in cardiac surgery patients. This test might be particularly useful in patients with severe renal impairment.


Assuntos
Antifibrinolíticos , Procedimentos Cirúrgicos Cardíacos , Fibrinólise , Testes Imediatos , Ácido Tranexâmico , Humanos , Ácido Tranexâmico/farmacologia , Ácido Tranexâmico/uso terapêutico , Antifibrinolíticos/uso terapêutico , Antifibrinolíticos/farmacologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Fibrinólise/efeitos dos fármacos , Estudo de Prova de Conceito , Ponte Cardiopulmonar , Ativador de Plasminogênio Tecidual/farmacologia , Adulto , Idoso de 80 Anos ou mais , Relação Dose-Resposta a Droga
2.
J Anesth ; 38(1): 98-104, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38150014

RESUMO

PURPOSE: The reduced effects of allogeneic transfusion with acute normovolemic hemodilution (ANH) have been reported. Harvesting a large volume of blood may maximize the effect in patients with low body weight, and the prevention of hypotension is important. Remimazolam is an anesthetic with few circulatory responses. Our aim was to evaluate whether high-volume ANH reduces the need for transfusion in cardiac patients under remimazolam anesthesia. METHODS: In this retrospective single-center study, we enrolled cardiopulmonary bypass (CPB) patients who received remimazolam anesthesia. Changes in hemodynamic parameters were assessed. The numbers of blood transfusions and chest tube outputs were also evaluated. RESULTS: In a total of 51 patients, ANH was performed in 27 patients with a mean body mass index of 23.2 (ANH volume: 740 ± 222 mL). No significant differences were observed in mean blood pressure during blood collection. The intraoperative amount of red blood cell (RBC) transfusion was significantly lower in the ANH group than in the control group (431 ± 678 and 1260 ± 572 mL, p < 0.001). The avoidance rates of RBC were 66.7 and 4.2%, respectively. The multivariate analysis result revealed that ANH correlated with RBC, with an odds ratio of 0.067 (95% confidence interval 0.005-0.84, p < 0.05). The postoperative bleeding at 24 h was significantly lower in the ANH group (455 ± 228 and 797 ± 535 mL, p < 0.01). CONCLUSION: In patients undergoing CPB, ANH reduced intraoperative transfusion amount and postoperative bleeding. Hemodynamic changes during blood collection were minimal under remimazolam anesthesia and high-volume ANH was feasible.


Assuntos
Anestesia , Benzodiazepinas , Procedimentos Cirúrgicos Cardíacos , Humanos , Hemodiluição , Estudos Retrospectivos
3.
A A Pract ; 17(5): e01676, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37146220

RESUMO

A 61-year-old woman with chronic renal dysfunction was scheduled to undergo aortic valve replacement. After a bolus of 1 g tranexamic acid (TXA), the TPA (tissue-plasminogen activator)-test result with the ClotPro system demonstrated extensive inhibition of fibrinolysis. Plasma TXA level decreased from 71 to 25 µg/dL at 6 hours postoperatively; however, no further decrease was observed. Although TXA levels dropped to 6.9 µg/dL after hemodialysis on postoperative day (PoD) 1, fibrinolytic shutdown on the TPA-test remained unchanged until PoD 2. In dialysis patients, low-dose TXA <1 g may be considered for reducing seizure and thromboembolic complications after cardiac surgery.


Assuntos
Antifibrinolíticos , Procedimentos Cirúrgicos Cardíacos , Ácido Tranexâmico , Feminino , Humanos , Pessoa de Meia-Idade , Ácido Tranexâmico/uso terapêutico , Antifibrinolíticos/uso terapêutico , Fibrinólise
4.
Sci Rep ; 12(1): 17269, 2022 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-36241854

RESUMO

Viscoelastic coagulation tests have been increasingly used for hemostasis management in cardiac surgery. The ClotPro system is a novel viscoelastic device based on principles of rotational thromboelastometry. We aimed to compare ClotPro with ROTEM and plasma coagulation assays in cardiopulmonary bypass (CPB) patients. Blood samples were collected from 25 CPB patients at (1) baseline, (2) start of CPB, (3) end of CPB, and (4) end of surgery. The EX-test, IN-test, HI-test, FIB-test parameters on ClotPro were compared with corresponding ROTEM assay (EXTEM, INTEM, HEPTEM, and FIBTEM). Standard plasma coagulation assays and endogenous thrombin generation (TG) were simultaneously evaluated. Pearson correlation analyses showed moderate correlations between clotting times (CTs) (r = 0.63-0.67; p < 0.001, respectively), and strong correlations with maximal clot firmness (MCF) (r = 0.93-0.98; p < 0.001, respectively) between ClotPro and ROTEM. EX-test and IN-test MCF parameters were interchangeable with acceptable percentage errors (EX-test MCF: 7.3%, IN-test MCF: 8.3%), but FIB-test MCF (27.0%) and CT results were not (EX-test CT: 44.7%, IN-test CT: 31.4%). The correlations of PT/INR or peak TG with EX-test CTs were higher than with EXTEM CTs (PT/INR: r = 0.80 and 0.41, peak TG: 0.43 and 0.18, respectively). FIB-test MCF has strong correlation with plasma fibrinogen and factor XIII level (r = 0.84 and 0.66, respectively). ROC analyses showed that ClotPro was capable of emulating well-established ROTEM thresholds (area under curves: 0.83-1.00). ClotPro demonstrated strong correlations in MCF parameters of ROTEM in CPB patients. It may be reasonable to modify ROTEM-based transfusion algorithm pertaining to MCF parameters to establish cut-off values for ClotPro device.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Tromboelastografia , Coagulação Sanguínea , Testes de Coagulação Sanguínea/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Fator XIII , Fibrinogênio , Humanos , Tromboelastografia/métodos , Trombina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA