Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38914371

RESUMO

OBJECTIVES: In remodeling valve-sparing root replacement with external annuloplasty, we compare long-term outcomes of a calibrated expansible extra-aortic ring with a homemade Dacron ring. METHODS: All patients (2003-2020) operated for root aneurysm with/without aortic insufficiency (AI) were included. The standardized CAVIAAR (conservation aortique valvulaire dans les insuffisances aortiques et anévrysmes de la racine-Valve sparing in aortic insufficiencies and root aneurysms) technique was root remodeling and external annuloplasty ring with the EXTRA-AORTIC Ring or homemade Dacron ring. RESULTS: Among 486 patients (age 52.3 ± 14.0 years) operated for root aneurysm, 375 (repair rate: 77.1%) underwent root remodeling with annuloplasty (extra-aortic ring, n = 289, vs Dacron ring, n = 86). At 10 years (median follow-up, 4.08 years' interquartile range, 1.95-7.61), unmatched and matched analysis showed that patients with extra-aortic ring had greater survival, similar to the general population (93.3% vs 79.9%, P = .097), lower reoperation incidence (2.0% vs 9.7%, P = .0098), and lower AI grade >2 recurrence (1.9% vs 11.2%, P = .0042), compared with patients with a Dacron ring. Mixed-effect model showed that with extra-aortic ring annuloplasty, annular dilation over time (P = .0033) was prevented and, compared with the homemade Dacron ring, root expansibility was better preserved (3.22% vs 2.12%, P = .002) and mean transvalvular gradient was lower (6.58 mm Hg vs 7.94 mm Hg, P = .001). Tricuspid and bicuspid valves with extra-aortic ring had similar reoperation (4.3% vs 0.85%, P = .65) and AI grade >2 incidence (2.7% vs 1.2%, P = .61), expansibility (P = .29), and diameter (P = .47), whereas mean transvalvular gradient was lower for tricuspid valves (5.58 mm Hg vs 7.60 mm Hg, P = .004). CONCLUSIONS: Valve-sparing root remodeling with calibrated expansible extra-aortic ring annuloplasty improves the outcomes of reoperation and recurrent AI compared with a homemade Dacron ring. It prevents dilation and maintains physiological root dynamics for durable valve repair.

3.
Artigo em Inglês | MEDLINE | ID: mdl-36535821

RESUMO

OBJECTIVE: We investigated long-term outcomes of bicuspid aortic valve (BAV) repair, with external annuloplasty, according to aorta phenotype. METHODS: Between 2003 and 2020, all patients with BAV operated on for aortic insufficiency (AI) and/or aneurysm were included. Repairs included isolated AI repair with subvalvular with or without sinotubular junction (STJ) (single or double) annuloplasty, supracoronary aorta replacement (with or without hemiroot remodeling), and root remodeling with external subvalvular ring annuloplasty. RESULTS: Among 343 patients operated, reparability rate was 81.3% (n = 279; age 46 ± 13.3 years). At 10 years (median follow-up: 3.42 years; interquartile range, 1.1, 5.8), survival was 93.9% (n = 8 deaths, similar to general population), cumulative incidence of reoperation was 6.2% (n = 10), AI grade >2 was 5.8% (n = 9), and grade >1 was 23.0% (n = 30). BAV repair stabilizing both the annulus and STJ with annuloplasty, compared with nonstabilized STJ repair (single annuloplasty), had lower incidence of reoperation (2.6% vs 22.5%, P = .0018) and AI grade >2 (1.2% vs 23.6%, P < .001) at 9 years. Initial commissural angle <160° was not a risk factor for reoperation, compared with angle ≥160° if symmetrical repair was achieved (2.7% and 4.1%, respectively, at 6 years, P = .85). Multivariable model showed that absence of STJ stabilization (odds ratio, 6.7; 95% confidence interval, 2.1-20, P = .001) increased recurrent AI, but not initial commissural angle <160° (odds ratio, 1.01; 95% confidence interval, 0.39-2.63, P = .98). Commissures adjusted symmetrically led to lower transvalvular gradient, compared with nonsymmetrical repair (8.7 mm Hg vs 10.2 mm Hg, P = .029). CONCLUSIONS: BAV repair, tailored to aorta phenotype, is associated with excellent durable outcomes if both annulus and STJ are reduced and stabilized with external ring annuloplasty. Commissural angle <160° is not associated with reoperation if symmetrical repair is achieved.

4.
Eur J Cardiothorac Surg ; 62(1)2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35438171

RESUMO

OBJECTIVES: We investigated whether aortic valve fenestrations (respected or fixed) represent a factor associated with recurrent aortic insufficiency or reoperation after repair. METHODS: Between 2003 and 2019, patients who underwent aortic valve repair were included. Aortic insufficiency phenotypes were root aneurysm (repair: root remodelling + annuloplasty), ascending aorta aneurysm (repair: tubular aortic replacement + annuloplasty) and isolated regurgitation (repair: single/double annuloplasty). Fenestrations were either respected or fixed according to their features. RESULTS: A total of 618 patients (out of 798 operated on; 77.4%) had their valve repaired, with 167 cases of fenestrations (128 were respected, 39 fixed-32 with a patch, 6 with running suture and 1 with both). After conducting propensity score matching between no-fenestration (n = 167) and fenestration groups (n = 167), respectively, we noted the following: survival [90.3% (n = 7 deaths) vs 95.8% (n = 4)], cumulative incidence of reoperation [6.7% (n = 7) vs 5.2% (n = 4)], aortic insufficiency grade ≥ 3 [6.4% (n = 6) vs 4.4% (n = 4)] and grade ≥ 2 [28.9% (n = 28) vs 37.1% (n = 35)] were similar at 9 years [P = 0.94; median follow-up: 2.2, interquartile range: (0.8, 5.8)], whether fenestration was respected (P = 0.55) or fixed (P = 0.6, at 6 years). Standardization of the surgical approach (consisting of double annuloplasty in isolated regurgitation phenotype and expansible subvalvular annuloplasty with effective height assessment with remodelling repair for root aneurysm phenotype) reduced the risk of reoperation (era before standardization: hazard ratio: 5.4, 95% confidence interval: 1.9-15.7, P = 0.002). CONCLUSIONS: Fenestration, respected or fixed, is not a factor associated with reoperation or recurrence of significant aortic insufficiency after valve repair if the surgical approach is standardized.


Assuntos
Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Humanos , Reoperação , Respeito , Resultado do Tratamento
6.
PLoS Comput Biol ; 17(5): e1008881, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33970900

RESUMO

In this work, we describe the CRIMSON (CardiovasculaR Integrated Modelling and SimulatiON) software environment. CRIMSON provides a powerful, customizable and user-friendly system for performing three-dimensional and reduced-order computational haemodynamics studies via a pipeline which involves: 1) segmenting vascular structures from medical images; 2) constructing analytic arterial and venous geometric models; 3) performing finite element mesh generation; 4) designing, and 5) applying boundary conditions; 6) running incompressible Navier-Stokes simulations of blood flow with fluid-structure interaction capabilities; and 7) post-processing and visualizing the results, including velocity, pressure and wall shear stress fields. A key aim of CRIMSON is to create a software environment that makes powerful computational haemodynamics tools accessible to a wide audience, including clinicians and students, both within our research laboratories and throughout the community. The overall philosophy is to leverage best-in-class open source standards for medical image processing, parallel flow computation, geometric solid modelling, data assimilation, and mesh generation. It is actively used by researchers in Europe, North and South America, Asia, and Australia. It has been applied to numerous clinical problems; we illustrate applications of CRIMSON to real-world problems using examples ranging from pre-operative surgical planning to medical device design optimization.


Assuntos
Hemodinâmica/fisiologia , Modelos Cardiovasculares , Software , Síndrome de Alagille/fisiopatologia , Síndrome de Alagille/cirurgia , Vasos Sanguíneos/anatomia & histologia , Vasos Sanguíneos/diagnóstico por imagem , Vasos Sanguíneos/fisiologia , Biologia Computacional , Simulação por Computador , Análise de Elementos Finitos , Fatores de Risco de Doenças Cardíacas , Humanos , Imageamento Tridimensional , Transplante de Fígado/efeitos adversos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Modelos Anatômicos , Modelagem Computacional Específica para o Paciente , Complicações Pós-Operatórias/etiologia , Interface Usuário-Computador
8.
J Cardiovasc Surg (Torino) ; 62(1): 12-18, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33185078

RESUMO

Standardization of aortic valve repair techniques with use of a calibrated annuloplasty have led to improved long-term outcomes in dystrophic aortic insufficiency. It can also improve dissemination of techniques and rates of aortic valve repair. Dystrophic aortic insufficiency can be found in three aortic phenotypes: dilated aortic root, dilated ascending aorta and isolated aortic insufficiency. The aortic annulus is invariably dilated above 25 mm in the vast majority of cases of aortic insufficiency, regardless of whether the aorta is dilated or not. A dilated annulus is a risk factor for late failure of aortic valve repair if not addressed at the time of surgery. We perform a calibrated annuloplasty at both sub- and supra-valvular levels in order to restore the ratio of sinotubular junction and annulus. Current evidence shows aortic valve repair reduces valve-related mortality compared to prosthetic valve replacement, with an improved quality of life.


Assuntos
Aneurisma Aórtico/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Aneurisma Aórtico/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Anuloplastia da Valva Cardíaca/efeitos adversos , Anuloplastia da Valva Cardíaca/instrumentação , Anuloplastia da Valva Cardíaca/mortalidade , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Qualidade de Vida , Recuperação de Função Fisiológica , Fatores de Risco , Resultado do Tratamento
9.
Indian J Thorac Cardiovasc Surg ; 36(Suppl 1): 88-96, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33061189

RESUMO

Dystrophic aortic insufficiency accounts for the majority of Western cases of aortic insufficiency and can be divided into the three phenotypes of isolated aortic insufficiency, dilated aortic root, and dilated ascending aorta. Each of these phenotypes is associated with a dilated annulus and/or sinotubular junction. Recent international guidelines recommend reimplantation or remodeling with aortic annuloplasty for valve-sparing root replacement, as well as consideration of aortic valve repair in cases of aortic insufficiency. A dilated aortic annulus is a major risk factor for failure of aortic valve repair procedures, indicating the need to address the annulus at the time of aortic valve or root repair. Calibrated annuloplasty should be performed at sub- and supravalular levels in order to restore the ratio of the sinotubular junction and annulus and be adapted according to the phenotype of the root and ascending aorta. Standardization of aortic valve repair techniques with use of a calibrated annuloplasty will improve dissemination of techniques and rate of aortic valve repair. Current medical evidence shows that aortic valve repair is safe, produces better quality of life, and reduces valve-related mortality compared to prosthetic valve replacement.

13.
Ann Cardiothorac Surg ; 8(3): 322-330, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31240176

RESUMO

Available evidence shows that aortic valve repair reduces valve-related mortality and improves quality of life compared to prosthetic aortic valve replacement. One of the most important predictors of bicuspid and tricuspid aortic valve repair failure is the absence of treating a dilated aortic annulus greater than 25-28 mm. Competency of the aortic valve depends on multiple factors including the diameter of the annulus, sinotubular junction, valve cusps and commissures. Dystrophic aortic insufficiency (AI) is the commonest cause of AI in the Western world and is characterised by dilatation of the aortic annulus (≥25 mm), sinuses and/or sinotubular junction (≥30 mm). Depending on whether the sinuses of Valsalva and/or tubular ascending aorta are dilated, three phenotypes can be identified: dilated aortic root, dilated ascending aorta and isolated AI. All three phenotypes are associated with a dilated aortic annulus. Aortic annuloplasty reduces the dilated aortic annulus and improves the surface of coaptation, as in the case of mitral valve repair. In treating AI, it is also important to restore the physiological sinotubular junction/annulus ratio, which can be carried out with remodeling root repair + subvalvular annuloplasty (for dilated aortic root), tubular ascending aorta replacement + subvalvular annuloplasty (for dilated ascending aorta) and double sub- and supra-valvular annuloplasty (for isolated AI). Aortic annuloplasty is now considered an essential component of aortic valve repair and valve-sparing root surgery.

14.
Ann Cardiothorac Surg ; 8(3): 351-361, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31240179

RESUMO

BACKGROUND: Systolic aortic root expansion is reported to facilitate valve opening, but the precise dynamics remain unknown. A sonometric study with a high data sampling rate (200 to 800 Hz) was conducted in an acute ovine model to better understand the timing, mechanisms, and shape of aortic valve opening and closure. METHODS: Eighteen piezoelectric crystals were implanted in 8 sheep at each annular base, commissures, sinus of Valsalva, sinotubular junction, nodulus of Arantius, and ascending aorta (AA). Geometric changes were time related to pressures and flows. RESULTS: The aortic root was hemodynamically divided into left ventricular (LV) and aortic compartments situated, respectively, below and above the leaflets. During isovolumetric contraction (IVC), aortic root expansion started in the LV compartment, most likely due to volume redistribution in the LV outflow tract below the leaflets. This expansion initiated leaflet separation prior to ejection (2.1%±0.5% of total opening area). Aortic compartment expansion was delayed toward the end of IVC, likely related to volume redistribution above the leaflets due to accelerating aortic backflow toward the aortic valve and coronary flow reduction due to myocardial contraction. Maximum valve opening during the first third of ejection acquired a truncated cone shape [leaflet free edge area smaller than annular base area (-41.5%±5.5%)]. The distal orifice became clover shaped because the leaflet free edge area is larger than the commissural area by 16.3%±2.0%. CONCLUSIONS: Aortic valve opening is initiated prior to ejection related to delicate balance between LV, aortic root, and coronary dynamics. It is clover shaped at maximum opening in systole. A better understanding of these mechanisms should stimulate more physiological surgical approaches of valve repair and replacement.

15.
Ann Cardiothorac Surg ; 8(3): 401-410, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31240187

RESUMO

The bicuspid aortic valve (BAV) is the most common congenital cardiovascular anomaly and may present with differing phenotypes including almost constant annular dilation. We have developed a standardized approach to BAV repair with a systematic adjunct of aortic annuloplasty according to the three phenotypes of the proximal aorta, which include a dilated aortic root, dilated ascending aorta and normal root and ascending aorta. In our cohort of 191 patients, freedom from AV-related re-intervention was 98% for remodeling with annuloplasty (n=100) and 100% for tubular aortic replacement with annuloplasty (n=31) at 8 years. In an isolated aortic insufficiency (AI) group, freedom from AV-related re-intervention varied from 72.4% with a single subvalvular annuloplasty ring (n=31) compared to 100% at 6 years when a double sub- and supra-valvular (STJ) annuloplasty ring was performed (n=29). Restoration of the annulus: sinotubular junction (STJ) ratio is a key factor to ensure longevity of the bicuspid valve repair and freedom from re-intervention.

18.
Semin Thorac Cardiovasc Surg ; 31(4): 643-649, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31229691

RESUMO

Aortic valve surgery in non-elderly patients represents a very challenging patient population. The younger the patient is at the point of aortic valve intervention, the longer their anticipated life expectancy will be, with longer exposure to valve-related complications and risk for re-operation. Although the latest international guidelines recommend aortic valve repair in patients with aortic valve insufficiency, what we see in the real world is that the vast majority of these aortic valves are replaced. However, current prosthetic valves has now been shown to lead to significant loss of life expectancy for non-elderly patients up to 50% for patients in their 40s undergoing mechanical aortic valve replacement. Bioprostheses carry an even worse long-term survival, with higher rates of re-intervention. The promise of trans-catheter valve-in-valve technology is accentuating the trend of bioprosthetic implantation in younger patients, without yet the appropriate evidence. In contrast, aortic valve repair has shown excellent outcomes in terms of quality of life, freedom from re-operation and freedom from major adverse valve-related events with similar life expectancy to general population as it is also found for the Ross procedure, the only available living valve substitute. We are at a time when the paradigm of aortic valve surgery needs to change for the better. To better serve our patients, we must acquire high quality real-world evidence from multiple centers globally - this is the vision of the AVIATOR registry and our common responsibility.


Assuntos
Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Adulto , Fatores Etários , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Bioprótese , Medicina Baseada em Evidências , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Expectativa de Vida , Pessoa de Meia-Idade , Falha de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
20.
Eur J Cardiothorac Surg ; 55(4): 610-617, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30239633

RESUMO

Both genetic and haemodynamic theories explain the aetiology, progression and optimal management of bicuspid aortic valve aortopathy. In recent years, the haemodynamic theory has been explored with the help of magnetic resonance imaging and computational fluid dynamics. The objective of this review was to summarize the findings of these investigations with focus on the blood flow pattern and associated variables, including flow eccentricity, helicity, flow displacement, cusp opening angle, systolic flow angle, wall shear stress (WSS) and oscillatory shear index. A structured literature review was performed from January 1990 to January 2018 and revealed the following 3 main findings: (i) the bicuspid aortic valve is associated with flow eccentricity and helicity in the ascending aorta compared to healthy and diseased tricuspid aortic valve, (ii) flow displacement is easier to obtain than WSS and has been shown to correlate with valve morphology and type of aortopathy and (iii) the stenotic bicuspid aortic valve is associated with elevated WSS along the greater curvature of the ascending aorta, where aortic dilatation and aortic wall thinning are commonly found. We conclude that new haemodynamic variables should complement ascending aorta diameter as an indicator for disease progression and the type and timing of intervention. WSS describes the force that blood flow exerts on the vessel wall as a function of viscosity and geometry of the vessel, making it a potentially more reliable marker of disease progression.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/fisiopatologia , Hemodinâmica , Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA