Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Clin Immunol ; 257: 109815, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37898413

RESUMO

We report the fatal case of a 20-year-old woman with refractory adult-onset Still's disease (AOSD) accompanied by fulminant macrophage activation syndrome (MAS) and atypical hemolytic uremic syndrome (aHUS). Anakinra and tocilizumab temporarily controlled AOSD. In 2021, she presented to ICU with generalized tonic-clonic seizure, lymphocytic aseptic meningitis, and acute kidney injury. Despite hemodialysis and methylprednisolone, she developed another seizure, MAS, and disseminated intravascular coagulation (DIC). Following brief control, MAS flares -reflected by increased plasma CXCL9 and CXCL10- re-emerged and were controlled through dexamethasone, etoposide, cyclosporin and tofacitinib. No mutations were detected in haemophagocytic lymphohistiocytosis (HLH)-associated genes, nor in genes associated with periodic fever syndromes. Post-mortem genetic testing revealed loss-of-function biallelic deletions in complement factor H-related proteins (CFHR) genes, predisposing aHUS. This case underscores the importance of prompt genetic assessment of complement-encoding alleles, in addition to HLH-related genes, in patients with severe AOSD with recurrent MAS and features of thrombotic microangiopathy (TMA).


Assuntos
Síndrome Hemolítico-Urêmica Atípica , Linfo-Histiocitose Hemofagocítica , Síndrome de Ativação Macrofágica , Doença de Still de Início Tardio , Adulto , Feminino , Humanos , Adulto Jovem , Síndrome de Ativação Macrofágica/genética , Doença de Still de Início Tardio/complicações , Doença de Still de Início Tardio/genética , Síndrome Hemolítico-Urêmica Atípica/genética , Linfo-Histiocitose Hemofagocítica/genética , Ciclosporina/uso terapêutico
2.
Sci Rep ; 13(1): 12383, 2023 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-37524722

RESUMO

Multicellular tumor spheroids embedded in collagen I matrices are common in vitro systems for the study of solid tumors that reflect the physiological environment and complexities of the in vivo environment. While collagen I environments are physiologically relevant and permissive of cell invasion, studying spheroids in such hydrogels presents challenges to key analytical assays and to a wide array of imaging modalities. While this is largely due to the thickness of the 3D hydrogels that in other samples can typically be overcome by sectioning, because of their highly porous nature, collagen I hydrogels are very challenging to section, especially in a manner that preserves the hydrogel network including cell invasion patterns. Here, we describe a novel method for preparing and cryosectioning invasive spheroids in a two-component (collagen I and gelatin) matrix, a technique we term dual-hydrogel in vitro spheroid cryosectioning of three-dimensional samples (DISC-3D). DISC-3D does not require cell fixation, preserves the architecture of invasive spheroids and their surroundings, eliminates imaging challenges, and allows for use of techniques that have infrequently been applied in three-dimensional spheroid analysis, including super-resolution microscopy and mass spectrometry imaging.


Assuntos
Hidrogéis , Neoplasias , Humanos , Hidrogéis/química , Esferoides Celulares , Neoplasias/diagnóstico por imagem , Colágeno Tipo I , Imagem Óptica
3.
Trends Cell Biol ; 32(9): 746-761, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35197210

RESUMO

Peptidylarginine deiminases (PADs) are calcium-dependent enzymes that mediate citrullination, an irreversible post-translational modification (PTM). PAD enzymes have received increasing attention in (patho-)physiology since multi-omics analysis accelerated their expression profiling. Here, we provide a comprehensive overview of PAD expression at the RNA and protein levels, and a list of annotated substrates per PAD isozyme. We discuss novel roles of citrullination in cellular growth, epigenetic regulation, tissue remodeling, inflammation, and cancer in mouse models and humans. Additionally, we cluster similar effects of protein deimination to offer a different perspective and improve our understanding of citrullination in health and disease. Citrullination should no longer be considered as a rare PTM, but as an important regulatory mechanism in physiology and pathology.


Assuntos
Citrulinação , Epigênese Genética , Animais , Humanos , Inflamação , Camundongos , Processamento de Proteína Pós-Traducional , Desiminases de Arginina em Proteínas/genética , Desiminases de Arginina em Proteínas/metabolismo
4.
Hepatol Commun ; 5(10): 1737-1754, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34532999

RESUMO

Hepatic cell death occurs in response to diverse stimuli such as chemical and physical damage. The exposure of intracellular contents such as DNA during necrosis induces a severe inflammatory response that has yet to be fully explored therapeutically. Here, we sought means to neutralize the ability of extracellular DNA to induce deleterious tissue inflammation when drug-induced liver injury had already ensued. DNA exposure and inflammation were investigated in vivo in drug-induced liver injury using intravital microscopy. The necrotic DNA debris was studied in murine livers in vivo and in DNA debris models in vitro by using a positively charged chemokine-derived peptide (MIG30; CXCL9[74-103]). Acetaminophen-induced liver necrosis was associated with massive DNA accumulation, production of CXC chemokines, and neutrophil activation inside the injured tissue. The MIG30 peptide bound the healthy liver vasculature and, to a much greater extent, to DNA-rich necrotic tissue. Moreover, MIG30 bound extracellular DNA directly in vivo in a charge-dependent manner and independently of glycosaminoglycans and chemokines. Post-treatment of mice with MIG30 reduced mortality, liver damage, and inflammation significantly. These effects were not observed with a control peptide that does not bind DNA. Mechanistically, MIG30 inhibited the interaction between DNA and histones, and promoted the dissociation of histones from necrotic debris. MIG30 also inhibited the pro-inflammatory effect of CpG DNA, as measured by a reduction in CXCL8 production, indicating that MIG30 disturbs the ability of DNA to induce hepatic inflammation. Conclusion: The use of DNA-binding peptides reduces necrotic liver injury and inflammation, even at late timepoints.


Assuntos
Anti-Inflamatórios/farmacologia , Doença Hepática Induzida por Substâncias e Drogas/tratamento farmacológico , Degradação Necrótica do DNA/efeitos dos fármacos , Fígado/patologia , Peptídeos/farmacologia , Acetaminofen/efeitos adversos , Animais , Doença Hepática Induzida por Substâncias e Drogas/genética , Quimiocina CXCL9/efeitos dos fármacos , Quimiocinas CXC/efeitos dos fármacos , Modelos Animais de Doenças , Matriz Extracelular/genética , Histonas/efeitos dos fármacos , Humanos , Interleucina-8/efeitos dos fármacos , Fígado/efeitos dos fármacos , Camundongos , Necrose/induzido quimicamente , Necrose/patologia , Ativação de Neutrófilo/efeitos dos fármacos , Eletricidade Estática
5.
Matrix Biol ; 95: 68-83, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33157227

RESUMO

Matrix metalloproteinases (MMPs) are enzymes with critical roles in biology and pathology. Glycosylation, nitrosylation and proteolysis are known posttranslational modifications (PTMs) regulating intrinsically the activities of MMPs. We discovered MMP citrullination by peptidyl arginine deiminases (PADs) as a new PTM. Upon hypercitrullination, MMP-9 acquired a higher affinity for gelatin than control MMP-9. Furthermore, hypercitrullinated proMMP-9 was more efficiently activated by MMP-3 compared to control MMP-9. JNJ0966, a specific therapeutic inhibitor of MMP-9 activation, inhibited the activation of hypercitrullinated proMMP-9 by MMP-3 significantly less in comparison with control proMMP-9. The presence of citrullinated/homocitrullinated MMP-9 was detected in vivo in neutrophil-rich sputum samples of cystic fibrosis patients. In addition to citrullination of MMP-9, we report efficient citrullination of MMP-1 and lower citrullination levels of MMP-3 and MMP-13 by PAD2 in vitro. In conclusion, citrullination of MMPs is a new PTM worthy of additional biochemical and biological studies.


Assuntos
Citrulinação/genética , Fibrose Cística/sangue , Metaloproteinase 3 da Matriz/genética , Metaloproteinase 9 da Matriz/genética , Proteína-Arginina Desiminase do Tipo 2/genética , Fibrose Cística/genética , Fibrose Cística/patologia , Ativação Enzimática/genética , Feminino , Humanos , Hidrolases/genética , Masculino , Metaloproteinase 13 da Matriz/sangue , Metaloproteinase 13 da Matriz/genética , Metaloproteinase 3 da Matriz/sangue , Metaloproteinase 9 da Matriz/sangue , Metaloproteinases da Matriz/genética , Processamento de Proteína Pós-Traducional/genética , Proteína-Arginina Desiminase do Tipo 2/sangue , Escarro/metabolismo
6.
Mol Diagn Ther ; 24(4): 451-460, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32406048

RESUMO

BACKGROUND: Circulating free DNA in plasma is an alternative source of tumor-derived DNA that can be a surrogate for tissue epidermal growth factor receptor (EGFR) testing. OBJECTIVE: We evaluated the analytical performance of the cobas® EGFR Mutation Test v2 (cobas test), a real-time polymerase chain reaction assay designed to detect defined EGFR gene mutations in plasma from patients with advanced non-small cell lung cancer (NSCLC). METHODS: We used K2-ethylenediaminetetraacetic acid plasma samples from NSCLC patients and healthy donors (HDs), along with cell line DNA. Results from a complete technical performance evaluation are described, including a comparison between NSCLC and HD plasma to support the use of surrogate samples and an independent confirmation of the limit of detection (LoD). RESULTS: The cobas test reported an overall percent agreement of approximately 88% for plasma samples when compared with a next-generation sequencing method. The LoD for all EGFR mutations was ≤ 100 copies/mL for plasma samples. An external study confirmed the LoD for exon 19 deletion, L858R, and T790M at ≤ 100 copies/mL using samples derived from NSCLC patient specimens. The cobas test showed linearity between at least 50 and 10,000 copies/mL for plasma samples. An internal repeatability study reported a correct call accuracy of 99.2% for plasma samples. The performance of the cobas test is equivalent when using sheared or intact cell line DNA diluted into either HD plasma or NSCLC patient plasma. CONCLUSIONS: The cobas test is a sensitive, robust, and accurate assay that delivers reproducible results.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/genética , Neoplasias Pulmonares/genética , Mutação/genética , Plasma/metabolismo , Reação em Cadeia da Polimerase em Tempo Real/métodos , Carcinoma Pulmonar de Células não Pequenas/sangue , Linhagem Celular Tumoral , Análise Mutacional de DNA/métodos , DNA de Neoplasias/sangue , Receptores ErbB/sangue , Receptores ErbB/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Neoplasias Pulmonares/sangue , Reprodutibilidade dos Testes
7.
J Thorac Oncol ; 12(8): 1247-1256, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28527899

RESUMO

INTRODUCTION: Osimertinib is an oral, central nervous system-active, EGFR tyrosine kinase inhibitor (TKI) for the treatment of EGFR T790M-positive advanced NSCLC. Here we have evaluated EGFR mutation frequencies in two phase II studies of osimertinib (AURA extension and AURA2). METHODS: After progression while receiving their latest line of therapy, patients with EGFR mutation-positive advanced NSCLC provided tumor samples for mandatory central T790M testing for the study selection criteria. Tumor tissue mutation analysis for patient selection was performed with the Roche cobas EGFR Mutation Test (European Conformity-in vitro diagnostic, labeled investigational use only) (Roche Molecular Systems, Pleasanton, CA). Patients should not have been prescreened for T790M mutation status. The cobas test results were compared with those of the MiSeq next-generation sequencing system (Illumina, San Diego, CA), which was used as a reference method. RESULTS: Samples from 324 and 373 patients screened for AURA extension and AURA2, respectively, produced valid cobas test results. The T790M detection rates were similar between AURA extension and AURA2 (64% and 63%, respectively). The pooled T790M rate was 63%, with no difference by ethnicity (63% for Asian and non-Asian patients alike) or immediately prior treatment with an EGFR TKI (afatinib, 69%; erlotinib, 69%; and gefitinib, 63%). A higher proportion of patients had T790M detected against a background of exon 19 deletions versus L858R mutation (73% versus 58% [p = 0.0002]). In both trials the cobas test demonstrated high sensitivity (positive percent agreement) and specificity (negative percent agreement) for T790M detection when compared with the next-generation sequencing reference method: positive percent agreement of 91% versus 89% and negative percent agreement of 97% versus 98%. CONCLUSIONS: In both trials, the rate of detection of T790M mutation in patients with advanced NSCLC was approximately 63% and was unaffected by immediately prior treatment with an EGFR TKI or ethnicity.


Assuntos
Antineoplásicos/uso terapêutico , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Receptores ErbB/genética , Neoplasias Pulmonares/tratamento farmacológico , Mutação , Piperazinas/uso terapêutico , Inibidores de Proteínas Quinases/uso terapêutico , Acrilamidas , Compostos de Anilina , Carcinoma Pulmonar de Células não Pequenas/enzimologia , Carcinoma Pulmonar de Células não Pequenas/genética , Carcinoma Pulmonar de Células não Pequenas/patologia , Progressão da Doença , Receptores ErbB/antagonistas & inibidores , Humanos , Neoplasias Pulmonares/enzimologia , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patologia , Estudos Prospectivos
8.
J Thorac Oncol ; 12(7): 1061-1070, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28428148

RESUMO

INTRODUCTION: Tumor biopsies for detecting EGFR mutations in advanced NSCLC are invasive, costly, and not always feasible for patients with late-stage disease. The clinical utility of the cobas EGFR Mutation Test v2 (Roche Molecular Systems, Inc., Pleasanton, CA) with plasma samples from patients with NSCLC at disease progression after previous EGFR tyrosine kinase inhibitor therapy was investigated to determine eligibility for osimertinib treatment. METHODS: Matched tumor tissue and plasma samples from patients screened for the AURA extension and AURA2 phase II studies were tested for EGFR mutations by using tissue- and plasma-based cobas EGFR mutation tests. Plasma test performance was assessed by using the cobas tissue test and a next-generation sequencing method (MiSeq [Illumina Inc., San Diego, CA]) as references. The objective response rate, measured by blinded independent central review, was assessed in patients receiving osimertinib with a plasma T790M mutation-positive status. RESULTS: During screening, 551 patients provided matched tumor tissue and plasma samples. Pooled analysis of the positive and negative percent agreements between the cobas plasma and tissue tests for detection of T790M mutation were 61% and 79%, respectively. Comparing cobas plasma test with next-generation sequencing demonstrated positive and negative percent agreements of 90% or higher. The objective response rate was 64% (95% confidence interval: 57-70) in T790M mutation-positive patients by both cobas tissue and plasma tests (evaluable for response). CONCLUSIONS: The cobas plasma test detected the T790M mutation in 61% of tumor tissue T790M mutation-positive patients. To mitigate the risk of false-negative plasma results, patients with a negative plasma result should undergo a tissue test where feasible.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/genética , DNA de Neoplasias/sangue , Receptores ErbB/genética , Neoplasias Pulmonares/genética , Carcinoma Pulmonar de Células não Pequenas/patologia , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Mutação
9.
Oncotarget ; 8(17): 28575-28587, 2017 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-28212573

RESUMO

Small cell lung cancer (SCLC) is one of the most aggressive forms of cancer, with a 5-year survival <7%. A major barrier to progress is the absence of predictive biomarkers for chemotherapy and novel targeted agents such as PARP inhibitors. Using a high-throughput, integrated proteomic, transcriptomic, and genomic analysis of SCLC patient-derived xenografts (PDXs) and profiled cell lines, we identified biomarkers of drug sensitivity and determined their prevalence in patient tumors. In contrast to breast and ovarian cancer, PARP inhibitor response was not associated with mutations in homologous recombination (HR) genes (e.g., BRCA1/2) or HRD scores. Instead, we found several proteomic markers that predicted PDX response, including high levels of SLFN11 and E-cadherin and low ATM. SLFN11 and E-cadherin were also significantly associated with in vitro sensitivity to cisplatin and topoisomerase1/2 inhibitors (all commonly used in SCLC). Treatment with cisplatin or PARP inhibitors downregulated SLFN11 and E-cadherin, possibly explaining the rapid development of therapeutic resistance in SCLC. Supporting their functional role, silencing SLFN11 reduced in vitro sensitivity and drug-induced DNA damage; whereas ATM knockdown or pharmacologic inhibition enhanced sensitivity. Notably, SCLC with mesenchymal phenotypes (i.e., loss of E-cadherin and high epithelial-to-mesenchymal transition (EMT) signature scores) displayed striking alterations in expression of miR200 family and key SCLC genes (e.g., NEUROD1, ASCL1, ALDH1A1, MYCL1). Thus, SLFN11, EMT, and ATM mediate therapeutic response in SCLC and warrant further clinical investigation as predictive biomarkers.


Assuntos
Proteínas Mutadas de Ataxia Telangiectasia/genética , Transição Epitelial-Mesenquimal/genética , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patologia , Proteínas Nucleares/genética , Carcinoma de Pequenas Células do Pulmão/genética , Carcinoma de Pequenas Células do Pulmão/patologia , Proteínas Mutadas de Ataxia Telangiectasia/metabolismo , Biomarcadores , Caderinas/genética , Caderinas/metabolismo , Linhagem Celular Tumoral , Cisplatino/farmacologia , Dano ao DNA , Resistencia a Medicamentos Antineoplásicos/genética , Expressão Gênica , Técnicas de Silenciamento de Genes , Técnicas de Inativação de Genes , Humanos , Imuno-Histoquímica , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/metabolismo , Proteínas Nucleares/metabolismo , Inibidores de Poli(ADP-Ribose) Polimerases/farmacologia , Carcinoma de Pequenas Células do Pulmão/tratamento farmacológico , Carcinoma de Pequenas Células do Pulmão/metabolismo
10.
Mol Diagn Ther ; 20(3): 231-40, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26984642

RESUMO

AIM: Our objective was to assess the performance of the cobas test versus comparators for KRAS mutation status and predicting clinical response to anti-epidermal growth factor receptor (EGFR) therapy in patients with metastatic colorectal cancer (mCRC). METHODS: mCRC samples from 398 patients from Roche study NO16968 (XELOXA) and 82 supplemental samples were tested with the cobas(®) KRAS mutation test (cobas test), the therascreen(®) KRAS RGQ PCR kit test (therascreen test), and Sanger sequencing as the reference method for detecting mutations in codons 12/13. RESULTS: For 461 eligible samples, the cobas test, therascreen test, and sequencing had invalid results for 5.2, 10.8, and 2.6 % of specimens, respectively. Valid cobas and therascreen test results had similar KRAS mutation-positive rates (37.3 vs. 36.3 %, respectively); sequencing was 28.5 %. Positive and negative percent agreement (PPA/NPA) between the cobas test and sequencing was 96.9 % (95 % confidence interval [CI] 92.2-98.8), and 88.7 % (95 % CI 84.7-91.8), respectively. PPA/NPA between the cobas and therascreen tests was 93.3 % (95 % CI 88.1-96.3) and 96.5 % (95 % CI 93.5-98.1), respectively. Bridging analysis from NCIC-CO.17 and NCT00113763 using the cobas test yielded modeled hazard ratios for overall survival and progression-free survival (PFS) of 0.558 (95 % CI 0.422-0.752) and 0.413 (95 % CI 0.304-0.550), respectively, for cetuximab and 0.989 (95 % CI 0.778-1.299) and 0.471 (95 % CI 0.360-0.626), respectively, for panitumumab, demonstrating significant efficacy in the KRAS-negative population for PFS. CONCLUSION: The cobas test showed similar accuracy to the therascreen test for detecting KRAS mutations and could appropriately identify mCRC patients ineligible for anti-EGFR therapy as demonstrated by bridging analysis results.


Assuntos
Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/genética , Mutação , Proteínas ras/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/mortalidade , Análise Mutacional de DNA/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Inibidores de Proteínas Quinases/farmacologia , Inibidores de Proteínas Quinases/uso terapêutico , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise de Sequência de DNA , Resultado do Tratamento
11.
Atmos Chem Phys ; 16(21): 13477-13490, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-29619044

RESUMO

Formaldehyde (HCHO) column data from satellites are widely used as a proxy for emissions of volatile organic compounds (VOCs) but validation of the data has been extremely limited. Here we use highly accurate HCHO aircraft observations from the NASA SEAC4RS campaign over the Southeast US in August-September 2013 to validate and intercompare six retrievals of HCHO columns from four different satellite instruments (OMI, GOME2A, GOME2B and OMPS) and three different research groups. The GEOS-Chem chemical transport model is used as a common intercomparison platform. All retrievals feature a HCHO maximum over Arkansas and Louisiana, consistent with the aircraft observations and reflecting high emissions of biogenic isoprene. The retrievals are also interconsistent in their spatial variability over the Southeast US (r=0.4-0.8 on a 0.5°×0.5° grid) and in their day-to-day variability (r=0.5-0.8). However, all retrievals are biased low in the mean by 20-51%, which would lead to corresponding bias in estimates of isoprene emissions from the satellite data. The smallest bias is for OMI-BIRA, which has high corrected slant columns relative to the other retrievals and low scattering weights in its air mass factor (AMF) calculation. OMI-BIRA has systematic error in its assumed vertical HCHO shape profiles for the AMF calculation and correcting this would eliminate its bias relative to the SEAC4RS data. Our results support the use of satellite HCHO data as a quantitative proxy for isoprene emission after correction of the low mean bias. There is no evident pattern in the bias, suggesting that a uniform correction factor may be applied to the data until better understanding is achieved.

12.
J Prim Health Care ; 5(1): 28-35, 2013 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-23457692

RESUMO

INTRODUCTION: Multiple medications are recommended for the management of ischaemic heart disease. Unfortunately, increasing the number of medicines reduces adherence to medicines therapy. The concept of a polypill with a fixed dose combination of the common cardiovascular medicines (aspirin, statin, two blood pressure-lowering medicines) has been promoted. Patient perceptions about this concept have not been explored. METHODS: People taking at least three cardiovascular medicines were interviewed using a semi-structured interview about their views on a polypill that could reduce the number of tablets they would need to take. FINDINGS: The participants considered that the polypill would be very convenient, especially when travelling and would reduce the pill burden. If the polypill was subsidised by the government, they would have reduced dispensing fee costs. There were concerns around the inflexibility of dosing of individual components of the polypill, and some concerns about safety and efficacy. Medical practitioners were identified as having an important role in influencing participants about the acceptability of the polypill. CONCLUSION: Generally the concept of the polypill was acceptable to participants, primarily because of the convenience and reduced number of tablets required daily. There were concerns about whether the polypill would be as effective and safe as the individual medicines.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doenças Cardiovasculares/tratamento farmacológico , Combinação de Medicamentos , Quimioterapia Combinada , Adesão à Medicação/psicologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/economia , Anti-Hipertensivos/uso terapêutico , Fármacos Cardiovasculares/economia , Fármacos Cardiovasculares/uso terapêutico , Doenças Cardiovasculares/prevenção & controle , Feminino , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/economia , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Entrevistas como Assunto , Masculino , Adesão à Medicação/estatística & dados numéricos , Pessoa de Meia-Idade , Nova Zelândia , Inibidores da Agregação Plaquetária/economia , Inibidores da Agregação Plaquetária/uso terapêutico , Pesquisa Qualitativa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA