Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ann Med Surg (Lond) ; 86(5): 2665-2670, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38694312

RESUMO

Background: The current dilemma of osteosarcoma treatment is the resistance of chemotherapeutic drugs after long-term usage, which also introduces life-threatening side effects. Methods and results: To minimize chemoresistance in osteosarcoma patients, the authors applied shock waves (SWs) to human osteosarcoma MNNG/HOS cells, then evaluated the cell viability and extracellular ATP levels, and further investigated the effect of SWs on cisplatin (DDP) cytotoxicity in MNNG/HOS cells. The authors' results showed that 400 SW pulses at 0.21 mJ/mm2 exhibited little influence on the MNNG/HOS cell viability. In addition, this SW condition significantly promoted the extracellular ATP release in MNNG/HOS cells. Importantly, low-energy SWs obviously increased Akt and mammalian target of rapamycin (mTOR) phosphorylation and activation in MNNG/HOS cells, which could be partially reversed in the presence of P2X7 siRNA. The authors also found that low-energy SWs strongly increased the DDP sensitivity of MNNG/HOS cells in the absence of P2X7. Conclusions: For the first time, the authors found that SW therapy reduced the DDP resistance of MNNG/HOS osteosarcoma cells when the ATP receptor P2X7 was downregulated. SW therapy may provide a novel treatment strategy for chemoresistant human osteosarcoma.

2.
Technol Health Care ; 23(5): 653-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26410126

RESUMO

BACKGROUND: Cannulated screws (4.0 mm) provide inter-fragmentary compression and stability to fractures. A guide wire is used to define the screw trajectory and hold the fracture fragment while the screw is being inserted. The cannulated shaft typically accommodates a 1.25 mm guide pin. Since the guide pin is very slender and undergoes elastic deformation during insertion, there is a high probability of pin breakage. METHODS: The authors have devised a new way to place the 4.0 mm cannulated screws in a manner that prevents the intraoperative complication of guide wire breakage. For this technique, predrilling was achieved using a 2.0 mm K-wire which was subsequently replaced with a 1.25 mm guide pin under the protection of sleeve. 4.0 mm cannulated screws were then inserted into a defined trajectory over the guide pin. RESULTS: Using the technique, over 20 patients were managed in our department over a period of two years without any complications. CONCLUSION: We have observed that patients treated with this method experience short operation time, combined with good clinical outcome and we recommend its use in cases where cannulated screw use is warranted.


Assuntos
Parafusos Ósseos , Fios Ortopédicos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Humanos , Duração da Cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA