1.
ASAIO J
; 67(3): e77-e79, 2021 03 01.
Artigo
em Inglês
| MEDLINE
| ID: mdl-33627614
RESUMO
Mechanical circulatory support has been performed as a bridge to cardiac retransplantation in selected patients with graft failure. However, there is limited published experience on the use and potential benefit of the total artificial heart (TAH) as a bridge to cardiac retransplantation. We report on our institutional experience with 3 patients that received TAH as a bridge to retransplant, with 1 patient surviving post-retransplantation. This case series demonstrates the high-risk nature of this undertaking in cardiac retransplant candidates and highlights the issue of sensitization portending greater risk for poor outcomes after TAH as bridge to retransplantation.
Assuntos
Transplante de Coração/métodos , Coração Artificial , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação