Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39103696

RESUMO

PURPOSE: The current study aimed to describe the distribution of angle alpha and angle kappa offsets as well as their associated ocular biometric parameters in a large population of candidates for cataract surgery. METHODS: This cross-sectional retrospective study included 8,119 eyes of 4,781 candidates for cataract surgery (mean age 70.7 ± 12.9 years). There were 49.9% right eyes, and 53.0% patients were females. The angles offset and ocular biometric parameters were measured by the IOLMaster 700 (Carl Zeiss Meditec, AG, Germany). RESULTS: Patient's age and gender, and most of their ocular biometric measurements were similar for the right and left eyes except for pupil diameter (4.01 ± 1.18 vs. 3.92 ± 1.14 mm, respectively, P < 0.001). The angle alpha offset magnitude was similar for the right and left eyes (0.50 ± 0.20 and 0.51 ± 0.21 mm, P = 0.08), whereas the angle kappa offset magnitude was greater in the right eyes (0.37 ± 0.21 vs. 0.33 ± 0.20 mm, P < 0.001). The angle kappa offset magnitudes were greater in the right eyes compared to the left eyes for both males (0.36 ± 0.21 vs. 0.33 ± 0.21 mm, respectively, P < 0.001) and females (0.37 ± 0.20 vs. 0.34 ± 0.20 mm, respectively, P < 0.001). The offset magnitudes of both angles varied significantly according to gender, eye laterality, angle location, and biometric parameters (e.g., axial length). The offset magnitudes of both angles were positively correlated in both right and left eyes. CONCLUSIONS: The offset magnitudes of both the angle alpha and angle kappa present significant variations according to gender, eye laterality, angle location, and biometric parameters, such as AL. These values are also population-specific.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38958959

RESUMO

PURPOSE: To compare two different datasets, using Eyetemis, an online analytical tool designed for assessing the spherical equivalent prediction errors (SEQ-PE) of intraocular lens (IOL) power calculation formulas following cataract surgery. SETTING: Institutional. DESIGN: Retrospective case series. METHODS: The study was comprised of two distinct datasets of patients who had undergone successful cataract surgery. Dataset-1 includes standard eyes whereas Dataset-2 includes eyes with keratoconus. An online tool was used for SEQ-PE analysis across the 2 datasets, adhering to ISO standards for evaluating accuracy based upon trueness and precision. The tool incorporates robust t-tests for comparing the trimmed-mean of the data, adjusting for heteroscedasticity. IOL constants in Dataset-1 were optimized for the comparison of Hoffer Q, Holladay1, SRK/T, Haigis and Barrett Universal II (BUII) formulas. In Dataset-2, IOL constants from the IOLCon website, were used for the comparison of the BUII and its designated KCN-version: Barrett TrueK Keratoconus (TrueK [KCN]). RESULTS: For Dataset-1: the trimmed-mean SEQ-PE values of all formulas were not significantly different from zero. BUII had superior precision and accuracy compared to all other formulas except from Haigis (P≤ 0.04). For Dataset-2: BUII's trimmed-mean SEQ-PE was significantly different from zero (0.59D, P< 0.01), unlike the TrueK [KCN] (0.12D, P= 0.10). Additionally, TrueK [KCN] exhibited enhanced precision and accuracy relative to BUII (P< 0.01). CONCLUSIONS: The online analysis tool provides a streamlined approach for assessing the prediction accuracy of SEQ refraction following cataract surgery, effectively evaluating trueness, precision, and overall accuracy through the use of advanced statistical methods.

3.
Eur J Ophthalmol ; 34(4): NP20-NP24, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38619930

RESUMO

PURPOSE: This case report aims to report the development of cystoid macular edema (CME) unilaterally following the administration of bimatoprost implant (Durysta) injections in both eyes for the treatment of primary open-angle glaucoma (POAG). OBSERVATIONS: An 84-year-old female patient, previously diagnosed with POAG, underwent bimatoprost implant (Durysta) injections in both eyes, spaced one month apart. Subsequently, the patient experienced a gradual decline in visual acuity in her left eye attributed to the development of CME. The condition resolved following a treatment regimen involving topical dexamethasone and nepafenac. CONCLUSION: The use of bimatoprost implant may lead to the occurrence of CME. Ophthalmologists must vigilantly monitor patients post-implantation, especially if they exhibit visual symptoms or have risk factors for a CME.


Assuntos
Anti-Hipertensivos , Bimatoprost , Implantes de Medicamento , Glaucoma de Ângulo Aberto , Pressão Intraocular , Edema Macular , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Edema Macular/diagnóstico , Edema Macular/tratamento farmacológico , Feminino , Bimatoprost/efeitos adversos , Glaucoma de Ângulo Aberto/tratamento farmacológico , Glaucoma de Ângulo Aberto/cirurgia , Idoso de 80 Anos ou mais , Pressão Intraocular/efeitos dos fármacos , Implantes de Medicamento/efeitos adversos , Anti-Hipertensivos/efeitos adversos , Glucocorticoides/administração & dosagem , Glucocorticoides/efeitos adversos , Glucocorticoides/uso terapêutico , Câmara Anterior , Dexametasona/administração & dosagem , Dexametasona/efeitos adversos
4.
J Cataract Refract Surg ; 50(8): 856-861, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38661494

RESUMO

PURPOSE: To evaluate the clinical significance of preoperative spectral domain optical coherence tomography (OCT) of the retinal nerve fiber layer (RNFL) thickness in identifying glaucoma and better managing patients scheduled for routine cataract surgery. SETTING: Department of Ophthalmology, Shaare Zedek Medical Center, Jerusalem, Israel. DESIGN: Retrospective cohort study. METHODS: Consecutive patients scheduled for cataract surgery were enrolled from February 2022 to August 2022. Participants underwent routine OCT RNFL studies which were evaluated by a glaucoma specialist. Findings were compared with those of preoperative fundus biomicroscopic examinations conducted by the referring ophthalmologist. The main outcomes were the incidence of newly detected glaucoma based on OCT RNFL findings and the consequent changes in patient management. RESULTS: In total, 486 patients met the inclusion criteria of whom 112 (23%) had abnormal RNFL. 31 patients (6.4%) had abnormal OCT RNFL findings attributed to comorbidities other than glaucoma, and 81 patients (16.7%) were suspected to have glaucoma based on their OCT RNFL findings, from which 44 patients (9%) were newly diagnosed with glaucoma or as glaucoma suspects, resulting in management modifications that included routine glaucoma follow-up (25 patients, 5.1%), initiation of intraocular pressure-lowering treatment (12 patients, 2.5%), and conversion to combined cataract-glaucoma surgery (7 patients, 1.4%). CONCLUSIONS: OCT RNFL for cataract surgery candidates proved valuable in detecting glaucoma that had not been revealed by standard fundus biomicroscopic examination. The additional information provided by OCT RNFL can potentially enhance patient management and optimize outcomes.


Assuntos
Extração de Catarata , Glaucoma , Pressão Intraocular , Fibras Nervosas , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Retrospectivos , Fibras Nervosas/patologia , Masculino , Células Ganglionares da Retina/patologia , Feminino , Pressão Intraocular/fisiologia , Idoso , Glaucoma/diagnóstico , Glaucoma/cirurgia , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Período Pré-Operatório
5.
J Cataract Refract Surg ; 50(7): 682-687, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38477800

RESUMO

PURPOSE: To demonstrate the noninferiority in antimicrobial effectiveness of thrice-repeated applications of 1% povidone-iodine (PI) compared with a single application of 5% PI on the ocular surface in vivo and to evaluate potential toxicity of PI to the corneal epithelium. SETTING: Department of Ophthalmology, Shaare Zedek Medical Center, Jerusalem, Israel. DESIGN: Prospective, randomized, double-blind study. METHODS: Patients randomly received either a single application of 5% PI or repeated irrigations of 1% PI on the ocular surface preoperatively. Bacterial colony counts were quantitatively analyzed by taking standardized conjunctival swabs before and after irrigation, and differences in bacterial colony counts were compared between the 2 groups. The presence of superficial punctate keratopathy was evaluated in all patients by the National Eye Institute grading system. RESULTS: The study comprised 102 eyes of 102 patients. Both 1% and 5% PI yielded a marked decrease in bacterial colonies compared with before application ( P < .001). The repeated application of 1% PI showed a significantly lower bacterial count compared with the single application of 5% PI ( P < .05) and resulted in significantly less damage to the corneal epithelium compared with a single 5% PI application ( P < .001). CONCLUSIONS: Preoperative repeated applications of 1% PI effectively eradicated ocular surface bacteria equal to that of 5% PI with a less deleterious effect on the corneal epithelium. Our findings suggest that 1% PI may be a promising alternative to 5% PI.


Assuntos
Anti-Infecciosos Locais , Bactérias , Contagem de Colônia Microbiana , Túnica Conjuntiva , Povidona-Iodo , Humanos , Estudos Prospectivos , Método Duplo-Cego , Anti-Infecciosos Locais/toxicidade , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Bactérias/efeitos dos fármacos , Bactérias/isolamento & purificação , Túnica Conjuntiva/microbiologia , Túnica Conjuntiva/efeitos dos fármacos , Epitélio Corneano/efeitos dos fármacos , Epitélio Corneano/microbiologia , Infecções Oculares Bacterianas/microbiologia , Infecções Oculares Bacterianas/prevenção & controle , Infecções Oculares Bacterianas/tratamento farmacológico , Adulto
6.
Harefuah ; 163(3): 145-150, 2024 Mar.
Artigo em Hebraico | MEDLINE | ID: mdl-38506355

RESUMO

BACKGROUND: A focused bibliographic analysis of Israel's ophthalmology research productivity has never been performed. OBJECTIVES: To assess the research output of Israeli ophthalmology departments between the years 2011-2021 and compare to leading countries in the discipline. METHODS: The PubMed search engine was used to detect all medical articles published between the years 2011 and 2021, with at least one author from an Israeli ophthalmology department. Each entry was reviewed for: year of publication, journal, department, sub-specialty, and study design. Journals were ranked according to Scopus Cite Score. Research output and population data of 7 top-ranked countries in ophthalmology (USA, UK, Japan, Germany, Australia, Canada, China) were documented for comparisons. RESULTS: Overall, 1,919 publications were included. Total research output of Israeli ophthalmology departments significantly increased throughout the study period (R2=0.85, P<0.0001). Medical retina publications were the most prevalent (493 articles, 25.6%), and the most commonly utilized design was cohort (536 articles, 28%). Over a third of all articles (669) were published in Q1 ophthalmology journals, and 16% were published in the top-10 journals. Israel was ranked (1/8) and (3/8) in publications per population and physician, respectively, compared to the other assessed countries. CONCLUSIONS: Between 2011-2021, the research productivity of the Israeli ophthalmological community has constantly increased across all sub-specialties and in high-impact journals. Israel's relative contribution to the ophthalmic medical literature is noteworthy internationally.


Assuntos
Oftalmologia , Humanos , Bibliometria , Alemanha , Internacionalidade , Israel
7.
J Cataract Refract Surg ; 49(12): 1236-1241, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37616179

RESUMO

PURPOSE: To report the intraoperative performance and postoperative outcomes of crystalline lens removal and in-the-bag intraocular lens (IOL) implantation with scleral-bag fixation by means of capsular tension segments (CTSs) and a capsular tension ring (CTR) in patients with a subluxated lens. SETTING: Department of Ophthalmology, Shaare-Zedek Medical Center, Jerusalem, Israel. DESIGN: Retrospective, consecutive case series. METHODS: This study included patients with subluxated crystalline lens who underwent lensectomy or cataract extraction using an anterior chamber maintainer (ACM), a CTR, transscleral capsular-bag fixation by polytetrafluoroethylene suture with 2 CTSs, and in-the-bag IOL implantation. Outcome measures included intra- and postoperative complications, corrected distance visual acuity (CDVA), target and postoperative refraction, and IOL tilt. RESULTS: 17 eyes (9 patients) were included, with a mean follow-up of 22.06 ± 14.88 months. There was a significant improvement in mean logMAR CDVA ( P < .001), with 15 eyes (88.24%) achieving a Snellen CDVA of 20/30 or better and all eyes achieving 20/40 or better. The mean refractive spherical-equivalent prediction error was 0.07 ± 1.10 diopters (D), with 10 (58.82%) and 15 (88.24%) of eyes within ±0.50 D and 1.00 D, respectively, from the intended refraction. The mean horizontal and vertical tilts were 1.9 ± 2.6 degrees and 2.6 ± 2.1 degrees, respectively. No complications were observed except for 1 case of an intraoperative posterior-capsular tear. CONCLUSIONS: A comprehensive surgical approach for scleral-bag fixation that combines the use of an ACM, CTR, polytetrafluoroethylene sutures, 2 CTSs with in-the-bag IOL implantation, offers an effective strategy for achieving favorable visual outcomes and a low incidence of complications in patients with subluxated crystalline lenses.


Assuntos
Cristalino , Lentes Intraoculares , Erros de Refração , Humanos , Implante de Lente Intraocular , Estudos Retrospectivos , Politetrafluoretileno
8.
J Refract Surg ; 39(5): 340-346, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37162397

RESUMO

PURPOSE: To evaluate the differences in corneal wavefront measurements in myopic and hyperopic eyes when calculated using three different reference centers and explore possible influencing factors for such differences. METHODS: Corneal wavefront measurements were performed in myopic and hyperopic eyes using a GALILEI Placido Dual Scheimpflug Analyzer (Ziemer Ophthalmic Systems AG). Corneal higher order aberrations (HOAs), including total, vertical, and horizontal coma-like aberrations, spherical aberrations, and total corneal HOAs through a 6-mm pupil size, were calculated over three different reference center positions: pupil center, corneal vertex, and limbus to limbus. Values were then compared between the myopic and hyper-opic eyes, and correlations with kappa distance and spherical equivalent were tested. RESULTS: A significant decrease in the level of total corneal HOAs (-0.04 ± 0.05 and -0.12 ± 0.09), total corneal coma (-0.07 ± 0.09 and -0.18 ± 0.12), and horizontal coma (-0.07 ± 0.11 and -0.22 ± 0.11) in myopic and hyperopic eyes, respectively, was found when recalculating from pupil center to corneal vertex centration, whereas a significant increase in the same aberrations was observed from pupil center or corneal vertex to limbus to limbus. Significant correlations were found between the kappa distance and changes in total corneal HOAs, total corneal coma, and horizontal coma from the pupil center to the corneal vertex in both groups. CONCLUSIONS: Corneal vertex centration generated the lowest level of corneal wavefront error in both groups. The differences in corneal aberrations between the reference centers for calculation were highly correlated with the kappa distance in hyperopic eyes. [J Refract Surg. 2023;39(5):340-346.].


Assuntos
Aberrações de Frente de Onda da Córnea , Hiperopia , Miopia , Humanos , Coma , Aberrações de Frente de Onda da Córnea/diagnóstico , Córnea , Refração Ocular , Topografia da Córnea
10.
Ocul Surf ; 29: 331-385, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37087043

RESUMO

The word "elective" refers to medications and procedures undertaken by choice or with a lower grade of prioritization. Patients usually use elective medications or undergo elective procedures to treat pathologic conditions or for cosmetic enhancement, impacting their lifestyle positively and, thus, improving their quality of life. However, those interventions can affect the homeostasis of the tear film and ocular surface. Consequently, they generate signs and symptoms that could impair the patient's quality of life. This report describes the impact of elective topical and systemic medications and procedures on the ocular surface and the underlying mechanisms. Moreover, elective procedures performed for ocular diseases, cosmetic enhancement, and non-ophthalmic interventions, such as radiotherapy and bariatric surgery, are discussed. The report also evaluates significant anatomical and biological consequences of non-urgent interventions to the ocular surface, such as neuropathic and neurotrophic keratopathies. Besides that, it provides an overview of the prophylaxis and management of pathological conditions resulting from the studied interventions and suggests areas for future research. The report also contains a systematic review investigating the quality of life among people who have undergone small incision lenticule extraction (SMILE). Overall, SMILE refractive surgery seems to cause more vision disturbances than LASIK in the first month post-surgery, but less dry eye symptoms in long-term follow up.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Estilo de Vida , Miopia/cirurgia , Qualidade de Vida , Lágrimas
11.
J Clin Med ; 12(5)2023 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-36902566

RESUMO

This retrospective comparative study analyzes the early postoperative impact of laser vision correction for myopia on the optical quality and stability of functional vision using a double-pass aberrometer. Retinal image quality and visual function stability were assessed preoperatively, one and three months after myopic laser in situ keratomileuses (LASIK) and photorefractive keratectomy (PRK) using double-pass aberrometry (HD Analyzer, Visiometrics S.L, Terrassa, Spain). The parameters analyzed included vision break-up time (VBUT), objective scattering index (OSI), modulation transfer function (MTF), and Strehl ratio (SR). The study included 141 eyes of 141 patients, of whom 89 underwent PRK and 52 underwent LASIK. No statistically significant differences were noted between the two techniques in any analyzed parameters at three months postoperatively. However, a significant drop was observed in all parameters one month after PRK. Only the OSI and VBUT remained significantly altered from baseline at the three months follow-up visit, with an increased OSI by 0.14 +/- 0.36 (p < 0.01) and a shortened VBUT by 0.57 +/- 2.3 s (p < 0.01). No correlation was found between the changes in optical and visual quality parameters and age, ablation depth, or postoperative spherical equivalent. The stability and quality of the retinal images were similar between LASIK and PRK at three months postoperatively. However, significant degradation in all parameters was found one month after PRK.

12.
J Cataract Refract Surg ; 49(3): 229-233, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36314969

RESUMO

PURPOSE: To compare the prediction accuracy of the Barrett True-K for keratoconus with standard formulas (SRK/T, Barrett Universal II, and Kane) and the Kane keratoconus formula. SETTING: Shaare Zedek Medical Center, Jerusalem, Israel, and University Eye Clinic, Maastricht, the Netherlands. DESIGN: Multicenter retrospective case series. METHODS: Eyes with stable keratoconus undergoing cataract surgery were included. The predicted refractions were calculated for SRK/T, Barrett Universal II, Barrett True-K for keratoconus (predicted and measured), Kane, and Kane adjusted for keratoconus formulas. Primary outcomes were prediction error (PE), absolute error (AE), and percentage of eyes with PE ±0.25 diopters (D), ±0.50 D, and ±1.00 D. Subgroup analyses were performed based on the severity of the keratoconus. RESULTS: 57 eyes were included in the study. The PE was not significantly different from zero for SRK/T, Barrett True-K (predicted and measured), and Kane keratoconus formulas (range 0.09 to 0.22 D, P > .05). The AE of Barrett True-K predicted (median 0.14 D) and Barrett True-K measured (median 0.10 D) were significantly lower from Barrett Universal II (median 0.47 D) and Kane (median 0.50 D), P < .001. CONCLUSIONS: The Barrett True-K formulas for keratoconus had higher prediction accuracy as compared with new generation formulas and a similar prediction accuracy as compared with the Kane keratoconus formula.


Assuntos
Ceratocone , Lentes Intraoculares , Facoemulsificação , Humanos , Ceratocone/cirurgia , Refração Ocular , Estudos Retrospectivos , Óptica e Fotônica , Biometria , Comprimento Axial do Olho
13.
Workplace Health Saf ; 71(1): 6-12, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35673758

RESUMO

BACKGROUND: Ophthalmology practice entails many hours of physical inactivity, a potential long-term health hazard. This study aims to perform a pedometer-based evaluation of the physical activity (PA) levels of ophthalmologists at work. METHODS: This is a prospective observational study. Ophthalmologists from a single tertiary medical center were monitored with electronic pedometers during six morning sessions in the ophthalmology clinics. Working hours and the number of patients seen per clinic session were retrieved. The age and body mass index (BMI) of participants were documented. Step number per working hour (SPH) was calculated for all participants. Comparisons between males and females, practicing ophthalmologists (attendings) and ophthalmology residents (residents), and sub-specialties were performed. Correlations between SPH and age, BMI, and patients seen per clinic session were computed. FINDINGS: Pedometer readings for a total of 673 working hours were analyzed for 24 ophthalmologists, 17% female, 17 attendings, mean age 44.2 years (standard deviation (SD = 9.8). The average number of SPH for all participants was 359.7 (SD = 166.7). The mean PA level of residents was significantly higher than that of attendings (410.17 SPH vs. 338.95 SPH, respectively, p = .019). Oculoplastic surgeons demonstrated significantly higher step counts per hour than cornea specialists (439.90 SPH vs. 245.55 SPH, respectively, p = .002). A negative correlation was observed between SPH and the number of patients seen per clinic session (ρ = -0.274, p = .001). CONCLUSIONS/APPLICATIONS TO PRACTICE: Low number of SPH for ophthalmologists in this study indicates ophthalmology to be a highly sedentary medical occupation. PA levels of ophthalmologists in the workplace may indicate a personal health care challenge.


Assuntos
Oftalmologistas , Oftalmologia , Masculino , Humanos , Feminino , Adulto , Actigrafia , Comportamento Sedentário , Exercício Físico
14.
J Cataract Refract Surg ; 48(11): 1248-1252, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35514045

RESUMO

PURPOSE: To evaluate the effect of pharmacologic pupil dilation on the quality of axial length (AL) measurement in patients with dense cataracts and previous low-quality AL measurements performed without dilation. SETTING: Shaare-Zedek Medical Center, Jerusalem, Israel. DESIGN: Retrospective case series. METHODS: All participants underwent swept-source optical coherence tomographic (SS-OCT) biometry. Those with low-quality AL measurements due to dense cataract underwent an additional SS-OCT biometric evaluation after pupil dilation, and the AL measurement of the same eye was recorded. RESULTS: 2076 patients underwent SS-OCT during the study period, and 177 (8.52%) had low-quality AL measurements because of dense cataract. 79 (44.63%, mean age 72.53 ± 13.27 years, 43 females) of those 177 patients underwent repeat SS-OCT biometric imaging after pharmacologic pupil dilation, and formed the study group. After pupil dilation, high-quality AL measurements were successfully obtained in 60 (75.95%) of the 79 eyes. The mean SD of the AL measurements decreased significantly ( P &lt; .001), and the number of successful OCT scans per measurement increased significantly ( P &lt; .001) after pupil dilation. The mean difference of the AL before and after pupil dilation was 0.03 ± 0.07 mm ( P &lt; .001). CONCLUSIONS: Pharmacologic pupil dilation improved the quality of SS-OCT biometrically measured AL in patients with low-quality AL measurement due to dense cataract. These results could potentially improve postoperative refractive outcomes after cataract surgery and reduce the need of additional AL measurements by more complicated alternative means in this group.


Assuntos
Comprimento Axial do Olho , Catarata , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Comprimento Axial do Olho/anatomia & histologia , Pupila , Estudos Retrospectivos , Catarata/diagnóstico , Biometria/métodos , Tomografia de Coerência Óptica/métodos , Reprodutibilidade dos Testes
15.
Am J Ophthalmol ; 240: 225-231, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35288068

RESUMO

PURPOSE: To compare standard and total corneal astigmatism measurements to the predicted pseudophakic (nontoric) refractive astigmatism in candidates for cataract surgery. DESIGN: A retrospective, cross-sectional study. METHODS: A single-center analysis of consecutive eyes measured with a swept-source optical coherence tomography biometer at a large tertiary medical center between February 2018 and June 2020. Corneal astigmatism was calculated based on standard keratometry astigmatism (KA), total corneal astigmatism (TCA), and predicted refractive astigmatism (PRA) for a monofocal nontoric intraocular lens (IOL) implantation calculated by the Barrett toric calculator using the predicted posterior corneal astigmatism (PRA(Predicted-PCA)) and the measured posterior corneal astigmatism (PRA(Measured-PCA)) options. Separate analyses were performed for each eye. SETTING: Ophthalmology Department, Shaare Zedek Medical Center, Jerusalem, Israel. RESULTS: In total, 8152 eyes of 5320 patients (4221 right eyes [OD] and 3931 left eyes [OS], mean age 70.6±12.2 years, 54.2% females) were included in the study. The mean vector values (centroid) for KA, TCA, PRA(Predicted-PCA), and PRA(Measured-PCA) were 0.07 diopters [D] at 19.5°, 0.27 D at 7.5°, 0.44 D at 2.9°, and 0.43 D at 179.3°, respectively (P < .01), for OD and 0.02 D at 150.3°, 0.23 D at 169.7°, 0.40 D at 179.4°, and 0.42 D at 169.5°, respectively (P < .01), for OS. More than 73% of eyes had a PRA >0.5 D. CONCLUSIONS: Standard and total corneal astigmatism measurements differ significantly from the PRA by the Barrett toric calculator. The PRA, rather than the KA or TCA, should be used as the reference guide for astigmatism correction with toric IOL implantation.


Assuntos
Astigmatismo , Catarata , Doenças da Córnea , Lentes Intraoculares , Oftalmologia , Facoemulsificação , Idoso , Idoso de 80 Anos ou mais , Astigmatismo/diagnóstico , Astigmatismo/cirurgia , Córnea , Doenças da Córnea/cirurgia , Topografia da Córnea , Estudos Transversais , Feminino , Humanos , Implante de Lente Intraocular/métodos , Masculino , Pessoa de Meia-Idade , Refração Ocular , Estudos Retrospectivos
16.
Graefes Arch Clin Exp Ophthalmol ; 260(6): 1907-1914, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35013800

RESUMO

PURPOSE: To assess the impact of COVID-19-related delay in intravitreal injection timing on macular structure and visual acuity (VA) among patients treated for neovascular age-related macular degeneration (nvAMD). METHODS: We reviewed demographic and clinical data and macular ocular computerized tomographic images of 34 patients (48 eyes, group A) who did not follow their injection schedule during the first wave of COVID-19 and compared them to 46 patients (71 eyes, group B) who did. Functional worsening was defined as a loss of at least 0.1 in decimal VA. Anatomic worsening was defined as new or increased subretinal/intraretinal fluids or new hemorrhage. RESULTS: The planned mean ± standard deviation intervals between the intravitreal injections were 5.7 ± 2.7 weeks for group A and 5.5 ± 2.4 weeks for group B (P = 0.60). The actual intervals were 13.6 ± 6.8 (7.9 ± 5.2 weeks' delay) and 5.3 ± 2.4 weeks (no delay), respectively (P < 0.001). The best corrected visual acuity worsened in 23 group A eyes (47.9%) and in 6 group B eyes (8.5%) (odds ratio [OR] 9.97, P < 0.001). Anatomic features indicative of nvAMD worsening were detected in 31 group A eyes (64.6%) and in 16 group B eyes (22.5%) (OR 5.73, P < 0.001). A new macular hemorrhage was observed in 4 group A eyes (8.3%) and in no group B eyes (P = 0.09). CONCLUSION: Delay in timely retinal care during the COVID-19 restrictions period resulted in short-term negative outcomes, including macular bleeding, in nvAMD patients.


Assuntos
COVID-19 , Degeneração Macular , Degeneração Macular Exsudativa , Inibidores da Angiogênese , Seguimentos , Humanos , Injeções Intravítreas , Degeneração Macular/tratamento farmacológico , Ranibizumab , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Fator A de Crescimento do Endotélio Vascular , Fatores de Crescimento do Endotélio Vascular , Degeneração Macular Exsudativa/diagnóstico , Degeneração Macular Exsudativa/tratamento farmacológico
17.
J Cataract Refract Surg ; 48(1): 37-43, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34016821

RESUMO

PURPOSE: To evaluate the accuracy of the Hill-RBF 3 formula, with and without direct measurements of total corneal power, using a heteroscedastic statistical method for analysis. SETTING: Department of Ophthalmology, Shaare Zedek Medical Center, Jerusalem, Israel. DESIGN: Retrospective, consecutive case series. METHODS: Records of consecutive patients who underwent routine cataract surgery between February 2018 and June 2020 were retrospectively reviewed. The prediction accuracy of the Hill-RBF 3.0 formula was compared with that of the Barrett Universal II, Emmetropia Verifying Optical 2.0, Haigis, Hill-RBF 2.0, Hoffer Q, Holladay 1, Holladay 2, Kane, Olsen, and SRK/T formulas, based on biometry measurements by swept-source optical coherence tomography (SS-OCT) with standard keratometry (K), SS-OCT with total keratometry (TK), and an optical low-coherence reflectometer (OLCR). Statistical analysis was applied according to a heteroscedastic statistical method with SD of prediction errors as the main parameter for formula performance. RESULTS: The study included 153 eyes of 153 patients. The SD values that were obtained by Hill-RBF 3.0 (0.266 to 0.285 diopters [D]) were significantly lower compared with those by Hill-RBF 2.0 (0.290 to 0.309 D), Hoffer Q (0.387 to 0.407 D), Holladay 1 (0.367 to 0.385 D), Holladay 2 (0.386 to 0.401 D), and SRK/T (0.377 to 0.399 D) formulas (P < .036). The prediction accuracy of the Hill-RBF 3.0 was similar across the SS-OCT (K), SS-OCT (TK), and OLCR methods of measurement (P > .51). CONCLUSIONS: The Hill-RBF 3.0 was more accurate than the Hill-RBF 2.0 and older generation formulas and had similar prediction accuracy compared with new generation formulas. The use of TK did not provide significant improvement to its prediction accuracy.


Assuntos
Lentes Intraoculares , Facoemulsificação , Comprimento Axial do Olho , Biometria , Humanos , Óptica e Fotônica , Refração Ocular , Estudos Retrospectivos
18.
Can J Ophthalmol ; 57(3): 147-153, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34052223

RESUMO

OBJECTIVE: To characterize the association between prolonged supine postoperative positioning of patients undergoing Descemet-stripping automated endothelial keratoplasty (DSAEK) and graft dislocation rate. METHODS: In this retrospective cohort study, medical records of patients who underwent uncomplicated DSAEK surgery at Yitzhak Shamir Medical Center between 2010 and 2019 were reviewed. Nursing documentation of patients' adherence to supine positioning during the postoperative hospitalization period was collected. A patient was considered compliant if he or she was documented as cooperative with supine positioning throughout the first 24 hours. RESULTS: A total of 170 eyes of 138 patients were found eligible. Main indications for surgery were pseudophakic bullous keratopathy (50.6%), previous graft failure (25.9%), and Fuch's endothelial dystrophy (FED; 20.6%). Twelve surgeries were combined with cataract extraction. Postoperative graft detachment occurred in 26 eyes (15.3%) after an average period of 1 day (range, 0-20 days). Compliance with supine positioning was documented in 84.1% (n = 143 patients). Noncompliance rates during the first 24 hours in the detached and nondetached groups were 26.9% (n = 7) and 14.4% (n = 20), respectively; after adjustment for possible confounders, the odds ratio (OR) was 1.44 (p = 0.249). Graft dislocation was observed in 13.3% (19 of 143) and 25.9% (7 of 27) of cooperative and noncooperative patients, respectively (p = 0.17). Subanalysis of 120 eyes with either BPK or FED for which it was the first transplantation demonstrated a protective effect of supine positioning (OR 3.42, confidence interval 1.095-10.700; p = 0.034). Findings for both groups remained unchanged in multivariate analysis. CONCLUSIONS: We found a statistically significant protective effect of 24 hours of postoperative supine positioning against graft detachment after DSAEK in eyes with no prior transplantations.


Assuntos
Doenças da Córnea , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Distrofia Endotelial de Fuchs , Doenças da Córnea/cirurgia , Endotélio Corneano , Feminino , Distrofia Endotelial de Fuchs/cirurgia , Sobrevivência de Enxerto , Humanos , Estudos Retrospectivos , Decúbito Dorsal , Acuidade Visual
19.
Eur J Ophthalmol ; 32(3): 1482-1490, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34058903

RESUMO

BACKGROUND: Retrospective cohort study evaluating long term keratoconus progression amongst cross-linking (CXL) treated pediatric patients in the treated and the fellow untreated eyes. METHODS: Data on 60 eyes of 30 patients, 18 years old or younger, who underwent CXL in at least one eye was collected and analyzed. Follow-up measurements taken from the treated and untreated eye up to 7 years after CXL treatment, were compared to baseline measurements. Parameters included uncorrected distance visual acuity (UCDVA), best-corrected spectacle visual acuity (BCSVA), manifest refraction, pachymetry, corneal tomography, and topography. RESULTS: Mean age of patients was 16 ± 2.1 years. For the treated eyes, during follow-up period mean UCDVA had improved (from 0.78 ± 0.22 at baseline to 0.58 ± 0.26 logMAR at 7 years; p = 0.13), as well as mean BCSVA (from 0.23 ± 0.107 at baseline to 0.172 ± 0.05 logMAR at 7 years; p = 0.37). The mean average keratometry showed a significant flattening (from 49.95 ± 4.04 to 47.94 ± 3.3 diopters (D); p < 0.001), However there was no change in the mean maximal keratometry. The mean minimal corneal thickness (MCT) showed a significant mild reduction of 26 µm (p = 0.006). Although statistically insignificant, the mean manifest cylinder was also reduced to 2D (p = 0.15). During the follow-up period, eight untreated eyes (26.6%) deteriorated and underwent CXL, while only one treated eye (3.33%) required an additional CXL. CONCLUSION: CXL is a safe and efficient procedure in halting keratoconus progression in the pediatric population, the fellow eye needs to be carefully monitored but only a 25% of the patients will require CXL in that eye during a period of 7 years.


Assuntos
Ceratocone , Fotoquimioterapia , Adolescente , Criança , Colágeno/uso terapêutico , Topografia da Córnea , Reagentes de Ligações Cruzadas/uso terapêutico , Seguimentos , Humanos , Ceratocone/diagnóstico , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Retrospectivos , Riboflavina/uso terapêutico , Raios Ultravioleta
20.
Am J Ophthalmol ; 233: 38-47, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34314687

RESUMO

PURPOSE: To study the distribution of ocular biometric parameters using a swept-source optical coherence tomography (SS-OCT) biometer in adult candidates for cataract surgery. DESIGN: A retrospective cross-sectional study. METHODS: This is a single-center analysis of consecutive eyes measured with the IOLMaster 700 SS-OCT biometer at a large tertiary medical center between February 2018 and June 2020. RESULTS: Three thousand eight hundred thirty-six eyes of 3836 patients were included in the study. The mean ± SD age was 72.3 ± 12.8 years and 53% were female. The mean biometric values were as follows: total corneal power (44.17 ± 1.70 diopters [D]), total corneal astigmatism (TCA; 1.11 ± 0.87 D), mean posterior keratometry (-5.87 ± 0.26 D), posterior corneal astigmatism (-0.26 ± 0.15 D), axial length (AL; 23.95 ± 1.66 mm), anterior chamber depth (ACD; 3.18 ± 0.42 mm), lens thickness (LT; 4.49 ± 0.47 mm), white-to-white distance (WTW; 11.92 ± 0.44 mm), central corneal thickness (CCT; 0.54 ± 0.04 mm), angle alpha (0.49 ± 0.17 mm), and angle kappa (0.34 ± 0.17 mm). There were sex-related differences in all biometric parameters save for LT (P = .440), angle kappa (P = .216), and corneal astigmatism (P = .103). Biometric parameters demonstrated correlations between AL, WTW distance, ACD, and LT (P < .001). Age correlated with all parameters (P < .001) except CCT and posterior keratometry. Angle alpha and angle kappa magnitudes also correlated (P < .001). The prevalence of patients with TCA ≥0.75 D, 1.0 D, and 1.5 D were 59.1%, 43.4%, and 22.6%, respectively. CONCLUSIONS: Age significantly correlated with most of the biometric parameters and significant differences between sexes were noted. In addition, the high prevalence of TCA and relatively large angle alpha and angle kappa magnitudes were noted among subjects. These data can be relevant in planning local and national health economics.


Assuntos
Catarata , Tomografia de Coerência Óptica , Adulto , Idoso , Idoso de 80 Anos ou mais , Câmara Anterior/anatomia & histologia , Câmara Anterior/diagnóstico por imagem , Comprimento Axial do Olho/anatomia & histologia , Biometria , Estudos Transversais , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA