Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Europace ; 23(7): 1106-1113, 2021 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-33842972

RESUMO

Novel wearable devices for heart rhythm analysis using either photoplethysmography (PPG) or electrocardiogram (ECG) are in daily clinical practice. This survey aimed to assess impact of these technologies on physicians' clinical decision-making and to define, how data from these devices should be presented and integrated into clinical practice. The online survey included 22 questions, focusing on the diagnosis of atrial fibrillation (AF) based on wearable rhythm device recordings, suitable indications for wearable rhythm devices, data presentation and processing, reimbursement, and future perspectives. A total of 539 respondents {median age 38 [interquartile range (IQR) 34-46] years, 29% female} from 51 countries world-wide completed the survey. Whilst most respondents would diagnose AF (83%), fewer would initiate oral anticoagulation therapy based on a single-lead ECG tracing. Significantly fewer still (27%) would make the diagnosis based on PPG-based tracing. Wearable ECG technology is acceptable for the majority of respondents for screening, diagnostics, monitoring, and follow-up of arrhythmia patients, while respondents were more reluctant to use PPG technology for these indications. Most respondents (74%) would advocate systematic screening for AF using wearable rhythm devices, starting at patients' median age of 60 (IQR 50-65) years. Thirty-six percent of respondents stated that there is no reimbursement for diagnostics involving wearable rhythm devices in their countries. Most respondents (56.4%) believe that costs of wearable rhythm devices should be shared between patients and insurances. Wearable single- or multiple-lead ECG technology is accepted for multiple indications in current clinical practice and triggers AF diagnosis and treatment. The unmet needs that call for action are reimbursement plans and integration of wearable rhythm device data into patient's files and hospital information systems.


Assuntos
Fibrilação Atrial , Dispositivos Eletrônicos Vestíveis , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Tomada de Decisão Clínica , Eletrocardiografia , Feminino , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Fotopletismografia
2.
Heart Rhythm ; 18(6): 862-870, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33610744

RESUMO

BACKGROUND: Noncontact charge-density mapping allows rapid real-time global mapping of atrial fibrillation (AF), offering the opportunity for a personalized ablation strategy. OBJECTIVE: The purpose of this study was to compare the 2-year outcome of an individualized strategy consisting of pulmonary vein isolation (PVI) plus core-to-boundary ablation (targeting the conduction pattern core with an extension to the nearest nonconducting boundary) guided by charge-density mapping, with an empirical PVI plus posterior wall electrical isolation (PWI) strategy. METHODS: Forty patients (age 62 ± 12 years; 29 male) with persistent AF (10 ± 5 months) prospectively underwent charge-density mapping-guided PVI, followed by core-to-boundary stepwise ablation until termination of AF or depletion of identified cores. Freedom from AF/atrial tachycardia (AT) at 24 months was compared with a propensity score-matched control group of 80 patients with empirical PVI + PWI guided by conventional contact mapping. RESULTS: Acute AF termination occurred in 8 of 40 patients after charge-density mapping-guided PVI alone and in 21 of the remaining 32 patients after core-to-boundary ablation in the study cohort, compared with 8 of 80 (10%) in the control cohort (P <.001). On average, 2.2 ± 0.6 cores were ablated post-PVI before acute AF termination. At 24 months, freedom from AF/AT after a single procedure was 68% in the study group vs 46% in the control group (P = .043). CONCLUSION: An individualized ablation strategy consisting of PVI plus core-to-boundary ablation guided by noncontact charge-density mapping is a feasible and effective strategy for treating persistent AF, with a favorable 24-month outcome.


Assuntos
Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/normas , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/normas , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Prospectivos , Recidiva , Fatores de Tempo , Resultado do Tratamento
4.
JACC Clin Electrophysiol ; 3(4): 393-402, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28596994

RESUMO

INTRODUCTION: The role of atrial fibrillation (AF) substrates is unclear in patients with paroxysmal AF (PAF) that recurs after pulmonary vein isolation (PVI). We hypothesized that patients with recurrent post-ablation (redo) PAF despite PVI have electrical substrates marked by rotors and focal sources, and structural substrates that resemble persistent AF more than patients with (de novo) PAF at first ablation. METHODS: In 175 patients at 11 centers, we compared AF substrates in both atria using 64 pole-basket catheters and phase mapping, and indices of anatomical remodeling between patients with de novo or redo PAF and first ablation for persistent AF. RESULTS: Sources were seen in all patients. More patients with de novo PAF (78.0%) had sources near PVs than patients with redo PAF (47.4%, p=0.005) or persistent AF (46.9%, p=0.001). The total number of sources per patient (p=0.444), and number of non-PV sources (p=0.701) were similar between groups, indicating that redo PAF patients had residual non-PV sources after elimination of PV sources by prior PVI. Structurally, left atrial size did not separate de novo from redo PAF (49.5±9.5 vs. 49.0±7.1mm, p=0.956) but was larger in patients with persistent AF (55.2±8.4mm, p=0.001). CONCLUSIONS: Patients with paroxysmal AF despite prior PVI show electrical substrates that resemble persistent AF more closely than patients with paroxysmal AF at first ablation. Notably, these subgroups of paroxysmal AF are indistinguishable by structural indices. These data motivate studies of trigger versus substrate mechanisms for patients with recurrent paroxysmal AF after PVI.


Assuntos
Fibrilação Atrial/patologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Humanos , Recidiva , Reoperação , Resultado do Tratamento
5.
Int J Cardiol ; 220: 580-8, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27390994

RESUMO

BACKGROUND: Post-operative atrial fibrillation (POAF) is a major health economic burden. However, the precise mechanisms in POAF remain unclear. In other forms of AF, sites of high dominant frequency (DF) in sinus rhythm (SR) may harbour 'AF nests'. We studied AF inducibility in relation to substrate changes using epicardial electrograms and cardiomyocyte calcium handling in the atria of AF naïve patients. METHOD: Bipolar electrograms were recorded from the lateral right atrial (RA) wall in 34 patients undergoing coronary surgery using a high-density array in sinus rhythm (NSR). RA burst pacing at 200/500/1000ms cycle lengths (CL) was performed, recording episodes of AF>30s. Co-localised RA tissue was snap frozen for RNA and protein extraction. RESULTS: Electrograms prolonged during AF (76.64±29.35ms) vs. NSR/pacing (p<0.001). Compared to NSR, electrogram amplitude was reduced during AF and during pacing at 200ms CL (p<0.001). Electrogram DF was significantly lower in AF (75.87±23.63Hz) vs. NSR (89.33±25.99Hz) (p<0.05), and NSR DF higher in AF inducible patients at the site of AF initiation (p<0.05). Structurally, POAF atrial myocardium demonstrated reduced sarcolipin gene (p=0.0080) and protein (p=0.0242) expression vs. NSR. Phospholamban gene and protein expression was unchanged. SERCA2a protein expression remained unchanged, but MYH6 (p=0.0297) and SERCA2A (p=0.0343) gene expression was reduced in POAF. CONCLUSIONS: Human atrial electrograms prolong and reduce in amplitude in induced peri-operative AF vs. NSR or pacing. In those sustaining AF, high DF sites in NSR may indicate 'AF nests'. This electrical remodelling is accompanied by structural remodelling with altered expression of cardiomyocyte calcium handling detectable before POAF. These novel upstream substrate changes offer a novel mechanism and manifestation of human POAF.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Átrios do Coração/fisiopatologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Idoso , Função do Átrio Direito/fisiologia , Estudos de Coortes , Feminino , Átrios do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA