Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Clin Radiol ; 79(6): e785-e790, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38388255

RESUMO

AIM: To evaluate if real-time dose visualisation during computed tomography (CT)-guided interventions leads to a reduction in radiation dose to participating radiologists. MATERIALS AND METHODS: The individual radiation dose radiologists are exposed to during CT interventions was measured using dedicated dosimeters (RaySafe i2-system, Unfors RaySafe GmbH, Billdal, Sweden) worn over the usual radiation protective apron. Initially, only the total radiation dose was measured, without visualisation (control group). In the following study period, the radiation dose was shown to participants on a live screen in real-time (experimental group). In both groups, the dose was recorded in 1-second intervals. The results collected were evaluated by comparison using descriptive statistics and mixed-effect models. In particular, the variables experience, gender, role, and position during the intervention were analysed. RESULTS: In total, 517 measurements of 304 interventions (n=249 with and n=268 without live screen) performed by 29 radiologists acting as interventionalists or assistants were analysed. All CT-guided interventions were performed percutaneously, the majority of which (n=280) were microwave ablations (MWA). Radiation doses in the group without visualisation were comparable with usual dose rates for the corresponding intervention type. The mean total radiation dose was reduced by 58.1% (11.6 versus 4.86 µSv) in the experimental group (p=0.034). The highest reduction of 78.5% (15.55 versus 3.35 µSv) was observed in radiologists with the role of assistant (p=0.002). Sub-analysis showed significant dose reduction (p<0.0001) for the use of live screen in general; considering all variables, the role "assistant" alone had a statistically significant influence (p=0.002). CONCLUSION: The real-time visualisation of active radiation dose during CT interventions leads to a relevant reduction in radiation dose to participating radiologists.


Assuntos
Exposição Ocupacional , Doses de Radiação , Proteção Radiológica , Radiologistas , Tomografia Computadorizada por Raios X , Humanos , Feminino , Tomografia Computadorizada por Raios X/métodos , Proteção Radiológica/métodos , Masculino , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/análise , Radiografia Intervencionista/métodos , Adulto , Pessoa de Meia-Idade
2.
Eur J Radiol ; 86: 20-25, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28027748

RESUMO

PURPOSE: To evaluate the impact of controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) volume interpolated breath-hold examination (VIBE) magnetic resonance imaging (MRI) technique on image quality, reader confidence, and inter-observer agreement for the assessment of focal liver lesions in comparison with the standard VIBE approach. MATERIAL AND METHODS: In this IRB-approved intra-individual comparison study, abdominal arterial and portal-venous contrast-enhanced MRI studies were retrospectively analyzed in 38 patients with malignant liver lesions. Each patient underwent both CAIPIRINHA and conventional VIBE 3T MRI within 3 months, showing stable disease. Images were evaluated using 5-point rating scales by two blinded radiologists with more than 20 and 5 years of experience in MRI, respectively. Readers scored dignity of liver lesions and assessed which liver segments were affected by malignancy (ranging from 1=definitely benign/not affected to 5=definitely malignant/affected by malignancy). Readers also rated overall image quality, sharpness of intrahepatic veins, and diagnostic confidence (ranging from 1=poor to 5=excellent). RESULTS: Reviewers achieved a higher inter-observer reliability using CAIPIRINHA when they reported which liver segments were affected by malignancy compared to traditional VIBE series (κ=0.62 and 0.54, respectively, p<0.05). Similarly, CAIPIRINHA showed a slightly higher inter-rater agreement for the dignity of focal liver lesions versus the standard VIBE images (κ=0.50 and 0.49, respectively, p<0.05). CAIPIRINHA series also scored higher in comparison to standard VIBE sequences (mean scores: image quality, 4.2 and 3.5; sharpness of intrahepatic vessels, 3.8 and 3.2, respectively, p<0.05) for both reviewers and allowed for higher subjective diagnostic confidence (ratings, 3.8 and 3.2, respectively, p<0.05). CONCLUSION: Compared to the standard VIBE approach, CAIPIRINHA VIBE technique provides improved image quality and sharpness of intrahepatic veins, as well as higher diagnostic confidence. Additionally, this technique allows for higher inter-observer agreement when reporting focal liver lesions for both dignity and allocation.


Assuntos
Hepatopatias/diagnóstico , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Suspensão da Respiração , Meios de Contraste , Feminino , Artéria Hepática/patologia , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Veia Porta/patologia , Reprodutibilidade dos Testes
3.
Clin Radiol ; 71(10): 997-1004, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27426675

RESUMO

AIM: To evaluate the feasibility and accuracy of minimally invasive, transpedicular screw placement in cervicothoracic fractures with the help of computed tomography (CT)-controlled guidewires. MATERIALS AND METHODS: Two hundred and ninety-three guidewires were inserted in 35 patients (42.9±21.2 years) under CT fluoroscopy (286 thoracic, seven cervical). There were 28 traumatic cases, three pathological fractures, three fractures due to infectious infiltrations, and one osteoporotic fracture. In 151 pedicles, screw placement was performed in the CT room. CT images were reviewed regarding accuracy and cortical violations using the popular 2 mm increment deviation classification of Gertzbein and Robbins. RESULTS: Guidewire implantation resulted in only 28 cortical contacts. Minor encroachments of the pedicle wall by inserted screws occurred in 39.1% (59 of 151) and in 23.8% if taking unavoidable encroachments into account (30 of 59). Pedicular isthmus width correlated to cortical guidewire contacts (r=-0.449; p=0.077) and pedicle violations (all graded "A") by the inserted screws (r=-0.581; p=0.049). Total procedural duration was 138.6±44.2 minutes, representing 14.5±11.6 minutes for each pedicle, while showing a significant correlation against higher vertebral levels (r=-0.849; p=0.0002) and the occurrence of pedicle violations (r=-0.641; p=0.027). CONCLUSIONS: The treatment of vertebral fractures with a guidewire-based pedicle screw insertion technique under CT imaging results in very high accuracy and a low complication rate.


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Cuidados Pré-Operatórios/métodos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/cirurgia
4.
Eur J Radiol ; 84(10): 1976-80, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26210096

RESUMO

PURPOSE: The aim of this study was to analyse the radiation dose and quickness of needle interventions using a Laser Navigation System (LNS-group) compared with conventional method (control-group). MATERIALS AND METHODS: In this prospective, randomized, comparative study 58 patients (19 females, 39 males; mean age, 62.9 years) were punctured either with LNS (n=29) or with conventional method with a skin mark of the puncture site (n=29). In the LNS method the puncture site was marked with laser without additional CT. Thoracic and abdominal intervention was performed in 30 and 28 patients, respectively. Radiation dose and time of the procedures were analysed. Statistical significance was calculated according to the Mann-Whitney-U-test. RESULTS: Mean target access path in the patients of the LNS group was 6.0 cm (range, 3.0-10.1cm) and in the control group 6.0 cm (range, 1.0-10.3 cm). Time duration of complete intervention in the LNS group was 20:25 min (range, 07:00-34:00 min) and in the control group 28:00 min (range, 13:00-51:00 min). The dose-length-product (DLP) of intervention scan of the LNS group was 42.3 mGy cm (range, 10-125 mGy cm), and of the control group 59.7 mGy cm (range, 25-176.42 mGy cm). CONCLUSION: Using the LNS for CT-guided interventions results in faster intervention time with a lower dose.


Assuntos
Lasers , Punções/métodos , Doses de Radiação , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Abdome/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Drenagem/métodos , Feminino , Humanos , Biópsia Guiada por Imagem/métodos , Masculino , Pessoa de Meia-Idade , Agulhas , Estudos Prospectivos , Punções/instrumentação , Distribuição Aleatória , Estatísticas não Paramétricas , Tórax/patologia , Fatores de Tempo
5.
Rofo ; 186(10): 937-44, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24729409

RESUMO

PURPOSE: Chemosaturation with percutaneous hepatic perfusion (PHP; Hepatic CHEMOSAT(®) Delivery System; Delcath Systems Inc, USA) is a minimally invasive, repeatable regional therapy for unresectable hepatic metastases. It uses a system of catheters and filters to isolate hepatic venous blood from the systemic circulation, allowing delivery of high-dose chemotherapy to the hepatic artery. Effluent hepatic venous blood is filtered before being returned to the systemic circulation, thereby reducing exposure to chemotherapy. We describe our experiences with chemosaturation-PHP at 2 European centers. MATERIALS AND METHODS: 14 patients presented unresectable hepatic metastases from solid tumors; 13 received 1 - 3 sessions of chemosaturation-PHP. Melphalan 2.0 (n = 1) or 3.0 (n = 12) mg/kg was given as a 30-minute infusion into the hepatic artery. 12 patients were evaluable for tumor response. RESULTS: One complete (cholangiocarcinoma, n = 1) and 6 partial responses (ocular, n = 3 or cutaneous melanoma, n = 3) were observed, 5 patients had stable disease (ocular melanoma, n = 3; breast cancer, n = 1; gastric cancer, n = 1). Mild to moderate filter-related toxicity (i. e. thrombocytopenia, anemia) was observed immediately post-procedure. Grade 3/4 melphalan-related pancytopenia developed after 1 - 2 weeks. All hematological events were managed effectively with transfusions and/or other supportive measures. The new high-efficiency filter showed milder toxicity and faster recovery. In one case, chemosaturation-PHP was abandoned prematurely due to heparin-induced vaginal bleeding, and one patient died due to retroperitoneal hemorrhage from heparin anti-coagulation. CONCLUSION: Chemosaturation-PHP for non-resectable liver metastases is a feasible treatment option when performed by an experienced multi-disciplinary team. It may be a promising regional therapy for patients with no effective treatment options.


Assuntos
Quimioterapia do Câncer por Perfusão Regional/instrumentação , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/secundário , Melfalan/administração & dosagem , Adulto , Idoso , Relação Dose-Resposta a Droga , Desenho de Equipamento , Europa (Continente) , Feminino , Filtração/instrumentação , Seguimentos , Humanos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética , Masculino , Melfalan/efeitos adversos , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X
6.
J Eur Acad Dermatol Venereol ; 28(12): 1756-60, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24593299

RESUMO

PURPOSE: Evaluation of the local tumour control rate and survival data for magnetic resonance (MR) imaging-guided laser ablation of uveal malignant melanoma liver metastases by using laser-induced interstitial thermotherapy (LITT). MATERIALS AND METHODS: The LITT was performed in 18 patients with liver metastases (n = 44) from uveal malignant melanoma. All patients tolerated this intervention well. With the Kaplan-Meier method, the survival rates were calculated. Indications for the procedure were defined for patients with no more than five metastases, none of which were larger than 5 cm in diameter: The Indication for LITT treatment were recurrent liver metastases after partial liver resection (22%), locally non-resectable tumours (17%) or metastases in both liver lobes (61%). RESULTS: The mean survival rate for all treated patients was 3.6 years (95% CI: 2.19, 5.06). We started the calculation on the date of diagnosis of the metastases treated with LITT. The median survival was 1.83 years; 1-year survival, 88%; 3-year survival 47%, 5-year survival 17%. Calculated after the first LITT treatment the median survival was 2.8 years (95% CI: 1.0, 5.0). 10 patients were treated by transarterial chemoembolization before LITT. CONCLUSION: MR-guided LITT treatment shows a high local tumour control and survival rates in patients with liver metastases of uveal malignant melanoma.


Assuntos
Hipertermia Induzida , Neoplasias Hepáticas/secundário , Melanoma/terapia , Neoplasias Uveais/terapia , Adulto , Idoso , Feminino , Humanos , Neoplasias Hepáticas/terapia , Imageamento por Ressonância Magnética , Masculino , Melanoma/patologia , Pessoa de Meia-Idade , Taxa de Sobrevida , Neoplasias Uveais/patologia
7.
Chemotherapy ; 59(1): 66-73, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23839050

RESUMO

BACKGROUND: To define the maximum tolerated dose (MTD) tolerability and efficacy of intra-arterial chemotherapy with irinotecan in patients with liver metastases of colorectal carcinoma (CRC). METHODS: Superselective intra-arterial irinotecan was applied on days 1, 14, 28 and 42. The initial dose was 140 mg/m² with escalation in the subsequent patient group to 160 mg/m². The final protocol toxicity evaluation was 260 mg/m². Patients required histologically proven disease and adequate bone marrow, liver and renal function, no extrahepatic metastasis and a life expectancy >12 weeks. results: Thirty-three patients were enrolled (median age 65, range 49-78 years). On dose level VI (240 mg/m²), 1 case of dose-limiting toxicity (DLT) (granulocytopenia) was observed, leading to an enlarged cohort of 6 patients. As no additional DLT was detected on this level, an escalation to level VII was performed. On the dose level of 260 mg/m², irinotecan DLTs were observed, resulting in the termination of escalation and the declaration of dose level VI as MTD. Imaging follow-up with Response Evaluation Criteria in Solid Tumors (RECIST) criteria revealed a complete response in 1 patient, stable disease in 31 patients, and progressed disease in 1 patient. The median time to progression was 4.7 months, the median overall survival 15.6 months. CONCLUSION: The method of intra-arterial chemotherapy with irinotecan is well tolerated and shows promising local response rates in liver metastases of CRC.


Assuntos
Antineoplásicos Fitogênicos/uso terapêutico , Camptotecina/análogos & derivados , Neoplasias Colorretais/patologia , Neoplasias Hepáticas/tratamento farmacológico , Idoso , Agranulocitose/etiologia , Antineoplásicos Fitogênicos/efeitos adversos , Camptotecina/efeitos adversos , Camptotecina/uso terapêutico , Estudos de Coortes , Relação Dose-Resposta a Droga , Esquema de Medicação , Feminino , Humanos , Injeções Intra-Arteriais , Irinotecano , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Análise de Sobrevida , Tomografia Computadorizada por Raios X
8.
Dtsch Med Wochenschr ; 138(15): 792-8, 2013 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-23549629

RESUMO

AIM AND METHOD: This paper presents the basic techniques and clinical results of the most common hyperthermal ablation methods for patients with malignant liver metastases of colorectal carcinoma. An overview of recently published data is provided using selected articles from the literature and our own clinical experience in an interdisciplinary liver centre. RESULTS: Radiofrequency ablation (RFA), microwave ablation (MWA) and laser ablation (LITT) show comparable results concerning survival data. Local recurrence is less frequent after LITT (7,1-10%) than after RFA (32-44%) and MWA (7-15%). Survival depends on many factors. The 3-year survival rate for RFA ranges from 20,2-71,3%, for MWA it is 51,1% and for LITT from 56-77%. Mean complication rates range from 1,8-10%. Recent studies showed promising results after combined therapy of regional chemotherapy or regional radiotherapy with thermal ablation. CONCLUSION: Ablation methods such as RFA, MWA and LITT show good local tumor control with low complication rates and are usually performed on an outpatient basis. Indications are <5 metastases limited to the liver with a maximum diameter of ≤4 cm when surgical resection is contraindicated or has been previously performed. The decision should be made by an interdisciplinary tumor board.


Assuntos
Ablação por Cateter/tendências , Neoplasias Colorretais/terapia , Terapia a Laser/tendências , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/terapia , Micro-Ondas/uso terapêutico , Recidiva Local de Neoplasia/prevenção & controle , Cauterização/métodos , Humanos , Resultado do Tratamento
9.
Int J Oncol ; 41(4): 1213-20, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22842404

RESUMO

The objective of this pilot clinical study was to assess the safety, technical feasibility, pharmacokinetic (PK) profile and tumour response of DC Bead™ with irinotecan (DEBIRI™) delivered by intra-arterial embolisation for the treatment of metastatic colorectal cancer. Eleven patients with unresectable liver metastases from CRC, tumour burden <30% of liver volume, adequate haematological, liver and renal function, performance status of <2 were included in this study. Patients received up to 4 sessions of TACE with DEBIRI at 3-week intervals. Feasibility of the procedure, safety and tumour response were assessed after each cycle. PK was measured after the first cycle. Patients were followed up to 24 weeks. Only mild to moderate adverse events were observed. DEBIRI is a technically feasibile procedure; no technical complications were observed. Average Cmax for irinotecan and SN-38 was 194 ng/ml and 16.7 ng/ml, respectively, with average t½ of 4.6 h and 12.4 h following administration of DEBIRI. Best overall response during the study showed disease control in 9 patients (2 patients with partial response and 7 with stable disease, overall response rate of 18%). Our study shows that transarterial chemoembolisation with irinotecan-loaded DC beads (DEBIRI) is safe, technically feasible and effective with a good PK profile.


Assuntos
Camptotecina/análogos & derivados , Neoplasias Colorretais/tratamento farmacológico , Sistemas de Liberação de Medicamentos , Neoplasias Hepáticas/tratamento farmacológico , Idoso , Idoso de 80 Anos ou mais , Camptotecina/administração & dosagem , Quimioembolização Terapêutica/métodos , Neoplasias Colorretais/patologia , Feminino , Humanos , Irinotecano , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
10.
Rofo ; 184(10): 883-92, 2012 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-22711249

RESUMO

To present current data on diagnosis, indication and different therapy options in patients with cholangiocarcinoma (CC) based on an analysis of the current literature and clinical experience. The diagnostic routine includes laboratory investigations with parameters of cholestasis and also serum tumor markers CA19 - 9 and CEA. After ultrasound for clarifying a tumor and/or dilated bile ducts, contrast-enhanced magnetic resonance imaging (MRI) should be performed with magnetic resonance cholangiography (MRCP). The accuracy (positive predictive value) for diagnosing a CC is 37-84% (depending on the location) for ultrasound, 79-94% for computed tomography (CT), and 95% for MRI and MRCP. An endoscopic retrograde cholangiography (ERCP) can then be planned, especially if biliary drainage or cytological or histological specimen sampling is intended. A curative approach can be achieved by surgical resection, rarely by liver transplantation. However, many patients are not eligible for surgery. In addition to systemic chemotherapy, locoregional therapies such as transarterial chemoembolization (TACE), hepatic arterial infusion (HAI)--also known as chemoperfusion--, drug eluting beads-therapy (DEB) as well as thermoablative procedures, such as laser-induced thermotherapy (LITT), microwave ablation (MWA) and radiofrequency ablation (RFA) can be provided with a palliative intention.


Assuntos
Neoplasias dos Ductos Biliares/diagnóstico , Neoplasias dos Ductos Biliares/terapia , Ductos Biliares Intra-Hepáticos/patologia , Colangiocarcinoma/diagnóstico , Colangiocarcinoma/terapia , Diagnóstico por Imagem , Neoplasias dos Ductos Biliares/patologia , Biomarcadores Tumorais/sangue , Antígeno CA-19-9/sangue , Antígeno Carcinoembrionário/sangue , Colangiocarcinoma/patologia , Colangiopancreatografia Retrógrada Endoscópica , Colangiopancreatografia por Ressonância Magnética , Terapia Combinada , Meios de Contraste/administração & dosagem , Humanos , Aumento da Imagem , Imageamento por Ressonância Magnética , Prognóstico , Tomografia Computadorizada por Raios X , Ultrassonografia
11.
Br J Cancer ; 106(7): 1274-9, 2012 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-22382689

RESUMO

BACKGROUND: To evaluate a treatment protocol with repeated transarterial-chemoembolisation (TACE) downsizing before MR-guided laser-induced interstitial thermotherapy (LITT) using different chemotherapeutic combinations in patients with unresectable colorectal cancer (CRC) liver metastases. METHODS: Two hundred and twenty-four patients were included in the current study. Transarterial-chemoembolisation (mean 3.4 sessions per patient) was performed as a downsizing treatment to meet the LITT requirements (number5, diameter <5 cm). The intra-arterial protocol consisted of either Irinotecan and Mitomycin (n=77), Gemcitabine and Mitomycin (n=49) or Mitomycin alone (n=98) in addition to Lipiodol and Embocept in all patients. Post TACE, all patients underwent LITT (mean 2.2 sessions per patient). RESULTS: Overall, TACE resulted in a mean reduction in diameter of the target lesions of 21.4%. The median time to progression was 8 months, calculated from the start of therapy and the median local tumour control rate was 7.5 months, calculated as of therapy completion. Median survival of patients calculated from the beginning of TACE was 23 months (range 4-110 months), in patients treated with Irinotecan and Mitomycin the median was 22.5 months, Gemcitabine and Mitomycin 23 months and Mitomycin only 24 months with a statistically significant difference between the groups (P<0.01). CONCLUSION: Repeated TACE offers adequate downsizing of CRC liver metastases to allow further treatment with LITT. The combined treatment illustrates substantial survival rates and high local tumour control with statistically significant differences between the three protocols used. Further randomised trials addressing the current study results are required.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Quimioembolização Terapêutica/métodos , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/patologia , Hipertermia Induzida/métodos , Neoplasias Hepáticas/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Colorretais/terapia , Terapia Combinada , Embolização Terapêutica , Feminino , Humanos , Lasers , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Análise de Sobrevida
12.
Ultrasound Obstet Gynecol ; 40(4): 452-8, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22173924

RESUMO

OBJECTIVES: To study Doppler changes in the uterine artery immediately following and 3 months after uterine artery embolization (UAE) and to test the feasibility of using uterine artery Doppler as a predictor of the predominant side of arterial supply to leiomyomas, amount of embolizing material needed and leiomyoma tumor volume at follow-up. METHODS: The study included 38 patients undergoing UAE for leiomyomas. Uterine artery Doppler was performed transabdominally before, within 6 hours after and 3 months after UAE to determine the peak systolic (PSV) and end-diastolic (EDV) velocities and resistance index (RI). Leiomyoma volume was measured using contrast-enhanced magnetic resonance imaging (MRI) before and 3 months after UAE. The predominant side of arterial supply to the leiomyoma was determined on digital subtraction angiography using the uterine artery diameter and tumor blush after contrast injection. For correlations with leiomyoma volume, the average PSV, EDV and RI of both sides was used, while for prediction of the predominant side of supply and for correlation with the amount of embolizing material needed, separate measurements from each side were used. RESULTS: Relative to the pre-embolization value, the uterine artery PSV and EDV were significantly reduced (P < 0.05) immediately following UAE, while the RI was significantly elevated (P < 0.05). For prediction of the predominant side of supply, the lowest RI showed the highest accuracy (81.6%). There was no significant correlation between the pre-embolization PSV, EDV or RI and the amount of embolizing material utilized. Immediately post-embolization EDV and RI values were statistically significantly correlated with the 3-month follow-up leiomyoma volume, with RI showing the strongest correlation (P = 0.0400 and 0.0002, rho = 0.34 and - 0.58, respectively). The leiomyoma volume was predicted to have reduced by 38-61% after 3 months if the immediate post-embolization average RI value was between 0.82 and 0.88. CONCLUSION: Pre-interventional Doppler assessment can be used to predict the predominant side of supply to leiomyomas but not the amount of embolizing material needed. Immediate post-interventional Doppler assessment can predict the leiomyoma volume after UAE.


Assuntos
Leiomioma/diagnóstico por imagem , Leiomioma/cirurgia , Ultrassonografia Doppler , Embolização da Artéria Uterina , Artéria Uterina/diagnóstico por imagem , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/cirurgia , Adulto , Meios de Contraste , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Resultado do Tratamento , Carga Tumoral
13.
Rofo ; 184(1): 42-7, 2012 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-22033845

RESUMO

PURPOSE: The purpose of this study was to examine the clinical use of MR-guided biopsies in patients with suspicious lesions using a new MR-compatible assistance system in a high-field MR system. MATERIALS AND METHODS: Six patients with suspicious focal lesions in various anatomic regions underwent percutanous biopsy in a high-field MR system (1.5 T, Magnetom Espree, Siemens) using a new MR-compatible assistance system (Innomotion). The procedures were planned and guided using T 1-weighted FLASH and TrueFISP sequences. A servopneumatic drive then moved the guiding arm automatically to the insertion point. An MRI compatible 15G biopsy system (Somatex) was introduced by a physician guided by the needle holder and multiple biopsies were performed using the coaxial technique. The feasibility, duration of the intervention and biopsy findings were analyzed. RESULTS: The proposed new system allows accurate punctures in a high-field MR system. The assistance device did not interfere with the image quality, and guided the needle virtually exactly as planned. Histological examination could be conducted on every patient. The lesion was malignant in four cases, and an infectious etiology was diagnosed for the two remaining lesions. Regarding the differentiation of anatomical and pathological structures and position monitoring of the insertion needle, TrueFISP images are to be given preference. The average intervention time was 41 minutes. Lesions up to 15.4 cm beneath the skin surface were punctured. CONCLUSION: The proposed MR-guided assistance system can be successfully utilized in a high-field MR system for accurate punctures of even deep lesions in various anatomic regions.


Assuntos
Biópsia por Agulha/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Robótica/instrumentação , Adulto , Idoso , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Software
14.
J Bone Oncol ; 1(2): 63-6, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26909257

RESUMO

BACKGROUND: Radiofrequency ablation is a minimal invasive therapy in the treatment of bone metastases. In this study we present a new ablation system enabling an ablation in multiple directions and with an adaptable size and shape. MATERIAL AND METHODS: VX-2 tumor was used for the induction of experimental bone metastases in the femur of six New Zealand white rabbits. X-ray imaging as well as CT and MRI scans before and after treatment was carried out. After detecting bone tumor, radiofrequency ablation was performed. The ablation instrument contained a 10 g bipolar, articulated extendable electrode and a proprietary generator with an impedance controlled algorithm. All bones and the soft tissue were examined histologically. RESULTS: All animals developed local bone tumor. Mean duration until first osteolytic lesions on CT-scans was 48±14 days. The mean lesion area was 26 mm(2). No systemic tumor spread was seen. 6 radiofrequency procedures were carried out with a mean application time of 6 min±2:30 and an average temperature in the region of effect of 55 °C±4. MRI imaging demonstrated an ablation zone of 23±6 mm around the electrode. Histopathology showed an extensive heat necrosis with no remaining tumor cells in the ablation area. CONCLUSION: Radiofrequency ablation is a quickly developing treatment option on the field of minimal invasive bone tumor therapy. The electrode enables an ablation adapted to size and shape of the metastases. Further clinical studies are necessary to test and enhance this radiofrequency system.

15.
Eur Surg Res ; 47(3): 154-8, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21952266

RESUMO

BACKGROUND: Animal bone models are inevitable for musculoskeletal research. The induction of a local bone tumor is complex and time consuming. In this study a new model is presented using a direct implantation of tumor cells into the bone without a preliminary passaging of the cells. METHODS: A three-dimensional matrix consisting of alginate spheroids and carrying the VX-2 tumor suspension was used for implantation into the bone of 6 female New Zealand white rabbits. X-ray imaging, CT and MRI scans as well as a histological examination were carried out. RESULTS: All rabbits developed local bone tumor in the metaphysis of the femoral leg. Bone tumor was identifiable on average 6.2 weeks after implantation. Fluoroscopy, CT and MRI scans showed a cortical reaction but no destruction of the compact bone together with a mean tumor size of 14 mm. Histological examination revealed a tumor infiltration with an activation of osteoclasts and an osteoclastic resorption. CONCLUSION: The direct implantation of a VX-2 tumor suspension into the rabbit bone using alginate spheroids is an effective and reproducible way to successfully induce bone tumor. This new animal model allows further examination of surgical and minimal invasive therapy in musculoskeletal research.


Assuntos
Neoplasias Ósseas/patologia , Esferoides Celulares/patologia , Alginatos , Animais , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/cirurgia , Linhagem Celular Tumoral , Modelos Animais de Doenças , Feminino , Ácido Glucurônico , Ácidos Hexurônicos , Imageamento por Ressonância Magnética , Transplante de Neoplasias , Coelhos , Esferoides Celulares/diagnóstico por imagem , Alicerces Teciduais , Tomografia Computadorizada por Raios X
16.
Rofo ; 183(1): 12-23, 2011 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-21113865

RESUMO

Presentation of techniques and procedures for regional chemotherapy in the treatment of unresectable liver metastases from different primary tumors as a modality of interdisciplinary therapy management. Such transarterial therapy methods include hepatic arterial infusion (HAI), transarterial chemoembolization (TACE), chemoembolization with cytostatic-loaded microspheres (DEBs), transarterial embolization (TAE) and selective internal radiation therapy (SIRT). Regional chemotherapy procedures in the treatment of liver metastases represent a minimally invasive treatment option that can be successfully combined with surgical resection and/or radiofrequency (RFA), laser-induced thermotherapy (LITT), microwave ablation (MWA). These procedures allow optimization of the local control rate with strictly intrahepatic processes and lead to increased survival rates without any quality of life restriction.


Assuntos
Quimioembolização Terapêutica/métodos , Embolização Terapêutica/métodos , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/terapia , Neoplasias da Mama/patologia , Terapia Combinada , Neoplasias das Glândulas Endócrinas/patologia , Feminino , Artéria Hepática , Humanos , Infusões Intra-Arteriais/métodos , Injeções Intra-Arteriais , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/radioterapia , Pessoa de Meia-Idade , Radioterapia/métodos
17.
Rofo ; 182(11): 947-53, 2010 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-20725875

RESUMO

In recent years MR imaging has played an increasingly important role in the diagnosis and treatment of prostate cancer. MR imaging of the prostate allows clear delineation of the anatomic structures and prostate tumors using T 2-weighted images combined with spectroscopy and dynamic examinations. The advantages of MRI make it possible to perform interventions, like biopsies, brachytherapy or different local therapies of the prostate gland. MRI robotic assistance will improve the accuracy of the interventions. Due to the advantages of MR imaging, MR-guided prostate interventions will play a greater role in the future.


Assuntos
Braquiterapia/instrumentação , Imagem por Ressonância Magnética Intervencionista/instrumentação , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Neoplasias da Próstata/terapia , Robótica/instrumentação , Ressecção Transuretral da Próstata/instrumentação , Adulto , Idoso , Biomarcadores Tumorais/sangue , Biópsia por Agulha/instrumentação , Meios de Contraste/administração & dosagem , Meios de Contraste/farmacocinética , Diagnóstico Precoce , Desenho de Equipamento , Humanos , Espectroscopia de Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Antígeno Prostático Específico/sangue , Sensibilidade e Especificidade , Adulto Jovem
18.
Rofo ; 181(7): 658-63, 2009 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-19517340

RESUMO

PURPOSE: The purpose of this study was to evaluate the safety and clinical value of MR-guided biopsies in an open 0.2 T low-field system. MATERIALS AND METHODS: A total of 322 patients with suspicious lesions of different body regions were biopsied in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T 1-weighted Flash sequences (TR/TE = 100/9; 70 degrees). The lesions were repeatedly biopsied using the coaxial technique with a 15-gauge (diameter 2 mm) puncture needle. Complications and biopsy findings were analyzed retrospectively. RESULTS: In all cases the biopsy procedures were successfully performed with MR guidance. In 298 patients diagnosis was able to be confirmed on the basis of the probes. The clinical follow-up showed that in 24 patients the lesions were missed by MR-guided biopsy. From this a sensitivity of 86%, a specificity of 87% and an accuracy of 93% were calculated. In two patients major complications were observed (morbidity rate 0.6 %). CONCLUSION: MR-guided biopsy can be performed safely and precisely in a low-field MR system and are a supplement to US or CT-guided biopsies.


Assuntos
Biópsia por Agulha/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Neoplasias/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
19.
Dtsch Med Wochenschr ; 134(19): 1011-4, 2009 May.
Artigo em Alemão | MEDLINE | ID: mdl-19401971

RESUMO

Magnetic resonance imaging (MRI) in combination with magnetic resonance cholangiopancreatography (MRCP) is an integrated part in the diagnosis of bile-duct diseases and requires a standaridized complex examination technique. Radiologic and gastroenterologic indications are the diagnosis of anomalies, concrements, chronic inflammations and tumor diagnosis, especially of cholangiocarinoma such as Klatskin tumor and pancreatic cancer. MRCP is integrated in the preinterventional concept for performing invasive endoscopic retrograde cholangiopancreatography (ERCP) and for follow-up post intervention and for diagnosing complications.


Assuntos
Doenças Biliares/diagnóstico , Colangiopancreatografia por Ressonância Magnética , Pancreatopatias/diagnóstico , Humanos
20.
Eur J Obstet Gynecol Reprod Biol ; 137(2): 204-9, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17397990

RESUMO

OBJECTIVE: Enlargement of the junctional zone (JZ) on T2-weighted resonance imaging of the uterus has recently been established as the major criterion for adenomyosis in patients with endometriosis. This study was conducted to analyse the extent of adenomyosis using magnetic resonance imaging (MRI) and relate it to the duration of dysmenorrhoea. STUDY DESIGN: This was a prospective study of 70 patients presenting with the complaint of severe dysmenorrhoea. Forty patients (57%) reported dysmenorrhoea as their major complaint and 30 patients (43%) suffered additionally from infertility. Group I (n=40) consisted of patients with dysmenorrhoea of between 1 and 10 years' duration, group II (n=30) consisted of patients with dysmenorrhoea of longer than 11 years' duration. All patients underwent laparoscopy to detect the presence and degree of endometriosis, and all patients underwent T2-weighted resonance imaging of the uterus to detect the extent of adenomyosis by measurement of the "junctional zone". RESULTS: In group I, adenomyosis could be detected via MRI in 21 patients (52.5%), while 19 patients (47.5%) showed no signs of adenomyosis. By contrast, in group II a distinct enlargement of the JZ, as the major radiological criterion of adenomyosis, could be observed in 26 patients (87%), while only 4 patients (13%) revealed no signs of adenomyosis (p=0.04). The mean thickness of the JZ was significantly enlarged in group II (11.07 mm) compared with group I (6.38 mm; p<0.0001). The prevalence of adenomyosis in endometriosis after dysmenorrhoea of more than 11 years' duration was 87%. CONCLUSIONS: In deep infiltrating endometriosis, a correlation between a specific localisation and dysmenorrhoea can often not be found. Recently, endometriosis and adenomyosis have been believed to result from a common uterine disease, the dislocation of the basal endometrium. Our data clearly show that dysmenorrhoea of long duration in patients who have had endometriosis for over a threshold value of 11 years is significantly related to adenomyosis of the uterus. Hence, evaluation of adenomyosis using MRI should become a standard procedure in cases of dysmenorrhoea and endometriosis. Severe dysmenorrhoea of long duration should always focus clinical interest on adenomyosis of the uterus.


Assuntos
Dismenorreia/patologia , Endometriose/patologia , Imageamento por Ressonância Magnética , Adulto , Progressão da Doença , Dismenorreia/diagnóstico , Dismenorreia/etiologia , Endometriose/complicações , Endometriose/diagnóstico , Endométrio/patologia , Feminino , Humanos , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA