Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Biomech ; 168: 112110, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38677025

RESUMO

Rotator cuff (RC) tears are a common source of pain and decreased shoulder strength. Muscle length is known to affect muscle strength, and therefore evaluating changes in supraspinatus muscle length associated with RC pathology, surgical repair, and post-operative recovery may provide insights into functional deficits. Our objective was to develop a reliable MRI-based approach for assessing supraspinatus muscle length. Using a new semi-automated approach for identifying 3D location of the muscle-tendon junction (MTJ), supraspinatus muscle length was calculated as the sum of MTJ distance (distance between 3D MTJ position and glenoid plane) and supraspinatus fossa length (distance between root of the scapular spine and glenoid plane). Inter- and intra-operator reliability of this technique were assessed with intraclass correlation coefficient (ICC) and found to be excellent (ICCs > 0.96). Muscle lengths of 6 patients were determined before RC repair surgery and at 3- and 12-months post-surgery. Changes in normalized muscle length (muscle length as a percentage of pre-surgical muscle length) at 3 months post-surgery varied considerably across patients (16.1 % increase to 7.0 % decrease) but decreased in all patients from 3- to 12-months post-surgery (0.3 % to 17.2 %). This study developed a novel and reliable approach for quantifying supraspinatus muscle length and provided preliminary demonstration of its utility by assessing muscle length changes associated with RC pathology and surgical repair. Future studies can use this technique to evaluate changes over time in supraspinatus muscle length in response to clinical intervention, and associations between muscle length and shoulder function.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Lesões do Manguito Rotador , Manguito Rotador , Humanos , Imageamento por Ressonância Magnética/métodos , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Manguito Rotador/fisiologia , Masculino , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/fisiopatologia , Pessoa de Meia-Idade , Feminino , Imageamento Tridimensional/métodos , Idoso , Adulto , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Reprodutibilidade dos Testes
2.
Orthop J Sports Med ; 10(3): 23259671221084294, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35387360

RESUMO

Background: Rotator cuff repair is a common orthopaedic procedure that provides pain relief for many patients, but unfortunately, an estimated 20% to 70% of repair procedures will fail. Previous research has shown that elongation (ie, retraction) of a repaired tendon is common even in patients with a repair construct that appears intact on magnetic resonance imaging. However, it is unknown how this repair tissue functions under dynamic conditions. Purpose: To quantify static retraction and maximum dynamic elongation of repair tissue after rotator cuff repair. Study Design: Case series; Level of evidence, 4. Methods: Data from 9 patients were analyzed for this study. During surgery, a 3.1-mm tantalum bead was sutured to the supraspinatus tendon, medial to the repair site. Glenohumeral kinematics were assessed at 1 week (static) and 3 months (static and during scapular-plane abduction) after surgery using a biplanar videoradiographic system. The 3-dimensional position of the bead was calculated relative to the tendon's insertion on the humerus (ie, bead-to-insertion distance). Static retraction was calculated as the change in the bead-to-insertion distance under static conditions between 1 week and 3 months after surgery, and maximum dynamic elongation was calculated as the maximal positive change in the bead-to-insertion distance during dynamic motion relative to the start of motion. The magnitudes of static retraction and maximum dynamic elongation were assessed with 1-sample t tests. Results: At 3 months after surgery, static retraction occurred in all patients by a mean of 10.0 ± 9.1 mm (P = .01 compared with no elongation). During scapular-plane abduction, maximum dynamic elongation averaged 1.4 ± 1.0 mm (P < .01 compared with no elongation). Descriptively, dynamic elongation consistently took 1 of 2 forms: an initial increase in the bead-to-insertion distance (mean, 2.0 ± 0.6 mm) before decreasing until the end of motion or an immediate and substantial decrease in the bead-to-insertion distance at the onset of motion. Conclusion: Repair tissue elongation (static retraction and maximum dynamic elongation) appeared to be a common and significant finding at 3 months after arthroscopic rotator cuff repair. Dynamic elongation of repair tissue during scapular-plane abduction exhibited 1 of 2 distinct patterns, which may suggest different patterns of supraspinatus mechanical and neuromuscular function.

3.
J Orthop Res ; 40(4): 917-924, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34191325

RESUMO

Repair tissue healing after rotator cuff repair remains a significant clinical problem, and excessive shoulder activity after surgical repair is believed to contribute to re-tears. In contrast, small animal studies have demonstrated that complete removal of activity impairs tendon healing and have advocated for an "appropriate" level of activity, but in humans the appropriate amount of shoulder activity to enhance healing is not known. As an initial step toward understanding the relationship between postoperative shoulder activity and repair tissue healing, the objectives of this study were to assess the precision, accuracy, and feasibility of a wrist-worn triaxial accelerometer for measuring shoulder activity. Following assessments of precision (±0.002 g) and accuracy (±0.006 g), feasibility was assessed by measuring 1 week of shoulder activity in 14 rotator cuff repair patients and 8 control subjects. Shoulder activity was reported in terms of volume (mean acceleration, activity count, mean activity index, active time) and intensity (intensity gradient). Patients had significantly less volume (p ≤ .03) and intensity (p = .01) than controls. Time post-surgery was significantly associated with the volume (p ≤ .05 for mean acceleration, activity count, and mean activity index) and intensity (p = .03) of shoulder activity, but not active time (p = .08). These findings indicate this approach has the accuracy and precision necessary to continuously monitor shoulder activity with a wrist-worn sensor. The preliminary data demonstrate the ability to discriminate between healthy control subjects and patients recovering from rotator cuff repair and provide support for using a wearable sensor to monitor changes over time in shoulder activity.


Assuntos
Lesões do Manguito Rotador , Ombro , Animais , Artroscopia/métodos , Humanos , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Ombro/cirurgia , Resultado do Tratamento
4.
J Shoulder Elbow Surg ; 26(6): 1064-1072, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28131679

RESUMO

BACKGROUND: The incidence of asymptomatic rotator cuff tears has been reported to range from 15% to 39%, but the influence of asymptomatic rotator cuff pathology on shoulder function is not well understood. This study assessed the effects of asymptomatic rotator cuff pathology on shoulder kinematics, strength, and patient-reported outcomes. METHODS: A clinical ultrasound examination was performed in 46 asymptomatic volunteers (age: 60.3 ± 7.5 years) with normal shoulder function to document the condition of their rotator cuff. The ultrasound imaging identified the participants as healthy (n = 14) or pathologic (n = 32). Shoulder motion was measured with a biplane x-ray imaging system, strength was assessed with a Biodex (Biodex Medical Systems, Inc., Shirley, NY, USA), and patient-reported outcomes were assessed using the Western Ontario Rotator Cuff Index and visual analog scale pain scores. RESULTS: Compared with healthy volunteers, those with rotator cuff pathology had significantly less abduction (P = .050) and elevation (P = .041) strength, their humerus was positioned more inferiorly on the glenoid (P = .018), and the glenohumeral contact path length was longer (P = .007). No significant differences were detected in the Western Ontario Rotator Cuff Index, visual analog scale, range of motion, or acromiohumeral distance. CONCLUSIONS: The differences observed between the healthy volunteers and those with asymptomatic rotator cuff pathology lend insight into the changes in joint mechanics, shoulder strength, and conventional clinical outcomes associated with the early stages of rotator cuff pathology. Furthermore, these findings suggest a plausible mechanical progression of kinematic and strength changes associated with the development of rotator cuff pathology.


Assuntos
Doenças Assintomáticas , Força Muscular/fisiologia , Amplitude de Movimento Articular/fisiologia , Lesões do Manguito Rotador/diagnóstico , Manguito Rotador/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Imageamento Tridimensional , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Manguito Rotador/fisiopatologia , Lesões do Manguito Rotador/epidemiologia , Lesões do Manguito Rotador/fisiopatologia , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Ultrassonografia , Estados Unidos/epidemiologia
5.
J Shoulder Elbow Surg ; 24(7): 1014-20, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25958216

RESUMO

BACKGROUND: Traumatic glenohumeral joint (GHJ) dislocations are common, resulting in significant shoulder disability and pain. Previous research indicates that bony morphology is associated with an increased risk of injury in other joints (eg, the knee), but the extent to which bony morphology is associated with traumatic GHJ dislocation is unknown. This study assessed GHJ morphology in patients with anterior GHJ instability and in a control population of healthy volunteers. METHODS: Bilateral computed tomography scans were used to measure GHJ morphology in both shoulders of 11 patients with instability and 11 control subjects. Specific outcome measures included the glenoid radius of curvature (ROC) in the anterior/posterior (A/P) and superior/inferior (S/I) directions, humeral head ROC, A/P and S/I conformity index, and A/P and S/I stability angle. RESULTS: Compared with the control subjects, the glenoid of the instability the injured shoulder in patients with instability was flatter (ie, higher ROC) in the A/P (P = .001) and S/I (P = .01) directions and this finding was also true for uninjured, contralateral shoulder (A/P: P = .01, S/I: P = .03). No differences in GHJ morphology were detected between the instability patients' injured and contralateral shoulders (P > .07). Similarly, no differences in GHJ morphology were detected between the control subjects' dominant and nondominant shoulders (P > .51). CONCLUSIONS: There are significant differences in GHJ morphology between healthy control subjects and both shoulders (injured and uninjured, contralateral) of patients diagnosed with anterior instability after GHJ dislocation. These findings are important clinically because they suggest that glenoid morphology may influence the risk of GHJ dislocation.


Assuntos
Instabilidade Articular/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Voluntários Saudáveis , Humanos , Imageamento Tridimensional , Instabilidade Articular/fisiopatologia , Masculino , Estudos Retrospectivos , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/fisiopatologia , Lesões do Ombro , Articulação do Ombro/fisiologia , Tomografia Computadorizada por Raios X , Adulto Jovem
6.
Bone ; 48(3): 663-6, 2011 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-21081188

RESUMO

Using a finite element (FE) method called biomechanical stereology, Wang et al. previously reported increased microcrack formation and propagation in bone samples from patients with a history of osteoporotic fracture as compared to normal subjects. In this study, we re-analyzed the data from Wang's report to determine the microscopic differences between bone tissue from osteoporotic patients and normal subjects that caused these different patterns of bone tissue damage between the groups. The morphological features examined were the number of "voids" (or osteocyte lacunae) visible and the distance of the lacunae from the initiation of the microcracks. We found that bone samples from patients with a history of osteoporotic fracture contained significantly more lacunae than normal control specimens. We also found a significant correlation (r² = 0.483, p = 0.001) between the number of lacunae visible in the image and the number of microcracks formed. These results help to explain the differences in total microcrack number between the osteoporotic and normal subjects reported in our previous work.


Assuntos
Osso e Ossos/patologia , Osteoporose/patologia , Fenômenos Biomecânicos/fisiologia , Biópsia , Osso e Ossos/fisiopatologia , Análise de Elementos Finitos , Humanos , Modelos Biológicos , Osteoporose/fisiopatologia , Estatísticas não Paramétricas , Estresse Mecânico
7.
J Shoulder Elbow Surg ; 18(2): 231-6, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19062313

RESUMO

Glenoid inclination has been associated with rotator cuff tears and superior humeral translation, but the relationship between glenoid inclination and superior humeral translation has not been assessed in vivo. This study compared glenoid inclination between repaired and contralateral shoulders in 21 unilateral rotator cuff repair patients. As a secondary analysis, we assessed the relationship between glenoid inclination and in vivo superior humeral translation. Glenoid inclination was measured from patient-specific, computed tomography-based bone models. Glenohumeral joint motion was measured from biplane radiographs collected during coronal-plane abductions. Glenoid inclination was significantly lower for the rotator cuff tear shoulders (90.7 degrees ) than the asymptomatic, contralateral shoulders (92.3 degrees , P = .04). No significant correlation existed between increased glenoid inclination and superior-inferior translation of the uninjured shoulder (P > .30). This study failed to support the theory that glenoid inclination is responsible for superior humeral translation and the development of subacromial impingement.


Assuntos
Instabilidade Articular/etiologia , Lesões do Manguito Rotador , Escápula/anatomia & histologia , Articulação do Ombro/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Escápula/diagnóstico por imagem , Tomografia Computadorizada por Raios X
8.
J Orthop Surg Res ; 3: 38, 2008 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-18771582

RESUMO

BACKGROUND: Accurately measuring in-vivo motion of the knee's patellofemoral (PF) joint is challenging. Conventional measurement techniques have largely been unable to accurately measure three-dimensional, in-vivo motion of the patella during dynamic activities. The purpose of this study was to assess the accuracy of a new model-based technique for measuring PF joint motion. METHODS: To assess the accuracy of this technique, we implanted tantalum beads into the femur and patella of three cadaveric knee specimens and then recorded dynamic biplane radiographic images while manually flexing and extending the specimen. The position of the femur and patella were measured from the biplane images using both the model-based tracking system and a validated dynamic radiostereometric analysis (RSA) technique. Model-based tracking was compared to dynamic RSA by computing measures of bias, precision, and overall dynamic accuracy of four clinically-relevant kinematic parameters (patellar shift, flexion, tilt, and rotation). RESULTS: The model-based tracking technique results were in excellent agreement with the RSA technique. Overall dynamic accuracy indicated errors of less than 0.395 mm for patellar shift, 0.875 degrees for flexion, 0.863 degrees for tilt, and 0.877 degrees for rotation. CONCLUSION: This model-based tracking technique is a non-invasive method for accurately measuring dynamic PF joint motion under in-vivo conditions. The technique is sufficiently accurate in measuring clinically relevant changes in PF joint motion following conservative or surgical treatment.

9.
Bone ; 42(6): 1184-92, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18378204

RESUMO

Biomechanical stereology is proposed as a two-dimensional (2D) finite element (FE) method to estimate the ability of bone tissue to sustain damage and to separate patients with osteoporotic fracture from normal controls. Briefly, 2D nonlinear compact tension FE models were created from quantitative back scattered electron images taken of iliac crest bone specimens collected from the individuals with or without osteoporotic fracture history. The effects of bone mineral microstructure on predicted bone fracture toughness and microcrack propagation were examined. The 2D FE models were used as surrogates for the real bone tissues. The calculated microcrack propagation results and bone mechanical properties were examined as surrogates for measurements from mechanical testing of actual specimens. The results for the 2D FE simulation separated patients with osteoporotic fracture from normal controls even though only the variability in tissue mineral microstructure was used to build the models. The models were deliberately created to ignore all differences in mean mineralization. Hence, the current results support the following hypotheses: (1) that material heterogeneity is important to the separation of patients with osteoporotic fracture from normal controls; and (2) that 2D nonlinear finite element modeling can produce surrogate mechanical parameters that separate patients with fracture from normal controls.


Assuntos
Fenômenos Biomecânicos/métodos , Osso e Ossos/anatomia & histologia , Análise de Elementos Finitos , Fraturas Ósseas/patologia , Osteoporose/patologia , Biópsia , Força Compressiva , Humanos , Modelos Biológicos , Curva ROC , Estresse Mecânico
10.
Clin Biomech (Bristol, Avon) ; 22(7): 767-73, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17560699

RESUMO

BACKGROUND: The shoulder's subacromial space is of significant clinical interest due to its association with rotator cuff disease. Previous studies have estimated the subacromial space width to be 2-17 mm, but no study has measured in vivo subacromial space width during shoulder motion. The purpose of this study was to measure the in vivo subacromial space width during shoulder elevation in patients following rotator cuff repair. METHODS: Biplane X-ray images were collected during shoulder elevation of 11 patients who had undergone rotator cuff repair. Glenohumeral joint motion was measured from the biplane X-ray images for each subject's repaired and asymptomatic, contralateral shoulders. The joint motion data were combined with subject-specific CT models to measure the subacromial space width during shoulder motion. FINDINGS: Subacromial space width decreased with shoulder elevation, ranging from 2.3 to 7.4 mm in the repaired shoulder and 1.2-7.1 mm in the contralateral shoulder. Subacromial space width in the repaired shoulder was only 0.5 mm less than the contralateral shoulder when averaged over 10-60 degrees of glenohumeral elevation. INTERPRETATION: The results indicate that the humerus in the repaired shoulder is positioned more cranially on the glenoid than in the contralateral shoulder. It is unclear if these subtle differences in subacromial space width are due to the surgical procedure or post-operative stiffness, or if subacromial impingement contributed to the development of the rotator cuff tear. Future research will ascertain if these results represent a transient response to the surgery or a more fundamental difference in rotator cuff function between repaired and contralateral shoulders.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Amplitude de Movimento Articular , Lesões do Manguito Rotador , Manguito Rotador/fisiopatologia , Síndrome de Colisão do Ombro/cirurgia , Lesões do Ombro , Articulação do Ombro/fisiopatologia , Acrômio , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Exame Físico/métodos , Projetos Piloto , Recuperação de Função Fisiológica , Manguito Rotador/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA