RESUMO
OBJECTIVE: To examine the effectiveness of a recently developed nonthermal technology, nanosecond pulse-field ablation (nsPFA), for surgical ablation of the atria in a beating heart porcine model. METHODS: Six pigs underwent sternotomy and ablation using an nsPFA parallel clamp. The ablation electrodes (53 mm long) were embedded in the jaws of the clamp. Nine lesions per pig were created in locations chosen to be representative of the Cox-maze procedure. Four lesions were intended to electrically isolate parts of the atrium: the right atrial appendage, left atrial appendage, right pulmonary veins, and left pulmonary veins. For these lesions, exit block testing was performed both after ablation and before euthanasia; the time between the 2 tests was 3.3 ± 0.5 hours (range, 2-4 hours). Using purse string sutures, 5 more lesions were created up to the superior vena cava, down to the inferior vena cava, across the right atrial free wall, and at 2 distinct locations on the left atrial free wall. The clamp delivered a train of nanosecond duration pulses, with a total duration of 2.5 seconds, independent of tissue thickness. The heart tissue was stained with 1% triphenyltetrazolium chloride after a dwelling period of 2 hours. Subsequently, each lesion was cross sectioned at 5-mm intervals to assess the ablation depth and transmurality. In some sections, transmurality could not be established on the basis of triphenyltetrazolium chloride staining alone; for these lesions, Gomori-trichrome stains were used, and the histologic sections were evaluated for transmurality. RESULTS: The ablation time was 2.5 seconds per lesion, for a total of only 22.5 seconds ablation time to create 9 lesions. A total of 53 lesions were created, resulting in 388 separate histologic sections. Transmurality was established in 386 sections (99.5%). Mean tissue thickness was 3.1 ± 1.5 mm (range, 0.2-8.6 mm). Exit block was confirmed in 23 of the 24 lesions (96%) postablation and 23 of 24 (96%) before the animals were humanely killed. Over the course of the procedure, neither pulse-induced arrhythmias nor any other complications were noted. CONCLUSIONS: The novel nsPFA clamp device was effective in creating acute conduction block and transmural lesions in both the right and left atria in an acute porcine model. This nonthermal energy source has great potential to both shorten procedural time and enable effective ablation in the beating heart.
RESUMO
OBJECTIVE: A right minithoracotomy (RMT) is a minimally invasive surgical approach that has been increasingly performed for the concomitant Cox maze IV procedure (CMP) and mitral valve surgery (MVS). Little is known regarding whether long-term rhythm and survival outcomes are affected by the RMT as compared with the traditional median sternotomy (MS) approach. METHODS: Between April 2004 and April 2021, 377 patients underwent the concomitant CMP and MVS, of whom 38% had RMT. Propensity score matching yielded 116 pairs. Freedom from atrial tachyarrhythmias (ATA) was assessed with prolonged monitoring annually for 8 years. Survival, rhythm, and perioperative outcomes were compared. RESULTS: The unmatched RMT cohort had a greater freedom from ATA recurrence at 1 year (99% vs 90%, P = 0.001) and 3 years (94% vs 86%, P = 0.045). The matched RMT cohort had longer cardiopulmonary bypass (median: 215 [199 to 253] vs 170 [136 to 198] min, P < 0.001) and aortic cross-clamp (110 [98 to 124] vs 86 [71 to 102] min, P < 0.001) times but shorter intensive care time (48 [24 to 95] vs 71 [26 to 144] h, P = 0.001) and length of stay (8 [6 to 11] vs 10 [7 to 14] h, P < 0.001). More pacemakers (18% vs 4%, P < 0.001) and postoperative transfusions (57% vs 41%, P = 0.014) occurred in the MS cohort. The 30-day mortality (P = 0.651) and 8-year survival (P = 0.072) was not significantly different between the cohorts. CONCLUSIONS: Early 1-year and 3-year freedom from ATA recurrence was better in the RMT cohort compared with the MS cohort. Despite longer operative times, the RMT cohort had shorter lengths of stay, fewer postoperative transfusions, and fewer pacemakers placed.
Assuntos
Valva Mitral , Esternotomia , Humanos , Esternotomia/métodos , Valva Mitral/cirurgia , Procedimento do Labirinto , Resultado do Tratamento , Estudos Retrospectivos , Procedimentos Cirúrgicos Minimamente Invasivos/métodosRESUMO
Objective: To develop a minimally invasive, reproducible model of chronic severe mitral regurgitation (MR) that replicates the clinical phenotype of left atrial (LA) and left ventricular dilation and susceptibility to atrial fibrillation. Methods: Under transesophageal echocardiographic guidance, chordae tendinae were avulsed using endovascular forceps until the ratio of regurgitant jet area to LA area was ≥70%. Animals survived for an average of 8.6 ± 1.6 months (standard deviation) and imaged with monthly transthoracic echocardiography (TTE). Animals underwent baseline and preterminal magnetic resonance imaging. Terminal studies included TTE, transesophageal echocardiography, and rapid atrial pacing to test inducibility of atrial tachyarrhythmias. Results: Eight dogs underwent creation of severe MR and interval monitoring. Two were excluded-one died from acute heart failure, and the other had resolution of MR. Six dogs underwent the full experimental protocol; only one required medical management of clinical heart failure. MR remained severe over time, with a mean terminal regurgitant jet area to LA area of 71 ± 14% (standard deviation) and regurgitant fraction of 52 ± 11%. Mean LA volume increased over 130% (TTE: 163 ± 147%, P = .039; magnetic resonance imaging: 132 ± 54%, P = .011). Mean left ventricular end-diastolic volume increased by 38 ± 21% (P = .008). Inducible atrial tachyarrhythmias were seen in 4 of 6 animals at terminal surgery, and none at baseline. Conclusions: Within the 6 dogs that successfully completed the full experimental protocol, this model replicated the clinical phenotype of severe MR, which led to marked structural and electrophysiologic cardiac remodeling. This model allowed for precise measurements at repeated time points and will facilitate future studies to elucidate the mechanisms of atrial and ventricular remodeling secondary to MR and the pathophysiology of valvular atrial fibrillation.
RESUMO
BACKGROUND: Bipolar radiofrequency (RF) clamps are commonly used during surgical ablation for atrial fibrillation (AF). This study examined the efficacy of an irrigated bipolar RF clamp to create transmural lesions in an ex vivo human heart model. METHODS: Ten donor hearts, turned down for transplantation, were explanted and arrested with cold cardioplegia. The ablations of the Cox Maze IV procedure were performed using the Cardioblate LP (Medtronic, Inc) irrigated bipolar RF clamp. In the first 5 hearts, each lesion was created with a single application of RF, whereas in the remaining 5 hearts, each lesion was created with a double application of RF without unclamping. Each lesion was cross-sectioned and stained with 2,3,5-triphenyl-tetrazolium chloride to assess ablation depth and transmurality. RESULTS: A total of 100 lesions were analyzed. In the single-ablation group, 222 of 260 sections (85%) and 37 of 50 lesions (74%) were transmural. The efficacy improved significantly in the double-ablation group, in which 348 of 359 sections (97%, P < .001) and 46 of 50 lesions (92%, P = .017) were transmural. Overall, in nontransmural lesions, the epicardial fat thickness was significantly greater (1.69 ± 0.70 mm vs 0.45 ±0.10 mm, P < .001) than the transmural lesions. CONCLUSIONS: A single ablation on human atrial tissue with an irrigated bipolar RF clamp was insufficient to reliably create transmural lesions, but a double ablation significantly increased the lesion and section transmurality. Nontransmural lesions were associated with significantly thicker layers of epicardial fat, which likely decreased tissue energy delivery due to the higher resistance of fat to current flow.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Transplante de Coração , Ablação por Radiofrequência , Humanos , Ablação por Cateter/métodos , Doadores de Tecidos , Átrios do Coração/cirurgia , Fibrilação Atrial/cirurgiaRESUMO
Objectives: The mechanism by which mitral valve (MV) disease leads to atrial fibrillation (AF) remains poorly understood. Delayed-enhancement cardiac magnetic resonance imaging (DE-MRI) has been used to assess left atrial (LA) fibrosis in patients with lone AF before catheter ablation; however, few studies have used DE-MRI to assess MV-induced LA fibrosis in patients with or without AF undergoing MV surgery. Methods: Between March 2018 and September 2022, 38 subjects were enrolled; 15 age-matched controls, 14 patients with lone mitral regurgitation (MR), and 9 patients with MR and AF (MR + AF). Indexed LA volume, total LA wall, and regional LA posterior wall (LAPW) enhancement were defined by the DE-MRI. One-way analysis of variance was performed. Results: LA volume and LA enhancement were associated (r = 0.451, P = .004). LA volume differed significantly between controls (37.1 ± 10.6 mL) and patients with lone MR (71.0 ± 35.9, P = .020 and controls and patients with MR + AF (99.3 ± 47.4, P < .001). The difference in LA enhancement was significant between MR + AF (16.7 ± 9.6%) versus controls (8.3 ± 3.9%, P = .006) and MR + AF versus lone MR (8.0 ± 4.8%, P = .004). Similarly, the was significantly more LAPW enhancement in the MR + AF (17.5 ± 8.7%) versus control (9.2 ± 5.1%, P = .011) and MR + AF versus lone MR (9.8 ± 6.0%, P = .020). Conclusions: Patients with MR + AF had significantly more total and LAPW fibrosis compared with both controls and lone MR. Volume and delayed enhancement were associated, but there was no difference between MR and MR + AF.
RESUMO
OBJECTIVE: Expert consensus guidelines recommend surgical ablation (SA) for patients with symptomatic atrial fibrillation (AF), but less than half of patients with AF undergoing cardiac procedures receive concomitant SA. Complete isolation of the left atrial posterior wall (LAPW) has been shown to be the most critical part of the Cox maze procedure. The purpose of this study was to investigate the performance of a novel radiofrequency (RF) bipolar device, EnCompass™ (AtriCure, Inc., Mason, OH, USA), designed to isolate the LAPW in a single application. METHODS: Five adult pigs underwent SA in a beating heart model. After a single ablation, the heart was arrested, explanted, and stained with triphenyl-tetrazolium-chloride for histological assessment. Each lesion was sectioned, and the ablation depth, muscle, and fat thickness were determined. The lesion width, energy delivery, and ablation times were compared with those from a reference RF clamp (Synergy™, AtriCure). RESULTS: Transmurality was documented in 100% of lesions (5 of 5) and cross sections (160 of 160). Electrical isolation was documented in every instance. There was no evidence of clot, charring, or pulmonary vein stenosis. Compared with the reference clamp, the lesions created by the EnCompass™ clamp were 1.5 times wider on average. The average energy delivered was 5 times higher over a duration that was 4.5 times longer due to the increased volume of tissue ablated. CONCLUSIONS: The EnCompass™ clamp reproducibly created transmural isolation of the LAPW with a single application. This may allow for simplification of the SA strategy and increased adoption of AF treatment during concomitant surgery.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Suínos , Animais , Fibrilação Atrial/cirurgia , Átrios do Coração/cirurgia , Resultado do TratamentoRESUMO
OBJECTIVE: The Cox-Maze IV procedure (CMP-IV) is the most effective treatment for atrial fibrillation. Increased left atrial (LA) size has been identified as a risk factor for failure to restore sinus rhythm. This has biased many surgeons against ablation in patients with giant left atrium (GLA), defined as LA diameter >6.5 cm. In this study we aimed to define the efficacy of the CMP-IV in patients with GLA. METHODS: From April 2004 through March 2020, 786 patients with a documented LA diameter underwent elective CMP-IV, 72 of whom had GLA. Median follow-up duration was 4 years (interquartile range, 1-7 years). Recurrence was defined as any documented atrial tachyarrhythmia (ATA) lasting 30 seconds. ATA recurrence and survival were analyzed across GLA versus non-GLA groups. RESULTS: Median age at surgery was 65 (interquartile range, 56-73) years. Median LA diameter within the GLA group was 7.0 (range, 6.6-10.0) cm. There were no differences in rates of postoperative complications for the 2 groups, including rate of postoperative stroke and pacemaker placement (GLA 14%; non-GLA 12%; P = .682). A trend toward increased 30-day mortality in the GLA group did not reach statistical significance (GLA 6%; non-GLA 2%; P = .051). Freedom from ATAs at 5 years postoperatively was comparable for the 2 groups (GLA 82%; non-GLA 84%). CONCLUSIONS: The CMP-IV had good efficacy in patients with GLA. Our results suggest that LA diameter >6.5 cm should not preclude a patient from undergoing surgical ablation for atrial fibrillation.
RESUMO
INTRODUCTION: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, and results in significant morbidity and mortality. The Cox-Maze IV procedure (CMP-IV) has been shown to have excellent efficacy in returning patients to sinus rhythm, but there have been few reports of late follow-up in sizable cohorts of patients with longstanding persistent AF, the most difficult type of AF to treat. METHODS AND RESULTS: Between May 2003 and March 2020, 174 consecutive patients underwent a stand-alone CMP-IV for longstanding persistent AF. Rhythm outcome was assessed postoperatively for up to 10 years, primarily via prolonged monitoring (Holter monitor, pacemaker interrogation, or implantable loop recorder). Fine-Gray regression was used to investigate factors associated with atrial tachyarrhythmia (ATA) recurrence, with death as a competing risk. Median duration of preoperative AF was 7.8 years (interquartile range: 4.0-12.0 years), with 71% (124/174) having failed at least one prior catheter-based ablation. There were no 30-day mortalities. Freedom from ATAs was 94% (120/128), 83% (53/64), and 88% (35/40) at 1, 5, and 7 years, respectively. On regression analysis, preoperative AF duration and early postoperative ATAs were associated with late ATAs recurrence. CONCLUSION: Despite the majority of patients having a long-duration of preoperative AF and having failed at least one catheter-based ablation, the stand-alone CMP-IV had excellent late efficacy in patients with longstanding persistent AF, with low morbidity and no mortality. We recommend consideration of stand-alone CMP-IV for patients with longstanding persistent AF who have failed or are poor candidates for catheter ablation.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração , Humanos , Procedimento do Labirinto , Recidiva , Resultado do TratamentoRESUMO
Intense nanosecond pulsed electric field (nsPEF) is a novel modality for cell activation and nanoelectroporation. Applications of nsPEF in research and therapy are hindered by a high electric field requirement, typically from 1 to over 50â¯kV/cm to elicit any bioeffects. We show how this requirement can be overcome by engaging temporal summation when pulses are compressed into high-rate bursts (up to several MHz). This approach was tested for excitation of ventricular cardiomyocytes and peripheral nerve fibers; for membrane electroporation of cardiomyocytes, CHO, and HEK cells; and for killing EL-4â¯cells. MHz compression of nsPEF bursts (100-1000 pulses) enables excitation at only 0.01-0.15â¯kV/cm and electroporation already at 0.4-0.6â¯kV/cm. Clear separation of excitation and electroporation thresholds allows for multiple excitation cycles without membrane disruption. The efficiency of nsPEF bursts increases with the duty cycle (by increasing either pulse duration or repetition rate) and with increasing the total time "on" (by increasing either pulse duration or number). For some endpoints, the efficiency of nsPEF bursts matches a single "long" pulse whose amplitude and duration equal the time-average amplitude and duration of the bursts. For other endpoints this rule is not valid, presumably because of nsPEF-specific bioeffects and/or possible modification of targets already during the burst. MHz compression of nsPEF bursts is a universal and efficient way to lower excitation thresholds and facilitate electroporation.
Assuntos
Potenciais de Ação/fisiologia , Permeabilidade da Membrana Celular/fisiologia , Eletroporação/métodos , Miócitos Cardíacos/fisiologia , Fibras Nervosas/fisiologia , Animais , Células CHO , Cálcio , Linhagem Celular Tumoral , Células Cultivadas , Cricetulus , Estimulação Elétrica/métodos , Células HEK293 , Humanos , Camundongos Endogâmicos DBA , Miócitos Cardíacos/citologia , Rana catesbeiana/fisiologia , Fatores de TempoAssuntos
Falso Aneurisma/cirurgia , Aneurisma Infectado/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular/efeitos adversos , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Infecções Relacionadas à Prótese/cirurgia , Infecções Estafilocócicas/cirurgia , Falso Aneurisma/diagnóstico , Falso Aneurisma/microbiologia , Aneurisma Infectado/diagnóstico , Aneurisma Infectado/microbiologia , Remoção de Dispositivo , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Reoperação , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Tomografia Computadorizada por Raios X , Resultado do TratamentoRESUMO
BACKGROUND: The Cox Maze-IV procedure (CMP-IV) has replaced the Cox Maze-III procedure as the most common approach for the surgical treatment of atrial fibrillation (AF). The Food and Drug Administration-regulated AtriCure Bipolar Radiofrequency Ablation of Permanent Atrial Fibrillation (ABLATE) trial sought to demonstrate the safety and efficacy of the CMP-IV performed with the Synergy ablation system (AtriCure, Inc, Cincinnati, OH). METHODS: Fifty-five patients (aged 70.5 ± 9.3 years), 92.7% of whom had nonparoxysmal AF, underwent CMP-IV to terminate AF during a concomitant cardiac surgical procedure. Lesions were created using the AtriCure Synergy bipolar radiofrequency ablation system. All patients were seen for follow-up visits after 30 days, 3 months, and 6 months, with 24-hour Holter monitoring at 6 months. Late evaluation was performed by 48-hour Holter monitoring at an average of 21 months. RESULTS: The primary efficacy endpoint, absence of AF (30 seconds or less) at 6-month follow-up off antiarrhythmic medications (Heart Rhythm Society definition), indicated 76% (38 of 50) were AF free (95% confidence interval: 62.6% to 85.7%). The primary safety endpoint, the rate of major adverse events within 30 days, was 9.1% (5 of 55; 95% confidence interval: 3.9% to 19.6%), with 3.6% mortality (2 of 55). Secondary efficacy endpoints included being AF free with antiarrhythmic drugs (6 months, 84%; 21 months, 75%), successful pulmonary vein isolation (100%), and AF burden at 6 and 21 months. The results, together with those for the secondary safety endpoint (6-month major adverse events), demonstrated that the Synergy system performs comparably to the cut-and-sew Cox Maze-III procedure. CONCLUSIONS: The CMP-IV using the AtriCure Synergy system was safe and effective for cardiac surgical patients who had persistent and longstanding persistent AF.