Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Orthop Traumatol Surg Res ; 105(2): 229-236, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30852133

RESUMO

BACKGROUND: Adjustable shoulder hemiarthroplasty (HA) allows the complex anatomy of the proximal humerus, including its centre of rotation, to be restored. However, whether better anatomical adaptation improves clinical outcomes and long-term survival remains unclear. Therefore long-term clinical and radiographic results of an eccentric adjustable hemiprosthesis were examined, focusing on the longevity and fixation of the humeral stem. HYPOTHESIS: Adjustable shoulder HA enhances long-term functional outcomes and reduces complications. MATERIALS AND METHODS: In this prospective multicentre study, 120 HAs were performed using a stemmed hemiprosthesis on 115 patients. The clinical and radiologic outcomes were measured at 3, 6, 12, and 24 months, and thereafter at 4, 7, and 10 years with a median follow-up period of 7.7 years (92.3 months, range 2.6-148.5 months). Revision-free survival rates were calculated up to 10 years postoperatively. RESULTS: The mean Constant-Murley score increased over the first 24 months from 26.2±9.0 to 61.0±17.3 points, then levelled off until the final follow-up. Patients with humeral head necrosis had the best clinical outcomes, while patients with fracture sequelae and rheumatoid arthritis had the worst. Although radiolucent lines were more frequent after cemented fixation, lines of>2mm only occurred after uncemented fixation. Finally, five cases required secondary glenoid implantation, and survival free from stem revision was 99.0% (95% confidence interval [CI], 92.8%-99.9%) at 4 years, 97.6 (95% CI, 90.6%-99.4%) at 7 years, and 92.2% (95% CI, 81.9%-96.8%) at 10 years. DISCUSSION: The study showed that adjustable shoulder HA is a safe and effective treatment option for various degenerative disorders of the shoulder joint. Functional scores first increased, then levelled off after 24 months. Moreover, revision-free survival compared well with previously reported values. Observed stable long-term results confirm that adjustable shoulder HA has beneficial clinical outcomes and a low complication rate.


Assuntos
Hemiartroplastia/métodos , Cabeça do Úmero/cirurgia , Fraturas do Ombro/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Cabeça do Úmero/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Resultado do Tratamento
2.
PLoS One ; 13(11): e0207415, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30427934

RESUMO

OBJECTIVE: Despite the high frequency of HFE gene mutations in Western Europe, widespread screening for HFE hemochromatosis is not recommended due to its variable phenotype. Joint pain and a premature osteoarthritis-like disease including the hip joints are the most frequent manifestation in patients with HFE hemochromatosis and iron overload. Therefore, screening of patients with severe osteoarthritis of the hip could identify patients with HFE hemochromatosis. METHODS: In this prospective cross-sectional study, 940 patients aged <70 years with end-stage osteoarthritis of the hip undergoing elective joint replacement surgery were screened for HFE hemochromatosis and compared to age- and sex-matched controls. RESULTS: No greater prevalence of C282Y homozygosity mutation or elevated serum ferritin or transferrin saturation levels was found in the study cohort with severe osteoarthritis of the hip than in controls from the general population. CONCLUSION: Our screening approach could not identify an increased prevalence of HFE gene mutations and iron overload in younger patients with severe osteoarthritis of the hip.


Assuntos
Proteína da Hemocromatose/genética , Hemocromatose/diagnóstico , Sobrecarga de Ferro/diagnóstico , Osteoartrite do Quadril/diagnóstico , Idoso , Artroplastia de Substituição/métodos , Feminino , Ferritinas/sangue , Genótipo , Hemocromatose/complicações , Hemocromatose/fisiopatologia , Hemocromatose/cirurgia , Humanos , Sobrecarga de Ferro/complicações , Sobrecarga de Ferro/fisiopatologia , Masculino , Pessoa de Meia-Idade , Mutação , Osteoartrite do Quadril/complicações , Osteoartrite do Quadril/fisiopatologia , Osteoartrite do Quadril/cirurgia , Índice de Gravidade de Doença
3.
Acta Histochem ; 116(7): 1199-207, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25109449

RESUMO

Patients with rheumatoid arthritis (RA) show modulated circadian rhythms of inflammatory cytokines and cortisol, which may be associated with a modified expression of clock genes. The expression of major clock genes was previously studied in synovial tissues and fibroblasts of patients with RA and osteoarthritis (OA). We therefore especially aimed to examine the localization of clock genes at the cellular level in synovial tissue. Furthermore we were interested in studying the expression of the D site of albumin promoter (albumin D-box) binding protein (DBP) at the immunohistochemical level in human samples. Methods used include the in situ expression of the clock genes Brain and muscle aryl hydrocarbon receptor nuclear translocator-like 1 (Bmal 1), Circadian Locomotor Output Cycles Kaput (Clock), Period 1 and 2 (Per 1 and Per 2), and DBP was examined by immunohistochemistry in synovial tissues of patients with RA or OA. Additionally, expression profiles of different clock genes were determined over 24h by real time PCR in synovial fibroblasts (SFs) after a 2h serum shock or TNF-α. Results show that all clock genes investigated were found to be expressed both in RA and OA synovial tissues. Double staining against cell specific markers revealed that clock proteins were especially seen in macrophages, SFs and B-lymphocytes. Cell counting showed that clock proteins were found in approximately 5-20% of cells. Additionally, preliminary cell culture experiments showed that TNF-α treatment resulted in differential 24h expression profiles between RA and OA samples and also compared to the results obtained from the serum shock experiments. From our study we conclude that the major clock genes, including DBP, are expressed in samples from RA and OA patients, especially in macrophages and synovial fibroblasts, but also in B-lymphocytes. Preliminary experiments suggest that TNF-α seems to be able to modify clock gene expression in synovial fibroblasts.


Assuntos
Artrite Reumatoide/metabolismo , Peptídeos e Proteínas de Sinalização do Ritmo Circadiano/genética , Fibroblastos/metabolismo , Osteoartrite/metabolismo , Artrite Reumatoide/patologia , Células Cultivadas , Peptídeos e Proteínas de Sinalização do Ritmo Circadiano/metabolismo , Expressão Gênica , Humanos , Macrófagos/metabolismo , Osteoartrite/patologia , Líquido Sinovial/metabolismo , Fator de Necrose Tumoral alfa/fisiologia
4.
J Bone Joint Surg Am ; 92(8): 1720-31, 2010 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-20660235

RESUMO

BACKGROUND: Improved metal-on-metal articulations were reintroduced in total hip replacement to avoid the osteolysis sometimes seen with conventional ultra-high molecular weight polyethylene bearings. Osteolysis and local lymphocytic infiltration have been reported at revision of some metal-on-metal devices. We report similar and additional results in a study of second-generation metal-on-metal hip implants retrieved post mortem. METHODS: Components and surrounding tissues were collected post mortem from seven patients with nine total hip replacements (Zweymüller SL stem with an Alloclassic cup) with Metasul metal-on-metal articulations. All available patient information was recorded. Radiographs of the hips were evaluated for osteolysis. Sections of joint capsule as well as of the femoral implant with surrounding bone were reviewed, and energy-dispersive x-ray analysis was used to evaluate the composition of wear products. The amount of wear was measured for each component (nine femoral heads and eight cup inserts), when possible, by a coordinate measurement machine with use of the dimensional method. RESULTS: The patients died between three and ten years after arthroplasty, and six of the seven were asymptomatic at the time of death. One patient, with the highest rate of total wear (i.e., wear of femoral head and acetabular cup; 7.6 microm/yr), had increasing hip pain for one year, and histological analysis confirmed the radiographic findings of osteolysis. For two other patients, histological analysis confirmed the radiographic findings of asymptomatic osteolysis. For three patients, histological analysis revealed osteolysis that had escaped conventional radiographic analysis. Joint capsule tissue showed evidence of metallosis in all hips and local lymphocytic infiltration in eight hips. Energy-dispersive x-ray analysis revealed elements attributable to CoCrMo alloy in all hips and traces of corrosion products in three hips. CONCLUSIONS: The postmortem findings of osteolysis and/or lymphocytic infiltration associated with eight clinically well-functioning, low wear devices (a total wear rate of <4 microm/yr) suggest there may be frequent, unappreciated femoral bone loss and local immunological response in patients with second-generation metal-on-metal hip implants. Compared with previous postmortem studies, our findings showed the extent of osteolysis was similar to that with metal-on-polyethylene articulations.


Assuntos
Artroplastia de Quadril/efeitos adversos , Fêmur , Prótese de Quadril/efeitos adversos , Osteólise/etiologia , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Autopsia , Materiais Biocompatíveis , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Falha de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA