Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
Hernia ; 28(2): 427-434, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38170300

RESUMO

OBJECTIVE: This study investigated the use of a modified laparoscopic repair of paraostomy hernia technique, called "D-Type parastomal hernia repair surgery" which combines abdominal wall and extraperitoneal stoma reconstruction, in patients with parastomal hernia (PSH) following colorectal stoma surgery. The aim was to determine whether D-type parastomal hernia repair surgery is a promising surgical approach compared to the traditional laparoscopic repair technique (Sugarbaker method) for patients with PSH. METHODS: PSH patients were selected and retrospectively divided into two groups: the study group underwent D-type parastomal hernia repair, while the control group underwent laparoscopic Sugarbaker repair. Clinical data from both groups were analyzed. RESULT: Compared to control group (n = 68), the study group undergoing D-type stoma lateral hernia repair had significant increase in total operative time (98.82 ± 12.37 min vs 124.61 ± 34.99 min, p < 0.001). The study group also showed better postoperative stoma bowel function scores in sensory ability, frequency of bowel movements, and clothing cleanliness without a stoma bag (p = 0.037, 0.001, 0.002). The treatment cost was significantly higher in the control group (3899.97 ± 260.00$ vs 3215.91 ± 230.03$, p < 0.001). The postoperative recurrence rate in the control group was 26.4%, while in the study group, it was 4.3%, with a significant statistical difference (p = 0.024). In terms of long-term postoperative complications, the study group had an overall lower incidence compared to the control group (p = 0.035). Other parameters showed no significant differences between the two groups. CONCLUSION: The study suggests that D-type parastomal hernia repair surgery is a safe and feasible procedure. Compared to traditional surgery, it can reduce the recurrence of lateral hernia, improve postoperative stoma bowel function, and save medical resources.


Assuntos
Hérnia Ventral , Hérnia Incisional , Laparoscopia , Estomas Cirúrgicos , Humanos , Colostomia/efeitos adversos , Colostomia/métodos , Estudos Retrospectivos , Hérnia Ventral/etiologia , Hérnia Ventral/cirurgia , Herniorrafia/métodos , Estomas Cirúrgicos/efeitos adversos , Hérnia Incisional/cirurgia , Hérnia Incisional/complicações , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Telas Cirúrgicas/efeitos adversos
3.
Zhonghua Wai Ke Za Zhi ; 59(6): 470-476, 2021 Jun 01.
Artigo em Chinês | MEDLINE | ID: mdl-34102730

RESUMO

Object To examine the preliminary clinical efficacy of custom-made three-dimensional(3D) printed talus prosthesis in the treatment of collapse talus necrosis. Methods: The clinical data of 8 patients who received 3D printed custom-made talus prostheses replacement for severe collapsed necrosis of the talus at the Orthopaedic Sports Medical Center, the First Affiliated Hospital to Army Medical University were analyzed retrospectively.All patients were male,with an average age of 38.0 years (range:22 to 65 years).There were 5 cases of left talus collapse and 3 cases of right talus collapse,with the course of disease of 29.7 weeks (range:6 to 96 weeks).The CT data of contralateral healthy talus were used for mirror image design references for the prosthesis,and the electron-beam 3D printing technology was used to prepare the prosthesis.Titanium alloy (Ti6Al4V) was taken as the material for the preparation of the talus body prosthesis,and Co-Cr-Mo material was used as the material for the preparation of the tibialis talus lateral joint surface prosthesis,and the subtalar joint surface of the prosthesis was made from a microporous casting technique.The prosthesis was analyzed preoperatively by digital three-dimensional finite element analysis and solid comparison techniques to measure anatomic match of the prosthesis.A longitudinal incision on medial ankle was made.The necrotic talus was completely removed and the prosthesis was then implanted.The patient was reexamined in the outpatient department 3, 6, and 12 months after surgery.Primary outcome measures were the American Orthopaedic Foot and Ankle Society(AOFAS) ankle-hind foot score,visual analogue scale(VAS) and ankle range of motion.Changes in imaging data and plantar pressure were also assessed.Repeated measures analysis of variance and paired-t test were used to compare the data. Results: The talus prosthesis measure preoperatively was completely consistent with that contralateral healthy talus and there was no operation-related complication. All the wounds healed primarily. The patients were followed up effectively for 23.17 months (range:12 to 48 months).The preoperative dorsiflexion of patients was (7.6±5.7)°,it increased to(14.2±6.6)° at 12 month after surgery (t=-2.67,P=0.03).The plantar flexion increased from (22.0±9.9)°preoperatively to (29.2±8.7)° at 12 month after surgery (t=-8.95,P<0.01).Preoperative AOFAS ankle-hind foot score was 26.3±6.6,and it increased to 70.1±2.2,76.0±3.4 and 79.3±4.2 at 3 month,6 month and 12 month after surgery(F=56.81,P<0.01);Pre-operative VAS was[M(QR)]3.0(0.8),and it increased to 2.5(1.0),1.5(1.0),1.0(1.0)at 3 month,6 month and 12 month after surgery(F=20.00,P<0.01).At the last follow-up,imaging reexamination showed that the prosthesis of all patients were in stable position with no sign of subsidence.No secondary ankle fusion or revision was required.The talus height increased from (27.6±6.0)mm preoperatively to (34.6±3.5)mm (t=-2.94,P<0.01).The plantar pressure showed that the maximum pressure on the healthy ankle was(629.9±26.1)N,and that on the affected side was(521.4±14.4)N.The pressure on the healthy ankle was(350.6±29.6)N,and that on the necrotic side was (212.3±9.7)N.The load on the contralateral forefoot was(38.1±2.8)% and that on the necrotic side was(11.5±2.0)%.The load on the contralateral hindfoot was (24.6±2.5)% and that on the necrotic side was (21.1±1.8)%. Conclusions: The custom-made 3D printed talus prosthesis could restore the talus anatomy,recover the ankle joint function,relieve the pain of patients and improve the life quality of patients.The effect on plantar pressure is mainly achieved by adjusting the center of gravity of plantar pressure backwards and the increase of weight bearing of the healthy foot.


Assuntos
Tálus , Articulação do Tornozelo , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Necrose , Impressão Tridimensional , Próteses e Implantes , Estudos Retrospectivos , Tálus/cirurgia , Resultado do Tratamento
4.
Gene ; 273(2): 239-49, 2001 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-11595170

RESUMO

The human homologue of the Drosophila melanogaster orphan nuclear receptor fushi tarazu factor 1 (Ftz-F1), NR5A2 (hB1F), was initially identified as a regulatory factor that binds and activates enhancer II of hepatitis B virus. NR5A2 (hB1F) is expressed specifically in pancreas and liver, playing important roles in the regulation of several liver-specific genes. A detailed analysis on the genomic structure and promoter activity will greatly promote future studies on the function of the NR5A2 (hB1F) gene. In this report, a bacterial artificial chromosome clone and several phage clones covering the NR5A2 (hB1F) gene were isolated and the complete genomic sequence was obtained. Alignment of different cDNAs of the NR5A2 (hB1F) gene with the genomic sequence facilitated the delineation of its structural organization, which spans over 150 kb and consists of eight exons interrupted by seven introns. RT-PCR and 3'-RACE revealed that utilization of two polyadenylation signals results in the 3.8 and 5.2 kb transcripts that were observed previously. The transcription start site of the NR5A2 (hB1F) gene was mapped downstream of a canonical TATA box. An upstream fragment containing binding sites for several liver-specific and ubiquitous transcription factors exhibits hepatocyte-specific promoter activity. Transient transfections indicated that hepatocyte nuclear factors HNF1 and HNF3beta could activate NR5A2 (hB1F) promoter.


Assuntos
Proteínas de Ligação a DNA , Genes/genética , Regiões Promotoras Genéticas/genética , Transativadores/genética , Células 3T3 , Animais , Sequência de Bases , Fatores de Transcrição de Zíper de Leucina e Hélice-Alça-Hélix Básicos , Clonagem Molecular , DNA/química , DNA/genética , Éxons , Células HeLa , Fator 4 Nuclear de Hepatócito , Humanos , Íntrons , Luciferases/genética , Luciferases/metabolismo , Camundongos , Dados de Sequência Molecular , Fosfoproteínas/genética , Fosfoproteínas/fisiologia , Poli A/genética , Receptores Citoplasmáticos e Nucleares , Proteínas Recombinantes de Fusão/genética , Proteínas Recombinantes de Fusão/metabolismo , Análise de Sequência de DNA , Fatores de Transcrição/genética , Fatores de Transcrição/fisiologia , Transcrição Gênica , Transfecção , Células Tumorais Cultivadas
5.
Proc Natl Acad Sci U S A ; 96(20): 11422-7, 1999 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-10500192

RESUMO

The promyelocytic leukemia zinc finger gene (PLZF) is involved in chromosomal translocation t(11;17) associated with acute promyelocytic leukemia. In this work, a 201-kilobase genomic DNA region containing the entire PLZF gene was sequenced. Repeated elements account for 19.83%, and no obvious coding information other than PLZF is present over this region. PLZF contains six exons and five introns, and the exon organization corresponds well with protein domains. There are at least four alternative splicings (AS-I, -II, -III, and -IV) within exon 1. AS-I could be detected in most tissues tested whereas AS-II, -III, and -IV were present in the stomach, testis, and heart, respectively. Although splicing donor and acceptor signals at exon-intron boundaries for AS-I and exons 1-6 were classical (gt-ag), AS-II, -III, and -IV had atypical splicing sites. These alternative splicings, nevertheless, maintained the ORF and may encode isoforms with absence of important functional domains. In mRNA species without AS-I, there is a relatively long 5' UTR of 6.0 kilobases. A TATA box and several transcription factor binding sites were found in the putative promoter region upstream of the transcription start site. PLZF is a well conserved gene from Caenorhabditis elegans to human. PLZF paralogous sequences are found in human genome. The presence of two MLL/PLZF-like alignments on human chromosome 11q23 and 19 suggests a syntenic replication during evolution. The chromosomal breakpoints and joining sites in the index acute promyelocytic leukemia case with t(11;17) also were characterized, which suggests the involvement of DNA damage-repair mechanism.


Assuntos
Proteínas de Ligação a DNA/genética , Rearranjo Gênico , Fatores de Transcrição/genética , Dedos de Zinco/genética , Processamento Alternativo , Sequência de Bases , Éxons , Genes Reguladores , Humanos , Íntrons , Fatores de Transcrição Kruppel-Like , Dados de Sequência Molecular , Proteína com Dedos de Zinco da Leucemia Promielocítica , Receptores do Ácido Retinoico/genética , Recombinação Genética , Receptor alfa de Ácido Retinoico , TATA Box
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA