Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Int Immunopharmacol ; 131: 111816, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38484669

RESUMO

STUDY DESIGN: A prospective study. BACKGROUND: This study aims to investigate the relationship between different states of bipolar disorder (BD) and plasma inflammatory proteins, which may be used as their biomarkers. MATERIALS AND METHODS: We totally collected admission plasma from 16 healthy subjects and 32 BD patients, including 16 patients with BD manic episodes (BD-M) and 16 patients with BD depressive episodes (BD-D). Ten samples in each group were analyzed by proximity extension assays of 92 inflammation-related proteins, and all samples were verified by ELISA. Receiver-operating characteristic (ROC) curve analysis was performed to identify the diagnostic ability and cut-off values of potential biomarkers. RESULTS: Our findings showed that BD patients had significantly higher levels of IL6, MCP-1, TGF-α, IL8, and IL10-RB in comparison with healthy subjects, and their cut-off values were 0.531 pg/ml, 0.531 pg/ml, 0.469 pg/ml, 0.406 pg/ml, and 0.406 pg/ml, respectively. The levels of IL6, MCP-1, TGF-α, and IL8 in BD-M patients were significantly greater than in healthy individuals, and their cut-off values were 0.813 pg/ml, 0.688 pg/ml, 0.438 pg/ml, and 0.625 pg/ml, respectively. Moreover, we found cut-off values of 0.500 pg/mL and 0.688 ng/mL for TGF-α and ß-NGF, respectively, even though the levels in the BD-D group were much higher than in the control group. Furthermore, BD-M patients had significantly higher levels of IL6, FGF-19, IFN-γ, and IL-17C in comparison with BD-D patients. Likewise, 0.687 pg/ml, 0.500 pg/ml, 0.438 pg/ml, and 0.375 pg/ml were their cut-off values, respectively. Our findings also showed that the combination of these proteins had the highest diagnostic accuracy. CONCLUSIONS: Our findings showed that plasma inflammatory proteins were related to BD and its subtypes, which may be utilized as potential biomarkers of different stages of BD. Furthermore, we also found their cut-off values and their combinations to have the highest diagnostic accuracy, providing clinicians with a new method to rapidly differentiate BD and its subtypes and manage early targeted interventions.


Assuntos
Transtorno Bipolar , Humanos , Transtorno Bipolar/diagnóstico , Fator de Crescimento Transformador alfa , Proteômica , Interleucina-6 , Interleucina-8 , Estudos Prospectivos , Biomarcadores
2.
Sci Total Environ ; 912: 169158, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38092217

RESUMO

Anthropogenic emissions are recognized as significant contributors to atmospheric soluble iron (Fe) in recent years, which may affect marine primary productivity, especially in Fe-limited areas. However, the contribution of different emission sources to Fe in marine aerosol has been primarily estimated by modeling approaches. Quantifying anthropogenic Fe based on field measurements remains a great challenge. In this study, online multi-element measurements and Positive Matrix Factorization (PMF) were combined for the first time to quantify sources of atmospheric Fe and soluble Fe in the Northwest Pacific during a cruise in spring 2015. Fe concentration in 624 atmospheric PM2.5 samples measured online was 74.58 ± 90.87 ng/m3. The PMF results showed anthropogenic activities, including industrial coal combustion, biomass burning, and maritime transport, were important in this region, contributing 31.4 % of atmospheric Fe on average. In addition, anthropogenic Fe concentration resolved by PMF was comparable to the simulation results of the CMAQ (Community Multiscale Air Quality) and GEOS-Chem (Goddard Earth Observing System-Chemical transport) models, with better correlation to CMAQ (r = 0.76) than GEOS-Chem (r = 0.26). This study developed a new method to estimate atmospheric soluble Fe, which integrates Fe source apportionment results and Fe solubility from different sources. Soluble Fe concentration was estimated as 3.93 ± 5.14 ng/m3, of which 87.0 % was attributed to anthropogenic emissions. Notably, ship emission alone contributed 27.5 % of soluble Fe, though its contribution to total Fe was only 2.2 %. Finally, the total deposition fluxes of atmospheric Fe (37.11 ± 38.43 µg/m2/day) and soluble Fe (1.85 ± 2.13 µg/m2/day) were estimated. This study developed a new methodology for quantifying contribution of anthropogenic emissions to Fe in marine aerosol, which could greatly help the assessment of impacts of human activities on marine environment.

3.
J Xray Sci Technol ; 31(6): 1333-1340, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37840466

RESUMO

OBJECTIVE: To explore the value of applying computed tomography (CT) radiomics based on different CT-enhanced phases to determine the immunotherapeutic efficacy of non-small cell lung cancer (NSCLC). METHODS: 106 patients with NSCLC who underwent immunotherapy are randomly divided into training (74) and validation (32) groups. CT-enhanced arterial and venous phase images of patients before treatment are collected. Region-of-interest (ROI) is segmented on the CT-enhanced images, and the radiomic features are extracted. One-way analysis of variance and least absolute shrinkage and selection operator (LASSO) are used to screen the optimal radiomics features and analyze the association between radiomics features and immunotherapy efficacy. The area under receiver-operated characteristic curves (AUC) along with the sensitivity and specificity are computed to evaluate diagnostic effectiveness. RESULTS: LASSO regression analysis screens and selects 6 and 8 optimal features in the arterial and venous phases images, respectively. Applying to the training group, AUCs based on CT-enhanced arterial and venous phase images are 0.867 (95% CI:0.82-0.94) and 0.880 (95% CI:0.86-0.91) with the sensitivities of 73.91% and 76.19%, and specificities of 66.67% and 72.19%, respectively, while in validation group, AUCs of the arterial and venous phase images are 0.732 (95% CI:0.71-0.78) and 0.832 (95% CI:0.78-0.91) with sensitivities of 75.00% and 76.00%, and specificities of 73.07% and 75.00%, respectively. There are no significant differences between AUC values computed from arterial phases and venous phases images in both training and validation groups (P < 0.05). CONCLUSION: The optimally selected radiomics features computed from CT-enhanced different-phase images can provide new imaging marks to evaluate efficacy of the targeted therapy in NSCLC with a high diagnostic value.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/terapia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/terapia , Tomografia Computadorizada por Raios X , Imunoterapia , Área Sob a Curva , Estudos Retrospectivos
4.
Sci Total Environ ; 889: 164062, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37207767

RESUMO

Dust storms are a significant concern because of their adverse effects on ambient air quality and human health. To investigate the evolution of dust storms during long-distance transport and its impacts on air quality and human health risks in cities along the transport pathway, we monitored the major fraction of dust (i.e., particle-bound elements) online in four cities in northern China during March 2021. Three dust events originating from the Gobi Desert of North China and Mongolia and the Taklimakan Desert of Northwest China were captured. We investigated the source regions of dust storms using daily multi-sensor absorbing aerosol index products, backward trajectories, and specific element ratios, identified and quantified sources of particle-bound elements using Positive Matrix Factorization model, and calculated the carcinogenic and non-carcinogenic risks of elements using a health risk assessment model. Our results indicated that under the influence of dust storms, mass concentrations of crustal elements increased up to dozens of times in cities near the dust source and up to ten times in cities farther from the source. In contrast, anthropogenic elements increased less or even decreased, depending on the relative contributions of the increase caused by accumulation of dust itself and entrainment along the transport path and the decrease caused by dilution of high wind speeds. Si/Fe ratio was found to be a valuable indicator for characterizing the attenuation of the amount of dust along its transport pathways, especially for the case originated from northern source regions. This study highlights the significant role of source regions, intensity and attenuation rates of dust storms, and wind speeds in determining the increased levels of element concentrations during dust storms and its associated impacts on downwind areas. Furthermore, non-carcinogenic risks of particle-bound elements increased at all sites during dust events, emphasizing the importance of personal exposure protection during dust storms.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Humanos , Poluentes Atmosféricos/análise , Monitoramento Ambiental/métodos , Poeira/análise , Vento , China , Cidades , Material Particulado/análise
5.
Jpn J Radiol ; 41(6): 669-679, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36607550

RESUMO

PURPOSE: To conduct a comparative study of image quality, radiation dose, and iodine intake in hepatic computed tomographic angiography (CTA) of overweight patients with different Gemstone Spectral Imaging (GSI) noise indexes combined with different concentrations of contrast medium. MATERIALS AND METHODS: Ninety patients with a body mass index of ≥ 25 kg/m2 were divided into three groups (A, B and C), each with 30 patients. The three groups underwent hepatic CTA with different NI of 7, 11 and 15, respectively, and were injected with different iodine concentrations of 370, 350 and 320 mgI/mL, respectively. Five sets of images at 40-60 keV (interval, 5 keV) were reconstructed in each group. The CT value, image noise, contrast-to-noise ratio (CNR) and subjective score of the hepatic artery and vein, and portal vein in different monochromatic image sets were analyzed to select the optimal energy level in each group. The differences in CT value, image noise, CNR and a subjective score of hepatic artery and vein, portal vein in the optimal monochromatic images among the three groups were compared, the volume CT dose index (CTDIvol) and dose-length product (DLP) were recorded, and the effective dose and iodine intake were calculated. RESULTS: The 40 keV was determined to be the optimal energy level for the monochromatic image sets in each group. No significant group differences were noted in the CT value, image noise, CNR, and subjective image scores of the hepatic artery and vein, and portal vein for the optimal monochromatic images (P > 0.05). Compared with group A, the effective dose and iodine intake in group B were reduced by 50.18% and 9.3%, and by 58.12% and 14.23% in group C, respectively. CONCLUSION: A low-concentration contrast medium combined with a high-noise GSI index in hepatic CTA of overweight patients can reduce the radiation dose and iodine intake while ensuring image quality.


Assuntos
Angiografia por Tomografia Computadorizada , Iodo , Humanos , Angiografia por Tomografia Computadorizada/métodos , Estudos de Viabilidade , Sobrepeso/diagnóstico por imagem , Doses de Radiação , Meios de Contraste , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
6.
J Environ Sci (China) ; 125: 234-243, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36375909

RESUMO

Heterogeneous agglomeration (HA) is a very potential technology for coal-fired flue gas treatment. In this paper, the distribution and migration mechanisms of trace elements (TEs) such as Se, As and Pb in CFPPs were studied on a 30,000 m3/hr pilot-scale experimental platform. The influences of HA on the removal efficiency of gaseous and particulate TEs were well analyzed. The results showed that Se, As and Pb were enriched in fly ash, and their sensitivity to particle size is quite different. The content of Se was the highest in PM1, reaching 193.04 mg/kg at the electrostatic precipitator (ESP) outlet. The average particle size of the total dust before ESP increased significantly from 21.686 to 62.612 µm after injecting the heterogeneous agglomeration adsorbent, conducive to its further removal by ESP. In addition, the concentrations of gaseous Se, As and Pb in the flue gas decreased after adsorbent spray, and accordingly, their contents in the hierarchical particles increased, indicating that the adsorbent could effectively promote the adsorption of gaseous trace elements in fly ash and reduce the possibility of their escape to the atmosphere. Total concentrations of Se, As and Pb emitted by wet flue gas desulfurization (WFGD) are 0.223, 0.668 and 0.076 µg/m3, which decreased by 59.98%, 47.69% and 90.71%, respectively. Finally, a possible HA mechanism model was proposed, where chemical adsorption, physical condensation and collision agglomeration of gaseous TEs and fine particles with adsorbent droplets occurred to form larger agglomerates.


Assuntos
Poluentes Atmosféricos , Oligoelementos , Oligoelementos/análise , Centrais Elétricas , Cinza de Carvão/química , Poluentes Atmosféricos/análise , Chumbo , Carvão Mineral/análise , Gases , Tecnologia
7.
Pak J Med Sci ; 38(5): 1343-1348, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35799733

RESUMO

Objectives: To investigate the clinical value of contrast-enhanced CT combined with PET/CT in the differential diagnosis of mediastinal lymph node metastasis (MLNM) of non-small-cell lung cancer (NSCLC). Methods: A total of 120 patients with NSCLC combined with mediastinal lymphadenopathy hospitalized in our hospital were selected. All the patients received radical resection of lung cancer and mediastinal lymphadenectomy. After pathological diagnosis, they were divided into MLNM group (malignant group, undergoing contrast-enhanced CT) and non-MLNM group (benign group, receiving contrast-enhanced CT combined with PET-CT). The results were judged by two senior radiologists independently. The results of different scanning methods and postoperative pathology were compared using the t test, χ2 test and Pearson correlation coefficient test. Results: Compared with the pathological results, contrast-enhanced CT diagnosed 31 cases, with a coincidence rate of 62%, and contrast-enhanced CT combined with PET-CT diagnosed 42 cases, with a coincidence rate of 84%, presenting a statistically significant difference (P = 0.02). Among the 120 patients with lung cancer, pathological examination confirmed MLNM in 50 patients and benign enlargement in 70 patients, contrast-enhanced CT alone detected metastasis in 40 patients and benign enlargement in 80 patients, and contrast-enhanced CT combined with PET-CT detected metastasis in 47 patients and benign enlargement in 73 patients. The sensitivity and accuracy of the latter were significantly higher than those of the former (sensitivity, P = 0.01; accuracy, P = 0.01). With the increase in the malignancy of lymph nodes, the degree of CT enhancement, the concentration of radioactive substances and SUV value increased, showing positive correlations. Conclusion: Contrast-enhanced CT combined with PET/CT in the diagnosis of MLNM of NSCLC presents higher coincidence rate, sensitivity and accuracy. With the increase in tumor malignancy, the enhancement degree and radioactive substance concentration increase. The two methods are synergistic and complementary in diagnosing MLNM.

8.
J Xray Sci Technol ; 30(4): 689-696, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35527624

RESUMO

OBJECTIVES: To compare image quality and radiation dose of computed tomography angiography (CTA) of the head and neck in patients using two Gemstone Spectral Imaging (GSI) scanning protocols. METHODS: A total of 100 patients who underwent head-neck CTA were divided into two groups (A and B) according to the scanning protocols, with 50 patients in each group. The patients in group A underwent GSI scanning protocol 1 (GSI profile: head and neck CTA), while those in group B underwent GSI scanning protocol 2 (GSI profile: chest 80 mm). All images were reconstructed using 40% and 70% pre- and post-adaptive level statistical iterative reconstruction V (pre-ASiR-V and post-ASiR-V) algorithms, respectively. The CT dose index (CTDIvol) and dose-length (DLP) product were recorded and the mean value was calculated and converted to the effective dose. CT values, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of all images were calculated. Additionally, subjective image evaluation was conducted by two independent radiologists using a five-point scoring method. All data were statistically analyzed. RESULTS: There were no significant differences in the CT values, SNR, CNR, and subjective score between groups A and B (p > 0.05); however, the mean effective dose (1.2±0.1 mSv) in group B was 45.5% lower than that in group A (2.2±0.2 mSv) (p < 0.05). CONCLUSIONS: GSI scanning protocol 2 could more effectively reduce the radiation dose in head-neck CT angiography while maintaining image quality compared to GSI scanning protocol 1.


Assuntos
Angiografia por Tomografia Computadorizada , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Cabeça , Humanos , Doses de Radiação , Razão Sinal-Ruído
9.
Adv Sci (Weinh) ; 9(11): e2105483, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35238180

RESUMO

The exchange bias effect is extremely expected in 2D van der Waals (vdW) ferromagnetic (FM)/antiferromagnetic (AFM) heterostructures due to the high-quality interface. CrOCl possesses strong magnetic anisotropy at 2D limit, and is an ideal antiferromagnet for constructing FM/AFM heterostructures to explore the exchange bias effect. Here, the exchange bias effect in Fe3 GeTe2 (FGT)/CrOCl heterostructures through both anomalous Hall effect (AHE) and reflective magnetic circular dichroism (RMCD) measurements is studied. In the AHE measurements, the exchange bias field (HEB ) at 3 K exhibits a distinct increase from ≈150 Oe to ≈450 Oe after air exposure, and such variation is attributed to the formation of an oxidized layer in FGT by analyzing the cross-sectional microstructure. The HEB is successfully tuned by changing the FGT/CrOCl thickness and the cooling field. Furthermore, a larger HEB of ≈750 Oe at 1.7 K in FGT/CrOCl heterostructure through RMCD measurements is observed, and it is proposed that the larger HEB in RMCD measurements is related to the distribution of uncompensated spins at the interface. This work reveals several intriguing phenomena of the exchange bias effect in 2D vdW magnetic systems, which paves the way for the study of related spintronic devices.

10.
Environ Res ; 209: 112791, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35101394

RESUMO

Due to the lack of black carbon (BC) measurement data in some cases, elemental carbon (EC) is often used as a surrogate of BC, with a simple assumption that they are interchangeable. Such assumption will inevitably lead to uncertainties in radiative forcing estimation and health impact assessment. In order to quantitatively and systematically evaluate the relationship between BC and EC as well as factors responsible for their difference, 3-year collocated equivalent BC (eBC) and EC measurements with 1-h resolution were performed in Beijing, China continuously from 2016 to 2019. EBC concentration was measured by the multi-wavelength aethalometer (AE-33) based on optical analysis, while EC concentration was determined by semi-continuous OC/EC analyzer with thermal-optical method. The results showed that around 90% of eBC concentration was higher than that of EC, with average difference between eBC and EC as 1.21 µg m-3 (accounting for 33% of average eBC in Beijing). EBC and EC concentrations exhibited strong correlation (r = 0.90) during the whole study period, but the slopes (or eBC/EC ratio) and correlation coefficients varied across seasons (spring: 1.67 and 0.94; summer: 0.91 and 0.65; fall: 1.15 and 0.88; winter: 1.09 and 0.91, respectively). Based on the information from shell/core ratios by Single Particle Soot Photometer (SP2), source apportionment results by positive matrix factorization model, and chemical composition of PM2.5, the differences between eBC and EC concentrations were found to be primarily related to BC aging process and secondary components as evidenced by strong positive correlation with secondary species (e.g., secondary organic carbon and nitrate). This study provided seasonal specific conversion factors of eBC and EC in Beijing and helpful reference for other areas, which will contribute new knowledge of carbonaceous aerosol and reduce uncertainty in assessing future climate change and health studies of BC.


Assuntos
Poluentes Atmosféricos , Fuligem , Aerossóis/análise , Poluentes Atmosféricos/análise , Pequim , Carbono/análise , China , Monitoramento Ambiental/métodos , Material Particulado/análise , Estações do Ano , Fuligem/análise
11.
Dentomaxillofac Radiol ; 50(5): 20200428, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33353399

RESUMO

OBJECTIVES: To analyze and compare the radiation dose and image quality of different CT scanning modes on head-neck CT angiography. METHODS: A total of 180 patients were divided into Group A and Group B. The groups were further subdivided according to different scanning modes: subgroups A1, A2, A3, B1, B2, and B3. Subgroups A1 and B1 used conventional CT protocol, subgroups A2 and B2 used the kV-Assist scan mode, and subgroups A3 and B3 used the dual-energy gemstone spectral imaging protocol. The CT dose index and dose-length product were recorded. The objective image quality and subjective image evaluation was conducted by two independent radiologists. RESULTS: The signal-to-noise ratios, contrast-to-noise ratios, and subjective scores of subgroups A3 and B3 were higher than the other subgroups. In subgroups B1 and B2, the subjective scores of 9 patients and 12 patients were lower than 3, respectively. The subjective scores of subgroups B1 and B2 were lower than the other subgroups. There was no statistically significant difference in signal-to-noise ratios, contrast-to-noise ratios, and subjective scores between subgroups A1 and A2. The effective dose of subgroup A2 was 41.7 and 36.4% lower than that in subgroups A1 and A3, respectively (p < 0.05). In Group B, there were no statistically significant differences in CT dose indexvol, dose-length product, and ED among the subgroups (p > 0.05). CONCLUSION: In the head-neck CT angiography, the kV-Assist scan mode is recommended for patients with body mass index between 18.5 and 34.9 kg m-2; gemstone spectral imaging scanning mode is recommended for patients with body mass index ≥34.9 kg m-2.


Assuntos
Angiografia por Tomografia Computadorizada , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Humanos , Doses de Radiação , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
12.
J Xray Sci Technol ; 29(1): 125-134, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33164983

RESUMO

OBJECTIVE: To determine the optimal pre-adaptive and post-adaptive level statistical iterative reconstruction V (ASiR-V) for improving image quality and reducing radiation dose in coronary computed tomography angiography (CCTA). METHODS: The study was divided into two parts. In part I, 150 patients for CCTA were prospectively enrolled and randomly divided into 5 groups (A, B, C, D, and E) with progressive scanning from 40% to 80% pre-ASiR-V with 10% intervals and reconstructing with 70% post-ASiR-V. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Subjective image quality was assessed using a 5-point scale. The CT dose index volume (CTDIvol) and dose-length product (DLP) of each patient were recorded and the effective radiation dose (ED) was calculated after statistical analysis by optimizing for the best pre-ASiR-V value with the lowest radiation dose while maintaining overall image quality. In part II, the images were reconstructed with the recommended optimal pre-ASiR-V values in part I (D group) and 40%-90% of post-ASiR-V. The reconstruction group (D group) was divided into 6 subgroups (interval 10%, D0:40% post-ASiR-V, D1:50% post - ASiR-V, D2:60% post-ASiR-V, D3:70% post-ASiR-V, D4:80% post-ASiR-V, and D5:90% post-ASiR-V).The SNR and CNR of D0-D5 subgroups were calculated and analyzed using one-way analysis of variance, and the consistency of the subjective scores used the k test. RESULTS: There was no significant difference in the SNRs, CNRs, and image quality scores among A, B, C, and D groups (P > 0.05). The SNR, CNR, and image quality scores of the E group were lower than those of the A, B, C, and D groups (P < 0.05). The mean EDs in the B, C, and D groups were reduced by 7.01%, 13.37%, and 18.87%, respectively, when compared with that of the A group. The SNR and CNR of the D4-D5 subgroups were higher than the D0-D3 subgroups, and the image quality scores of the D4 subgroups were higher than the other subgroups (P < 0.05). CONCLUSION: The wide-detector combined with 70% pre-ASiR-V and 80% post-ASiR-V significantly reduces the radiation dose of CCTA while maintaining overall image quality as compared with the manufacture's recommendation of 40% pre-ASiR-V.


Assuntos
Angiografia por Tomografia Computadorizada , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Humanos , Doses de Radiação , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
13.
J Xray Sci Technol ; 27(5): 981-993, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31450541

RESUMO

OBJECTIVE: To compare image quality, radiation dose, and iodine intake of head-neck CT angiography (CTA) acquired by wide-detector with the gemstone spectral imaging (GSI) combination with low iodine intake or routine scan protocol. METHODS: Three hundred patients who had head-neck CTA were enrolled and divided into three groups according to their BMI values: group A (18.5 kg/m2 ≦ BMI <24.9 kg/m2), group B (24.9 kg/m2 ≦ BMI <29.9 kg/m2) and group C (29.9 kg/m2 ≦ BMI ≦ 34.9 kg/m2) with 100 patients in each group. Patients in each group were randomly divided into two subgroups (n = 50) namely, A1, A2, B1, B2, C1 and C2. The patients in subgroups A1, B1 and C1 underwent GSI with low iodine intake (270 mgI/ml, 50 ml) and combined with the ASiR-V algorithm. Other patients underwent three dimensional (3D) smart mA modulation with routine iodine intake (350 mgI/ml, 60 ml). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of all images were calculated after angiography. Images were then subjectively assessed using a 5-point scale. CT dose index of volume and dose-length product (DLP) was converted to the effective dose (ED) and then compared. RESULTS: The mean CT values, SNR, CNR and subjective image quality in subgroups A2, B2 and C2 are significantly lower than in subgroups A1, B1, and C1 (P < 0.01), respectively. The ED values in subgroup A1, B1, and C1 are 55.18%, 61.89%, and 69.64% lower than those in A2, B2, and C2, respectively (P < 0.01). The total iodine intakes in subgroups A1, B1, and C1 are 35.72% lower than those in subgroups A2, B2, and C2. CONCLUSIONS: The gemstone spectral imaging with monochromatic images at 53-57 keV combined with ASiR-V algorithm allows significant reduction in iodine load and radiation dose in head-neck CT angiography than those yielded in routine scan protocol. It also enhances signal intensity of head-neck CTA and maintains image quality.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Algoritmos , Índice de Massa Corporal , Meios de Contraste/administração & dosagem , Feminino , Humanos , Iodo/administração & dosagem , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Razão Sinal-Ruído
14.
J Xray Sci Technol ; 27(1): 97-110, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30507604

RESUMO

OBJECTIVE: To assess the difference in absorbed organ dose and image quality for head-neck CT angiography using organ dose modulation compared with 3D smart mA modulation in different body mass indices (BMIs) using an adaptive statistical iterative reconstruction (ASiR-V) algorithm. METHODS: Three hundred patients underwent head-neck CTA were equally divided into three groups: A (18.5 kg/m2≦BMI < 24.9 kg/m2), B (24.9 kg/m2≦BMI < 29.9 kg/m2) and C (29.9 kg/m2≦BMI≦34.9 kg/m2). The groups were randomly subdivided into two subgroups (n = 50): A1-A2, B1-B2 and C1-C2. The patients in subgroups A1, B1 and C1 underwent organ dose modulation with the ASiR-V algorithm, while other patients underwent 3D smart mA modulation. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of all head-neck CT angiography images were calculated. Images were then subjectively evaluated. Mean values of several indices including dose-length product (DLP) were computed. The DLP was converted to the effective dose (ED). SNR, CNR and ED in groups A, B, and C were compared in statistical data analysis. RESULTS: SNR, CNR, and subjective image scores show no statistical differences in three groups (P  >  0.05). However, there is significant difference of ED values (P  <  0.05) . For example, in subgroup A1 mean ED values are 15.30% and 23.66% lower than those in subgroup A2 at thyroid gland and eye lens, respectively. Similar patterns also exist in groups B (B1 vs. B2) and C (C1 vs. C2). CONCLUSIONS: Using organ dose modulation and applying the ASiR-V algorithm can more effectively reduce the radiation dose in head-neck CT angiography than using 3D smart mA modulation, while maintaining image quality. Thus, using organ-based dose modulation has the additional benefit of reducing dose to the thyroid gland and eye lens.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Doses de Radiação , Algoritmos , Índice de Massa Corporal , Meios de Contraste , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador , Razão Sinal-Ruído
15.
Cell Physiol Biochem ; 47(1): 97-106, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29763886

RESUMO

BACKGROUND/AIMS: Unlike other organs, which only have one set of capillary network, the renal microvasculature consists of two sets of capillary network series connected by efferent arterioles. Angiotensin II constricts the efferent glomerular artery. Hence, renal tumor blood flow (BF) distribution may be different from tumors in other organs. This study aims to investigate the effects of angiotensin II on the hemodynamics of intrarenal VX2 tumors using perfusion computed tomography(CT). METHODS: Twenty-four male New Zealand white rabbits were randomly divided into three groups: groups A (blank controls), group B (negative controls), and group C (angiotensin II-treated animals). Group B and C were established to the model of intrarenal VX2 tumors. Furthermore, perfusion CT of the kidney was performed in each group. Prior to perfusion CT scan in group C, the mean arterial blood was elevated to 150-160 mmHg by angiotensin II. The BF, blood volume (BV), mean transit time (MTT), capillary permeability-surface area product (PS), and relative permeability-surface area product (RPS) of tumors and renal tissues were calculated. RESULTS: Compared with normal renal cortex tissues in group A, the BF, BV and PS values of tumors in group B were significantly lower, MTT was prolonged and RPS increased. Compared with group B, only the RPS of these tumors increased from 83.23 ± 29.17% to 120.94 ± 31.84% by angiotensin II infusion. Angiotensin II significantly increased the RPS value of the renal cortex distant from the tumor (CDT) and the right renal cortex (RRC). CONCLUSIONS: Perfusion CT can accurately observe the influence of angiotensin II on normal and tumor BF in kidneys. This clarifies the effect of angiotensin II on intrarenal tumor hemodynamics.


Assuntos
Angiotensina II/farmacologia , Hemodinâmica/efeitos dos fármacos , Neoplasias Renais/irrigação sanguínea , Rim/irrigação sanguínea , Tomografia Computadorizada por Raios X/métodos , Vasoconstritores/farmacologia , Animais , Rim/diagnóstico por imagem , Rim/efeitos dos fármacos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/tratamento farmacológico , Masculino , Neovascularização Patológica/diagnóstico por imagem , Neovascularização Patológica/tratamento farmacológico , Perfusão/métodos , Coelhos
16.
Chem Commun (Camb) ; 47(27): 7722-4, 2011 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-21647526

RESUMO

By using a ligand containing pyridyl and carboxylate groups as units, a novel (3,36)-connected and self-interpenetrated metal-organic framework was constructed, which exhibited high thermal stability and gas sorption capabilities.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA