Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Front Oncol ; 14: 1397680, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38779084

RESUMO

Objective: For liquid biopsy of cancer, the extraction of circulating cell-free DNA (cfDNA) from plasma is required. We evaluated the efficacy of use of magnetic submicron particles coated with abundant small zwitterions (MSP-ZEWBs) for extracting short fragments of cfDNA. Methods: We developed and optimized an MSP-ZEWB-based cfDNA extraction method using ampholytic ion-exchange materials and compared its results with those using a control kit. We measured the cfDNA concentration by quantitative polymerase-chain-reaction and using the Qubit method and analyzed cfDNA fragmentation patterns using a bioanalyzer. Results: The fragment size of cfDNA isolated from glycine hydrochloric acid at a pH of 2.2 exhibited a better alignment with the DNA marker. The highest DNA intensity was observed at the final concentration of 0.8% polyethylene glycol 8000. The intensity of cfDNA decreased significantly when isolated from plasma with DNA marker using MSP-ZEWBs with an adsorption buffer containing guanidine hydrochloride or isothiocyanoguanidine. All fragments were successfully extracted using MSP-ZEWBs from both plasma and phosphate-buffered saline. Notably, the intensity of short cfDNA fragments isolated using MSP-ZEWBs remained consistent for recovery of long DNA fragments. indicating a potential selective of small fragments. Conclusion: The extraction of plasma cfDNA with MSP-ZEWBs requires no protein denaturation, shows resistance to cells remaining in plasma, and demonstrates higher overall efficiency and better reproducibility than other extraction methods. Use of MSP-ZEWBs may greatly enhance liquid biopsy of cancers through the analysis of plasma cfDNA in clinical practice.

2.
Medicine (Baltimore) ; 103(4): e37057, 2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38277516

RESUMO

BACKGROUND: Cancer of unknown primary (CUP) is a very challenging disease, accounting for 2% to 9% of all new cancer cases. This type of tumor is a heterogeneous tumor whose primary site cannot be determined by standard examination. It has the characteristics of early metastasis, strong aggressiveness, and unpredictable mode of metastasis. Studies have shown that there is no consensus on the treatment of CUP and that there is a wide range of individual differences. In most cases, surgical removal of tumor is the most typical treatment for pelvic tumors. Herein, we report a case of a large pelvic tumor of unknown origin that had compressed the sigmoid colon and ureter and was completely removed by surgery. Postoperative diagnosis was pelvic metastatic squamous cell carcinoma. CASE SUMMARY: A 68-year-old man with pelvic tumor who initially complained of recurrent low back pain and painful urination. The mass was initially diagnosed as a pelvic tumor of unknown origin. The patient underwent complete resection of the tumor by laparotomy. The tumor was pathologically diagnosed as squamous cell carcinoma. CONCLUSION: Based on the treatment experience of this case, surgery alone cannot improve the poor prognosis of CUP. Since chemotherapy and immunotherapy have achieved promising efficacy in various cancers, and immunotherapy has the characteristics of low side effects and good tolerability, we recommend that patients with CUP should receive chemotherapy and/or immunotherapy for better survival outcomes.


Assuntos
Carcinoma de Células Escamosas , Hidronefrose , Neoplasias Primárias Desconhecidas , Neoplasias Pélvicas , Obstrução Ureteral , Masculino , Humanos , Idoso , Neoplasias Primárias Desconhecidas/patologia , Constrição Patológica , Carcinoma de Células Escamosas/complicações , Carcinoma de Células Escamosas/cirurgia , Carcinoma de Células Escamosas/patologia , Hidronefrose/etiologia , Hidronefrose/cirurgia , Obstrução Ureteral/etiologia , Obstrução Ureteral/cirurgia
3.
Braz. J. Pharm. Sci. (Online) ; 58: e191023, 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1403698

RESUMO

Abstract In the work the andrographolide (AG)-solid dispersions (SDs) were prepared by the spray-drying method, using polyethylene glycol 8000 (PEG8000), Poloxamer188, polyvinylpyrrolidone K30 (PVPK30), Soluplus® as carrier materials. The effect of different polymers as carrier materials on the properties of the AG-SDs were studied. The results showed obvious differences in intermolecular interaction, thermal stability, drug state, powder properties, dissolution behavior, and so on of AG-SDs prepared using different polymers as carrier materials. AG-PEG8000-SD was a partial-crystalline and partial-amorphous powder with smaller surface area and pore volume, but it was easy to wetting and did not swell in contact with dissolved medium. AG-Soluplus®-SD was completely amorphous powder with larger specific surface area and pore volume, but it swelled in contact with water. Therefore, the dissolution profile of AG in AG-PEG8000-SD was similar to that in AG-Soluplus®-SD. Soluplus® and PEG8000 were suitable polymers to design AG-SDs, considering both physicochemical properties and dissolution behaviors. The results of this reseach showed that when selecting carrier materials for SD, we should not only consider the state of drugs in SD and the powder properties of SD, but also consider whether there is swelling when the carrier materials are in contact with the dissolution medium.


Assuntos
Polietilenoglicóis/efeitos adversos , Dissolução , Métodos , Polímeros/análise , Preparações Farmacêuticas/análise , Água , Secagem por Atomização
4.
An. bras. dermatol ; 92(5,supl.1): 14-16, 2017. graf
Artigo em Inglês | LILACS | ID: biblio-887093

RESUMO

Abstract: Epidermolysis bullosa acquisita is a severe autoimmune subepidermal bullous disease. In this report, we described for the first time a patient with epidermolysis bullosa acquisita who developed acute renal failure. There is a possibility that epidermolysis bullosa acquisita and acute renal failure's pathogenesis shared some common autoimmune pathways. Moreover, acute blood volume reduction may be another cause of prerenal kidney failure. Further studies are needed to verify our hypothesis.


Assuntos
Humanos , Masculino , Idoso , Epidermólise Bolhosa Adquirida/complicações , Epidermólise Bolhosa Adquirida/patologia , Injúria Renal Aguda/etiologia , Pele/patologia , Biópsia , Epidermólise Bolhosa Adquirida/tratamento farmacológico , Resultado do Tratamento , Técnica Direta de Fluorescência para Anticorpo , Injúria Renal Aguda/tratamento farmacológico
5.
Rev. bras. farmacogn ; 24(5): 584-590, Sep-Oct/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-730564

RESUMO

Qili Powder, a preparation from Traditional Chinese Medicine, commonly used to treat injuries from falling or stumbling, pain caused by bruising, and traumatic hemorrhage. The aim of the present work was to investigate the application of the superfine pulverization on Qili Powder properties. The physicochemical and medicinal properties of fine Qili Powder with D90 particle size of 164.5 μm, and superfine Qili Powder with D90 particle size of 32.2 μm were investigated. The results showed that with decreasing particle size, the specific surface area and pore volume increased, the fluidity decreased, and the percentage of moisture absorption and the balanced moisture content decreased. Analysis HPLC, XRD and FTIR results indicated that superfine pulverization didn’t influence dracorhodin content, nor the molecular structure and crystal form of Qili Powder. The percentage of dissolution of dracorhodin was significantly improved after superfine pulverization. Pharmacokinetics results confirmed that superfine pulverization increases the absorption rate in rats and dracorhodin content of Qili Powder.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA