Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Glaucoma ; 32(9): 738-743, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37523637

RESUMO

PRCIS: This retrospective study found a statistically significant reduction in mean intraocular pressure (IOP) and the number of medications after intracameral Bimatoprost sustained release (SR) injection in patients with glaucoma. A history of selective laser trabeculoplasty (SLT) did not impact treatment outcomes. PURPOSE: To determine outcomes of Bimatoprost SR on IOP and the number of topical IOP-lowering medications in patients with glaucoma. A secondary objective was to determine the outcomes of Bimatoprost SR in patients with a prior history of SLT. METHODS: Retrospective case series. One hundred eighteen eyes from 84 patients that received Bimatoprost SR by 6 glaucoma specialists at Wills Eye Hospital from March 2020 to September 2021 were examined. The intervention was a single injection of intracameral Bimatoprost SR. The main outcome measures included IOP and the number of medications. RESULTS: The most recent mean follow-up time for all eyes was 27.8 ± 18.6 weeks. The mean posttreatment IOP at the most recent follow-up of 16.6 ± 5.3 mm Hg was significantly lower than the mean under-therapy pretreatment IOP of 18.5 ± 5.7 mm Hg for all eyes ( P < 0.01). The mean posttreatment number of medications at the most recent follow-up of 1.3 ± 1.3 decreased compared with the number of pretreatment medications of 2.1 ± 1.4 for all eyes ( P < 0.01). Analysis of multilevel models controlling for demographic variables demonstrated a statistically significant reduction in IOP and number of medications posttreatment ( P < 0.01). A prior history of SLT (n = 54) had no impact on treatment for both IOP and the number of medications ( P > 0.1 for both). CONCLUSIONS: Intracameral Bimatoprost SR reduced IOP and decreased the number of medications. Prior history of SLT did not impact Bimatoprost SR treatment outcomes.


Assuntos
Glaucoma , Terapia a Laser , Trabeculectomia , Humanos , Bimatoprost , Estudos Retrospectivos , Pressão Intraocular , Preparações de Ação Retardada , Anti-Hipertensivos/uso terapêutico , Glaucoma/tratamento farmacológico , Glaucoma/cirurgia , Resultado do Tratamento
2.
J Glaucoma ; 32(6): 474-479, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36847694

RESUMO

PRCIS: This retrospective case series of patients with open angle glaucoma and prior trabeculectomy or tube shunt surgery found that selective laser trabeculoplasty (SLT) resulted in significant intraocular pressure (IOP) reductions in the intermediate follow-up period in select cases. PURPOSE: The purpose of this study was to assess the IOP-lowering effect and tolerability of SLT after prior trabeculectomy or tube shunt surgery. MATERIALS AND METHODS: Open angle glaucoma patients at Wills Eye Hospital who previously underwent incisional glaucoma surgery and subsequently received SLT between 2013 and 2018 were included, along with an age-matched control group. Baseline characteristics, procedural data, and post-SLT data were recorded at 1, 3, 6, 12 months, and most recent visit. The primary success of SLT treatment was defined as IOP reduction of 20% or greater without the use of additional glaucoma medications compared to pre-SLT IOP. Secondary success was defined as IOP reduction ≥20% with the use of additional glaucoma medications compared to pre-SLT IOP. RESULTS: There were 45 eyes in the study group and 45 eyes in the control group. In the study group, IOP decreased from a baseline of 19.5±4.7 mm Hg on 2.2±1.2 medications to 16.7±5.2 mm Hg ( P =0.002) on 2.2±1.1 glaucoma medications ( P =0.57). In the control group, IOP decreased from 19.5±4.2 mm Hg on 2.4±1.0 medications to 16.4±5.2 mm Hg ( P =0.003) on 2.1±1.3 medications ( P =0.36). There was no difference in IOP reduction or change in number of glaucoma medications after SLT at any postoperative visit between the 2 groups ( P ≥0.12 for all). Primary success rates at 12 months were 24.4% for the control group and 26.7% for the prior incisional glaucoma surgery group with no significant difference between the groups ( P =0.92). There were no persistent complications after SLT treatment in either group. CONCLUSION: SLT may effectively lower IOP in patients with open angle glaucoma who have had previous incisional glaucoma surgery and should be considered in select cases.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Terapia a Laser , Hipotensão Ocular , Trabeculectomia , Humanos , Trabeculectomia/métodos , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/tratamento farmacológico , Pressão Intraocular , Estudos Retrospectivos , Glaucoma/cirurgia , Malha Trabecular/cirurgia , Terapia a Laser/métodos , Hipotensão Ocular/cirurgia , Lasers , Resultado do Tratamento
4.
J Ophthalmic Vis Res ; 15(3): 412-418, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32864072

RESUMO

PURPOSE: Orbital cellulitis (OC) is a rare postoperative complication of glaucoma drainage device (GDD) implantation. To date, there have only been 10 reported cases of OC following GDD implantation. CASE REPORT: Here, we report a case of OC in a 57-year-old man who developed pain, proptosis, and limited extraocular motility two days after uneventful Ahmed FP7 implantation in the right eye. Contrast-enhanced computed tomography of the orbits demonstrated fat stranding and a small fluid collection, consistent with OC. He had minimal improvement with intravenous antibiotics and ultimately underwent GDD explantation. A systematic review of the literature showed that the development of OC following GDD implantation can occur in the early or late postoperative period. Immediate hospitalization with intravenous administration of broad-spectrum antibiotics is recommended. Explantation of the infected GDD is often required for source control. CONCLUSION: OC is a rare postoperative complication of GDD implantation. Prompt evaluation and treatment are required, often combined with GDD explantation.

5.
Ophthalmol Glaucoma ; 3(2): 97-102, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32672601

RESUMO

PURPOSE: Selective laser trabeculoplasty (SLT) is a common procedure to lower intraocular pressure (IOP) in patients with glaucoma. However, reports are conflicting regarding what factors contribute to SLT success. The purpose of this study was to determine predictors of SLT success. DESIGN: Retrospective case series. PARTICIPANTS: All patients treated with SLT between January 1, 2012, and June 30, 2018. METHODS: Baseline, demographic, procedural, and ophthalmic examination data were recorded at the time of first SLT treatment. Intraocular pressure and medication data were recorded at all follow-up visits. MAIN OUTCOME MEASURES: Selective laser trabeculoplasty success was defined as IOP decrease of 20% or more from baseline at the 3-month, 6-month, and 12-month follow-up visits. Eyes were considered to have failed and were censored when additional SLT or glaucoma surgery was performed. Patients were excluded if they had less than 3 months of follow-up. RESULTS: A total of 997 eyes from 677 patients were included in the study. Mean age was 70.2±11.5 years. Selective laser trabeculoplasty success was achieved in 227 eyes (22.8%), whereas 770 eyes (77.2%) did not meet success criteria. Intraocular pressure before SLT was 21.9±5.2 mmHg while taking 2.0±1.2 medications in eyes with successful SLT, compared with 19.0±5.0 mmHg (P < 0.0001) while taking 2.1±1.3 medications (P = 0.52) in eyes with SLT failure. At the 1-year follow-up, mean IOP in eyes with SLT success was 14.7±3.2 mmHg with 2.0±1.2 medications, compared with 16.3±4.7 mmHg (P = 0.008) with a mean of 1.9±1.3 medications (P = 0.37) in eyes with SLT failure. Eyes with SLT success more often showed greater angle pigment (P = 0.03). Age, glaucoma severity, total SLT power, type of glaucoma, severity of glaucoma, visual field mean defect, and retinal nerve fiber layer thickness were not found to correlate with success. No difference was found between the rate of success based on treatments before SLT, whether surgical or medical. CONCLUSIONS: In this large cohort of eyes undergoing SLT, greater IOP and angle pigment before SLT correlated positively with SLT success. Age, total SLT power, severity of glaucoma, and prior treatments were not associated with SLT success or failure.


Assuntos
Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular/fisiologia , Terapia a Laser/métodos , Trabeculectomia/métodos , Acuidade Visual , Idoso , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
6.
J Glaucoma ; 29(8): 704-710, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32398592

RESUMO

PRéCIS:: Intracameral injection of viscoelastic at the beginning of Ahmed FP7 implantation did not reduce early postoperative complication rates. PURPOSE: To evaluate early postoperative complication rates after a modified technique in which the anterior chamber (AC) is filled with viscoelastic at the beginning of Ahmed FP7 implantation before conjunctival peritomy. SUBJECTS AND METHODS: A retrospective chart review was performed of eyes that underwent Ahmed FP7 implantation with or without viscoelastic fill to ~20 mm Hg by finger tension by a single surgeon (M.R.M). Viscoelastic prevented the AC from becoming shallow at any time during surgery, and additional viscoelastic was injected into the AC at the end of surgery to achieve a final intraocular pressure (IOP) of 20 mm Hg. RESULTS: A total of 159 eyes of 159 patients were included. Mean age was 76.4±10.4 years. Mean preoperative IOP was 30.3±9.7 mm Hg on 2.7±1.2 glaucoma medications. On postoperative day 1, there was an IOP spike ≥30 mm Hg in 0% of patients. Within the first postoperative month, hypotony (<5 mm Hg) occurred in 19 (21.8%) eyes that received viscoelastic fill compared with 5 (13.2%) eyes that did not receive viscoelastic fill (P=0.26). During the early postoperative period (≤3 mo), there was no difference in AC depth, microhyphema, choroidal effusion, or leakage between the 2 groups (P≥0.30 for all). There was a higher rate of layered hyphemas in the viscoelastic-fill group at postoperative week 1 (P=0.01). At 3-month follow-up, mean IOP was 14.9±5.5 mm Hg on 1.6±0.8 medications in the viscoelastic-fill group and 16.0±5.2 mm Hg on 1.0±1.2 medications in the nonviscoelastic-fill group (IOP P=0.35). Compared with baseline, change in IOP at 3 months was similar between both groups (P=0.15). Rates of additional medications and procedures did not differ between the 2 groups at any postoperative visit. CONCLUSIONS: Early intracameral injection of viscoelastic during Ahmed glaucoma valve implantation did not reduce early postoperative complication rates.


Assuntos
Câmara Anterior/efeitos dos fármacos , Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Ácido Hialurônico/administração & dosagem , Implantação de Prótese , Viscossuplementos/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Câmara Anterior/cirurgia , Túnica Conjuntiva/cirurgia , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tonometria Ocular/efeitos adversos , Trabeculectomia/métodos , Resultado do Tratamento , Acuidade Visual/fisiologia
7.
J Cataract Refract Surg ; 45(12): 1704-1710, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31856979

RESUMO

PURPOSE: To determine the efficacy, safety, and surgical outcomes of trabecular microbypass stent (iStent) surgery performed by resident trainees and attending surgeons. SETTING: Wills Eye Hospital, Philadelphia, Pennsylvania, USA. DESIGN: Retrospective case series. METHODS: Records of all patients who had microbypass stent surgery by a resident at Wills Eye Hospital were retrospectively reviewed. The attending-performed group included any patient who had a microbypass stent implanted by an attending surgeon on the same day a resident case was performed. RESULTS: Between 2016 and 2018, 31 microbypass stents were implanted by a resident supervised by an attending and 93 microbypass stents were implanted by an attending surgeon on the day a resident case was performed. The mean follow-up was 16.2 months ± 17.9 (SD). The mean intraocular pressure (IOP) decreased from 16.0 ± 4.6 mm Hg at baseline to 14.0 ± 3.1 mm Hg at most recent follow-up visit in the resident group (P = .02) and from 17.5 ± 4.8 mm Hg to 15.1 ± 4.3 mm Hg, respectively, in the attending group (P < .001). The final mean IOP and mean number of hypotensive medications were similar between the 2 groups (P = .83 and P = .12, respectively). Self-resolving hyphema occurred in 1 resident case and 2 attending cases. The resident group had 1 case of iridodialysis, which did not require additional surgery. One eye in the attending group ultimately required a trabeculectomy. CONCLUSION: Microbypass stent implantation by resident trainees with attending supervision had similar efficacy and safety as surgery performed by attending surgeons.


Assuntos
Educação de Pós-Graduação em Medicina/métodos , Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Internato e Residência/métodos , Oftalmologia/educação , Malha Trabecular/cirurgia , Trabeculectomia/educação , Idoso , Competência Clínica , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
8.
J Glaucoma ; 28(12): 1090-1094, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31425336

RESUMO

PRéCIS:: This case series reports safe, effective implantation of XEN gel stents to treat iridocorneal endothelial (ICE) syndrome. The stents continue to function well and have not been occluded by membranes or peripheral anterior synechiae, but continued follow-up is necessary. PURPOSE: ICE syndrome-related glaucoma is often refractory to medical treatment, and traditional surgical treatment has lower success rates than typical for other types of glaucoma. We present a series of patients who were treated with XEN gel stent implantation. PATIENTS AND METHODS: Retrospective case series of 4 patients with ICE syndrome who underwent XEN with subconjunctival mitomycin C injection. RESULTS: Average preoperative intraocular pressure was 28.5 mm Hg on 3.8 glaucoma medications, and average postoperative intraocular pressure was 10.5 mm Hg on 1.0 medication. No patients required return to the operating room for additional procedures over an average of 6.9 months of follow-up. One patient had shallow anterior chamber that resolved with conservative management. Another had shallow anterior chamber that resolved with anterior chamber reformation with viscoelastic and developed nonappositional choroidal effusions that had resolved at most recent follow-up of 7 months after surgery. No XEN implants have been occluded by membrane formation or peripheral anterior synechiae. CONCLUSIONS: XEN is a safe and effective option for surgical management of ICE syndrome-related glaucoma. Further follow-up surveillance is necessary.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Síndrome Endotelial Iridocorneana/complicações , Stents , Adulto , Idoso de 80 Anos ou mais , Alquilantes/administração & dosagem , Túnica Conjuntiva/efeitos dos fármacos , Feminino , Glaucoma de Ângulo Aberto/etiologia , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Mitomicina/administração & dosagem , Implantação de Prótese , Estudos Retrospectivos , Tonometria Ocular , Adulto Jovem
9.
Int J Ophthalmol ; 10(5): 738-741, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28546930

RESUMO

AIM: To describe a novel technique of creating a landing strip within the trabecular meshwork to guide trabecular micro-bypass stent (iStent) implantation in patients who underwent phacoemulsification. METHODS: Thirty-four eyes from 30 patients who underwent iStent implantation after phacoemulsification from May 2014 to February 2015 were included in our retrospective study. All iStents were implanted via the "landing strip" technique. A 25-gauge microvitreoretinal blade was used to bisect the trabecular meshwork to less than 1 clock-hour, effectively creating a landing strip. The iStent applicator was pressed along the landing strip and then the stent was released into the trabecular meshwork. RESULTS: Of the 34 eyes with iStent implantation, 27 (79.4%) eyes had primary open-angle glaucoma, 6 (17.6%) eyes had pseudoexfoliation glaucoma, and 1 (2.9%) eye had ocular hypertension. At 6-month follow-up (n=17), the mean number of hypotensive medications decreased from 2.2±1.2 at baseline to 0.8±1.3 (P=0.05) and mean intraocular pressure decreased from 19.7±4.1 mm Hg at baseline to 16.7±2.1 mm Hg (P=0.58). Two eyes (5.9%) required subsequent trabeculectomy. CONCLUSION: The "landing strip" technique appears to be an effective way to assist with iStent implantation.

10.
Ophthalmic Plast Reconstr Surg ; 33(2): e33-e36, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27046037

RESUMO

Orbital extension of subgaleal hematoma is rare. This report describes the case of an otherwise healthy 10-year-old girl who developed delayed contralateral proptosis and external ophthalmoplegia after relatively minor right-sided forehead trauma. She was found to have bilateral subgaleal hematomas communicating with a left superior subperiostial orbital hematoma. Over the course of 2 days, she developed an orbital compartment syndrome requiring emergent canthotomy and cantholysis, followed by surgical incision and drainage of her scalp hematoma without orbitotomy. Hematologic work-up revealed heterozygous factor VII deficiency.


Assuntos
Síndromes Compartimentais/etiologia , Traumatismos Craniocerebrais/complicações , Hematoma/etiologia , Doenças Orbitárias/diagnóstico , Criança , Deficiência do Fator VII/complicações , Feminino , Humanos
11.
Retina ; 37(6): 1160-1167, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27673715

RESUMO

PURPOSE: To report the clinical features, microbial spectrum, and treatment outcomes of endophthalmitis after glaucoma drainage implant (GDI) surgery. METHODS: Records of patients diagnosed with endophthalmitis after GDI surgery were reviewed. Data on clinical course, microbiological laboratory results, and treatment were analyzed. RESULTS: Of 1,891 eyes that underwent GDI surgery, 14 eyes (0.7%) developed endophthalmitis. The mean time interval between GDI surgery and diagnosis of endophthalmitis was 2.6 ± 3.2 years (median, 1.3 years; range, 11 days-11.4 years). For initial treatment, 13/14 eyes underwent vitreous tap and injection of intravitreal antibiotics and 1/14 eyes underwent primary pars plana vitrectomy. Three additional eyes underwent pars plana vitrectomy because of deteriorating clinical course. Glaucoma drainage implant erosion was present in 9/14 eyes. All 9 eroded GDIs were surgically removed within a mean of 9 ± 5 days (range 2-29 days) after diagnosis of endophthalmitis. Overall, mean logarithm of the minimum angle of resolution best-corrected visual acuity worsened from 0.7 ± 0.7 (Snellen equivalent 20/100) at baseline to 1.6 ± 1.1 (Snellen equivalent 20/800) at final follow-up (P = 0.005). Mean duration between the onset of symptoms and presentation was significantly longer in patients with decreased final best-corrected visual acuity (>2 Snellen lines) compared to patients with stable final best-corrected visual acuity (6.8 vs. 1.0 days; P = 0.005). CONCLUSION: Glaucoma drainage implant-related endophthalmitis is rare and often associated with GDI erosion. Patients who presented earlier after the onset of symptoms had better final visual outcomes. Prompt evaluation and treatment is required, often with removal of the eroded GDI.


Assuntos
Endoftalmite/microbiologia , Infecções Oculares Bacterianas/microbiologia , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma/cirurgia , Complicações Pós-Operatórias , Corpo Vítreo/microbiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Remoção de Dispositivo , Endoftalmite/diagnóstico , Endoftalmite/terapia , Infecções Oculares Bacterianas/diagnóstico , Infecções Oculares Bacterianas/terapia , Feminino , Seguimentos , Glaucoma/diagnóstico , Implantes para Drenagem de Glaucoma/microbiologia , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Prognóstico , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Vitrectomia/métodos
12.
J Glaucoma ; 25(4): e340-5, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26709499

RESUMO

PURPOSE: To describe the outcomes of eyes that have undergone a second glaucoma drainage implant (GDI) surgery. METHODS: A retrospective review of eyes that underwent a second GDI surgery from 2006 to 2013 was conducted. Primary outcome measures included intraocular pressure (IOP) reduction and success rates. Secondary outcome measures included glaucoma medication use, visual acuity, and number of reoperations. Success was defined as 6 ≤ IOP ≤ 21 with at least 20% IOP reduction, and no increase in the number of glaucoma medications from baseline at 3 months of follow-up or more. RESULTS: Sixty-five eyes (63 patients) had a mean follow-up of 22.4 ± 19.9 months. The most frequently placed second GDIs were an Ahmed FP7 (49%) or a Baerveldt 250 (26%) in the inferotemporal (46%) or inferonasal (35%) quadrant. At 3-year follow-up, IOP was reduced from 25.8 ± 7.7 to 17.4 ± 9.9 mm Hg (P = 0.004) and the number of glaucoma medications decreased from 3.6 ± 1.2 to 2.5 ± 1.4 (P = 0.01) compared with baseline. The median time to failure was 24.7 ± 5.8 months. There was no significant difference in failure rates for type of sequential GDI (P = 0.80) or plate location (P = 0.34). There was no significant difference in visual acuity between baseline and 3-year follow-up (P = 1.0). The most common postoperative complication was corneal edema (n = 9, 14%). CONCLUSIONS: Most eyes undergoing a second GDI achieve adequate IOP control with fewer antiglaucoma medications. Failure rates were similar regardless of quadrant selection or GDI type.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma/cirurgia , Pressão Intraocular/fisiologia , Implantação de Prótese , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Hipotensão Ocular/cirurgia , Complicações Pós-Operatórias , Reoperação , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA