Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
EJNMMI Phys ; 10(1): 51, 2023 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-37695324

RESUMO

BACKGROUND: Conventional clinical PET scanners typically have an axial field of view (AFOV) of 15-30 cm, resulting in limited coverage and relatively low photon detection efficiency. Taking advantage of the development of long-axial PET/CT, the uEXPLORER PET/CT scanner with an axial coverage of 194 cm increases the effective count rate by approximately 40 times compared to that of conventional PET scanners. Ordered subset expectation maximization (OSEM) is the most widely used iterative algorithm in PET. The major drawback of OSEM is that the iteration process must be stopped before convergence to avoid image degradation due to excessive noise. A new Bayesian penalized-likelihood iterative PET reconstruction, named HYPER iterative, was developed and is now available on the uEXPLORER total-body PET/CT, which incorporates a noise control component by using a penalty function in each iteration and finds the maximum likelihood solution through repeated iterations. To date, its impact on lesion visibility in patients with a full injected dose or half injected dose is unclear. The goal of this study was to determine a proper protocol for routine 18F-FDG uEXPLORER total-body PET/CT scans. RESULTS: The uEXPLORER total-body PET/CT images reconstructed using both OSEM and HYPER iterative algorithms of 20 tumour patients were retrospectively reviewed. The quality of the 5 min PET image was excellent (score 5) for all of the dose and reconstruction methods. Using the HYPER iterative method, the PET images reached excellent quality at 1 min with full-dose PET and at 2 min with half-dose PET. The PET image reached a similar excellent quality at 2 min with a full dose and at 3 min with a half dose using OSEM. The noise in the OSEM reconstruction was higher than that in the HYPER iterative. Compared to OSEM, the HYPER iterative had a slightly higher SUVmax and TBR of the lesions for large positive lesions (≥ 2 cm) (SUVmax: up to 9.03% higher in full dose and up to 12.52% higher in half dose; TBR: up to 8.69% higher in full dose and up to 23.39% higher in half dose). For small positive lesions (≤ 10 mm), the HYPER iterative had an obviously higher SUVmax and TBR of the lesions (SUVmax: up to 45.21% higher in full dose and up to 74.96% higher in half dose; TBR: up to 44.91% higher in full dose and up to 93.73% higher in half dose). CONCLUSIONS: A 1 min scan with a full dose and a 2 min scan with a half dose are optimal for clinical diagnosis using the HYPER iterative and 2 min and 3 min for OSEM. For quantification of the small lesions, HYPER iterative reconstruction is preferred.

2.
Nucl Med Commun ; 44(11): 1011-1019, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37661771

RESUMO

OBJECTIVE: In this study, the potential advantage of FAPI over 18 F-labelled deoxyglucose ( 18 F-FDG) in evaluation of the initial staging colorectal cancer (CRC) was investigated. MATERIALS AND METHODS: Thirty-two patients with histopathologically confirmed primary CRC were included in our study. They all underwent both 18 F-FDG and FAPI PET/CT. Lesion detectability and tracer uptakes, mainly quantified by maximum standardized uptake value (SUVmax) and target-to-background ratio (TBR), were compared for paired lesions between both modalities using the Wilcoxon signed-rank test and paired t-test. RESULTS: Thirty-five CRC lesions in 32 patients were diagnosed. The sensitivity of FAPI PET/CT in diagnosis of the CRC lesions was 100% while 93.8% of 18 F-FDG PET/CT. FAPI and 18 F-FDG had a similar uptake in CRC lesion (mean SUVmax: 14.3 ±â€…8.6 vs. 15.4 ±â€…9.8, P  = 0.604), but lesions contained mucus and/or signet-ring cell carcinoma seemed to have a trend of higher FAPI uptake although there was no statistical difference (mean SUVmax: 12.7 ±â€…5.6 vs. 8.5 ±â€…4.1, P  = 0.152) and higher TBR (13.4 ±â€…6.2 vs. 4.9 ±â€…2.2, P  = 0.004) than those of 18 F-FDG. For regional lymph node metastases, both FAPI and FDG PET/CTs showed high sensitivity (7/8 vs. 7/8), specificity (7/8 vs. 6/8) and accuracy (14/16 vs. 13/16) (all P  > 0.05). For distant metastasis, FAPI PET/CT depicted more positive lesions in distant lymph node (46 vs. 26), liver (13 vs. 7) and peritoneum (107 vs. 45) than 18 F-FDG PET/CT. FAPI PET/CT also had a higher peritoneal cancer index score (median 11 vs 4; P  < 0.001) than 18 F-FDG PET/CT in evaluation of peritoneal metastases. CONCLUSION: FAPI PET/CT showed high sensitivity in detection of primary CRC and superiority to 18 F-FDG PET/CT in detection of metastases to distant lymph node, liver and peritoneum.


Assuntos
Neoplasias Colorretais , Quinolinas , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons , Neoplasias Colorretais/diagnóstico por imagem , Fibroblastos , Radioisótopos de Gálio
3.
Radiology ; 303(1): 191-199, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34981976

RESUMO

Background Gallium 68 (68Ga)-labeled fibroblast-activation protein inhibitor (FAPI) has recently been introduced as a promising tumor imaging agent. Purpose To compare 68Ga-FAPI PET/CT with fluorine 18 (18F)-labeled fluorodeoxyglucose (FDG) PET/CT in evaluating lung cancer. Materials and Methods In this prospective study conducted from September 2020 to February 2021, images from participants with lung cancer who underwent both 68Ga-FAPI and 18F-FDG PET/CT examinations were analyzed. The tracer uptakes, quantified by maximum standardized uptake value (SUVmax) and target-to-background ratio (TBR), were compared for paired positive lesions between both modalities using the paired t test or Wilcoxon signed-rank test. Results Thirty-four participants (median age, 64 years [interquartile range: 46-80 years]; 20 men) were evaluated. From visual evaluation, 68Ga-FAPI PET/CT and 18F-FDG PET/CT showed similar performance in the delineation of primary tumors and detection of suspected metastases in the lungs, liver, and adrenal glands. The metabolic tumor volume in primary and recurrent lung tumors showed no difference between modalities (mean: 11.6 vs 10.8, respectively; P = .68). However, compared with 18F-FDG PET/CT, 68Ga-FAPI PET/CT depicted more suspected metastases in lymph nodes (356 vs 320), brain (23 vs 10), bone (109 vs 91), and pleura (66 vs 35). From semiquantitative evaluation, the SUVmax and TBR of primary or recurrent tumors, positive lymph nodes, bone lesions, and pleural lesions at 68Ga-FAPI PET/CT were all higher than those at 18F-FDG PET/CT (all P < .01). Although SUVmax of 68Ga-FAPI and 18F-FDG in brain metastases were not different (mean SUVmax: 9.0 vs 7.4, P = .32), TBR was higher with 68Ga-FAPI than with 18F-FDG (mean: 314.4 vs 1.0, P = .02). Conclusion Gallium 68-labeled fibroblast-activation protein inhibitor PET/CT may outperform fluorine 18-labeled fluorodeoxyglucose PET/CT in staging lung cancer, particularly in the detection of metastasis to the brain, lymph nodes, bone, and pleura. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Jacobson and Van den Abbeele in this issue.


Assuntos
Neoplasias Pulmonares , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Feminino , Flúor , Fluordesoxiglucose F18 , Radioisótopos de Gálio , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Prospectivos
4.
Clin Nucl Med ; 36(10): 894-8, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21892040

RESUMO

PURPOSE: Because of paucity of data available regarding the utility of PET/CT in the diagnosis and staging of patients with olfactory neuroblastoma (ONB), we retrospectively analyzed the efficacy of PET/CT in 9 patients with ONB. MATERIALS AND METHODS: Whole-body F-18 FDG PET/CT was performed in 7 patients with newly diagnosed ONB, as well as in 1 patient with recurrence and in 1 patient with remnant tumor. Regional C-11 choline (C-11 CHO) PET/CT was performed in 2 patients with negative F-18 FDG scans. The lesion with intense radiotracer uptake was suggested as positive for tumor and the results of PET/CT were compared with conventional staging examinations. RESULTS: F-18 FDG PET/CT was positive in 7/9 (77.7%) patients with ONB. In 2 patients with negative F-18 FDG, the lesions were C-11CHO avid. Both the primary tumors and its invasions were clearly delineated by F-18 FDG or C-11 CHO PET/CT. SUVmax of F-18 FDG in the primary tumor was 6.37 ± 4.22 and did not correlate with lesion size (F-18 FDG/size: r = 0.097, P = 0.820). Whole-body F-18 FDG PET/CT detected parapharyngeal and cervical lymph node metastases in 2 patients, lung metastases in 1 patient, liver metastases in 1 patients, and bone metastases in 2 patients. PET/CT altered the stages of 3 of 9 patients with upstaging in 2 patients and downstaging in 1 patient. CONCLUSIONS: PET/CT may be useful for the diagnosis and staging of ONB.


Assuntos
Estesioneuroblastoma Olfatório/diagnóstico por imagem , Imagem Multimodal , Cavidade Nasal/diagnóstico por imagem , Neoplasias Nasais/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cavidade Nasal/patologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA